MyHOME Server
The MyHOME Server is a device designed to interact with the MyHOME_Up system via the MyHOME_Up smartphone and tablet app (available on Android and iOS stores). This device allows for the commissioning of the MyHOME system, specifically for Lighting, Automation, and Thermoregulation functions through the MyHOME_Up application. The energy management system can be configured using the PC software MYHOME_Suite.
The MyHOME Server enables control of the MyHOME_Up system and third-party devices through the MyHOME_Up application. It also allows installers and end-users to add or customize scenarios and schedules.
Compatibility Notes:
- MyHOME Server is compatible only with the MyHOME_Up application and MyHOME_Suite software.
- The new Living Now civil series is compatible with firmware versions later than 2.1 and app versions later than 2.2.
- For correct operation, connections must be made on the private rising BUS (level 3) of the automation system (refer to the MyHOME Automation Guide).
- The MyHOMEServer1 automatically detects connected devices upon first power-up. Each channel of every actuator is assigned an address, even if not used to control a load. The maximum number of occupied channels is 175. Exceeding this limit will prompt the MyHOME_Up app to suggest removing excess devices. MyHOME Server cannot be installed on systems with logical expansion.
- MyHOME Server manages Lighting, Automation, Thermoregulation, Energy Management, the new Anti-theft system, and the Nuvo audio system.
- It can interact with devices such as Philips Hue and Lifx lamps.
Technical Data
Front View
1. RJ45 for Ethernet LAN 10/100 Mbit
2. Under the flap:
- USB Port
- RESET Button (to switch to DHCP Dynamic IP, press for 10 s)
- RS232 Serial Connection
3. User Interface:
- Speed: Connection speed (on = 100 Mbit/s, off = 10 Mbit/s)
- Link: On indicates Ethernet network presence
- System: Powering on the device, it turns off and on again, indicating the MyHOME Server is operational.
4. 2-wire BUS for connection to the MyHOME system
5. Supplementary power supply (optional) (27 Vdc)
Technical Specifications
- SCS BUS Power Supply: 18-27 Vdc
- Supplementary Power Supply (optional): 18 – 27 Vdc
- SCS BUS Current Draw (without supplementary power): 130 mA max
- SCS BUS Current Draw (with supplementary power): 3 mA max
- Current Draw from supplementary power: 160 mA max
- Operating Temperature: 5-35°C
Dimensional Data
- Space required: 6 DIN modules.
Associated Lighting and Automation Devices
Description | Legrand Code | A partire da lotto produzione | BTicino Code | Canali configurati automaticamente da MyHOMEServer1 | A partire da lotto produzione | Canali configurati automaticamente da MyHOMEServer1 |
Scenario Command | LG-573902 | 08W51 | BT-L4680 | 09W08 | ||
LG-573903 | 08W51 | BT-N4680 | 09W08 | |||
LG-574503 | tutti | BT-NT4680 | 09W08 | |||
LG-574504 | tutti | BT-HC4680 | 09W08 | |||
LG-067217 | tutti | BT-HD4680 | 09W08 | |||
LG-067218 | tutti | BT-HS4680 | 09W08 | |||
LG-078478 | tutti | |||||
