Introduction

This document provides operating instructions for the FORA TD-2555G TNG Scale 550 Mobile, a digital weight scale designed for measuring Body Mass Index (BMI) and body weight.

Intended Use

The TD-2555G Weight Scale is intended for Body Mass Index / Body Weight measurement through the human body in a few seconds. The device is intended for use at home or in clinical settings.

Important Safety Precautions

  • Use this device ONLY for the intended use described in this manual.
  • Read all instructions before using.
  • Do NOT use if the device is not working properly or is damaged.
  • Consult a physician before beginning a weight loss or exercise program.
  • Consult a physician before using if pregnant.
  • Do NOT step on the edge or jump on the weighing platform.
  • Do NOT step on the platform if your body or feet are wet.
  • Do NOT use on slippery surfaces.
  • Keep away from devices generating strong electrical or electromagnetic fields (e.g., cell phones, microwaves).
  • Do NOT disassemble or modify the device.
  • Improper use may impair the device's protection.

KEEP THESE INSTRUCTIONS IN A SAFE PLACE.

Before You Begin

Body Mass Index (BMI)

BMI is a number used to evaluate body weight. The formulas are:

BMI = body weight (Kg) / (height(m))^2

BMI = body weight (lb) * 703 / (height(in))^2

Recommended Measurement Time

For accurate readings, measure at the same time of day and in the same environment. Avoid measurements:

  • Immediately after a bath or exercise.
  • After drinking alcohol or a large amount of water.
  • Less than 2 hours after a meal.

Measurements taken under these conditions may show significant differences due to changes in body water content.

Contents of the System

Your TD-2555G kit contains:

  • Weight Scale
  • Operating Instructions
  • Warranty Card
  • One Rechargeable Lithium-Ion Battery (HP14500)
  • One USB Type-C Cable

Scale Overview

Front View:

  • 1 LCD Screen
  • 2 Battery Indication Light
  • 3 Toe Position
  • 4 Heel Position
  • 5 Down Button [arrow-down]
  • 6 SET Button [SET]
  • 7 Up Button [arrow-up]
  • 8 Battery Cover / Compartment
  • 9 Supporting Stand
  • 10 USB Type-C Port [USB-C]

Screen Display Indicators:

  • [Age indicator] Age Indicator
  • [BMI indicator] BMI Indicator
  • [Gender indicator] Gender Indicator
  • [Profile number indicator] Personal Profile Number
  • [Height unit indicator] Height Unit
  • [Weight unit indicator] Weight Unit
  • [Measurement result indicator] Measurement Result
  • [Volume indicator] Volume Indicator / [4G signal indicator] 4G Signal Indicator
  • [Battery indicator] Battery Indicator

Setting the Scale

Before first use, input settings for accuracy. Start with the scale off. Press [SET] to turn on.

  1. Select Personal Profile: Press [arrow-left] or [arrow-right] to select a profile number (P1-P5). Press [SET].
  2. Enter Personal Profile Data:
    • Gender: Press [arrow-left] or [arrow-right] to select Male or Female. Press [SET].
    • Height Unit: Press [arrow-left] or [arrow-right] to select ft' in" or cm. Press [SET]. (Weight unit automatically sets to pounds for ft' in", kilograms for cm).
    • Height: Press [arrow-left] or [arrow-right] to set height between 3' 3.5" and 7' 2.5" (100 cm to 220 cm). Press [SET].
    • Age: Press [arrow-left] or [arrow-right] to set age between 6 and 99. Press [SET].
    • Voice Language: Press [arrow-left] or [arrow-right] to select English, Spanish, or French. Press [SET].
    • Voice Volume: Press [arrow-left] or [arrow-right] to set volume. Press [SET].
  3. Exit Setting Mode: Press [SET].

Settings are automatically saved. If you make a mistake, repeat from "Select Personal Profile".

