Electrical Warnings / Advertencias eléctricas / Avertissements électriques

Failure to follow these precautions could result in serious injury or death. Replace the float switch immediately if cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, ttings, float housing, or cable.

ELECTRICAL SHOCK HAZARD Disconnect power before installing or servicing this product. A quali ed service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD Do not use this product with flammable liquids. Do not install in hazardous locations as de ned by National Electrical Code, ANSI/NFPA 70.

No obedecer estas precauciones podría resultar en lesiones serias o mortales. Reemplace el interruptor de flotador de inmediato si el cable se daña o se cortó. Después de la instalación, guardar estas instrucciones junto con la garantía. Este producto debe ser instalado siguiendo el Código Eléctrico Nacional de EE.UU., ANSI/NFPA 70, para evitar la entrada o acumulación de humedad en cajas de conexión, conductos, acoples, la caja del indicador de nivel (flotador) o el cable.

PRECAUCION

RIESGO DE CHOQUE ELÉCTRICO Desconecte el cable de alimentación antes

de instalar este producto o de hacerle

mantenimiento. La instalación y el mantenimiento

de este producto deben ser efectuados por

personal idóneo siguiendo las normas aplicables

en cuanto a instalaciones eléctricas y plomería.

PRECAUCION

RIESGO DE INCENDIO O EXPLOSIÓN No utilice este producto con líquidos

inflamables.

No lo instale en lugares peligrosos

de nidos como tales en el Código Eléctrico

Nacional de Estados Unidos, ANSI/NFPA 70.

Ignorer ces précautions, et ne pas les suivre attentivement pourrai résulter en blessures graves, voire mortelles. Remplacer immédiatement le flotteur si le câble est endommagé ou coupé. Une fois le produit installé, conserver ces instructions avec la garantie. Ce produit doit être installé conformément aux codes électriques des États-Unis (NEC), ANSI NFPA 70 de sorte à empêcher l'humidité de s'in ltrer ou de s'accumuler dans les boitiers, conduits électriques, raccords, à l'intérieur du flotteur, ou du câble.

AVERTISSEMENT

RISQUE DE CHOC ÉLECTRIQUE Débrancher l'alimentation avant d'installer

ou d'entretenir ce produit. Seule une

personne quali ée est habilitée à installer

et entretenir ce produit selon les codes

électriques et de plomberie en vigueur.

AVERTISSEMENT

RISQUE D'INCENDIE OU D'EXPLOSION Ne pas utiliser ce produit avec des liquides

inflammables.

Ne pas installer ce produit dans des sites

dangereux tels que dé nis par le code

électrique des États-Unis (NEC), ANSI NFPA 70.

Included with alarm

Speci cations Especi caciones/Spéci cations

Alarm Power: USB Adapter:

5VDC, 200mA Max Input Voltage: 100-240VAC, 50/60Hz Output Voltage: 5VDC, 1A. Micro USB

Alimentación de la alarma: Adaptador USB:

5VDC, 200mA Max Tensión de entrada: 100-240VAC,50/60Hz Tensión de salida: 5VDC, 1A. Micro USB

L'alimentation de l'alarme: L'adaptateur USB:

5Vc.d., 200mA Max Tension d'entrée : 100-240Vc.a., 50/60Hz Tension de sortie : 5Vc.d., 1A. Micro USB

Enclosure: Gabinete: Boîtier :
Panel Module Power:

Type 1 indoor Tipo 1, cubierta Type 1, intérieur
120VAC, 60Hz

Wire Harness:

24 inches, 18 gauge

SJE RHOMBUS® FIVE-YEAR LIMITED WARRANTY
Five-Year Limited Warranty. For complete terms and conditions, please visit www.csicontrols.com.
GARANTÍA LIMITADA DE CINCO AÑOS DE SJE RHOMBUS® Cinco años de garantía limitada. Para consultar los términos y condiciones,
visite el portal www.csicontrols.com.
GARANTIE LIMITÉE SJE RHOMBUS® DE CINQ ANS
Garantie limitée de 5 ans. Pour en savoir plus au sujet des termes et conditions, visitez www.csicontrols.com.
Operation / Features Operación / Características Fonctionnement / Caractéristiques
Amber: ALM2 RF ALARM Ámbar: ALM2 RF ALARM Ambrée : ALM2 RF ALARM

CSION® RF
Alarm System / Alarma / Système d'alarme
Installation Instructions / Instrucciones de instalación / Instructions d'installation

Alarm Status Signal Strength

Pairing Button

Use this product only with the USB power supply provided.
Utilice este producto solo con la fuente de alimentación USB suministrada.
Utiliser ce produit qu'avec l'alimentation USB fournie.

Technical support: +1-800-746-6287 techsupport@sjeinc.com www.csicontrols.com
Technical Support Hours: Monday - Friday, 7 A.M. to 6 P.M. Central Time Soporte técnico, Horario: lunes a viernes, 7 A.M. a 6 P.M. hora del Centro Support technique, Horaires : du lundi au vendredi, de 7 h à 18 h Heure du Centre

Technical support: +1-800-746-6287 techsupport@sjeinc.com www.csicontrols.com
Technical Support Hours: Monday - Friday, 7 A.M. to 6 P.M. Central Time
1069213 REV A 3/2022 © 2022 SJE, Inc. All Rights Reserved. CSI CONTROLS is a trademark of SJE, Inc.

a Panel Installation Install the panel module securely in a 4X rated enclosure.

b 4X Installation Securely mount 4X enclosure. Refer to schematic for wiring panel module.

BLACK WHITE ORANGE WHITE/RED

min. 3 ft.

min. 3 ft.

DO NOT INSTALL PANEL MODULE IN TANK.

Remove CSION® alarm cover. Insert alarm module into the USB port. Mount alarm (indoor only) using keyhole on the back of the unit.

Replace cover and connect USB power cable. Refer to CSION® alarm instructions for float switch installation, battery back up, and operation.
Max 200ft.

L N Dry Contact 120VAC

Warning: only connect to dry contact closure.

Test alarm weekly to insure proper operation.

Refer to operation guide for start up.

1 2 3456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Alarm LED

CSION® RF Alarm Operation Guide

Pairing Button

Signal Strength

Step 1: Installation
Mount and wire the alarm according to the installation instructions. ***Maximum distance between modules should be 200ft.

Step 2: Signal Strength Check

Press pairing button

for 1 second on the panel module to enter setup mode for fast signal strength

updates.

Reposition the indoor module until 1 or more signal LEDs are illuminated green.

Step 3: Test Alarm

Verify the alarm is functioning by triggering an alarm condition on the outdoor panel and verify the indoor

CSION® alarm is alarming. Alarm LED on CSION® RF

and CSION® alarms will illuminate amber in

color when alarming and the audible alarm will sound. For CSION® WiFi alarm units, verify a text or email

notification of alarm was received.

Monthly Testing

Verify at least 1 or more signal LEDs are illuminated green monthly able.

, and repeat step 3 as you are

