User Manual for MIDNITE SOLAR models including: MNPowerflo 16 16 Kwh 48Volt Wall Floor Mount LFP Battery, MNPowerflo 16, 16 Kwh 48Volt Wall Floor Mount LFP Battery, Wall Floor Mount LFP Battery, Mount LFP Battery, LFP Battery, Battery

6613-10-000051 说明书MNPowerflo16 A1最新

Download

Midnite Solar MNPowerflo16 - Inverter Supply

[PDF] MNPowerflo 16 - MidNite Solarwww.invertersupply.com › data

6613-10-000051 说明书MNPowerflo16 A1最新


File Info : application/pdf, 14 Pages, 31.19MB

PDF preview unavailable. Download the PDF instead.

MNPowerflo16
LITHIUM BATTERY
MNPowerflo 16
USER MANUAL

CONTACT US
support@midnitesolar.com www.midnitesolar.com

© 2024 MIDNITE SOLAR INC ALLRIGHTS RESERVED. VERSION V1.2.0-beta| CONTENT SUBJECT TO CHANGE WITHOUT NOTICE. MODEL #:MNPowerflo 16

TABLE OF CONTENTS
1. TECHNICAL SPECIFICATIONS SHEET....................................................................................... 2 2. ABBREVIATIONS ........................................................................................................................ 3 3. SAFETY........................................................................................................................................4
3.1 SAFETY INSTRUCTIONS....................................................................................................4 3.2 IMPORTANT SAFETY NOTIFICATIONS .............................................................................4 4. BRIEF INTRODUCTION ...............................................................................................................6 4.1 PRODUCT DESCRIPTION .................................................................................................. 6 5. PACKING LIST............................................................................................................................ 7
6. LOCATION SELECTION AND INSTALLATION .......................................................................... 8 6.1 MNPowerflo 16 INSTALLATION ....................................................................................... 9
7. BATTERY WIRING .................................................................................................................... 13 7.1 BATTERY PARALLELING COM MUNICATION WIRING GUIDE .................................... 13 7.2 BATTERY WIRING DIAGRAM AND GUIDE ................................................................... 14 7.3 BPARALLEL SYSTEM WIRING DIAGRAMS..................................................................... 15 7.4 POWER ON SEQUENCE ............................................................................................... 18 7.5 POWER OFF SEQUENCE ........................................................................................ 18 7.6 BATTERY CHARGING .................................................................................................... 19
8. TROUBLESHOOTING, MAINTENANCE & DISPOSAL ............................................................. 20 8.1 INTRODUCTION TO THE BMS ..........................................................................................2.0 8.2 BMS PROTECTION........................ .................................................................................. 20 8.3 TROUBLESHOOTING....................................................................................................... 21 8.4 BATTERY DISPOSAL ....................................................................................................... 23
9. MidNite 15 YEARS LIMITED WARRANTY ................................................................................ 23 9.1 WARRANTY EXCLUSIONS ............................................................................................. 23
10. STORAGE ................................................................................................................................. 24

Symbols on labels, manuals, and products
Do not reverse the Positive and Negitive connection. N'inversez pas la connexion positive et négative.
Do not place near open flame. Ne pas placer près d'une flamme nue.
Keep out of reach of children and pets. Ne placez pas l'appareil dans la zone de contact des enfants et des animaux domestiques.
Warning electric shock. Avertissement de choc électrique.
Fire Warning. Do not place near flammable material. Avertissement d'incendie. Ne placez pas à proximité de matériaux inflammables. Read the product and operation manual before operating the battery system! Lisez le produit et le manuel d'utilisation avant d'utiliser le système de batterie!
Grounding. Système de mise à la terre.
Recycle label.
Label for Waste Electrical and Electronic Equipment (WEEE) Directive (2012/19/EU)

1. TECHNICAL SPECIFICATIONS SHEET

Product Name Electrical Characteristics
Nominal Voltage Nominal Capacity Energy Battery Chemistry Cycle Life Operating Voltage Communication Interfaces Scalable
Charge&Discharge
Nominal Charging Current Nominal Discharging Current Max. Discharging Current
Environmental
Environment Charging Temperature Discharging Temperature Storage Temperature Altitude Cooling Method IP Rating
Mechanical
Dimension(L x W x D) Weight Installation

