DRAGEN TSO500 ctDNA Analysis Software

Customer Release Notes

Version V2.6.1

For TruSight Oncology 500 ctDNA Assay

Effective Date: October 11, 2024

Introduction

These Release Notes detail the key changes to software components for the DRAGEN TSO500 ctDNA v2.6.1 Analysis Software on DRAGEN server. For full details, please consult the DRAGEN TSO 500 ctDNA v2.6.1 Analysis Software User Guide available on the support website.

This software is intended for use with the TruSight Oncology 500 ctDNA and TruSight Oncology 500 ctDNA v2 assays.

  • Software Version: 2.6.1
  • DRAGEN software version 3.10.18

The software package includes:

  • dragen_tso500_ctdna_2.6.1.tar - a tar file of the DRAGEN TSO 500 ctDNA v2.6.1 Analysis Software docker image
  • dragen_tso500_ctdna_2.6.1.sif - singularity image format file of the DRAGEN TSO 500 ctDNA v2.6.1 Analysis Software
  • uninstall_DRAGEN_TSO500_CTDNA-2.6.1.sh - bash script used to uninstall DRAGEN TSO500 ctDNA
  • resources/ - workflow resource bundle for DRAGEN TSO500 ctDNA v2.6.1 Analysis Software
  • DRAGEN installer:
    • dragen-3.10.18-8.el8.x86_64.run - DRAGEN installer for Oracle Linux 8
    • dragen-3.10.18-8.el7.x86_64.run - DRAGEN installer for CentOS 7
  • check_DRAGEN_TSO500_CTDNA-2.6.1.sh - bash script used to validate DRAGEN TSO500 ctDNA installation is successful
  • install_DRAGEN_TSO500_CTDNA-2.6.1.run - script used to install TSO500 ctDNA
  • DRAGEN_TSO500_CTDNA-2.6.1.sh - bash script used to launch DRAGEN TSO 500 ctDNA

NEW FEATURES:

No new features

FIXED ISSUES:

  • Fixed an issue related to fusion calling sensitivity for samples with high number of candidate Structural Variants (SVs). SV calling involves 3 steps: 1) genome-wide graph generation of coarse resolution SV candidates, merging and filtering 2) refinement of SV candidates and 3) DNA Fusion Filtering (DNAFF). Samples that generate high number of candidate SVs, including but not limited to samples that have high number of chimeric reads or high library prep conversion efficiencies, may have had missed calls in previous software versions (v2.1.1 to v2.6.0) due to filtering of low-support SV candidates. The updated SV caller enhances the graph merging and filtering processes to recover previously missed SVs, reducing false negatives.

KNOWN ISSUES:

  • There are minor differences in outputs of exon_cov_report and gene_cov_report from DRAGEN TSO 500 Analysis Software on ICA and DRAGEN server/NovaSeq 6000Dx Analysis Application
  • NTC sample (No-Template Control samples with 0 reads) is marked as 'False' (under the header 'Completed_All_steps') in the metrics output file instead of being marked 'TRUE'.
  • Moving or modifying files during the analysis may cause the analysis to fail or provide incorrect results.
  • Using control-c during a running analysis may cause an FPGA error. To recover from an FPGA error, shut down and restart the server.
  • The sample sheet should not have blank rows between samples in the [Data] section, this may cause a run failure.
  • Performance not verified using reads other than 2 x 151, paired end, dual index.
  • The software does not notify the user when InterOp files for RunQC are missing or corrupted.
  • Analysis fails when starting from V1 sample sheets due to missing adapter sequences in V1 sample sheet template. Users are recommended to start with V2 sample sheet template or add adapter sequences manually.
  • Pipeline does not exit early and continues to the next DragenCaller step due to TSO500 ctDNA FASTQ validation failure if Fastq_list.csv is missing.
  • High chimeric read count results in incorrect TMB calculation.
  • In the V2 CNV cutoff bed file, gene “MYCL” should be listed instead of "MCYL1”.
  • Variant consequences are not assigned consistently for co-occurring variants when stop_gained is introduced.

