User Guide for Strand models including: 63025 RS232 Serial Interface, 63025, RS232 Serial Interface, Interface
VISION.NET RS232 & USB MODULE | Vari-Lite
13 ago 2022 — The Vision.Net Network consists of a single CAT5e cable connecting all modules in a daisy chain manner. All units connect to the network using a 9-pin ...
File Info : application/pdf, 3 Pages, 129.08KB
DocumentDocumentQUICK START GUIDE VISION.NET RS232 SERIAL INTERFACE This document provides basic setup instructions and safety warnings for the following product(s): 63025 Vision.Net RS232 Serial Interface I N S TA L L AT I O N The Vision.Net Network consists of a single CAT5e cable connecting all modules in a daisy chain manner. All units connect to the network using a 9-pin plug-in connector (included). To install the RS232 serial port interface: Step 1. Unpack unit and inspect for any signs of shipping damage. Ensure that two mounting screws are included. Step 2. Connect Vision.Net Network Cable to 9-pin connector at back of RS232 Interface. PIN SIGNAL NO. WIRE COLOR 1 DATA + White / Orange 2 DATA Orange 3 No Connection N/A 4 +NET V White / Green 5 Ground Green 6 + NET V White / Blue 7 Ground Blue 8 + NET V White / Brown 9 Ground Brown Vision.Net Cable Vision.Net RS232 Step 3. Step 4. Insert RS232 Interface into standard deep rough-in box (not included). Secure with two supplied mounting screws. Snap faceplate into place. NOTE: A standard IBM-compatible computer can be connected to the Vision.Net Network using the RS232 Interface. The port accepts a standard one-to-one 9-pin serial cable up to 25 feet (7.5 meters) in length. Faceplate O P E R AT I O N The RS232 Serial Interface Port operates in one of two modes: Vision.net (binary) or Show Control (ASCII). VISION.NET MODE SHOW CONTROL MODE 8-Bit 1-Stop Bit 19200 Baud Protocol: Binary 8 Bit 1 Stop Bit 9600 Baud Protocol: ASCII The unit will sense the incoming protocol and automatically switch to the proper mode. Note: It may take several messages from either the third-party system or the Vision.net Designer PC before the RS232 Interface switches modes. 63025 1 W W W. S T R A N D L I G H T I N G . C O M ©2019 Signify Holding. All rights reserved. VISION.NET RS232 SERIAL INTERFACE QUICK START GUIDE C O M M U N I C AT I O N S These are the communication protocols available for use with the RS232 Serial Port Interface. · Vision.Net Protocol (binary) · ASCII TABLE 1. ASCII CODES DESIGNER COMMANDS ASCII RS232 NOTES Print Command Help Page Start Preset Toggle Down Toggle Up HH<cr> SP rrr pp tt<cr> TD rrr ccc<cr> TU rrr ccc<cr> rrr = Room (1 - 255), pp = Preset (1-32, 0 = Off), tt Rate Index (see "Rate Index" on page 47) rrr = Room (1 - 255), ccc = Channel (1 - 127) Learn Preset LP rrr pp<cr> rrr = Room (1 - 255), pp = Preset (1-32, 0 = Off) Slider Level SL rrr ccc lll<cr> rrr = Room (1 - 255), ccc = Channel (1 - 127), lll = Level (0 - 255) Learn Submaster Manual Expander Group Start Raise Start Lower Stop Raise/Lower Record Blind Lock Button LS rrr ss<cr> MN rrr ggg lll ... lll<cr> EG rrr ee ff lll ... lll<cr> RA rrr qqq<cr> LW rrr qqq<cr> ST rrr qqq<cr> RB rrr pp ggg lll ... lll<cr> LB idd n<cr> rrr = Room (1 - 255), ss = Submaster Index (1 - 16) rrr = Room (1 - 255), ggg = Grand Master Level (0 - 255)x, lll = Level (0 - 255) rrr = Room (1 - 255), ee = Expander Group (0 - 15), ff = Index of First Channel, lll = Level (0 - 255) rrr = Room (1 - 255), qqq = Coded Channel (0: Reserved, 1- 127: Channels 1 to 127, 128: All Channels in Room, 129 - 255: Channel in Preset 1 - 126, 255: Current Preset Channels) Note: Sending a second <cr> after a RA or LW command will rrr = Room (1 - 255), pp = Preset (1-32, 0 = Off), ggg = Grand Master Level (0 - 255), lll = Level (0 - 255) Unlock Button Smart On UB idd n<cr> SN idd n<cr> idd = __________, n = Button/LED (1-255) Smart Off SF idd n<cr> Define Room Link Submaster Level DR x fff rrr ... rrr<cr> SB rrr ss lll<cr> x = Links (0: Clear All Links / 1: Do Not Clear), fff = First Room (1-255), rrr = Room (1 - 255) rrr = Room (1 - 255), ss = Submaster Index (1-16), lll = Level (0 - 255) Take Control (sub) Set Channel Set Mode Send Mimic Console Button Console LED TC rrr ggg lll ... lll<cr> SC rrr ccc lll tt<cr> SM mm<cr> MC idd n a<cr> CB idd n a<cr> CL idd n a<cr> rrr = Room (1 - 255), ggg = Grand Master Level (0 - 255), lll = Level (0 - 255) rrr = Room (1 - 255), ccc = Channel (1 - 127), lll = Level (0 - 255), tt = Rate Index (see "Rate Index" on page 47) mm = Mode (0 = All Modes) idd =__________, n = Button/LED (1-255), a = Action (0/1= Off/On or Button Up/Down for Send Mimic Command) (0/1= Button Down/Up for Console Button Command) (0/1= LED Off/ On for Console LED Command) TABLE 2. RATE INDEX VALUE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 MEANING Instant 1 second 2 seconds 3 seconds 5 seconds 7 seconds 10 seconds 15 seconds 30 seconds 1 minute 5 minutes 15 minutes 30 minutes 60 minute 63025 2 W W W. S T R A N D L I G H T I N G . C O M ©2019 Signify Holding. All rights reserved. IMPORTANT INFORMATION WARNINGS AND NOTICES When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. · For indoor, dry locations use only. Do not use outdoors. · Do not mount near gas or electric heaters. 2000851 · Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. · The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. · Not for residential use. Do not use this equipment for other than intended use. · Refer service to qualified personnel. SAVE THESE INSTRUCTIONS. WARNING: You must have access to a main circuit breaker or other power disconnect device before installing any wiring. Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation. Installing the device with power on may expose you to dangerous voltages and damage the device. A qualified electrician must perform this installation. WARNING: Refer to National Electrical Code® and local codes for cable specifications. Failure to use proper cable can result in damage to equipment or danger to personnel. WARNING: This equipment is intended for installation in accordance with the National Electric Code® and local regulations. It is also intended for installation in indoor applications only. Before any electrical work is performed, disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control. It is recommended that a qualified electrician perform this installation. CUSTOMER SERVICE If you have any questions regarding this product, please contact Customer Service at +1-214-647-7880 or via e-mail at entertainment.service@signify. LIMITED 2-YEAR WARRANTY Strand offers a two-year limited warranty on its control products against defects in materials or workmanship from the date of delivery. A copy of Strand two-year limited warranty containing specific terms and conditions can be obtained from the Strand website at www.strandlighting.com or by contacting your local Strand o ce. STRAND OFFICES AMERICAS 10911 Petal Street Dallas, TX 75235 Tel: +1 214-647-7880 Fax: +1 214-647-8039 ASIA Room 1201, Freetown Tower D E 3rd Ring Rd S, 58 Chaoyang Qu Beijing Shi, China Tel: +8610-58674776 Fax: +8610-58674775 B-1-27, Dataran Cascades, No. 13A Jalan PJU 5/1 Kota Damansara PJU 5 47810 Petaling Jaya Selangor, Malaysia Tel: +60 3-7611 7302 EUROPE Rondweg Zuid 85 Winterswijk 7102 JD Netherlands Tel: +31 543-542516 Fax: +31 543-542513 24 Sovereign Park Coronation Road Park Royal, London NW10 7QP United Kingdom Tel: +44 020 8965 3209 © 2019 Signify Holding. All rights reserved. All trademarks are owned by Signify Holding or their respective owners. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. Data subject to change. 3