User Manual for UNI-T models including: UDP6720 Series, Digital Control Power Supply, UDP6720 Series Digital Control Power Supply, UDP6700

UT3500 用户手册

UT

UDP6700-Power Supplies-UNI-T Voltage Meter, Multimeter, Oscilloscope | UNI-T-UNI-T Voltage Meter, Multimeter, Oscilloscope | UNI-T

UT3500 用户手册

UDP6700-DC Power Supplies-UNI-T Voltage Meter, Multimeter, Oscilloscope | UNI-T-UNI-T Voltage Meter, Multimeter, Oscilloscope | UNI-T


File Info : application/pdf, 21 Pages, 1.67MB

PDF preview unavailable. Download the PDF instead.

1653961549794026
UDP6720 Series Digital Control Power Supply
User's Manual

UDP6720 Series Digital Control Power Supply User's Manual
Perface
Thank you for purchasing this brand new product digital control power supply. In order to use this product safely and correctly, please read this manual thoroughly, especially the safety notes.
Copyright Information
Copyright is owned by Uni-Trend Technology (China) Co., Ltd.
UNI-T products are protected by patent rights in China and other countries, including issued and pending patents. UniTrend reserves the rights to any product specification and pricing changes.
Uni-Trend Technology (China) Co., Ltd. all rights reserved. Trend reserves all rights. Information in this manual supersedes all previously published versions. No part of this manual may be copied, extracted or translated by any means without the prior permission of Uni Trend.
UNI-T is the registered trademark of Uni Trend Technology (China) Co., Ltd.
Warranty Service
The instrument has a warranty period of one year from the date of purchase. If the instrument is damaged due to improper operation by the user during the warranty period, the maintenance fee and the costs caused by the maintenance shall be borne by the user, and the instrument shall be maintained by the company for life.
If the original purchaser sells or transfers the product to a third party within one year from the date of purchase of the product, the warranty period of one year shall be from the date of the original purchase from UNI-T or an authorized UNl-T distributor. Power cords, accessories and fuses, etc. are not included in this warranty.
If the product is proved to be defective within the warranty period, UNI-T reserves the rights to either repair the defective product without charging of parts and labor, or exchange the defected product to a working equivalent product (determined by UNI-T). Replacement parts, modules and products may be brand new, or perform at the same specifications as brand new products. All original parts, modules, or products which were defective become the property of UNI-T.
The "customer" refers to the individual or entity that is declared in the guarantee. In order to obtain the warranty service, "customer "must inform the defects within the applicable warranty period to UNI-T, and perform appropriate arrangements for the warranty service.
The customer shall be responsible for packing and shipping the defective products to the individual or entity that is declared in the guarantee. In order obtain the warranty service, customer must inform the defects within the applicable warranty period to UNI-T, and perform appropriate arrangements for the warranty service. The customer shall be responsible for packing and shipping the defective products to the designated maintenance center of UNI-T, pay the shipping cost, and provide a copy of the purchase receipt of the original purchaser. If the products is shipped domestically to the purchase receipt of the original purchaser. If the product is shipped to the location of the UNI-T service center, UNI-T shall pay the return shipping fee. If the product is sent to any other location, the customer shall be responsible for all shipping, duties, taxes, and any other expenses.
2

Limited Warranty and Liability

UDP6720 Series Digital Control Power Supply User's Manual

The warranty is inapplicable to any defects, failures or damages caused by accident, normal wear of components, use beyond specified scope or improper use of product, or improper or insufficient maintenance. UNI-T is not obliged to provide the services below as prescribed by the warranty: a) Repair damage caused by installation, repair or maintenance of personnel other than service representatives of UNI-T; b) Repair damage caused by improper use or connection to incompatible equipment; c) Repair any damages or failures caused by using power source not provided by UNI-T; d) Repair products that have been changed or integrated with other products (if such change or integration increases time or difficulty of repair).

The warranty is formulated by UNI-T for this product, replacing any other express or implied warranties. UNI-T and its distributors refuse to give any implied warranty for marketability or applicability for special purpose. For violation of the warranty, repair or replacement of defective products is the only and all remedial measure UNI-T provides for customers.
No matter whether UNI-T and its distributors are informed of any possible indirect, special, occasional or inevitable damage in advance, they assume no responsibility for such damage.

Safety Information

Warning Caution
To avoid possible electric shock and personal safety problem, please follow the instructions below.