PRODUCT LIMITATIONS:

  • The sample sheet must be configured as described in the provided templates, User Guide or by using BaseSpace Run Planning tool.
  • Sample sheets generated for auto-launch on ICA are not compatible and cannot be reused without changes for DRAGEN TSO500 ctDNA Analysis Software on a Local DRAGEN server, and vice versa.
  • The values in the Run Metrics section will be listed as `NA' if the analysis was started from FASTQs or if the analysis was started from BCLs but the InterOp files are missing or corrupted.
  • Germline estimation uses the latest publicly available population data and is estimated to be representative of targeted population, the impact of rare germline mutations is expected to be limited.
  • The Illumina Annotation Engine (aka Nirvana) may report incorrect HGVS c. and HGVS p. notation for small variants occurring in RefSeq transcripts that exhibit transcript sequences differing from the genomic reference (i.e., RNA-edits). Currently the HGVS c. error rate is 0.00527% and the HGVS p. error rate is 0.00737%.
  • The CNV caller has slightly higher noise for sample types that are not included in the baseline used for normalization (eg., cell lines). The baseline samples consist of mostly healthy donor clinical samples and SeraCare-contrived samples.
  • MSAF output has had limited testing and needs to be used with caution. Updates to the small variant calling have led to an increased MSAF in samples with higher DNA input.

Release History

RevisionRelease ReferenceOriginatorDescription of Change
00CN 1114085Svetlana BureevaInitial Release
200062148 00 DRAGEN TSO 500 ctDNA v2 6 1 Analysis Software Customer Release Notes Microsoft Word 2019

Related Documents

Preview DRAGEN TSO 500 ctDNA Analysis Software on ICA v2.6.1.8 Release Notes
Release notes for the DRAGEN TSO 500 ctDNA Analysis Software on ICA, version 2.6.1.8. Details new features, fixed issues, and known limitations for the TruSight Oncology 500 ctDNA Assay.
Preview Illumina DRAGEN TSO 500 ctDNA v2.6.0 Software Release Notes for TruSight Oncology 500 Assay
Release notes for Illumina's DRAGEN TSO 500 ctDNA Analysis Software v2.6.0, detailing new features, fixed issues, known issues, and product limitations for the TruSight Oncology 500 ctDNA assay.
Preview DRAGEN TSO 500 Analysis Software v2.1.1 on ICA Release Notes
Release notes for DRAGEN TSO 500 Analysis Software v2.1.1 on Illumina Connected Analytics (ICA), detailing new features, improvements, defect repairs, known issues, and product limitations for use with TruSight Oncology 500 and TruSight Oncology 500 HRD assays.
Preview DRAGEN TSO 500 Analysis Software v2.6.2 Release Notes | Illumina
Detailed release notes for Illumina's DRAGEN TSO 500 Analysis Software v2.6.2, covering new features, bug fixes, known issues, and product limitations for TruSight Oncology assays.
Preview Illumina DRAGEN TSO 500 Analysis Software v2.5.3 Release Notes - Software Updates and Fixes
Illumina DRAGEN TSO 500 Analysis Software v2.5.3 release notes detailing new features, bug fixes, known issues, and product limitations for TruSight Oncology 500, HRD, and High-Throughput assays.
Preview DRAGEN TruSight Oncology 500 Analysis Software v1.1 on ICA User Guide
User guide for Illumina's DRAGEN TruSight Oncology 500 (TSO 500) Analysis Software v1.1 on Illumina Connected Analytics (ICA) v2. Covers setup, analysis modes (Graphical, CLI), DNA and RNA analysis methods, output folder structures, and revision history.
Preview DRAGEN TSO 500 Analysis Software v2.1.0 Release Notes
Release notes detailing changes, new features, defect repairs, known issues, and product limitations for the DRAGEN TSO 500 Analysis Software version 2.1.0, used with TruSight Oncology 500 and TruSight Oncology 500 HRD assays.
Preview DRAGEN TruSight Oncology 500 ctDNA Analysis Software v1.2 on ICA User Guide
User guide for the DRAGEN TruSight Oncology 500 ctDNA Analysis Software v1.2 on Illumina Connected Analytics (ICA) v2, detailing setup, analysis modes, configuration, methods, and output structures for research use.