Taking Measurements

Before Measuring

  • Place the scale on a hard, flat surface (avoid carpets/rugs).
  • Ensure feet are dry and positioned correctly. Remove shoes and socks.
  • Step onto the scale with feet parallel and weight evenly distributed.
  • Weigh yourself at the same time daily, before breakfast or dressing.

For first-time use or after moving the scale, press and release [SET] quickly to turn on. Wait for "0.0" to display before starting.

Measuring Weight and Body Mass Index (BMI)

  1. Press [SET] or tap the platform to turn on the scale. The last user's profile is displayed.
  2. Press [arrow-left] or [arrow-right] to select the desired profile number.
  3. Wait for "0.0" to appear on the display.
  4. Step onto the weighing platform. Stand still with weight evenly distributed.

The scale automatically turns on when stepped on in standby mode.

Understanding Your Displayed Result

Once a stable value is obtained, the reading will flash three times, then calculate your BMI.

Displayed Result Components:

  • 1 Personal Profile Number
  • 2 Gender (e.g., Male)
  • 3 Volume Indicator
  • 4 Your Weight
  • 5 Weight Unit (lb/kg)
  • 6 BMI Symbol
  • 7 Your BMI

After viewing results, step off the platform. The result is saved to memory and the scale enters 4G connection mode.

4G Signal Indicator

The indicator flashes during transmission. Three bars show signal quality:

  • 1 bar: weak
  • 3 bars: good

Solid bars mean 4G transmission is established. The scale turns off automatically after transmission or 3 minutes of inactivity.

Poor Signal: If signal quality is poor, move the scale to a location with better reception. Ensure it's not near devices that might interrupt the signal (microwaves, mobile devices).

Scale Memory

The scale stores up to 135 measurements for each of the 5 personal profiles. These results can be transmitted to a mobile device via 4G connection for review.

Maintenance

Battery

The scale uses one 3.7V Lithium-ion rechargeable battery.

Low Battery Signal: A message will appear when the battery is low, indicating it's time to charge.

Recharging the Battery

Use a USB adapter and a USB Type-C cable.

  1. Connect the USB adapter and USB Type-C cable to the scale.
  2. Plug the USB adapter into an electrical outlet. The battery indication light should turn red/orange.
  3. When the light turns green, the battery is fully charged. Remove the adapter and cable.

WARNING:

  • TD-2555G can ONLY use one 3.7V Lithium-ion rechargeable battery.
  • Installing incorrect battery types may cause explosions.
  • A USB adapter is NOT included. Ensure you have one before charging.

Cleaning

  • Wipe the exterior with a slightly damp cloth and water or a mild cleaning agent. Dry with a soft cloth.
  • Do NOT immerse the device in water.
  • Do NOT use chemical or organic solvents.
  • Clean spills immediately to prevent damage.

Scale Storage

  • Storage Conditions: -25°C to 70°C (-13°F to 158°F), 10% to 93% relative humidity.
  • Avoid dropping or heavy impact.
  • Avoid direct sunlight and high humidity.

System Troubleshooting

Error Messages

Message What it Means What to Do
[Overload symbol] The weighing subject exceeds the maximum capacity of the device. Remove the weighing subject from the platform to avoid damage.

If problems persist or other error messages appear, contact customer service. Do not attempt self-repair or disassembly.

Symbol Information

Symbol Referent Symbol Referent
[Manufacturer symbol] Manufacturer [Caution symbol] ⚠️ Caution
[Serial number symbol] Serial number

