User Guide for Mikro models including: RX 232 Earth Fault Relay, RX 232, Earth Fault Relay, Fault Relay, Relay
RX232 Earth-fault Relay User Guide (a) (b) (c) (d) (e) RX 232 EARTH FAULT RELAY - Io Earth-Fault Setting - Io> Protection - Io> Delay Type - tIo>(Seconds) /ktIo> - Io>> Protection - tIo>>(Seconds) Functions Setting Date and Time Setting (f ) (g) ( h) ( i ) ( j ) ( a ) Function indication ( b ) Data indication ( c ) Auxiliary power supply indicator ( d ) Low-set start/trip status indicator ( e ) High-set start/trip status indicator ( f ) Up button ( g ) Down button ( h ) NFC detection area ( i ) Test button ( j ) Reset/Mode button Typical Application Diagram DANGER Features - Two stages setting for earth fault - IDMT and definite time - Circuit breaker failure protection - Selectable fundamental or true RMS - Selectable 50 or 60 Hz frequency - Programmable output contacts - 30 Fault, 30 pickup and 120 event records date & time stamp - Build in NFC for read and set parameters through mobile app - Complies with IEC 60255 standard - ANSI code: 50N, 51N, 50BF Case Dimensions 96mm FRONT 90mm 70mm SIDE 91±0.5mm PANEL CUTOUT NFC Communication Relay provides NFC communication convenient for user to read parameter values or to change setting through Android phone with NFC feature and Android OS version 10 and above. The Mikro RX app can be downloaded in the mobile with one of following Methods: {Make sure phone NFC function is turned on} - Scan the QR code or align the mobile phone NFC antenna on the NFC logo at relay front panel. This will take you directly to the app on Google play 96mm 91±0.5mm IDMT Curve Normal Inverse 3/10 Normal Inverse 1.3/10 Very Inverse Long-time Inverse Extremely Inverse Technical Data Ratings Rate Current In.................................... 5A Frequency............................................. 50 or 60Hz Burden.................................................... <0.3VA at In Thermal Withstand............................ 4 x In Continuous Auxiliary Supply Supply Voltage.................................... 198 ~ 265VAC Supply Frequency.............................. 50 or 60Hz VA Rating............................................... 3VA max Accuracy Protection Thresholds...................... ±3% or ±20mA Time Delay............................................ ±3% or ±40ms Setting Ranges (i)Earth-fault Setting Low-set Setting Io>............................. 0.1A - 10.0A(2% - 200%) Low-set time Multiplier ktIo>.......... 0.01 - 1.00 Low-set Definite Time tIo>............... 0.03 - 100s Delay Type............................................ DT, NI3/10, NI1.3/10, VI, LI, EI High-set Setting Io>>......................... OFF/0.1 - 50A (2% - 1000%) High-set Definite Time tIo>>........... 0.03 - 100s Output Contacts Rated Voltage......................................... 250VAC Continuous Carry.................................. 5A(Cos = 1.0) Expected Electrical Life....................... 105 operations Expected Mechanical Life................... 5 x 106 operations Enviromental Conditions Temperature............................................ -10°C to 55°C Humidity................................................... 5% to 95% non-condensing Mechanical Mounting.................................................. Panel mounting Dimension (mm) ................................... 96(w) x 96(h) x 90(d) Enclosure Protection............................. IP54 at the panel IP20 at the body Approximate Weight............................. 0.65kg NFC Communication Operation System.................................. Android OS Software Version ................................... Version 10 and above System Operation Fucntion Data Measurement earth-fault measurement Press "Mode" earth-fault previous tripped current Parameter Settings Menu Press and hold "Mode" for 1s enter menu Press "Mode" Earth-Fault Setting Io> Protection (A) [DEF=0.5] Io> Delay type [DEF=NI] tIo> (Seconds)/ktIo> [DEF=0.1] Io>> Protection (A) [DEF=10.0] tIo>> (Seconds) [DEF=0.05] Push Button Operation Trip Test Press and hold "TEST" button for 3.5 seconds Trip Reset Press "RESET" button Scroll Display Press "MODE" button Enter Menu Mode Set/Save Setting Adjust Setting Clear Thermal % Display Off Mode Press and hold "MODE" button for 1second Press "UP" and "DOWN" button simultaneously Press "UP" or "DOWN" button Press and hold "UP" and "DOWN" button simultaneously for 1.5 seconds on Thermal page Press "RESET" button for 10 seconds to toggle display off mode. The display will switch off after 6 minutes if no key is pressed. Date and Time Setting Year Month Day Hour Minute Second [DEF=Default setting] LED Indicator LED AUX I> I>> Status 0 0 0 No Auxiliary power suppply 1 0 0 Normal condition, no tripping 1 1 0 Low-set pickup 1 0 1 High-set pickup 1 B 0 Low-set tripped 1 X B High-set tripped 1 = ON 0 = OFF B = Blinking X = don't care Functions Setting Frequency [50Hz/60Hz] [DEF=50Hz] Measurement display [Fn= Fundametal, RnS= RMS] [DEF=Fn] Output R1 reset type [n-A= Manual, AUt= Auto] [DEF=n-A] Output R2 reset type [n-A= Manual, AUt= Auto] [DEF=AUt] Output R2 function [DEF=IrF] [Str= Start, trp= Trip, cbF=Circuit breaker failure, IrF= Internal relay failure] *IRF contact function Relay healthy : R2 energized Relay fault : R2 denergized Output R1 link element [Refer figure 1] [DEF=3h] Output R2 link element [Refer figure 1] [DEF=3h] CBFP Delay [0.05s - 10.0s] [DEF=0.1] NFC remote set [Yes/No] [DEF=No] Digit1 Digit1 HEX Io>> Io> 0 00 1 01 2 10 3 11 Figure 1: Link element in Hexadecimal value 0= Off, 1= On User's setting User's setting hexadecimal value Digit1 * Not applicable when output R2 function set as cbF or IrFAdobe Illustrator CC 2015 (Windows) 3-Heights(TM) PDF Security Shell 4.8.25.2 (http://www -tools.com)