MNPowerflo 16
51.2V 314Ah 16,076Wh Lithium Iron Phosphate (LFP) 8,000 cycles @77°F(25°C), 0.5C/0.5C 46.4~57.6V CAN/RS485/RS232 Up to 16 units
160A 160A 210A
Outdoor, Indoor -4°F to 122°F (-20°C to 50°C)* -4°F to 122°F (-20°C to 50°C)
14°F to 113°F (-10° C to 45°C) Maximum 9,843 ft (3,000 m)
Natural Convection IP65
31.50 x19.69x8.94in(800*500*227mm) 284lbs(128.9kg)
Wall mount or Floor mount

* When the ambient temperature is below 32°F (0°C), the internal heating pads start to operate. The battery begins charging when the cell temperature is between 32°F and 122°F (0°C and 50°C).

2. ABBREVIATIONS
A ­ Amp(s) AC­ Alternating Current Ah ­ Amp hour(s) AHJ­ Authority Having Jurisdiction ANSI­ American National Standards Institute AWG­ American Wire Gauge BAT­ Battery BMS ­ Battery Management System COM­ Communication CT­ Current Transformer DC­ Direct Current DOD­ Depth of Discharge EG ­ Equipment Ground EGS­ Equipment Grounding System EPS ­Emergency Power System ESS ­Energy Storage System E- Stop NO­ Emergency Stop Normally Open FCC­Federal Communication Commission GE ­Grounding Electrode GEC­Grounding Electrode Conductor GEN ­Generator GES­Grounding Electrode System GFCI­Ground Fault Circuit Interrupter GFDI ­Ground Fault Detector/Interrupter IEEE­Institute of Electrical and Electronic Engineers Imp ­ Maximum Power Point Current In. lbs. ­ Inch Pounds IP ­ Ingress Protection Isc ­ Short- Circuit Current

kW ­ Kilowatt kWh ­ Kilowatt - hour L1­ Line 1 L2 ­ Line 2 LFP­ Lithium Iron Phosphate or LiFePO4 mm ­ Millimeter(s) MPPT­ Maximum Power Point Tracker ms ­ Millisecond(s) mV ­ Millivolt(s) NEC­ National Electrical Code NEMA­ National Electrical Manufacturers Association NFPA­ National Fire Prevention Association Nm ­ Newton Meters NOCT­ Normal Operating Cell Temperature PC­ Personal Computer PCB­ Printed Circuit Board PE­ Protective Earth (G or Ground) PPE­ Personal Protective Equipment PV­ Photovoltaic RSD­ Rapid Shut Down SCC­ Standards Council of Canada SOC­ State of Charge STC­ Standard Testing Conditions UL ­ Underwriters Laboratories UPS­ Uninterrupted Power Supply V ­ Volt(s) VMP ­ Voltage Maximum Power VOC­ Open- Circuit Voltage

3. SAFETY
3.1 SAFETY INSTRUCTIONS
International safety regulations have been strictly observed in the design and testing of the battery. Before beginning any work, carefully read all safety instructions, and always observe them when working on or with the battery. The installation must follow all applicable national or local standards and regulations. Incorrect installation may cause:
injury or death to the installer, operator or third party damage to the battery or other attached equipment

3.2 IMPORTANT SAFETY NOTIFICATIONS

DANGER!

Hazardous Voltage Circuits!

AVERTISSEMENT! Circuits à tension élevée!

There are various safety concerns that must be carefully observed before, during, and after the installation, as well as during future operation and maintenance. The following are important safety notifications for the installer and any end users of this product under normal operating conditions.
1. Beware of high PV voltage. Please install an external DC disconnect switch or breaker and ensure it is in the "off" or "open" position before installing or working on the battery. Use a voltmeter to confirm there is no DC voltage present to avoid electric shock.
2. Beware of high grid voltage. Please ensure the AC switch and/or AC breaker are in the "off" or "open" position before installing or working on the battery. Use a voltmeter to confirm there is no voltage present to avoid electric shock.
3. Beware of high battery current. Please ensure that the battery module breakers and/or on/off switches are in the "open" or "off" position before installing or working on the battery. Use a voltmeter to confirm there is no DC voltage present to avoid electric shock.
4. Do not open the battery while it is operating to avoid electric shock and damage from live voltage and current within the system.
5. Do not make any connections or disconnections (PV, battery, grid, communication, etc.) while the battery is operating.
6. An installer should use personal protective equipment (PPE).
7. Before installing, operating, or maintaining the system, it is important to inspect all existing wiring to ensure that it meets the appropriate specifications and conditions for use.
8. Ensure that the PV, battery, and grid connections to the inverter are correct to prevent damage or injuries caused by improper installation.

