Instruction Manual for HANYOUNG NUX models including: PR Series Photo Sensor, PR Series, Photo Sensor, Sensor

PR series

19 janv. 2023 — The contents of this manual may be changed without prior notification. • If the user use the product with methods other than specified by the.

Cảm biến quang Hanyoung PR Series Catalogue

PRWL30-15AC | Cảm biến tiệm cận từ Autonics | Amazen.com.vn

PR12-4DN -Cảm biến tiệm cận từ Autonics|12-24VDC|4mm|Amazen.com.vn


File Info : application/pdf, 2 Pages, 775.71KB

PDF preview unavailable. Download the PDF instead.

cam-bien-quang-hanyoung-pr-series-catalogue
Photo sensor
PR series
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG product. Please check whether the product is the exactly same as you ordered. Before using the product, please read this instruction manual carefully. Please keep this manual where you can view at any time

HANYOUNGNUX CO.,LTD

HEAD OFFICE

1381-3, Juan-Dong, Nam-Gu Incheon, Korea. TEL:(82-32)876-4697

FAX:(82-32)876-4696

http://www.hynux.net

INDONESIA FACTORY

PT. HANYOUNG ELECTRONIC INDONESIA Jl. cempaka blok F16, No.02 Delta Silicon II Cikarang Bekasi Indonesia TEL : 62-21-8911-8120~4 FAX : 62-21-8911-8126

MK0501KE120822

Safety information
Before using the product, please read the safety information thoroughly and use it properly. Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury

WARNING
· The contents of this manual may be changed without prior notification. · If the user use the product with methods other than specified by the
manufacturer, there may be bodily injuries or property damages. · If there is a possibility of an accident caused by errors or malfunctions of
this product, install external protection circuit to prevent the accident. · Avoid continuously switching the power source On and Off. · Use a dry cloth to wipe off the substance when cleaning the lens or
cases. Never use thinner or organic solvents. · Do not use this product at any place with much dust, vibration or impact. · Before inserting power source, make sure that the circuit wiring is
properly connected. · In the case of wiring loaded inductors such as d.c relay and others to
output, use diode, varistor and others to prevent surge. · To avoid malfunction caused by noise, do not put high voltage or
power line with sensor wire in a same conduit · Make its wiring be shorter as possible and wire extension shall be within 100 m. · Consider the fact that the sensing distance may be varied in
accordance with the size, color, surface condition, material, glossy, non-glossy or others of a sensing object. · Prevent strong disturbance light such as sunlight and others which directly enter into the directional angle of the sensor by putting a glare shield. · In the case of using multiple sensors (more than 2 sensors), there is a possibility of malfunction caused by mutual interference so, for Through-Beam type, sensors shall be installed in a divergent way or there shall be proper distance between them. · When using the switching power supply as the power source, earth the frame ground (F.G) terminal and be sure to connect the noiseeliminating condenser between 0 V and F.G.

Specification

Model Diffuse reflection

Retro reflection

Through-beam

Item
Sensing Distance

PRR300NC

PRR300NP

PR-M1NC PR-M1NP

PR-M2NC PR-M2NP

PR-T10NC

PR-T10NP

300 

0.1 - 1 m 0.1 - 2 m

10 m

Sensing Object

non-glossy and white transparent, translucent, opaque object above

paper above 200×200  opaque object above Ø25 

Ø10 

Hysteresis

Less than ±20 % of the sensing range

-

-

Response time

1.5  max

Power supply voltage
Current Consumption Light source

12 - 24 V d.c (±10 %)

Below 35 

Transmitter : 15  Receiver : 20 

Infrared ligteningLED (890 )

Adjusting Sensitivity

Built-in adjusting sensitivity volume (but, through-beam has only in the receiver)

Control Output

NPN voltage output, loaded voltage: below 30 V d.c, loaded current : below max 200 , residual voltage : below 1 V

Operation Mode

By control line, Light ON / Dark ON selecting mode switching
(but, through-beam has only in the receiver)

Operation Indicator

Operation Indicator (Red LED), Stability indicator (Green LED) (but, the transmitter (Red LED) of through-beam is power indicator)

Protection Circuit Ambient temperature

Built-in protection circuit from reversed power supply connection, output short-circuit overcurrent circuit protection
-20 ~ 60  (Surrounding storage temperature : -25 ~ 70 ) (with no icing or condensation)

Ambient Humidity

35 ~ 85 % R.H. (With no codensation)

Ambient Illumination

Sunlight : 11,000 Lux max, Incandescent lamp: 3,000 Lux max

Protective stucture

IP66 (IEC Standard)

Vibration resistance 10 - 50  double amplitude 1.5 , for 2 hours each in X·Y and Z directions

Shock resistance

500  3 times each in X·Y and Z directions

Dielectric strength

1,000 V a.c, 50/60  for 1 min

Insulation Resistance

20  min (500 V d.c, Between the code and case)

Connection method Code extendend type 2 m 4P (Transmitter of the throgh beam type : 3P)

Power Supply (SMPS)

C (0.01  - 0.1  / 500 V) - Noise Eliminating Condenser -

Photo sensor

Frame

 If you do not follow the contents described in the safety information then it is possible to be a cause of the product's malfunction so please follow them.

