Miele PDR 508 HP P Heat-Pump Dryer
Installation Plan and Technical Data
Introduction
This document provides essential information for the installation and operation of the Miele PDR 508 HP P heat-pump dryer. It is crucial to read the operating and installation instructions before installation and commissioning to prevent personal injury and damage to the appliance.
Key Definitions
- AL: Exhaust air
- ASK: Condensate drain hose
- B: Appliance anchoring
- EL: Electrical connection
- F: Appliance feet, adjustable
- KG: Payment system
- KGA: Payment system connection
- KLA: Cooling air vent
- KLZ: Cooling air intake
- PA: Equipotential bonding
- SLA: Peak-load connection
- APCL SST: Box plinth
- APCL OB: Open plinth
- APCL 001: Washer-dryer stacking kit
- XKM: Communication module
- ZL: Air intake
Installation Requirements
General
The tumble dryer must be connected to a power supply compliant with all appropriate local and national legislation and regulations, including those from utilities and occupational safety standards.
Refrigerant Safety (R290)
The R290 refrigerant is flammable and explosive. In case of damage:
- Avoid naked flames or sparks.
- Disconnect the dryer from the electrical supply.
- Ventilate the room.
- Contact Miele Customer Service.
Protect the dryer from damage and do not make alterations.
Operating Conditions
Ambient Temperature: +2 °C to +35 °C.
Adequate room ventilation is essential, especially in small rooms, as expelled air is warm. Avoid high room temperatures; switch off other heat-producing appliances if necessary to prevent increased running times and energy consumption.
Electrical Connection
The dryer is supplied with a mains cable and plug. Connection must be to an electrical system conforming to national and local codes (e.g., BS 7671 in the UK). Do not use extension cables or power strips to avoid fire risk.
Ensure the data plate specifications match the power supply. For hard-wired appliances, a dual circuit breaker with a minimum 3 mm all-pole contact gap is required. The isolator switch or plug must be easily accessible and lockable if the appliance is disconnected.
All new connections, system modifications, or earthing conductor servicing must be performed by a qualified electrician.
Condensate Drain Hose
Condensed water is pumped away via a drain hose at the back of the dryer. The drain pump has a 1m delivery head. Ensure the hose is free of kinks for proper drainage.
A non-return valve (optional accessory) may be required to prevent water flowing back into the dryer, which could cause damage.
Drainage Options:
- Direct connection to a plastic drain pipe: Use a non-return valve if the hose end might be submerged.
- Connection to a washbasin: Use a plastic nipple and always a non-return valve.
- Connection to a floor drain (gully): Always use a non-return valve.
- Directed into a sink or basin: Secure the hose carefully to prevent slipping. Use a non-return valve if the hose end might be submerged.
Equipotential Bonding
If required, equipotential bonding with good galvanic contact must be ensured according to local and national installation specifications. Connection material can be provided on-site or via Miele Customer Service.
Peak Load/Energy Management (SLA)
The dryer can connect to peak-load or energy management systems via an optional kit. When activated, the heating is deactivated, and a display message is shown.
Payment System (KGA)
A single-machine payment system can be fitted using an optional kit (XCI-Box / XCI-AD). Programming is done during initial commissioning; subsequent changes require Miele dealer or Customer Service intervention.
Interface (XKM)
An APCL106 communication module can be fitted for WiFi or LAN interface. The LAN connection complies with SELV (Safety Extra Low Voltage) and uses an RJ45 connector.
Appliance Dimensions and Clearances
The following dimensions and clearances are recommendations for easier service work. If installation space is limited, the machine can be pushed up against the wall.
Dimensions
Dimension | Value | Notes |
---|---|---|
Overall Appliance (H/W/D) | 850/605/777 mm | |
Casing (H/W/D) | 850/596/737 mm | |
Door Opening Diameter | 457 mm | |
Appliance Weight (Net) | 68.5 kg | |
Max. Floor Load in Operation | 925 N | |
Sound Pressure Level | <70 dB(A) | (in accordance with EN ISO 11204/11203) |
Heat Dissipation Rate | 950 W | to installation site |
Installation Clearances
Clearance Type | Value | Notes |
---|---|---|
Side Gap | 20 mm | |
Recommended Side Gap (Washer-Dryer Stack) | 300 mm | |
Distance to Opposite Wall (from appliance front) | 1000 mm | |
Minimum Site-Access Opening (excl. packaging) | 900/605 mm | (H/W) |
Diagrammatic representations show connection points: EL (Electrical connection), ASK (Condensate drain hose), F (Appliance feet), KGA (Payment system connection), SLA (Peak-load connection), XKM (Communication module), PA (Equipotential bonding).