LG-079178 | tutti | |||||
SCS/SCS Interface | LG-003562 | 12W20 | BT-F422 | 12W20 | ||
Touch Command Multifunction | LG-067243 | 13W05 | ||||
LG-067244 | 13W05 | |||||
LG-067245 | 13W05 | |||||
8-Button BUS Command | LG-067592 | tutti | BT-LN4652 | tutti | ||
BT-H4652 | tutti | |||||
2m Base Command | LG-067552 | tutti | AR-64360 | 09W40 | ||
BT-H4652/2 | 09W40 | |||||
BT-L4652/2 | 09W40 | |||||
BT-AM5832/22 | 09W40 | |||||
3m Base Command | LG-067554 | tutti | BT-L4652/3 | 09W40 | ||
BT-H4652/3 | 09W40 | |||||
BT-AM5832/3 | 09W40 | |||||
Shutter Actuator BUS | LG-067557 | tutti | 1 | BT-LN4661M2 | tutti | 1 |
BT-H4661M2 | tutti | 1 | ||||
BT-AM5861M2 | tutti | 1 | ||||
Shutter Command BUS | LG-067558 | tutti | BT-LN4660M2 | tutti | ||
BT-H4660M2 | tutti | |||||
BT-AM5860M2 | tutti | |||||
Special Command | LG-067553 | tutti | AR-64362 | tutti | ||
BT-L4651M2 | 08W41 | |||||
BT-H4651M2 | 08W41 | |||||
BT-AM5831M2 | 08W41 | |||||
1-Relay DIN Actuator 100/240V | LG-003847 | tutti | 1 | BT-F411U1 | tutti | 1 |
2-Relay DIN Actuator 100/240V | LG-003848 | tutti | 2 | BT-F411U2 | tutti | 2 |
1-Relay DIN Actuator 100/240V | LG-003841 | 10W17 | 1 | BT-F411/1N | 09W13 | 1 |
2-Relay DIN Actuator 16A | LG-003842 | 10W18** | 2 | BT-F411/2 | 09W04** | 2 |
2-Relay DIN Actuator 100/240V | LG-002601 | tutti | 2 | BT-BMSW1002 | tutti | 2 |
4-Relay DIN Actuator 100/240V | LG-002602 | tutti | 4 | BT-BMSW1003 | tutti | 4 |
4-Relay DIN Actuator 6A | LG-003844 | 10W22* | 4 | BT-F411/4 | 09W04* | 4 |
4-Relay DIN Actuator 100/240V | LG-002604 | tutti | 8 | BT-BMSW1005 | tutti | 8 |
4-Output Actuator for 0-10V ballast | LG-002612 | tutti | 4 | BT-BMDI1002 | tutti | 4 |
0-10V Ballast Actuator | LG-003656 | 10W05 | 1 | BT-F413N | 09W14 | 1 |
Basic Contact Interface | LG-573996 | 10W04 | BT-3477 | 10W04 | ||
DIN Contact Interface | LG-003553 | 10W13 | BT-F428 | 09W50 |
Associated Thermoregulation Devices
Description | Legrand Code | A partire da lotto produzione | BTicino Code | A partire da lotto produzione |
Thermostat with Display | LG-067459 | tutti | BT-LN4691 | tutti |
LG-064170 | tutti | BT-H4691 | tutti | |
LG-752131 | tutti | |||
LG-752731 | tutti | |||
Thermoregulation Probe | BT-KM4691 | tutti | ||
BT-KG4691 | tutti | |||
BT-KW4691 | tutti | |||
Non-regulation Probe | LG-067458 | 13W36 | BT-L4693 | 13W36 |
LG-573924 | 13W36 | BT-N4693 | 13W36 | |
LG-573925 | 13W36 | BT-NT4693 | 13W36 | |
BT-HC4693 | 13W36 | |||
BT-HS4693 | 13W36 | |||
BT-HD4693 | 13W36 | |||
2-independent relay DIN Actuator | LG-003579 | 13W06 | BT-F430/2 | 13W06 |
4-independent relay DIN Actuator | LG-003580 | 13W06 | BT-F430/4 | 13W06 |
8-independent relay DIN Actuator | LG-003517 | tutti | BT-F430R8 | tutti |
2 x 0-10 V outputs DIN Actuator | LG-003518 | tutti | BT-F430V10 | tutti |
3-independent relay and 2 x 0-10 V outputs DIN Actuator | LG-003519 | tutti | BT-F430R3V10 | tutti |
NOTE: For systems with a 99-zone thermoregulation central unit, device configuration must be done via physical or virtual configuration. In this case, all batches are compatible.