Product classification

Sensing method
Diffuse Reflection

Model PR-R300NC PR-R300NP

Sensing Power supply

distance

voltage

300 

Operation mode

Output

Individual

-

Reflector (50 × 50)

-

Acce-

ssories Common

Screw driver for adjusting sensitivity, nuts, washers (But, the nuts of Plastic Type are injection molding products. (except washers))

 · Sensing distance can be varied with size, surface condition, glossy, non-glossy or others of sensing object so that consider these facts.
· The Sensing Distance of PR-300NC, PR-R300NP is the distance of when using non-glossy white paper 200  × 200 .
· The Sensing Distance of PR-M1NC, PR-M1NP, PR-M2NC and PR-M2NP is the distance of when using MIRROR 50 × 50.
· PR-T10NC is one set of PR-TL10NC (transmitter) and PR-TR10NC (receiver). · PR-T10NP is one set of PR-TL10NP (transmitter) and PR-TR10NP (receiver).

Dimension
 Brass case (C)

[Unit : mm]

Retro Reflection

PR-M1NC PR-M1NP PR-M2NC PR-M2NP

0.1 - 1 m 0.1 - 2 m

12 - 24 V d.c

Light ON Dark ON Selectable by Control
Line

NPN voltage output

Volume of Adjusting Sensitivity Operation Indicator

ThroughBeam

PR-T10NC PR-T10NP

10 m

Lens

3

 Plastic case (P)
Lens
 Mirror (HY-M5)

Volume of Adjusting Sensitivity Operation Indicator

Control output circuit
 Receiver of diffuse reflection type, retro reflection type, through beam type

 Through-beam type

Operation Indicator

[Transimtter]

Sensing Object

[Receiver]

Volume of Adjusting Sensitivity
Operation Indicator

(Brown) 12 ~ 24 V DC
(Blue) 0 V (Black) Test Line
 Unused wires should be insulated.
Operation chart

(Brown) 12 ~ 24 V DC
(Blue) 0 V (White) Control line (Black) Output

Sensing Status

Light ON (Light On Operation)

TR Output and Light ON Indicator
(Red LED)

Dark ON (Dark On Operation)

TR Output and Light ON Indicator
(Red LED)

Stability Indicator (Green LED) (Except Through-Beam)

Stability Level Operation Level
Dark ON
ON Operation OFF Operation
ON Operation OFF Operation
ON Operation OFF Operation

Installation method
 Diffuse reflection type (PR-R300N)
1. Normally, it is used after setting sensitivity to the maximum but without a sensing object it may be affected by walls, supporters and others so please adjust it with considering this fact.
2. In the case of setting sensitivity to be higher level unreasonably there is a possibility of not working properly so please pay attention.
3. After placing a sensing object in the sensing place, gradually increase the sensitivity. Let's say Position , where the operation indicator lights.
4. After removing the sensing object in the sensing place, gradually decrease the sensitivity from the maximum. Let's say Position , where the operation indicator turns off. If the operation indicator turns off at the maximum of the sensitivity then the maximum point will be .
5. Let the middle point between  and  be the best suitable position.

Position

(Cautious) Wiring method of selecting Light ON/Dark ON mode Light ON : Connecting Control line to +V or OPEN Dark ON : Connecting Control line to 0 V
 Emitter(transmitter) of through beam type
(Cautious) 1. If you connect Test line to 0 V then POWER LED is OFF and if you do
not connect Test line then it will operate normally so that the product can be tested. 2. During the operation, Test line should be OFF. 3. If there are unused wires then they should be insulated.

[Picture 1]

[Adjusting Sensitivity Method]

 Retro reflection type (PR-M1N, PR-M2N)
1. After placing the sensor and mirror reflector to be face to face, adjust the position of the mirror reflector in the direction of top, bottom, left and right. After confirming the range of where the operation indicator turns off, place it in the middle.
2. After considering the sensing distance, sensing object and others, adjust the volume of adjusting sensitivity in the best suitable position.
3. In the case of installing multiple sensors (more than 2 sensors), place them with a distance of longer than 30 .
4. In the case of sensing a glossy surfaced object, install it with tilting 30° ~ 45°
from the moving direction of the sensing object to avoid its malfunction.

Connection
 Diffuse reflection type
Sensing Object

Volume of Adjusting Sensitivity Operation Indicator

 Retro reflection type

Mirror Reflector

Sensing Object

(Brown) 12 ~ 24 V DC (Blue) 0 V (White) Control line (Black) Output
Volume of Adjusting Sensitivity Operation Indicator
(Brown) 12 ~ 24 V DC (Blue) 0 V (White) Control line (Black) Output

[Picture 2]
 Through-beam type (PR-T10N)
1. After placing the transmitter and receiver to be face to face in the straight line and confirming the wires have been connected properly then turn the power on.
2. Pick either transmitter or receiver then fix it. As adjusting the other one in the direction of top, bottom, left and right, confirm the range of where the operation indicator turns off then place it in the middle.
3. If you finish the set-up, confirm whether it is properly operating or not after placing a sensing object in the optical axis of the sensing place.
4. Pay attention the case of not sensing a sensing object because the object is translucent or small object, below Ø8 mm.
5. Use it in the range of 95 % of the maximum operation distance. 6. After considering the sensing distance, sensing object and others,
adjust the volume of adjusting sensitivity in the best suitable position.
[Picture 3]
4



References