Plinth Installation
The dryer can be installed on a plinth (optional Miele accessory: open or box plinth) or a site-provided concrete plinth. The concrete quality and strength must be assessed for the appliance load. Raised plinths must be adequately bonded to the floor.
Anchoring (B): Miele plinths require specific fasteners. For site-provided plinths, anchor points are needed. Wood screws (8x65 mm) and Rawl plugs (12x60 mm) are specified for anchoring.
Plinth Floor Anchoring: For on-site plinths (concrete/masonry), a minimum footprint of 600/650 mm (W/D) is recommended. Wood screws (6x50 mm) and Rawl plugs (8x40 mm) are specified.
Washer-Dryer Stack
The dryer can be stacked with a Miele washing machine using a stacking kit (optional accessory), requiring professional installation. Stacking on a Miele plinth is not permitted. The washing machine is secured with a supplied bracket.
Dryer Stack with 2 Tumble Dryers
Two Miele tumble dryers can be stacked using a stacking kit (optional accessory), requiring professional installation. Stacking on a Miele plinth is not permitted. The bottom dryer must be secured with 2 tensioning strips (optional accessories) at the front/rear or rear only to prevent slipping or tipping.
Permitted Dryer Stack Combinations (2 Dryers)
Dryer Model at the Bottom | Dryer Model at the Top | Connection Kit |
---|---|---|
PDR 3xx/5xx/9xx HP P | PDR 3xx/5xx/9xx HP P | APCL 001 |
PDR 3xx/5xx/9xx HP P | PDR 3xx/5xx/9xx ROP EL | APCL 001 |
PDR 3xx/5xx/9xx ROP EL | PDR 3xx/5xx/9xx HP P | APCL 001 |
Only "Little Giants" models listed are permitted in these combinations.
Technical Data Summary
Drying System & Capacity
Parameter | Value |
---|---|
Drying System | Heat pump |
Drum Volume | 130 l |
Load Capacity | 8.0 kg |
Door Opening Diameter | 370 mm |
Electrical Connection (EL)
Parameter | Value |
---|---|
Standard Voltage | 1N AC 220-240 V |
Frequency | 50 Hz |
Total Rated Load | 1.44 kW |
Fuse Rating (B trip rating according to EN 60898) | 1 x 10 A |
Supply Lead Min. Cross-section | 3 x 1.5 mm² |
Length of Supply Lead | 2000 mm |
Condensate Drain Hose (ASK)
Parameter | Value |
---|---|
Max. Drainage Temperature | 70 °C |
Max. Transient Flow Rate | 3.6 l/min |
On-site Hose Sleeve for Drain Hose | 10 x 30 mm |
Drain Hose (Internal Diameter) | 10 mm (DN10) |
Length of Drain Hose | 1500 mm |
Max. Delivery Head (from lower edge of appliance) | 1000 mm |
Connections & Interfaces
Parameter | Status/Details |
---|---|
Equipotential Bonding (PA) | Connection requires separate kit (standard: , optional: ) |
XCI-Box / XCI-AD Interface | (standard: , optional: ) |
Peak Load/Energy Management (SLA) | Appliance connection (with XCI-Box) (standard: , optional: ) |
Payment System Connection (KGA) | Connection of payment systems (with XCI-Box / XCI-AD) (standard: , optional: ) |
Communication Module (XKM) | Communication module APCL 106 (standard: , optional: ) |
Installation on Appliance Feet (F)
Parameter | Value |
---|---|
No. of Appliance Feet | 4 |
Appliance Foot, Height-Adjustable with Thread | ± 5 mm |
Appliance Foot Diameter | 31.7 mm |
Anchoring (B)
Parameter | Value |
---|---|
Anchoring of Miele Plinths | Miele plinth installation (fasteners included) (standard: , optional: ) |
Required Anchor Points | 4 |
Wood Screws (according to DIN 571) | 8 x 65 mm |
Rawl Plugs (diameter x length) | 12 x 60 mm |
Plinth Floor Anchoring (On-site)
Parameter | Value |
---|---|
Appliance Installation on On-site Plinth (concrete or masonry) | (standard: , optional: ) |
Min. Plinth Installation Footprint (W/D) | 600/650 mm |
Wood Screws (according to DIN 571) | 6 x 50 mm |
Rawl Plugs (diameter x length) | 8 x 40 mm |
Note: = standard, = optional, + = only on request, - = not available.
Distributor Information
Miele provides professional sales and support across various regions. Contact details for Miele offices in the United Kingdom, Australia, China Mainland, Hong Kong, India, Ireland, Malaysia, New Zealand, Singapore, South Africa, and the United Arab Emirates are available for customer service and inquiries.