Specifications

General Information
Model No. TD-2555G
Power Source One 3.7V Lithium-ion rechargeable battery
Dimensions & Weight 340 (L) x 400 mm (W) x 32 mm (H), 3300g
Size of LCD 98 (L) x 92 (W) mm
LCD Backlit LCD
Range
  • Gender: Male / Female
  • Height: 3' 3.5" to 7' 2.5" / 100 to 220 cm
  • Age: 6 to 99
  • Weight: 8.8 to 550 lb / 4 to 250 kg
Operating Conditions 41°F to 104°F (5°C to 40°C), 15% to 85% R.H.
Storage Conditions -13°F to 158°F (-25°C to 70°C), 10% to 93% R.H.
Battery Life At least 180 measurements (3 minutes each) or 3 months on standby.
Power Supply Input DC +5V/2A via Type-C cable
Accuracy
  • 4.0 to 60.0 kg ±0.3kg
  • 60.1 to 250.0kg ±0.5%
User Profile 5 individuals
Weight Unit lb / kg
Transmission 4G
Operating Altitude Up to 2000m, for indoor use.
Degree of Pollution Pollution degree 2

Auto Switch-Off

  • If idle for 30 seconds during measuring mode, it will switch off automatically.
  • If idle for 3 minutes during 4G transmission mode, it will switch off automatically.

Compliance Information

This device has been tested and meets the electrical and safety requirements of: IEC/EN 61010-1, IEC/EN 61326-1, EN 301 489-17.

Federal Communications Commission (FCC) Statement

§ 15.21: Users are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

§ 15.105(b): This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation of the device.

FCC RF Radiation Exposure Statement:

  • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
  • For portable operation, this device has been tested and meets FCC RF exposure guidelines. When used with an accessory that contains metal, it may not ensure compliance with FCC RF exposure guidelines.

Manufacturer Information

Taidoc Technology Corporation

B1-7F, No. 127, Wugong 2nd Rd., Wugu Dist., 24888 New Taipei City, Taiwan

Website: www.taidoc.com

Models: 2555GLTE, TM72555GLTE, TD-2555G Weight Scale, TD-2555G, Weight Scale, Scale

File Info : application/pdf, 3 Pages, 319.13KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5907763

References

Adobe PDF library 16.00 Adobe Illustrator 25.4 (Windows)

Related Documents

Preview FORA W310/W320 Series Weight Scale Owner's Manual
Comprehensive owner's manual for FORA W310 and W320 series weight scales, covering setup, usage, maintenance, and safety precautions for accurate body weight and BMI measurements.
Preview FORA PO200 Fingertip Pulse Oximeter Operation Manual
User manual for the FORA PO200 Fingertip Pulse Oximeter (Model TD-8255B), detailing operation, safety, troubleshooting, and specifications for monitoring blood oxygen saturation and pulse rate.
Preview FORA ADVANCED pro GD40 Owner's Manual
Owner's manual for the FORA ADVANCED pro GD40 Blood Glucose plus ß-Ketone Monitoring System. Learn about its features, setup, testing procedures, and safety information.
Preview FORA COVID-19 Antigen Rapid Test: Instructions for Use and Performance Data
Comprehensive guide to the FORA COVID-19 Antigen Rapid Test, covering intended use, assay procedure, interpretation of results, quality control, and analytical performance data for SARS-CoV-2 detection.
Preview FORA P50 Blood Pressure Monitoring System Owner's Manual
Comprehensive owner's manual for the FORA P50 Blood Pressure Monitoring System. Provides clear instructions on setup, accurate measurement techniques, result interpretation, maintenance, and troubleshooting for effective cardiovascular health management.
Preview FORA P20 Blood Pressure Monitoring System Owner's Manual
User manual for the FORA P20 Blood Pressure Monitoring System, providing instructions on setup, measurement, maintenance, and troubleshooting for accurate home blood pressure monitoring.
Preview FORA MT86 Digital Thermometer: User Manual and Instructions
Comprehensive guide for the FORA MT86 digital thermometer, covering usage, safety, specifications, and warranty. Learn how to accurately measure body temperature with this medical device.
Preview FORA 6 Connect Multi-functional Monitoring System Owner's Manual
This manual provides comprehensive instructions for the FORA 6 Connect Multi-functional Monitoring System, covering setup, testing procedures for blood glucose, ketones, total cholesterol, and uric acid, as well as maintenance and troubleshooting.