User Manual for IGS models including: SPC-100 Industry Gas Spring, SPC-100, Industry Gas Spring, Gas Spring
SEMES SPC-100 2AN5B-SPC-100 2AN5BSPC100 spc 100
File Info : application/pdf, 10 Pages, 558.66KB
DocumentDocumentSPC-100 Rev.01 USER MANUAL Product Overview 1-1. Characteristic Real-time particle monitoring and control Precision measurement and long-term stability 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 6-CH particle monitoring 268 * 128 mono graphic LCD applied Simultaneous display of particle, temperature and humidity measurements RS485 communication (Modbus RTU) WI-Fi communication Station Mode : TCP/IP, Wi-Fi(2.4GHz) communication support 1-2. Applications Semiconductor cleanroom particle, temperature, humidity measurements Particle, temperature and humidity measurement in pharmaceutical and hospital cleanroom Various semiconductor equipment IAQ (Indoor Air Quality) monitoring and control device for home and industrial Home and industrial air conditioner 1-3. Specifications Model Operating Voltage Current consumption Operating principle Measurement particle size range Measurement range Counting efficiency Temperature measuring range Humidity measuring range Wi-Fi output Protocol Digital Output RF frequency bands Maximum RF output power Operating Temperature Storage Temperature Dimension ( W*H*D) Weight SPC-100 12Vdc ±10% (DC Adapter plug: inner diameter 2.1, outer diameter 5.5PIE) Max. 350mA @ 12Vdc Laser scattering >0.3, >0.5, >1.0, >2.5, >5.0, >10 0 ~ 10,000,000 pcs/L (1pcs/L = 28.3pcs/cf) 50%@0.3m , 100%@>0.5m ( 0°C ~ 40°C, 50 ±10%RH ) -40 ~ +125 / ±1 0 ~ 100% / ±5.0% Station Mode (TCP/IP Communication) RS485 Modbus WLAN: 2412-2472 MHz / BLE: 2402-2480 MHz WLAN: 19.8 dBm / BLE: 9.8 dBm 10... +60 0... +70 110*185*44.3 (Wi-Fi Without Antenna) 387g Product Function and How To Use Operating configuration KEY M KEY Name UP KEY DOWN KEY MENU KEY ENTER KEY Description Move up and increase value Move down and decrease value Enter configuration mode Enter Configuration Mode Configuration Mode Sensor display Settings Equipment Settings Sensor Alarm Settings Wi-Fi Settings Sensor Display Settings Particle size range setting displayed on the initial screen Equipment Settings Equipment Default Settings. Sensor Alarm Settings Set an alarm for each Particle Size Range. Click the MENU button to enter configuration mode. Wi-Fi Settings Settings required for Wi-Fi communication. Product Function and How To Use Sensor Display Settings Configuration Mode Sensor Display Settings Equipment Settings Sensor Alarm Settings Wi-Fi Settings Sensor Display Settings Left Upper 0.3 um Right Upper 0.5 um Left Lower 1.0 um Right Lower 2.5 um Click the ENTER button to enter Sensor Dispalys Settings. Equipment Settings Configuration Mode Sensor Display Settings Equipment Settings Sensor Alarm Settings Wi-Fi Settings Particle size range setting displayed on the initial screen Equipment Settings Language Settings English Equipment ID 1 Baud Rate 115200bps temperature unit Click the ENTER button to enter Equipment Settings. Equipment Default Settings. Product Function and How To Use Sensor Alarm Settings Configuration Mode Sensor Display Settings Equipment Settings Sensor Alarm Settings Wi-Fi Settings Sensor Alarm Settings 0.3 um Upper Limit 0 0.3 um Lower Limit 0 0.5 um Upper Limit 0 0.5 um Lower Limi 0 Click the ENTER button to enter Sensor Alarm Settings. Wi-Fi Settings Configuration Mode Sensor Display Settings Equipment Settings Sensor Alarm Settings Wi-Fi Settings Set an alarm for each Particle Size Range. Wi-Fi Settings AP IP (1) 192 AP IP (2) 168 AP IP (3) 000 AP IP (4) 002 Click the ENTER button to enter Wi-Fi Settings. Settings required for Wi-Fi communication. When using Wi-Fi mode, RS485 communication is not available. Product Connector Specifications Connector Specifications Communication Connector Power Connector RJ-45 8p8c (Dual) 2.0PIE DC JACK (12V) Communication Connector Pin Map Specification No Pin Assigned 1 RS485- 2 RS485+ 3 GND 4 GND 5 NC 6 NC 7 NC 8 NC Product Appearance Product Dimensions Communication Connector <UP> Power Connector Wi-Fi Antenna Vent Hole < Left Side > <Front> <DOWN> D/L Connector Dust Outlet Dust Inlet <Right Side> Status LED <Rear> Products handling precaution There is a risk of electric shock to this product, so do not open the product while power is applied. Be sure to install this product on a fixed location such as a rack or panel. Do not touch the power plug with wet hands. It may cause electric shock or injury. Supply the power input within the specified rating range. Be careful not to let water or beverages enter the product. Clean regularly with a soft cloth or brush. If the dust inlet and outlet are blocked, it may cause product failure. To prevent inductive noise, separate wiring from high-voltage lines and power lines. Avoid installation in places subject to strong magnetism, noise, vibration and impact. When extending the sensor wire, use a shield wire and do not make it unnecessarily long. Sensor wire and signal wire should be wired independently away from power, power and load wires. Avoid using near devices that generate strong high-frequency noise (high-frequency welding machine, high-frequency sewing machine, high-frequency radio, large-capacity SCR controller). Some measurement errors may occur depending on the usage environment and usage method. Do not disassemble the product arbitrarily. (Warranty does not apply to products that have been disassembled.) We are not responsible for product damage outside of the warranty conditions specified by the manufacturer. It is recommended to calibrate once a year because it can be affected by factors such as temperature, humidity, and shock during the long-term use period. Be sure to observe the contents specified in the handling precautions above as they may cause product failure. The specifications and dimensions described in this user manual are subject to change without notice for improvement. FCC Instructions FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Radiation Exposure Statement This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This document contains information of products and processes in development. All information provided here is subject to change without notice. Information in this document supersedes and replaces information previously supplied in any prior versions of this document. We do not guarantee the performance of this device in case of disassembling, operating without complying with instructions in this document. Contact your IGS representative to obtain the latest forecast, schedule and specifications. Or It may be obtained by calling +82-2-6299-7536~7 or by visiting http://www.igstech.kr Copyright © 2023 IGS Incorporated. All rights reserved.