Emerald Air Conditioning

Multi-Head Ultra 18kW

Product Data Sheet

This air conditioning system features high speed DC dual-rotor technology for efficient and quiet operation, suitable for commercial and residential use. It operates effectively across a voltage range of 198V to 264V and diverse temperatures. Golden Fin technology enhances anti-corrosion properties, extending its lifespan and maintaining performance. Its design allows flexible installation with long refrigerant piping and includes a strong insect guard for cleaner internals. Backed by a 5 year system warranty and 2 year labor warranty, it ensures quality and peace of mind.

Warranty: 5 years system, 2 years labor and service.

Features

Specifications - Outdoor Unit

Specification Emerald Model ACV180U
Power supply 220-240V ~ 50Hz
Nominal capacity (Cooling) kW 18.10
Power consumption (Cooling) kW 5.14
AEER W/W 3.30
Nominal capacity (Heating) kW 20.40
Power consumption (Heating) kW 4.19
ACOP W/W 4.51
HSPF res cold 3.883
TCSPF res cold 5.278
Sound power level (Normal mode) dB(A) 75
Cabinet color Ivory white
Outer dimensions Height mm 1080
Width mm 980
Depth mm 360
Packing dimensions Height mm 1230
Width mm 1100
Depth mm 505
Net weight kg 97
Gross weight kg 110
Compressor Type Rotary
Quantity 1
Refrigeration oil Type RmM68EA
Pre-refrigerant charge Quantity L 1.8
Refrigerating installation Type R410A
Pre-refrigerant charge Quantity kg 3.8
Refrigerant flow control Micro-computer control expansion valve
Heat exchanger type Multi-way cross-flow finned tube type
Piping design Gas pipe mm (in.) Ø19.05(3/4")
Liquid pipe mm (in.) Ø9.53(3/8")
Connectable indoor units Quantity pc 2-11
Connection ratio % 50-150
Max. piping length m 40
Total piping length m 120
Piping design Height difference between ODU and IDU m 30
Height difference between IDUs m 10
Pressure (high/low pressure) MPa 4.30/2.21
Condenser fan Quantity 1
Airflow rate m³/min 93
Operation Range Cooling DB(°C) -5~55
Heating DB(°C) -20~23

Specifications - Indoor Unit Types

Indoor unit type Emerald model ACV28W Wall Mounted Type ACV45W ACV71W
Power supply AC 10, 220~240V/50Hz; AC 14, 220V/60Hz
Nominal cooling capacity kW 2.8 4.5 7.1
Nominal heating capacity kW 3.3 5.0 8.0
Cooling power consumption kW 0.02 0.02 0.05
Heating power consumption kW 0.02 0.03 0.07
Sound pressure level (overall scale) dB(A) 36/35/33/32/30/28 38/37/36/32/31/29 45/42/41/38/35/31
Refrigerant R410A (Nitrogen charged in case of corrosion)
Dimension (H×W×D) mm 270×845×203 315×960×230 315×1120×230
Net weight kg 9.5 13 14.5
Gross weight kg 13 17.5 19
Indoor fan air flow rate m³/h 590/550/520/490/450/420 690/660/620/540/520/480 1200/1080/1020/900/800/700
Piping connection Liquid line mm Ø6.35mm (1/4") Ø9.52mm (3/8") Ø15.9mm (5/8")
Gas line mm Ø9.52mm (3/8") Ø15.9mm (5/8") Ø15.9mm (5/8")
Condensate drain mm Ø6.35mm (1/4") Ø12.7mm (1/2") Ø16mm
Flare-nut connection (with flare nuts)
Packing dimension (H×W×D) mm 375×943×310 430×1223×328 430×1223×328
Packing volume 0.11 0.15 0.17
Standard accessories Wall mounting bracket

PDF preview unavailable. Download the PDF instead.

Emerald-Air-Con-Multi-Head-Ultra-data-sheet Adobe PDF Library 17.0 Adobe InDesign 20.0 (Windows)

Related Documents

Preview Emerald Multi-Head Ultra 18.1kW Air Conditioning Installation Guide
Installation guide for the Emerald Multi-Head Ultra 18.1kW air conditioning system, detailing electrical, refrigerant piping, and system specifications for residential and commercial use.
Preview Emerald Multi-Head Ultra System 18.1kW: Installation Guide
Installation guide for the Emerald Multi-Head Ultra 18.1kW air conditioning system, detailing electrical and refrigerant piping requirements for residential and commercial use.
Preview Emerald Multi-Head Ultra 18.1kW Air Conditioning System - Product Data Sheet
Detailed product data sheet for the Emerald Multi-Head Ultra 18.1kW air conditioning system, featuring VRF technology, wide installation options, smart temperature control, and energy-saving eco mode. Includes technical specifications for outdoor and indoor units.
Preview Emerald ACV200U/ACV200U-1 User Guide and Installation Manual
Comprehensive user guide and installation manual for the Emerald ACV200U/ACV200U-1 Multi-Head & Ducted Ultra Air Conditioning system, covering safety, installation, piping, wiring, and testing procedures.
Preview Emerald Air Conditioning Split System - Product Data Sheet
Product data sheet detailing the features, specifications, and dimensions of Emerald Air Conditioning Split Systems, including models ACSS25, ACSS35, ACSS72, and ACSS76.
Preview Emerald Air Conditioning Split System Select User Guide and Installation Manual
This comprehensive guide provides essential information for the installation, operation, and maintenance of Emerald's Air Conditioning Split System Select models. It details safety procedures, remote control functions, and troubleshooting steps to ensure optimal performance and longevity of your unit.
Preview Emerald Air-Frying Multi Cooker Owner's Manual
Comprehensive owner's manual for the Emerald Air-Frying Multi Cooker (Model SM-AIR-1863), covering safety guidelines, multi-cooker and air fryer settings, operation instructions, care and cleaning, troubleshooting, specifications, and a variety of recipes. Learn how to maximize the use of your versatile kitchen appliance.
Preview Emerald Ducted Ultra 20kW Air Conditioning System - Product Data Sheet
Detailed product data sheet for the Emerald Ducted Ultra 20kW air conditioning system, featuring VRF technology, high static pressure, smart temperature control, and advanced Golden Fin anti-corrosion technology. Includes specifications for both outdoor and indoor units.