User Manual for HDWR Global models including: AC900LF Standalone Access Controller, AC900LF, Standalone Access Controller, Access Controller

Serwis

[PDF] User Manual 125kHz RFID Standalone Access Controller ...

Jul 16, 2024 · After reading the card and entering the corresponding PIN code to open the door, within 5 seconds, press and hold the # button until the green ...

PDF preview unavailable. Download the PDF instead.

SecureEntry-AC900LF MANUAL EN 20240716
User Manual
125kHz RFID Standalone Access Controller
SecureEntry-AC900LF

Table of contents
Specifications: ............................................................................................................................................................... 3 Set contents: ................................................................................................................................................................... 4 Features: ............................................................................................................................................................................ 4 Defaults .............................................................................................................................................................................. 5 Light and sound signals ......................................................................................................................................... 5 Connection Instructions......................................................................................................................................... 6 Detailed programming instructions.............................................................................................................. 8 Reset the programming password...............................................................................................................10 How to use the admin tab .................................................................................................................................... 11 What is a user ID number...................................................................................................................................... 11 PIN code change (in open mode: card + PIN) ....................................................................................... 11
2

Specifications:
· Warranty: 1 year · Device Type: Standalone Access Controller · Verification Type: RFID Card, Password · Operating frequency: 125 kHz · Max number of employees in the base: 1000 · Reading distance: 5 ­ 15 cm · Keyboard and keys: touch · Chip Types Read: EM · Interface: Wiegand 26 Output · Operating Voltage: DC 12V +- 12% · Working Current: 1.2A · Lock relay: DC 12V/3A · Operating temperature: 0°C ~ 45°C · Operating Humidity: 40% - 90% · Product dimensions: 12.3 x 8.4 x 2.3 cm · Package dimensions: 18.5 x 13.9 x 5.5 cm · Product weight: 200 g · Product weight with packaging: 400 g
3

Set contents:
· Standalone Access Controller · Manual
Features:
· Can be connected directly to the electronic lock and doorbell
· Verification via RFID card and password · 125 kHz operating frequency and DC12V operating voltage
4

Defaults

Password
Backlight Wiegand 26 Opening Mode

Shared

123456

access

lack

password

Relay

Automatic

Unlocking

5 seconds

Output

Input

Safe Mode

disabled

Access card or password

An access password includes a private

access password (PIN) and a shared access

password

Light and sound signals

Light Signal: Red and Green

Description of the light signal

Access Control Status

Red LED flashes every 1 second

slowly

Standby

Red LED on all the time

Programming mode

The green LED is on all the time Unlock Mode

Green LED flashes quickly

Waiting for further actions

every 0.5 seconds

5

Horn: buzzer
Description 1 short beep 3 short beeps 1 long beep A continuous, long beep

Access Control Status Valid input Invalid input Operation success Restoring Factory Programming Passwords

Connection Instructions

Lp. Designation

Colour

1

+12V

Red

2

GND

Black

3

PUSH Blue

4

OPEN Yellow

5

BELL

Grey

6

BELL

Violet

7

DATA0 Green

8

DATE1 White

9

NC

Brown

10

COM Orange

11

YES

Pink

Function Power + PowerLow Output Signal Unlocking the door Bell Bell Wiegand DATA0 Wiegand DATA1 NC relay output Relay Output Com Relay output NO

6

Connection diagram
Remark: If the relay has an electrical interlock, the "+" and "-" poles of the interlock must be connected in reverse.
7

Detailed programming instructions

Basic functions

Purpose
Changing the programming password
Add a user card
Set a common access password
Delete all users
Removing a user by reading the card

Operation to be performed
# Programming password # 0 new programming password #
# Programming password #1 card reading # # Programming password #21 new common password #
# Programming password #40 0000 #
# programming password 41 read card #

Comments
If you lose the programming password, use the default password (123456) If you want to add several cards, read them continuously There is only one common access password. Choose a method: Shared access password # Delete all cards and PINs except for a shared password To remove multiple cards, read the cards continuously

Advanced features

Purpose

Operation to be performed

Comments

8

Add a private access password (PIN)

# Programming password # 22 PIN #

There can be many PIN codes

Add a card by entering the card number
Adding multiple cards by entering the card number
Add a card + PIN
Deleting a user by entering a user ID number Deleting a user by entering a card number Remove a user by entering a PIN
Remove all users' PIN

# Programming password #23 enter card number # # programming password # 24 enter the number of the starter card number number of cards # # programming password # 3 read PIN card # # programming password #42 enter user ID # # Programming password #43 Enter card number # # programming password # 44 enter PIN number # # programming password # 45 1111 #

Changing the opening # programming

time

password # 5 XX #

Set open mode

# programming password # 6 XX #

Reading Setting

# programming password #6 04 #

The card number is 10digit or 8-digit
The number of cards should be 4 digits (if you are adding twenty cards at a time, enter 0020).
The card number is 10digit or 8-digit
PIN consists of 3~6 digits
Applicable to user PIN codes (does not include cards and PIN codes + card) XX can be 2-digit, and max. is 99. If 00 is entered, the signal output time is 0.2 s. XX can be 01 (card only) /02 (card or access password) /03 (card + PIN) The device can be used as a reader (W26 output)

9

Setting the safety function Anti-disconnection alarm setting
Backlight Setting Factory reset
Admin tab setting

# programming

XX can be 01/02 (safety

password # 7 XX #

function OFF/ON) and

03/04 (distance alarm

OFF/ON).

Note: Enabled security feature means that the

system will be locked for 5 minutes if it reads an

unregistered card or the wrong access

password is entered 10 times

# programming

XX can be 01/02/03

password # 8 XX #

(Off/On/Automatic)

# programming

Except for the

password # 8 99 #

programming

password and admin

tab

# programming

The first tab read is the

password #91 read 1 tab added by the

card read 2 cards

administrator, and the

second tab is the card

removed by the

administrator

Reset the programming password
To reset to the factory programming password (123456):
· Turn off the power and connect 2 and 3 RST(S1) · Turn on the power, the buzzer will beep 3 long times and the
green LED will flash. If you need to set an administrator card, read two blank tabs: the first as adding an administrator and the second as removing an administrator card, the second as Removing an administrator card: red LED flashes, a continuous short beep.
10

· Turn off the power, unplug container 2 and 3, and connect container 1 and 2 RST.
· Turn the power back on.
How to use the admin tab
To add a standby user card, follow these steps: Read admin card read new card reread admin card To remove a standby user card, follow these steps: Read admin card read registered card reread admin card To remove all standby users, follow these steps: User cards can be added or removed continuously.
What is a user ID number
A user ID is an automatically generated 4-digit number that starts with 0001. The number increases as you add the user one by one and ignores the deletion of the user. The shared access password does not have an ID number.
PIN code change (in open mode: card + PIN)
After reading the card and entering the corresponding PIN code to open the door, within 5 seconds, press and hold the # button until the green LED flashes rapidly, then enter the new PIN code # new PIN code again #, a long beep indicates the successful change of the PIN code.
11

12


Microsoft Word 2019