WARNING : To reduce the risk of injury, read all instructions
All work on this product (system design, installation, operation, setting, configuration, and maintenance) must be carried out by qualified personnel. To reduce the risk of electric shock, do not perform any servicing other than those specified in the operating instructions unless qualified to do so. 1. Read all instructions before installing. For electrical work, follow all local and national
wiring standards, regulations, and these installation instructions. 2. Make sure the battery is properly grounded. All wiring should be in accordance with the
National Electrical Code (NEC), ANSI/NFPA 70. 3. The battery and system can inter - connect with the utility grid only if the utility provider
permits. Consult with the local AHJ before installing this product for any additional regulations and requirements for the area. 4. All warning labels and nameplates on this batte ry should be clearly visible and must not be removed or covered. 5. The installer should consider the safety of users when choosing the battery 's correct position and location as specified in this manual. 6. Please keep children away from touching or misusing the battery and relevant systems. 7. Beware! The battery and some parts of the system can be hot when in use. Use Caution if you touch the battery 's surface or parts when they are operating.
DISCLAIMER MidNite reserves the right to modify the content herein at any time without prior notice. For the latest versions of our manuals and specification sheets, please visit www.midnitesolar.com.

4. BRIEF INTRODUCTION
Battery Features
° IP65 all-weather rated, integrated self - heating during low ambient temperatures. ° Active balancing of cells enhancing the battery consistency and the lifespan up to 20 years
with over 8000 cycles (at an operating temperature of 77°F [25°C]). ° Built - in intelligent BMS with battery voltage, current, temperature, and health management
to reduce electrical risks and overheating . ° Communicate with inverter using CAN or RS485. Firmware update using RS485 ° High-reliability 250A DC connector.
° Stable, reliable, and maintenance free battery pack. ° Comprehensive safety UL1973, UL9540A, UL9540 on cell and module level with enhanced
onboard fire-extinguishing modules.
4.1 PRODUCT DESCRIPTION
The MNPowerflo 16 batteries are ideal for low- voltage residential outdoor energy storage system (ESS) applications. These batteries use lithium iron phosphate cells with the highest safety performance and an intelligent Battery Management System (BMS) that can monitor and record the voltage of each cell, along with the current, voltage, and temperature of the module in real- time. The BMS also contains an active balance function and an advanced battery control method, both of which improve the performance of the battery pack. For enhanced security, the battery is equipped with onboard fire extinguishing devices. With a design life of more than 20 years , the Wall Mount is designed for over 8000 cycles (at an operating temperature of 77°F [25°C]).

5. PACKING LIST
The items listed below are included with the purchase:

MNPowerflo 16 1PC

Wall mounting bracket 2PCS

Concrete expansion bolts 8PCS

RJ45 connector Communication network cable

4PCS

2PCS

Mounting template Crimp terminal Yellow-green two-color Ground connection fixing DC terminal fixing screw Wall-mount bracket fixing

1PC

for 2/0 AWG

grounding cable

screw M5*12mm

M8*16mm

screw M4*16mm

2PCS

1PC

1PC

2PCS

4PCS

Battery Overview

19-3/4inch(500mm)

8-7/8inch(227mm)

31-1/2inch(800mm)

Figure 1-Battery Cross -Sectional View

DANGER:When installing or removing battery, ensure battery is in the off position, and
use a voltmeter to confirm there is no voltage present. This will prevent users from encountering live (powered) terminals by accident. Failure to do so can result in severe injury and/or death.
LOCA TION SELECTION AND INSTALLATION
WARNING
° Do not stack MNPowerflo 16 batteries in series The BMS and internal components are not designed to handle this setup, which could cause the modules to fail.
° The WallMount battery is heavy. Use a lift or other equipment to lift and carry the unit. ° The battery can be installed against a flat wall, but the weight of the battery should not be fully supported by the wall. To help with this requirement, the battery comes with pre-installed feet that should be used to allow some of the weight of the battery to rest on the ground. ° When installing on a wall, the wall must be made of non-combustible material. If this is not possible, then the unit MUST have a minimum of 2 in. (50.8mm) of clearance from the wall to prevent heat transfer to the wall surface. All materials within the 2 in clearance, must be a non combustible material.
° If installing on flat ground, ensure there is proper drainage surrounding the battery to prevent damage from flooding. If installing against a wall, ensure at least a 12 in. gap on each side of the unit for adequate airflow and operations.
° Always mount the battery in an upright position.