Disclaimer Instrument Grounding

Please read the following safety information carefully beforestarting to use the instrument. Uni-Trend will not be responsible for the personal safety and property damage caused by the user's failure to comply with the following terms.
To prevent the risk of electric shock, please connect the power ground wire.

Operating voltage

Please make sure operating voltage under rated range of 10%, to avoid damage the instrument.

Input voltage

Please use AC 110V~220V 50/60Hz AC power supply, use national approved power cord and make sure insulating layer is in good condition.

Inspecting the wire of the instrument

Inspecting the condtion of the insulating layer of the wire, check if it is broken, bareness or workable. If the wire is damaged, please replace it before connect with the instrument.

Fuse wire of the instrument Only allowed use the dictated specification fuse wire.

Over-voltage protection

Please make sure the instrument is not over-voltagesuch as the voltage casused by thunder. To prevent operating personnel away from electric shock.

3

UDP6720 Series Digital Control Power Supply User's Manual

Do Not open the cover when the instrument is inoperating

Please do not operating the instrument when open the cover and do not change the internal circuit.

Do Not touch live part

When the instrument is in operating, do not touch the bare connect wire, spare input terminal and the circuit is in testing. When the instrument is over DC 60V or AC 30V, be careful electric shock.

Do Not use the instrument in an
explosive atmosphere

Do not use the instrument in flammable and explosive gas, steam or dusty environment. The use of any electronic equipment in such an environment is a risk to personal safety.

Safety Mark

Grounding Protective Grounding
Signal Ground Dangerous Mark

On (Power) Off (Power) Connect with Cabinet or Case

Environment-friendly Use Period
EFUP is the period of time before any of the RoHS substances are likely to leak out, causing possible harm to health and the environment. EFUP of this instrument is 40 years, it should be recycling system when exceed 40 years.
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
Must not be discarded in the trash can.

4

UDP6720 Series Digital Control Power Supply User's Manual

Product Series

UDP6720 Series Digital Control Power has two models, UDP6720 and UDP6721.

Output range as follows,

Model

Output Range

UDP6720

0-60V0-5A, 0-100W

UDP6721

0-60V0-8A, 0-180W

Characteristics
 Fully digital control  High resolution 10mV/1mA in full range  Low ripple and noise  Software cailbration  Smallest outline  High-definition LCD display  Remote Sensecompensaton  Support RS-232 communication  Intelligent fan regulation  Rated voltage and current output·  High-reliability: OVP(over voltage protection)/OCP(over current protection)/OTP(over temperature protection)  Output on/off control  High performance-price ratio  Storage for 3x200 preset voltage and current output
Basic Performance
UDP6721/UDP6721 digital control power supply with widest voltage and current range, it can applied in many fields. Take UDP6720 for example, with max power 100W and ouput adjustable in 60V/5A, auto control voltage and current slew rate, power rate up to three times rapid than other similar products. One instrument can replace three models (60V×1.6A/32V×3A/20V×5A), save your repeat investment.
Example Take UDP6720 for example,set output voltage as 60V, because the max power of UDP6720 is 100W, so the max output current is 100W/60V=1.66A. When output voltage down to 20V, the max output current turns to 100W/20V=5A. The max output current of UDP6720 is 5A, if the current output voltage continue decrease , the max output current of UDP6720 still as 5A.

UDP6720 Operating Curve

UDP6721 Operating Curve

5

Specifications
Specification
Output Range
Load Regulation Power Supply Regulation Programming Accuracy Read-back Accuracy
Ripple and Noise Dimension Weight

Voltage Current Power Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current W×H×D
Net

Front Panel

UDP6720 Series Digital Control Power Supply User's Manual

UDP6720 0~60V 0~5A 100W
<0.01%+3mV <0.01%+3mA <0.01%+3mV <0.1%+3mA <0.05%+10mV <0.2%+2mA <0.05%+10mV <0.1%+2mA <2.0mV rms <5.0mA rms 87×174×255(mm)
<2.5Kg

UDP6721 0~60V 0~8A 180W
<0.01%+5mV <0.01%+5mA <0.01%+5mV <0.1%+5mA <0.05%+10mV <0.3%+5mA <0.05%+10mV <0.3%+5mA <5.0mV rms <8.0mA rms 87×174×255(mm)
<2.5Kg

6

Rear Panel

UDP6720 Series Digital Control Power Supply User's Manual

Packing List
Befor use the instrument, please, 1Check whether the appearance is damaged, scratched or has other defects; 2Check with packing list to confirm that accessories has no loss. If there have any problem, please contact with Uni-Trend Instrument Sale Department or the distributor.

