User Manual for HDWR Global models including: AC900LF Standalone Access Controller, AC900LF, Standalone Access Controller, Access Controller
Jul 16, 2024 · After reading the card and entering the corresponding PIN code to open the door, within 5 seconds, press and hold the # button until the green ...
User Manual 125kHz RFID Standalone Access Controller SecureEntry-AC900LF Table of contents Specifications: ............................................................................................................................................................... 3 Set contents: ................................................................................................................................................................... 4 Features: ............................................................................................................................................................................ 4 Defaults .............................................................................................................................................................................. 5 Light and sound signals ......................................................................................................................................... 5 Connection Instructions......................................................................................................................................... 6 Detailed programming instructions.............................................................................................................. 8 Reset the programming password...............................................................................................................10 How to use the admin tab .................................................................................................................................... 11 What is a user ID number...................................................................................................................................... 11 PIN code change (in open mode: card + PIN) ....................................................................................... 11 2 Specifications: · Warranty: 1 year · Device Type: Standalone Access Controller · Verification Type: RFID Card, Password · Operating frequency: 125 kHz · Max number of employees in the base: 1000 · Reading distance: 5 15 cm · Keyboard and keys: touch · Chip Types Read: EM · Interface: Wiegand 26 Output · Operating Voltage: DC 12V +- 12% · Working Current: 1.2A · Lock relay: DC 12V/3A · Operating temperature: 0°C ~ 45°C · Operating Humidity: 40% - 90% · Product dimensions: 12.3 x 8.4 x 2.3 cm · Package dimensions: 18.5 x 13.9 x 5.5 cm · Product weight: 200 g · Product weight with packaging: 400 g 3 Set contents: · Standalone Access Controller · Manual Features: · Can be connected directly to the electronic lock and doorbell · Verification via RFID card and password · 125 kHz operating frequency and DC12V operating voltage 4 Defaults Password Backlight Wiegand 26 Opening Mode Shared 123456 access lack password Relay Automatic Unlocking 5 seconds Output Input Safe Mode disabled Access card or password An access password includes a private access password (PIN) and a shared access password Light and sound signals Light Signal: Red and Green Description of the light signal Access Control Status Red LED flashes every 1 second slowly Standby Red LED on all the time Programming mode The green LED is on all the time Unlock Mode Green LED flashes quickly Waiting for further actions every 0.5 seconds 5 Horn: buzzer Description 1 short beep 3 short beeps 1 long beep A continuous, long beep Access Control Status Valid input Invalid input Operation success Restoring Factory Programming Passwords Connection Instructions Lp. Designation Colour 1 +12V Red 2 GND Black 3 PUSH Blue 4 OPEN Yellow 5 BELL Grey 6 BELL Violet 7 DATA0 Green 8 DATE1 White 9 NC Brown 10 COM Orange 11 YES Pink Function Power + PowerLow Output Signal Unlocking the door Bell Bell Wiegand DATA0 Wiegand DATA1 NC relay output Relay Output Com Relay output NO 6 Connection diagram Remark: If the relay has an electrical interlock, the "+" and "-" poles of the interlock must be connected in reverse. 7 Detailed programming instructions Basic functions Purpose Changing the programming password Add a user card Set a common access password Delete all users Removing a user by reading the card Operation to be performed # Programming password # 0 new programming password # # Programming password #1 card reading # # Programming password #21 new common password # # Programming password #40 0000 # # programming password 41 read card # Comments If you lose the programming password, use the default password (123456) If you want to add several cards, read them continuously There is only one common access password. Choose a method: Shared access password # Delete all cards and PINs except for a shared password To remove multiple cards, read the cards continuously Advanced features Purpose Operation to be performed Comments 8 Add a private access password (PIN) # Programming password # 22 PIN # There can be many PIN codes Add a card by entering the card number Adding multiple cards by entering the card number Add a card + PIN Deleting a user by entering a user ID number Deleting a user by entering a card number Remove a user by entering a PIN Remove all users' PIN # Programming password #23 enter card number # # programming password # 24 enter the number of the starter card number number of cards # # programming password # 3 read PIN card # # programming password #42 enter user ID # # Programming password #43 Enter card number # # programming password # 44 enter PIN number # # programming password # 45 1111 # Changing the opening # programming time password # 5 XX # Set open mode # programming password # 6 XX # Reading Setting # programming password #6 04 # The card number is 10digit or 8-digit The number of cards should be 4 digits (if you are adding twenty cards at a time, enter 0020). The card number is 10digit or 8-digit PIN consists of 3~6 digits Applicable to user PIN codes (does not include cards and PIN codes + card) XX can be 2-digit, and max. is 99. If 00 is entered, the signal output time is 0.2 s. XX can be 01 (card only) /02 (card or access password) /03 (card + PIN) The device can be used as a reader (W26 output) 9 Setting the safety function Anti-disconnection alarm setting Backlight Setting Factory reset Admin tab setting # programming XX can be 01/02 (safety password # 7 XX # function OFF/ON) and 03/04 (distance alarm OFF/ON). Note: Enabled security feature means that the system will be locked for 5 minutes if it reads an unregistered card or the wrong access password is entered 10 times # programming XX can be 01/02/03 password # 8 XX # (Off/On/Automatic) # programming Except for the password # 8 99 # programming password and admin tab # programming The first tab read is the password #91 read 1 tab added by the card read 2 cards administrator, and the second tab is the card removed by the administrator Reset the programming password To reset to the factory programming password (123456): · Turn off the power and connect 2 and 3 RST(S1) · Turn on the power, the buzzer will beep 3 long times and the green LED will flash. If you need to set an administrator card, read two blank tabs: the first as adding an administrator and the second as removing an administrator card, the second as Removing an administrator card: red LED flashes, a continuous short beep. 10 · Turn off the power, unplug container 2 and 3, and connect container 1 and 2 RST. · Turn the power back on. How to use the admin tab To add a standby user card, follow these steps: Read admin card read new card reread admin card To remove a standby user card, follow these steps: Read admin card read registered card reread admin card To remove all standby users, follow these steps: User cards can be added or removed continuously. What is a user ID number A user ID is an automatically generated 4-digit number that starts with 0001. The number increases as you add the user one by one and ignores the deletion of the user. The shared access password does not have an ID number. PIN code change (in open mode: card + PIN) After reading the card and entering the corresponding PIN code to open the door, within 5 seconds, press and hold the # button until the green LED flashes rapidly, then enter the new PIN code # new PIN code again #, a long beep indicates the successful change of the PIN code. 11 12Microsoft Word 2019