° Ensure at least 12in between multiple WallMount batteries and other devices. ° Please follow NEC and other local codes while installing the product.

12inch

12inch

12inch

12inch

12inch

Figure 2 ­ Clearance Diagram
6.1 MNPowerflo 16 INSTALLATION
Wiring compartment is at the top of the battery. Please remove the top cover before installation.

STEP 1
Use the included 1:1 scale paper mounting template on the wall to help determine the bracket drilling positions.
18-1/2inch(470mm) 16inch(406.4mm) 8inch(203.2mm)

STEP 3
Hang the MNPowerflo 16 battery on the wall mounting bracket and secure it tightly.
Fastening Screw

3inch(76mm)

STEP 2
Secure the mounting bracket.
Mounting bracket(upper part) Mounting bracket(lower part)

STEP 4
Connect to the ground.
Ground

STEP 5
Connect the power cable and communication cable, note that the power cable needs to be securely fixed.

Link in

CAN

Link Out

To inverter BMS port

To inverter BAT+ teminal To inverter BAT- teminal
234

7

Link in

CAN

Link Out

P+

P-

8

1

6

5

NO

ITEM

1

Positive terminal

2/4 Battery-Comm ports

3

CAN/RS232 port

5

Negative terminal

6

Ground screw

7

Circuit breaker

8

POWER button

DESCRIPTION M8 bolt (x1)
Parallel battery communication port
CAN/RS232 communication interface
M8 bolt (x1) Provides safe route for grounding
Shuts down power supply Turn BMS on/off

REMARKS
-
Pin3-RS485_B / Pin2-RS485_A Pin 4-CAN_H / Pin 5-CAN_L
Pin 6-RS232_RX / Pin 7-RS232_GND / Pin 8-RS232_TX -
-
-
-

7. BATTERY WIRING
WARNING
Be sure the battery packs are powered "OFF" before making/removing any connections. Use two 2/0 Awg (70mm) outdoor rated positive and negative battery cables (not included) with Hydraulic crimped ring terminals and heat shrink insulation. When paralleling batteries, the battries can be terminated in a combiner box or bussbar rated for the number of inverters being installed.
When paralleling batteries, use a communication cable to connect the master battery to slave batteries for battery-to-battery communication. This cable is a standard RJ45 Cat 5 computer cable.
7.1 BATTERY PARALLELING COMMUNICATION WIRING GUIDE
1. Ensure all battery breakers and BMS are OFF. 2. Set up communication between the batteries via the "Battery - Comm" ports of each battery.
Use the paralleling kit communication cable to daisy chain all paralleled batteries in the bank together. See diagram below for example.
Connected to the inverter

Link In

CAN

Link Out

Link In

CAN

Link Out

Link In

CAN

Link Out

3. If the communication of one battery is connected to the inverter, then that battery is the master unit.
4. Install battery paralleling cables between batteries. Refer to Section 8.2 Battery Cable Connections for battery cable connection diagram examples.
5. Once all cable connections are completed and the system is ready to be commissioned, power on each battery breaker and BMS ON/OFF switch one at a time beginning with the master battery.
Battery automatically assigns addresses. No dip switch programing required.

7.2 BATTERY WIRING DIAGRAM AND GUIDE
The following battery wiring diagrams are examples using the external busbars to parallel the batteries together and connect the inverter(s) to the batteries.
Systems with more batteries than these configurations require the use of an external fused positive busbar and an unfused negative busbar rated at a minimum of 210A per battery. Each fuse should be a maximum of 250 A. Alternatively, larger systems could rely on the MN15-12KW-AIO ability to draw from different battery packs while still paralleling inverters rather than utilizing external busbars.
The maximum recommended number of paralleled MN15-12KW-AIO inverters is 9. If this approach is used, we recommend a ratio of 2 batteries per pack controlled by each MN15-12KW-AIO inverter. Separating packs is only recommended if each pack's average SOC is monitored over time and does not diverge by more than 10%.Refer to NEC code and the local AHJ for exact requirements. If installing one MN15-12KW-AIO inverter and one MNPowerFlo 16 battery, you must use a pair of 4/0 copper battery cables if not using a bussbar.
NOTE:In the following diagrams, units are spaced 12 in. apart. Local regulations may require
a larger minimum battery spacing. Check with the local AHJ for these requirements.
Single battery install must use 4/0 AWG Copper Battery cable
Pro Tip:One MN15-12KW-AIO MNPowerflo 16 and a minimum of 2 WallMount units is the recommended configuration to maximize the system's functionality.
Figure 3 ­ (1) MN15-12KW-AIO (1) MNPowerflo 16