Components The instrument

Quantity 1

Remarks The model is subject to the actual order

3C power line
250V/3.15A spare fuse UDP6720
250V/5A spare fuse UDP6721
Alligator cips with parallerl wire
User's Manual /Upper-computer software

1

1

1

1

1

Electronic filedownload from the official

website

7

UDP6720 Series Digital Control Power Supply User's Manual

Requirments of Power Supply
UDP6720 series digital control power supply can only use under the power supply terms as the table below.

Parameter

Requirements

Voltage

AC110/ 220(±10%)V

Frequency

50/60Hz

Fuse UDP6720

AC110V input voltage250V/3.15A

Fuse UDP6721

AC110V input voltage110V/5A

 Factory supply three-core power cable, please make sure power cable of three phase socket is connect with ground before use.
 This instrument 110V is select fuse of 250V/3.15A or 250V/5A, the specification is 5× 20mmit all set and equip with spare fuse of 250V/3.15A or 250V/5A in fuse box before the product leave the factory.
 Please remove the external power cable before replace the fuse, open the fuse socket slot under the power supply plug, take out the old fuse and replace the new fuse into it, after that the instrument can be used normally.

WarningDo not use power cable with any signs of damage to avoid danger!

Operating Environment

UDP6720 series digital control power supply can only use in normal termperature and low condensing zone. The general environmental requirements of the instruments is listed as the below table.

Operating Environment

Environmental Requirements

Temperature

0~45

Humidity Storage temperature

20%~80%non- condensation -20~70

Altitude

2000 meter

Pollution degree

2

ExplanationIn order to guarantee the accurancy of measurement, it is suggested that turn on the instrument
half an hour before operating. Cleaning
To prevent from the risk of electric shock, please pull out power line befor cleaning. Please use a clean cloth dipped in clean water to clean the cover and panel. Do not clean the inside of the instrument.

CautionDo not use solvents (alcohol or gasoline etc.) to clean the instrument.

8

Quick Start

UDP6720 Series Digital Control Power Supply User's Manual

Apparance Inspection

1. Check out the instrument is in a good condition during the delivery. If there have any problem, please contact with Uni-Trend Instrument Sale Department or the distributor.
2. Confirm whether the AC input voltage of UDP6720/UDP6721 comply with the standards of your country or region.
Notice: Use 110V/220V switch on the rear panel to select input voltage. After confirming the above matters, power on the instrument.

Voltage Setup

1) Push 2) Push

key to set voltage value;

or

to select the specific numeric field;

3) Rotating

to enter the definited voltage parameter.

1 3
2

9

Current Setup

UDP6720 Series Digital Control Power Supply User's Manual

1) Push 2) Push

key to set current value; or to select the specific numeric field;

3) Rotating

to enter the definited current parameter.

3 1
2

Enable Output

1) Push

to enable power output function and the indicator light will be green. In the mean time, C.V/C.C indicator

light will be green or red light according to the different output mode;

2) OUTPUT key indicator light will be off when OUTPUT function is disable. C.V/C.C indicator light will also be off.

10

UDP6720 Series Digital Control Power Supply User's Manual
Keyboard Lock
Lock keyboard function is prevent unauthorized worker or operating personnel form making accident operation. To avoid damage the device under test. 1) Push Lock key to enable lock keyboard function and the indicator light will be green. Lock symbol will shown on the top
of screen. 2) In lock status, long push Lock key to unlock the function and indicator light will be off. Lock symbol will also disappear
on the screen.

OVP Function

1) Long push

2) Push

or

key to set OVP function; to select the specific numeric field and enter OVP parameters;

3) Push

or

to enable OVP function;

4) When the OVP function set successfully,  mark will shown beside OVP parameters.

1 3 2
11

OCP Function

UDP6720 Series Digital Control Power Supply User's Manual

1) Long pushk

2) Push

or

key to set OVP function; to select the specific numeric field and enter OCP parameters;

3) Push

or

to enable OCP function;

4) When the OCP function set successfully,  mark will shown beside OCP parameters.

3 1
2

Bepper Switch

1) Push

to enter the setup interface, rotate

to adjusting buzzer mode;

2) When the buzzer function is enable, keyboard sound is also turn on; when the buzzer function is disable, keuboard

sound will be silent. Buzzer status will shown on the top screen.

