Simple Door Security Alarm

KS-SF19 Update User Manual

Document Version: 4202000305 V1.2

Product Overview

This document provides instructions for the KS-SF19 Simple Door Security Alarm, a magnetic door intruder detector.

Host Unit Diagram

The host unit includes indicators for General Alarm, Constant Alarm, Closing-door Alert, Doorbell mode, and OFF/disarm. It also shows the battery cover.

1. Product Parameters

  • Host Power: 2 AAA size alkaline batteries.
  • Battery Life: Standby time over 2 years (based on 5 ON/OFF cycles per day).
  • Alarm Volume: 108dB.
  • Operating Temperature: -10°C to +60°C.
  • Operating Humidity: Relative Humidity <80%.
  • Storage Temperature: -20°C to +70°C.

2. Functions

2.1 Battery Installation

  1. Open the battery cover and insert 2 AAA alkaline batteries.
  2. A successful installation is indicated by a "Be...Be" sound.
  3. Alkaline batteries are recommended for optimal performance. Using other battery types may reduce usage time or alarm sound volume.

2.2 Magnetic Sensor Installation

  1. Clean the installation area with a damp cloth and ensure it is dry.
  2. Attach the magnetic sensor using the provided double-sided adhesive tape.
  3. Position the magnetic stick next to the magnetic sensor, within 1cm, ensuring the alignment arrows on both components face each other.

Installation Figure: The magnetic stick should be aligned with the sensor, with a distance of less than 10mm between them. Arrows on both parts should point towards each other.

Turning the Host On/Off

  • To Turn On: Press any function key once. The host will turn on and enter the selected function mode.
  • To Turn Off: Long press the [OFF/disarm] key for 2 seconds. All functions will be cancelled, and the host will turn off with a long "Di" sound.

3. Usages

3.1 General Alarm Mode

3.2 Constant Alarm Mode

3.3 Closing-door Reminder Mode

3.4 Doorbell Mode

3.5 OFF/Disarm

4. Battery Low Power Indication

When the host's power is low, the LED will flash once every second and produce a "DiDi" sound every 30 minutes. Please replace the battery.

Cautions

  1. Keep the alarm installed indoors, away from severe pollution or high humidity.
  2. Ensure the magnetic stick is on the right side of the magnetic sensor, with the arrow indications opposite each other.
  3. If the magnetic sensor is on the door, the magnetic stick should be on the door frame on the right side of the sensor, or vice versa. Test by opening the door to ensure separation triggers the alarm.
  4. The magnetic sensor and stick should be less than 10mm apart when the door/window is closed.
Models: KS-SF19 Simple Door Security Alarm, KS-SF19, Simple Door Security Alarm, Door Security Alarm, Security Alarm, Alarm

PDF preview unavailable. Download the PDF instead.

magnetic-door-(fridge)-detector-alarm WIA-Brother DCP-L2530DW LAN Adobe Acrobat Pro DC 15

Related Documents

Preview KS 2000 i S Generator Startup and Shutdown Guide
A concise guide for safely starting and shutting down the KS 2000 i S generator, detailing choke and vent operations for optimal performance.
Preview KS Height Adjustable Seatpost User Manual
Comprehensive user manual for KS Height Adjustable Seatposts, covering installation, operation, maintenance, and safety for models LEV-Ci, LEV Integra, LEV-Si, e30-i, Crux-i, and eTen-i. Includes warranty information and resources.
Preview KS Height Adjustable Seatpost User Manual and Installation Guide
Comprehensive user manual for KS Height Adjustable Seatposts, covering installation, operation, safety, and maintenance for models LEV-Ci, LEV Integra, LEV-Si, e30-i, Crux-i, and eTen-i. Includes detailed instructions and textual descriptions of diagrams.