7.3 Parallel System Wiring Diagrams

COMBINER BOX

+

-

Note: Some configurations require additional wiring/connectors to achieve the example layouts. Inverter to inverter paralleling cables are not shown in the following diagrams. Other configurations can be achieved by using external busbar s. Please seek the guidance of an electrician or qualified person for optional system layout.

Figure 4 ­ (1) MN15-12KW-AIO (2) MNPowerflo 16

COMBINER BOX

+

-

Reminder! The separation between batteries should be12 in. (add to Reminder) The MN15-12Kw-AIO must use 4/0 AWG battery cables for connection to the battery of Busbars

Figure 5 ­ (1) MN15-12KW-AIO (3) MNPowerflo 16

COMBINER BOX

+

-

Figure 6 ­ (2) MN15-12KW-AIO (2) MNPowerflo 16

COMBINER BOX

+

-

Figure 7 ­ (2) MN15-12KW-AIO (3) MNPowerflo 16

COMBINER BOX

+

-

Figure 8 ­ (3) MN15-12KW-AIO (3) MNPowerflo 16

7.4 POWER ON SEQUENCE
Step1: Check Equipment:  Ensure that the installation and connections of the battery and related equipment are correct.  Make sure there are no obstructions around the system and that it is well-ventilated.  Check that all cables and connections are secure.
Step2: Turn on Battery Breaker:  Turn the battery pack breaker ON, see if lights on the battery are active.
Step3: Start the Battery Management System (BMS):  Press and hold the POWER button for 3 seconds.
Step4: Turn on the Inverter:  Turn on the power switch of the inverter and wait for it to complete its startup.

7.5 POWER OFF SEQUENCE

Step1: Turn off the Load:  Disconnect all connected load devices and ensure the load is completely turned off.

Step2: Turn off the Inverter:  Turn off the power switch of the inverter and ensure the inverter has completely stopped operating.

Step3: Turn off the Battery Breaker:  Finally, turn off the breaker of the battery pack to ensure the battery pack is powered off.

BREAKER

Step4: Turn off the Battery Management System (BMS):  Press and hold the POWER button for 3 seconds. Turn off the Battery Management System.

POWER

Notes  Maintain Safety: When operating electrical equipment, Use appropriate safety measures, such as
wearing insulated gloves and ensuring hands are dry.  Regular Maintenance: Check and maintain the energy storage system to ensure its long-term stable
operation.

7.6 BATTERY CHARGING
Charge cycle
Ensure the proper settings are set on the charge controller and/or inverter being used to avoid overcharging or damaging the module. ( Refer to Section 1: Technical Specifications Table for a full list of charging/discharging parameters.)

IMPORTANT
It is normal for LFP batteries with internal BMS and that are wired in parallel to demonstrate a variety of SOC readings during charge or discharge cycles. bold txt. This is not cause for concern or indication that the module is providing less than the maximum capacity. This is caused by even slight variations in wiring resistance to each battery, internal resistance, temperature differences, and even variations in each cell. Even a slight variation causes one battery to take more of the load or charge for a short time. Over the duration of the discharge or charge cycle, this will balance out with the lagging battery then taking the load or charge at the other end of the cycle resulting in recovering the full listed kWh capacity of the pack. The voltage differences created as batteries diverge in SOC will eventually cause them to converge at some point in the cycle.

Recommended Charge Current Settings for Paralleled Batteries on Paralleled MN15-12KW-AIO

# of MN1512KW-AIO

Rec. Max. Charge Current
(230A per inverter)

(1) Battery Inverter Setting ­ Amps per Battery

(2) Batteries Inverter Setting ­ Amps per Battery

(3) Batteries Inverter Setting ­ Amps per Battery

(4) Batteries Inverter Setting ­ Amps per Battery

1

210A

160-160A

210-160A

210-70A

210-52A

2

420A

80-160A

160-160A

210-140A

210-105A

3

630A

53-160A

107-160A

160-160A

210-160A

Please note that the maximum allowed charging current for a single battery is 210A, the internal thermal sensors will throttle the charge current to what the BMS deems necessary to prevent overheating.

