Owner's Manual for OVIA models including: OR5, OR5-E, OR5 Rectangular LED Bulkheads, Rectangular LED Bulkheads, LED Bulkheads, Bulkheads
File Info : application/pdf, 2 Pages, 965.75KB
DocumentDocumentWIRING INSTRUCTIONS Suitable cable and power is to be supplied to the point of installation using IP rated connectors/junction boxes used where required. To remove terminal cover, grab the two sides of the ratchet clips. Once terminated ensure cover is pushed firmly over the wires to secure them in place, add a screw for additional security to maintain the IP rating. Depending on the fitting being installed, the cable can be terminated as follows: STANDARD FITTINGS L - (Brown) Switched Live E - (Green/Yellow) Earth N - (Blue) Neutral EMERGENCY BATTERY BACKUP FITTINGS See Notes Below L - (Black) UnSwitched Live Ls- (Brown) Switched Live E - (Green/Yellow) Earth N - (Blue) Neutral NOTE: The emergency battery only fitting can be wired as maintained or non-maintained: · Maintained - The LED driver connects to `Switched Live' with `Unswitched' permanent live to the emergency inverter. (Luminaire can be switched on/ off, but will illuminate at a lower level on power failure) · Non-Maintained - The LED driver is not connected to `Switched Live' with `Unswitched' permanent live to the emergency inverter (luminaire only illuminates on power failure). To enable the MANUAL emergency fittings to be tested, a keyswitch must be fitted inline with the Permanent Live input in to the luminaire. EMERGENCY BATTERY BACKUP - MANUAL TESTING On first operation a 24 hour charge will be required to fully charge the batteries. Failure to provide a permanent live will cause the batteries to power the fitting when it is switched off. This is not recommended as it will reduce the lifetime of the batteries. This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance testing. Irreparable damage will occur if this instruction is not followed. Recommended routine emergency test procedure in accordance with BS 5266. · Daily check - check that the status GREEN LED indicator is illuminated. · Monthly functional test - simulate a mains supply failure for approx. 30 secs by operation of key switch or switching off a circuit breaker. Ensure normal supply is restored after test and the indicator status LED is illuminated. · Annual full three hour duration test - conduct a three hour continuous duration test. Simulate a mains supply failure for three hour continuous test by operation of key switch or switching off circuit breaker. Ensure normal supply is restored after test and the indicator status LED is illuminated. If the luminaire fails any of the function or duration tests, please contact a qualified electrician. SPECIFICATIONS: Product Code Wattage Dimensions IP Rating Colour Temperature Dimmable Emergency Fitting Battery Specification Fitting Net Weight Input Voltage/Frequency Body Material Warranty OR5 5W No N/A 0.446Kg OR5-E 7.5W 244mm x 125mm x 96mm IP65 CTA Switchable - 3000K, 4000K & 6500K No Yes 6.4V 1500mAH LiFePO4 0.646Kg 220-240V~ 50/60Hz Polycarbonate 3 Years COMPLIANT WITH: The Rectangular LED Bulkheads have been tested and comply with the following statutory instruments, directives & standards: · LV (2014/35) & EMC (2014/30) · BS EN 60598-1 · BS EN 60598-2-1 · IEC 62471 · BS EN 55015 · BS EN 61000-3-2 · BS EN 61000-3-3 · BS EN 61547 Errors & Omissions excluded. Specification is subject to change without notice. OVIA Limited, Scolmore House, Mariner, Lichfield Road Ind. Estate, Tamworth, Staffordshire, B79 7UL Telephone: 01827 300640 E-mail: technical@oviaUK.com Website: www.oviaUK.com V1 Installation, Technical & Safety Information Sheet REX OR5 & OR5-E Range of 230V~ 5W CTA Switchable Rectangular LED Bulkheads (Standard or Emergency) GENERAL INFORMATION PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCE. Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of this product, consult a competent electrician. · Before commencing any electrical work, to prevent the possibility of receiving an electric shock, ensure the mains isolator on the consumer unit is in the `OFF' position and safely isolated in accordance with Best Practice Guide 3. · If in doubt consult a qualified electrician. The luminaire must be installed in accordance with the latest IET Wiring Regulations, BS7671. If this product is being fitted as a replacement part to an existing installation account must be taken to the version of the wiring regulations it was installed to. · Before commencing installation, ensure the fitting is complete with the fixings required. · The fitting should be mounted on a smooth, flat surface, noting the position of any pipes or wiring behind the fixed surface to prevent the risk of damage. · The LED light source is not dimmable. · The LED light source is not user-replaceable. · The LED light source is replaceable by professionals only. · The LED light source contained within this luminaire has an energy classification value of D. INSTALLATION Fig 1. Fig 2. Fig 3. Fig 4. Fig 1. Loosen the four screws and remove diffuser. Fig 5. Fig 2. Unlock LED array by sliding the PCB board over, allowing the screw heads to pass through the larger holes. Fig 6. Fig 3. Lift LED array away from base. Fig 7. Drill holes Fig 4. Drill the 4 fixing points out of the base of the fitting. Fig 8. Fig 5. Choose cable entry point by removing either the rear or side knockouts. Gland M20 (not supplied) must be used for all side knockouts. Fig 9. Fig 9. Slide LED array back into original position to lock into place. Fig 6. Using the 4 x fixing screws provided, fix the fitting onto the mounting surface. Fig 10. Fig 7. On the back of the LED array, terminate the cable accordingly and secure via the cable clamp. Fig 11. Fig 8. Refit the LED array into the base. Additional Accessories ON 12 1 2 CCT ON OFF3000K ON ON 4000K OFF ON 6500K Fig 10. Set colour temperature by adjusting the DIP switches accordingly OR5BT - Black Rectangular Trim Fig 11. Refit the diffuser and secure with the four securing screws supplied (Standard or Anti-Tamper) OR5RD - Red Rectangular Diffuser