3) Push

to exit the setup page.

3

12

Brightness Setup

UDP6720 Series Digital Control Power Supply User's Manual

1) Push 2) Push 3) Rotate 4) Push

to enter the setup interface;

or

to select Brightness field;

to set the brightness, adjusting range 0~100%;

to exit the setup page.

3
1 2

Memory Group Setup

1) Push 2) Push
3) Rotate 4) Push

to enter setup interface;

or

to select Memory option;

to set memory group, the maximum range is 200; to exit the setup page.

13

UDP6720 Series Digital Control Power Supply User's Manual
Memory Group Voltage/Current Setup
Set the specific output voltage/current point and select memory key M1~M3, push it to save the current setting. When user need to call the stored output voltage/current, enter the setup interface to select the specific memory group and then push memory key M1~M3 to call the specific stored output voltage/current. When user call the stored output voltage/current, the corresponding memory key will indicate green light.

Output Mode Setup

1) Push 2) Push

to enter setup interface;

or

to select the output status bar;

3) Rotate

to select Out State;

4) Output status symbol will shown on the top screen when output is finished;

5) Push

to exit the setup page.

Notice: When output function is operating, power supply should remain enable status. That is, operating status when turn off the power supply.

should keep

14

Language Setup

UDP6720 Series Digital Control Power Supply User's Manual

1) Push 2) Push
3) Rotate 4) Push

to enter setup interface;

or

to select language field;

to select Languge type (English/Chinese); to exit the setup page.

Display Interface Information

1) Push

to enter the setup interface;

2) Use left, right arrow key to select the IO Information option;

3) RS232 configuration information will shown on the right side of the screen.

15

About

UDP6720 Series Digital Control Power Supply User's Manual

1) Push

to enter the setup interface;

2) Push

or

to select About field;

3) The device information product's model and the current version number will shown on the right side of the

screen.

Remote Sense Compensation Setup
Before use Remote Sense compensation function, take off short connect terminal on the Remote Sense compensation terminal, connect load voltage positive terminal to compensation terminal S+ and load voltage negative terminal connect to compensation terminal S-. And then enable power output to turn on Remote Sense compensation function. That is, the output voltage of the DC power supply is the voltage of the load terminal. Notice: Remote Sense compensation voltage should less than 0.6V.

16

UDP6720 Series Digital Control Power Supply User's Manual
CV/CC Operating Mode of Power Supply
Power supply can automatic transfer constant voltage/current function. Power supply can ongoing switch the constant voltage/current function dependends on load fluctuation. If the current load is on the constant voltage mode, power supply provide a controlled output and voltage. As the load resistance value decreases, the output voltage remains constant until the output current increases to greater than the preset current value, which it will convert operating mode. If the power supply turn into constant current output, the output voltage will decrease proportionally according to resistance value of the load. When the current value less than the set value, power supply will back to the constant voltage mode.
Troubleshooting
Power supply is no output 1 Check the set value of voltage and current is zero or not. If it is, reset the voltage and crrent value. 2 OUTPUT indicator light is light on or not. If it is, push OUTPUT key to enable the output function. 3 Check OVPOCPOTP function is activated or not. If it is, reset the value of OVP, OCP and wait the power supply
remain stable to turn the output function. 4 If Remote Sense compensation function has been enabled, check the line loss of output cable is excced thelimit
value or not. If it is, replace the output cable or decrease the output current, and then try to enable the power supply again. The keyboard is not work Check Lock indicator light is light on or not. If it is, please refer to Lock section to reset again.
Remote Communication
The installment and startup configuration file 1. Download the installment file from official website; 2. Turn on power supply 3. Connect the control line of RS232 to control power supply 4. Activate the remote controlling application program 5. Click Euqipments List, and double-click the power supply symbol of UDP6720 or UDP6721 to enter the remote
communication interface.
17

UDP6720 Series Digital Control Power Supply User's Manual

Remote Control Interface & Operating Instructions

Device selection Pause
Data acquisition configuration
Power output display
OVP protection
Voltage/Current setup

Language Option

Operating interface

Quick set of voltage/current OCP protection
Output record of voltage/current

ON/OFF Memory group setup

List Mode (Time Function) and Delayer Mode
List Mode List mode can setup multiple testing program, it can set 48 groups of independentant voltage, current and parameter of output duration time.
Delayer Mode Delayer mode can setup multiple testing program to control output status, which is set count to control output status is on or off, and the time interval of switch can also set by point to point. Delayer mode can set 48 output status groups to control parameter. Output parameter of list/delayer mode can all store in internal storage. It has powerdown function. Storage space for each group is 48

Operating Steps
1. Push power supply switch to turn on the instrument; 2. Turn on list mode/ delayer mode

Push arrow key

or

to enter setup interface of list/delayer mode. It can be circular switch.