8. TROUBLESHOOTING, MAINTENANCE & DISPOSAL
8.1 INTRODUCTION TO THE BMS
The BMS (Battery Management System) is intended to safeguard the battery and battery cells against a variety of situations that could damage or destroy system components. This protection also aids in keeping the battery and battery cells operational for a greater number of life cycles. Each MNPowerflo 16 battery is specifically configured to ensure peak performance and operation with any inverter system.
8.2 BMS PROTECTION
PCB temperature protection The BMS will ensure that the Printed Circuit Board (PCB) does not overheat. This is the component that houses most of the "brains" of the battery. This feature will turn off the battery if it begins to overheat.
Cell balance protection Cell balance ensures that each cell is within a specific voltage range of each other. Cell balance is crucial for ensuring that the battery is operating properly for its lifespan. This is always done Automatically.
Environmental temperature protection It may be dangerous to attempt using the battery in extreme heat or cold. Continued operation in these conditions may result in permanent damage to the battery module and its components. To prevent this, the BMS is designed to measure the temperature while charging/discharging and will shut down the battery to prevent damage.
Voltage protection The BMS is designed to continuously monitor the voltage of each individual cell and ensure that they are not over/undercharged.
Current protection The BMS is designed to constantly monitor the charge/discharge amperage and has built-in safeguards against exceeding specific parameters. These include built-in timers that shut off quickly in the event of short circuits, extremely high amperage and delayed shut down for amperage that is only slightly above the maximum capacity.

8.3 TROUBLESHOOTING
Alarm Description and Troubleshooting. When the Alarm light on the battery control panel is on, it means that the battery has given an alarm or has been protected from potential damage.

FRONT PANEL INDICATOR LIGHTS
Run/Alarm LIGHTS The MNPowerflo16 battery features 2 LED status indicator lights on the front panel of the unit. Their functions are listed below:

Alarm-The Alarm light indicates a static, red color and powers on when a fault occurs. Please refer to the table below for more information on specific faults and required actions.

L8

L6

L5 L4

Run -The Run light will indicate a solid, green color when the

L7

L3 L2

battery is in an idle state. When the battery is either charging or

L1

discharging, the light will indicate a blinking, green color.

Light Description

Indication

Color

Indication Description

Alarm

Static

Red

A fault has occurred

Static Green Battery is in the idle state

Run

Blinking

Green

Battery is charging/discharging

SOC INDICATOR LIGHTS The battery also features an LED capacity gauge to indicate the SOC (state of charge). The table below provides the detailed logic of the LED lights.
LED status

Battery SOC Levels (%)

Blinking(Charging) /Light(Other)
Blinking(Charging) /Light(Other)
Blinking(Charging) /Light(Other)
Blinking(Charging) /Light(Other)
Blinking(Charging) /Light(Other)
Blinking(Charging) /Light(Other)

Note: In a system with multiple batteries connected in parallel, only the power gauge of the master battery will be activated. The master battery's power gauge represents the SOC of the entire battery system, and the gauges of the other batteries will not be activated. If the battery is not stacked properly, the battery display will be activated. Please check your cable connections and placement again.

NOTE: lf any fault from the table below persists, please contact the distributor or
MNS for additional troubleshooting.

Fault
Inverter communication failure
No DC output
Power supply unstable
Battery can not be charged fully
Alarm LED always on

Analysis
Check communication port connection, and battery ID
setting. Open breaker, or battery
voltage is too low. Battery capacity is not at full
power.
DC output voltage is below the minimum charge voltage.
Short circuit

Action
Check the connections and settings, then restart the battery
Check battery breaker or charge the battery.
Check for proper battery cable connection.
Check the charging settings on the inverter to ensure they match battery requirements.
Disconnect the power cable and check all cables.

The battery output voltage Battery management system Press the reset button to reset the

is unstable.

does not operate normally.

battery, then reboot the system.

