Description
The PM101 series comprises AC-DC switching power supplies designed in a compact 2 x 4 x 1.29 inch package. These units can deliver 100 watts of continuous power with 7.5 CFM forced air cooling or 80 watts with convection cooling. Constructed on a printed circuit board, they are suitable for medical applications, information technology, and industrial applications. Approvals to IEC60601-1 and IEC62368-1 safety standards streamline design-in processes and reduce end-equipment compliance costs.
Certifications: [CE Mark] [RoHS Compliant]
Features
- BF class insulation
- Operation altitude up to 5000 meters
- 2 x 4 inch footprint with 1.29 inch low profile
- Less than 175 μA leakage current
- Wide input range: 80-264 VAC
- Meets EN55011 / EN55032 and FCC Class B standards
- Short-circuit protection
- Compliant with RoHS requirements
- No load power consumption less than 0.15W
Safety Standard Approvals
[UL Certified] UL ES 60601-1, CSA C22.2 No. 60601-1 (File No. E178020)
[TÜV Certified] TÜV EN 60601-1
[UL Certified] UL 62368-1, CSA C22.2 No. 62368-1
[TÜV Certified] TÜV EN 62368-1
Input Specifications
- Input voltage: 80-264 VAC
- Power derating: Derates linearly from 100% at 90VAC to 90% at 85VAC and 80% at 80VAC.
- Input frequency: 47-63 Hz
- Input current: 2.0 A (rms) for 115 VAC, 1.2 A (rms) for 230 VAC
- Earth leakage current: 175 μA max. @ 264 VAC, 63 Hz
- Touch current: 100 μA max. @ 264 VAC, 63 Hz
Output Specifications
- Output voltage/current: See rating chart.
- Maximum output power: See rating chart.
- Ripple and noise: 1% peak to peak maximum.
- Over voltage protection: Set at 112-140% of its nominal output voltage; latches by recycle input to reset.
- Short circuit protection: Automatic recovery.
- Over temperature protection: Latching by recycle input to reset.
- Temperature coefficient: All outputs ±0.04% /°C maximum.
- Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 μs after a 25% step load change.
Environmental Specifications
- Operating temperature: -20°C to +70°C
- Storage temperature: -40°C to +85°C
- Relative humidity: 5% to 95% non-condensing
- Temperature derating: Derates from 100% at +50°C linearly to 50% at +70°C, applicable to convection and forced-air cooling conditions.
General Specifications
- Switching frequency: 65 KHz (typical)
- Efficiency: See rating chart.
- Hold-up time: 10 ms minimum at 100 W load and 115 VAC; 10 ms minimum at 80 W load and 100 VAC.
- Line regulation: ±0.5% maximum at full load.
- Inrush current: 80 A @ 115 VAC or 160 A @ 230 VAC, at 25°C cold start.
- Withstand voltage: 4000 VAC from input to output, 1500 VAC from input to ground, 1500 VAC from output to ground.
- MTBF: 150,000 hours at full load at 25°C ambient, calculated per MIL-HDBK-217F.
