Installation Guide for Altronix models including: T2PXK7F8V 8 Door Kit with Fused Outputs, T2PXK7F8V, 8 Door Kit with Fused Outputs, T2PXK7F8V 8 Door Kit
Altronix T2PXK7F8V 8-Door Access and Power Integration Kit, Trove2PX2 with eFlow104NBV, ACM8, VR6, PDS8 | 123 Security Products
File Info : application/pdf, 4 Pages, 741.99KB
DocumentDocumentAccess & Power Integration T2PXK7F8V 8 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TPX2 Altronix/Paxton backplane - One (1) eFlow104NBV - Power Supply/Charger - One (1) ACM8 - Fused Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module Installation Guide All components of this Trove kit are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information. All registered trademarks are property of their respective owners. More than just power.TM Rev. 070819 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix T2PXK7F8V Trove Paxton kit is pre-assembled and consists of Trove2PX2 enclosure/backplane with factory installed Altronix power supply/charger and sub-assemblies. T2PXK7F8 kit also accommodates up to eight (8) Paxton Net2 Plus modules for up to eight (8) doors in a single enclosure. Configuration Chart: 220VAC 60Hz Input Current (A) Power Supply Board Input Fuse Rating Power Supply Board Battery Fuse Rating Fail-Safe/Fail-Secure or Dry Form "C" Outputs Additional Fused Outputs ACM8 Board Input Fuse Rating ACM8 Board Output Fuse Rating PDS8 Board Input Fuse Rating PDS8 Board Output Fuse Rating Altronix Model Number Maximum Supply Current for Main and Aux. Outputs on Power Supply board and ACM8 Access Power Controller's outputs Nominal DC Output Voltage [DC] [Aux] Output Range (VDC) Output Range (VDC) T2PXK7F8V 2.7 6.3A/ 15A/ 250V 32V 24VDC @ 9.7A 20.17- 20.28- 26.4 26.4 8 8 10A/ 2.5A/ 10A/ 3A/ 250V 250V 32V 32V Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, Fig. 1 opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure, approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. Enclosure 4. Mount Paxton Net2 Plus modules to TPX2 backplane, refer to page 3. Edge of 5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NBV and corresponding Enclosure Sub-Assembly Installation Guides for the following models: ACM8, PDS8 and VR6 for further installation instructions. Tamper Switch (provided) Hardware: Nylon Spacer | 5/16" Pan Head Screw | Lock Nut To Access Control Panel or UL Listed Reporting Device - 2 - T2PXK7F8V T2PXK7F8V Installation Guide Configuration of Paxton Net2 Plus Modules: 1. Align the Paxton Net2 Plus modules on the backplane to match the modules' mounting holes with corresponding pems. 2. Fasten spacers (provided) onto metal pems (Fig. 2a, pg. 3). 3. Mount Paxton Net2 Plus modules to spacers utilizing pan head screws (provided) (Fig. 2a, pg. 3). Note: Paxton Net2 Plus modules have one (1) RJ45 jack and one (1) switch each. Please make sure that they are mounted correctly, as shown in Fig. 2 below. 4. Fasten TPX2 backplane to Trove2 enclosure utilizing hardware (provided). Fig. 2 L G N Altronix eFlow104NBV Paxton Net2 Plus Switch RJ45 Jack INTERFACE NO C NC +INP- T + RET- BAT + DC + MAIN 10A 250V FACP 1234 1234 ON ON Altronix ACM8 -+-+ Power Control Paxton Net2 Plus Switch RJ45 Jack OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM FACP TRG F8 F 7 TRIGGER INPUT 8 F 6 7 6 F 5 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 5 IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND F 4 4 3 Paxton Net2 Plus Switch F 3 2 1 F 2 F 1 Altronix - PDS8 DM1 + OFF IN1 IN2 IN1 Fuse 10 DM1 + 10 3 3 3 3 3 3 3 3 Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P Common (--- ) OUT1 DM2 + N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 Common (--- ) DM2 + Altronix VR6 is mounted under PDS8 RJ45 Jack Paxton Net2 Plus Switch RJ45 Jack T2PXK7F8V Installation Guide Paxton Net2 Plus Switch RJ45 Jack Paxton Net2 Plus Switch RJ45 Jack Paxton Net2 Plus Switch RJ45 Jack Paxton Net2 Plus Switch RJ45 Jack Fig. 2a Pan Head Screw Pem Spacer Paxton Net2 Plus Backplane - 3 - 2.00" (50.8mm) 1.25" (31.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 1.5" (38.1mm) Enclosure Dimensions (H x W x D approximate): 27.25" x 21.5" x 6.5" (692.15mm x 546.1mm x 165.1mm) 21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm) 0.5625" (14.3mm) 0.685" (17.4mm) 1.77" (45mm) Knockouts 1.125" (28.3mm) 2.415" (61.3mm) 0.885" (22.5mm) 6.25" (158.8mm) 2.00" (50.8mm) 19.80" (502.9mm) 2.00" (50.8mm) 6.75" (171.5mm) 8.25" (209.5mm) 27" (685.8mm) 8.00" (203.2mm) 1.00" (25.4mm) 0.85" (21.6mm) 1.25" (31.8mm) 2.00" (50.8mm) 2.00" (50.8mm) 5.25" (133.4mm) 7.00" (177.8mm) 5.25" (133.4mm) 1.25" (31.8mm) 2.00" (50.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIT2PXK7F8V J22U MEMBER - 4 - T2PXK7F8V T2PXK7F8V Installation Guide