Notice

a.List/delayer mode and channel output function can't use at the same time, it can only choose either-or; b.When List mode status is pause, delayer mode can't set parameter. It should enter setup interface of list mode to switch

to

, and the status is pause and then to set parameter;

18

UDP6720 Series Digital Control Power Supply User's Manual

3. Connect with load 4. Set parameter of list/delayer mode
Please refer to section Parameter Setting of List Mode and Parameter setting of Delayer Mode. 5. Enable timing/delayer output

In timing/delayer interface, rotate rotary knob

to

and push

to enable timing/delayer output

function. Symbol

turn to

and status bar will also change to "stop" to "run";

6. Disable timing/delayer output

In timing/delayer interface, rotate rotary knob

to and push

to disable timing/delayer output function.

Symbol

turn to

and status bar will also change to "run" to "stop";

Another shorcut to disable output function, push

key to turn off timing/delayer function in any interface.

Parameter Setting of List Mode

Menu introduction of list mode

Interface of List Mode

Cycle indexIt divide into maximum inf and 1-999. A cycle period is start form setup origin point to end point. Push rotary

knob

to adjusting parameters.

Count: It can set "001" - "048", which is excute group from origin point to end point. Push rotary knob point. Notice: each voltage, current and time is a point.

to adjusting

Origin point: It can adjust "000"-"047", which is start from origin point to run. ("origin point" value + "count" value 

048)

Mode: It divide into three mode stop, run and pasue, it can not be set

Pause presents power supply is not output at the current

Run presents power supply is operating

Pause presents power supply is paused

NoticeIn pause and run mode, interface can not be adjust; pause only shown when indicator

is off and only

shown on

interface.

The Curve Figure of Count Parameter This curve figure can direct present the setting parameter of list mode.
19

UDP6720 Series Digital Control Power Supply User's Manual

Count Configuration Table of List Mode

Table settingserial number of each group is corresponding to voltage, current and time value, push rotary knob

to

set parameter;

Voltageadjust the actual output voltage value

Currentadjust the current value

Timeduration output time value in this serial number

,

: operating status at the current, push rotary knob

to switch mode

Save: save the setting parameter for powerdown function, push rotary knob

to save the current setting;

: clear parameter values in the table all to zero (voltage 00.00, current 00.00, time 00.00), push rotary knob

to eliminate the setting parameter values in the table; Notice: clear select function is eliminate the corresponding group of origin point to count.

Parameter Setting of Delayer Mode

Interface of Delayer Mode

It presents power output status and delayer time of user configurationit's convenient to view the data.

Protection settingthis function can set protection value of voltage, current and power, push rotary knob select ""to turn on protection function

Cycle indexIt divide into maximum inf and 1-999. A cycle period is start form setup origin point to end point;

CountIt can set "001" - "048", which is excute group from origin point to end point. Push rotary knob

to

adjusting parameter;

Origin point: It can adjust"000""- 047", which is start from origin point to run. Push rotary knob parameter ("origin point" value + "count" value  048) Mode: It divide into three mode stop, run and pasue, it can not set

to adjusting

20

UDP6720 Series Digital Control Power Supply User's Manual
Stop presents power supply is not output at the current Run presents power supply is operating Pause presents power supply is paused NoticeIn pause and run mode, interface can not be adjust; pause only shown when protection function is enabled.

Table settingserial number of each group is corresponding to output status and delay time, push rotary knob to set parameter ModeON presents output function is enabled, OFF presents output function is disabled Timeset the delay time of the main interface

,

: operating status at the current, push rotary knob

to switch mode

Save: save the setting parameter for powerdown function, push rotary knob

to save the current setting;

: clear parameter values in the table all to zero (voltage 00.00, current 00.00, time 00.00), push rotary

knob

to eliminate the setting parameter values in the table;

Notice: clear select function is eliminate the corresponding group of origin point to count.

21


Microsoft Word 2013 Microsoft Word 2013