ALTAIR V5 CONCENTRIC ROTARY PISTON METER
by DIEHL Metering
APPLICATION
The ALTAIR V5 CONCENTRIC is the latest generation of volumetric water meters specifically designed for installation on a coaxial base in a manifold. It adapts to the most demanding environments and varying water qualities while maintaining its excellent metrology. Developed within the MID framework, it complies with European standards and holds certificates of sanitary conformity.
The modular ALTAIR V5 CONCENTRIC can be fitted at any time with an IZAR clip-on module, converting it into a communicating meter. This enables mobile reading (walk-by, drive-by, passive drive-by) or fixed network reading (radio/wired).
FEATURES
- Q3 = 2.5 m³/h / Q3 = 4 m³/h
- MID approval up to R=1000
- Starting flow rate at 0.4 l/h (for Q3 = 2.5 m³/h and Q3 = 4 m³/h)
- Composite or brass body
- Cold water
METROLOGICAL DATA
R standard*Parameter | Unit | DN | 15 | 20 |
---|---|---|---|---|
Permanent flow rate | Q3 | m³/h | 2.5 | 4 |
Q3/Q1 | 160 | 160 | ||
Body | brass / composite | brass / composite | ||
Starting flow rate | l/h | 0.4 | 0.4 | |
Minimum flow rate* | Q1 | l/h | 15.62 | 25 |
Transitional flow rate* | Q2 | l/h | 25 | 40 |
Overload flow rate | Q4 | m³/h | 3.125 | 5 |
Head loss at Q3 | bar | 0.32 | 0.61 | |
Head loss at Q4 | bar | 0.50 | 0.94 | |
Kvs (deltaP=Q2/Kvs²) | 5.13 | 5.13 |
*Other values on request
APPROVAL
ALTAIR V5 CONCENTRIC
- MID Approval: LNE-39018 | Type A3
- Standards: EN 14154 | ISO 4064 | OIML R49
- Sanitary conformity: ACS AOC DEU | WRAS
REACH
Information pursuant to Article 33 (1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006:
This product series contains components with the following substances in a concentration of more than 0.1% weight by weight (w/w):
- Lead (CAS no.: 7439-92-1)
TEMPERATURE AND PRESSURE
Parameter | Unit | Value |
---|---|---|
Water temperature | °C | 0.1 ... +50 |
Ambient operating temperature | °C | +1 ... +55 |
Storage temperature | °C | -10 ... +55 |
Nominal pressure | bar | 16 |
DIMENSIONS
Height: 113.2 mm
Width: 91.3 mm
Thread connections: 1"1/2 inch
Weight (brass version): 0.82 kg
Weight (composite version): 0.39 kg
PRECISION CURVE
Q3 = 2.5 R160
Q3 = 4 R160
A special wrench is required for fitting or removing the meter (contact Diehl Metering). The two seals remain on the meter when it is removed.
OPTION
- Plastic register
Economic Actor Information
Applicable regulation and legal obligations for products may change. DIEHL METERING monitors applicable regulation to ensure their products comply at the date of placing on the market. Each economic actor making products available on the market thereafter must independently keep informed about the current applicable regulation.
For questions, please contact: metering-germany-info@diehl.com