Alarm LED flashes 20 times Unbalanced voltage within a

with SOC1 LED on.

cell

Alarm LEDflashes 20 times with SOC2 LED on.
Alarm LED flashes 20 times with SOC 3/4 LED on.
Different SOC value of batteries in parallel operation.
Low voltage protection with no LED on

Unbalanced temperature
BMS damaged
No issue
BMS is in low voltage protection, and is in sleep
mode

Deep discharge the battery bank (<20% SOC), then charge battery
bank fully.
Contact the distributor.
Contact the distributor.
Deep discharge the battery bank (<20% SOC), then charge battery
bank fully.
Contact the distributor.

Deeply discharged with The battery voltage is too low

"RUN" LED on

to start BMS.

Contact the distributor.

8.4 BATTERY DISPOSAL
The MNPowerflo 16 battery is designed to last for more than 20 years when used correctly. We have worked tirelessly to ensure that our batteries will maintain a charge after thousands of cycles. However, when it does come time to retire the battery, there are a few things to consider. Lithium iron phosphate batteries are considered a hazardous material and should not be disposed of by simply placing them in the trash. There are several websites and organizations that will accept this battery to recycle at little to no cost to the user. At MidNite, we understand that we are working with customers across the United States and the world. Our recommendation is to go online and search the term "Lithium Battery Disposal Near Me." There will likely be an assortment of organizations that can safely dispose of LFP batteries. We recommend calling ahead of time to ensure that the location is still open and accepting material. If users are unable to locate a disposal location safely, MidNite is here to help. Before dumping the battery or disposing of it incorrectly, please contact our customer service team for assistance.
9. MidNite 15 YEARS LIMITED WARRANTY
The warranty must be registered within the first year of purchase to remain valid. If users choose not to register the product, the warranty may be invalidated. This limited warranty is to the original purchaser of the product and is not transferable to any other person or entity. All BMS and cell exchanges are covered throughout the warranty period. If a full replacement warranty is needed the warranty is prorated 1/14th per year after the first year at the current retail pricing.
9.1 WARRANTY EXCLUSIONS
Under this limited warranty, MidNite Solar has no obligation to the product if it is subject to the following conditions, including but not limited to:
· Damages incurred during installation or removal · Damages caused during mishandling of product · Inappropriate environmental exposure · Damages caused by improper maintenance · Unauthorized tampering, altering, and/or disassembly of product · Using the product for purposes other than those intended by the manufacturer · Lightning, Fire, Flood, or Acts of God · Any product whose serial number has been altered, defaced, or removed
The equipment sold by MidNite Solar is designed to be installed only by licensed, trained, and insured solar electrical installation professionals. We strongly advise customers to seek the assistance of such a professional to implement these products, and we make no warranty of the purchaser's safety, success of equipment implementation, or compliance with local codes and regulations.
MidNite Solar disclaims all additional warranties, expressed or implied, including but not limited to, any implied warranty with respect to the accuracy or completeness of the information they disseminate and/or fitness of the materials sold for a parti cular purpose. No warranty may be created or extended by sales or promotional materials on these items. Each party hereby irrevocably waives its rights to trial by jury in any action or proceeding arising out of this agreement or the transactions relating to its subject matter. All installation advice provided by MidNite before, during, or after purchase of solar equipment is purely for the purpose of general concept education and must not replace the expertise of a licensed and trained solar specialist. The customer agrees to full indemnification for MidNite henceforth from any legal recourse relating to and arising out of losses, direct or consequential, from the installation of the products purchased by the customer more than the value of the equipment purchase price.

10.STORAGE
Please follow these instructions for the safe storage of the unit to maintain the longevity of the battery, if choos ing not to install the product immediately after purchasing or unpacking the box.
There are a few steps that can be taken to ensure that batteries are stored safely and in a state that will ensure they are not damaged during storage. The steps are detailed below.
Battery State
The state of the battery when placed into storage will affect how long it can be stored as well as the battery's condition when it is brought out of storage. MidNite recommends that each battery is brought to a 100% SOC (state of charge) before placing it in storage. Lithium batteries will lose a certain percentage of their total charge while in storage, depending on how long they are stored and the conditions they are stored in. We recommend recharging the batteries after 8 ­9 months in prolonged storage.
Environmental Factors
The environment the battery is stored in can greatly affect the health of the battery. For best results, the temperature should range between 33°F and 90°F (0.6°C and 32°C). Mount the battery in a location where it is not exposed to direct rain, standing water and ensure the battery is mounted on non combustible material. Keep the battery away from direct sunlight. Store the batteries away from combustible materials.



References

Adobe PDF library 16.03 Adobe Illustrator 26.0 (Windows)