- EMC Performance:
- EN55011/ EN55032: Class B conducted, class B radiated
- EN61000-3-2: Harmonic distortion, class A
- EN61000-3-3: Line flicker
- EN60601-1-2, EN55024:
- EN61000-4-2: ESD, ±15 KV air and ±8 KV contact
- EN61000-4-3: Radiated immunity, 9-28 V/m
- EN61000-4-4: Fast transient/burst, ±2 KV
- EN61000-4-5: Surge, ±1 KV diff., ±2 KV com
- EN61000-4-6: Conducted immunity, 10 Vrms
- EN61000-4-8: Magnetic field immunity, 30 A/m
- EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms, 100% reduction for 10 ms
Output Voltage/Current Rating Chart
Model | V1 | Min. load | Max. Current at convection | Max. Current at 7.5 CFM | Tol. | Ripple & Noise(2) | Max. Power(1) | Efficiency (typical) 115/230 Vac |
---|---|---|---|---|---|---|---|---|
PM101-12A | 12 V | 0 A | 6.67 A | 8.34 A | ±2% | 120 mV | 80 W / 100 W | 87/90% |
PM101-13A | 15 V | 0 A | 5.34 A | 6.67 A | ±2% | 150 mV | 80 W / 100 W | 87/90% |
PM101-13-1A | 18 V | 0 A | 4.45 A | 5.56 A | ±2% | 180 mV | 80 W / 100 W | 87/90% |
PM101-14A | 24 V | 0 A | 3.34 A | 4.17 A | ±2% | 240 mV | 80 W / 100 W | 88/90% |
PM101-15A | 28 V | 0 A | 2.86 A | 3.58 A | ±2% | 280 mV | 80 W / 100 W | 88/90% |
PM101-16-1A | 32 V | 0 A | 2.50 A | 3.13 A | ±2% | 320 mV | 80 W / 100 W | 88/90% |
PM101-17A | 36 V | 0 A | 2.23A | 2.78 A | ±2% | 360 mV | 80 W / 100 W | 88/90% |
PM101-18A | 48 V | 0 A | 1.67A | 2.09A | ±2% | 480 mV | 80 W / 100 W | 88/90% |
Notes:
- The first value of max. power is at convection cooling. The second value is with 7.5 CFM forced air provided by user.
- Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum (or electrolytic) capacitor in parallel with a 0.1 μF ceramic capacitor across the output, except model PM101-12A which uses a 22 μF tantalum (or electrolytic) capacitor in parallel with a 0.1 μF ceramic capacitor across the output.
Mechanical Specifications
Dimensions: 2 x 4 x 1.29 inches [50.8 x 101.60 x 32.8 mm]. Tolerance: 0.02 [0.5] maximum.
Input Connector (CN1): Molex header 09-65-2038, mating with Molex housing 09-50-1031 or equivalent.
Output Connector (CN2): Molex header 09-65-2048, mating with Molex housing 09-50-1041 or equivalent.
Ground Tab: 0.25 [6.35] x 0.032 [0.8] fast-on connector.
Mounting: Four mounting holes, 0.157 [4.00] diameter.
Emissions Compliance: To ensure compliance with Level B emissions, connect the three "*" marked mounting holes with metallic standoffs to the chassis.
Weight: 155 grams (0.34 lbs.) approx.
Diagram Description: The diagram shows a rectangular power supply unit with connectors labeled CN1 and CN2. CN1 is a 3-pin connector on one side, and CN2 is a 4-pin connector on the opposite side. A ground tab is indicated. Mounting holes are shown around the perimeter. Dimensions are provided in inches and millimeters.
Output Power Derating Curves
Curve 1: Output Power vs. Input Voltage
This graph shows how output power is derated based on input voltage. The Y-axis represents Output Power (%) from 80% to 100%. The X-axis represents Input Voltage (V) from 80 to 264. The curve indicates full power (100%) is available from approximately 90V to 264V, with derating occurring below 90V, reaching 80% at 80V.
Curve 2: Output Power vs. Ambient Temperature
This graph illustrates output power derating based on ambient temperature. The Y-axis represents Output Power (%) from 50% to 100%. The X-axis represents Ambient Temperature (°C) from -20 to 70. The curve shows full power (100%) is available up to 50°C, and derates linearly to 50% power at 70°C.
Pin Chart
CN1 | CN2 | ||||||
---|---|---|---|---|---|---|---|
PIN NO. | 1 | 2 | 3 | 1 | 2 | 3 | 4 |
Polarity | Live | Void | Neutral | V1 | V1 | Common Return | Common Return |
Company Information
FSP Power Solution GmbH
Address: Jakobshöhe 16 / 41066 Mönchengladbach / Germany
Email: info@fsp-ps.de
Website: www.fsp-ps.de, www.fsp-group.com.ru
Phone: +49 (0) 2161 4952490
Fax: +49 (0) 2161 495249 21