User Manual for 3nh models including: ST-700DPLUS, ST700DPLUS, 2AMRM-ST-700DPLUS, 2AMRMST700DPLUS, ST-700d Array Spectrophotometer, ST-700d, Array Spectrophotometer, Spectrophotometer

zhaoxinlei

U Manual

Shenzhen ThreeNH Technology Co.,Ltd ST-700DPLUS 2AMRM-ST-700DPLUS 2AMRMST700DPLUS st 700dplus


File Info : application/pdf, 16 Pages, 571.86KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=6330040
Array Spectrophotometer ST-700d
ST-700d is an array spectrophotometer developed by 3nh using its own spectroscopic core technology. It uses a built-in silicon photodiode array (40 sets of dual columns) sensors and an industrial-grade MCU. The powerful data processing capability ensures the stability and accuracy of the measurement data. The array spectrophotometer ST-700d can easily control the repeatability E*ab within 0.022, and the inter-instrument error E*ab within 0.2. It can be used for accurate color measurement in various occasions and conditions, and the large-size touch screen can view the measurement results more easily and convenient. The measurement data of the instrument is consistent with other competing products from Japan, the United States, and Europe.
The array spectrophotometer ST-700d is equipped with three measurement apertures : 8mm,  4mm, and 1x3mm. It has wider adaptability, accurate color measurement and stable performance. It is used in plastic electronics, paint and coatings, textile printing and dyeing, printed paper products, automobiles, medical care, cosmetics and food industries, and also are widely used in scientific research institutions and laboratories.
Features of Array Spectrophotometer ST-700d
1Silicon photodiode array (dual 40 array) sensor Larger area dual 40 array sensor, will not be saturated under strong light, sensitivity is higher under weak light, and the spectrum response range is wider, which ensures the measurement speed, accuracy, stability and consistency of the instrument. Master the core technology, developed from same platform as international standards with full compatibility.

2Adopt Full-band balanced LED light source + UV light source The array spectrophotometer ST-700d adopts 400~700nm full-band balanced LED light source and UV light source as the instrument lighting source, which has sufficient spectral distribution in the visible light range, avoiding the spectrum lack of white light LED in specific bands. It can also easily measure fluorescent materials and ensures the accuracy of the instrument measurement results.

3Grating Spectroscopic Technology Adopting plane grating spectroscopic technology, it has higher resolution and makes color measurement more accurate.
4Non-contact automatic whiteboard Calibration The array spectrophotometer ST-700d is equipped with an intelligent calibration base, which can be used for non-contact automatic whiteboard calibration. The professional-grade standard whiteboard

reflectance R%95% has good surface uniformity and high stability, and can obtain repeatable and accurate data.
5Novel fashion design based on ergonomics The large-size touch screen is more convenient to check the measurement results and color judgment. The position of the hand grip and the measurement button are carefully designed to meet different grip habits. The smooth and fine surface is derived from the high-precision appearance processing art.

6Equipped with three measuring apertures to meet the needs of more sample measurement The array spectrophotometer ST-700d is equipped with Ø8mm platform aperture, Ø4mm platform aperture, and 1x3mm aperture as standard accessory, which meets the measurement needs of most special samples.

7Camera framing positioning can clearly observe the measured area The array spectrophotometer ST-700d has a built-in camera for viewing and positioning. Through the real-time viewing of the camera, it can accurately determine whether the measured part of the object is at the center of the target, which improves the measurement efficiency and accuracy.

8Excellent inter-instrument Error and repeatability Repeatability E*ab0.022, inter-instrument error E*ab0.2, the data is stable and reliable, ensuring the consistency of measurement data of multiple devices, which can be used for color matching and accurate color transfer.

9Multiple Color Measurement Spaces and Observation Light Sources Provide CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, xy, DIN Lab99, Munsell(C/2) color spaces, and multiple observation light sources: D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30), B, U35, NBF, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, LED-C2, LED-C3, LED-C5. The light source can be customized (a total of 41 kinds of light sources, some of which are realized through the host computer/APP), which can meet the special measurement requirements under different measurement conditions.

10Using the Internationally Universal D/8 SCI/SCE Synthesis Technology Use D/8 (SCI/SCE) to measure the structure, reflect the color itself more objectively, reduce the influence of the surface texture of the object on the test result, and meet the standards: CIE No.15GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7.

11Dual Optical Path System for More Accurate Color Measurement Dual optical path system, the optical resolution in the visible light range is less than 10nm, and can measure the SCI and SCE spectra of samples at the same time.

12Support Android, IOS, Windows, WeChat Applet, Harmony OS. The array spectrophotometer ST-700d supports Android, IOS, Windows, WeChat applets, and Harmony OS, and is suitable for quality monitoring and color data management in various industries. Codify the user's color management with data, compare color differences, generate test reports, provide a variety of color space measurement data, and customize the customer's color management work.

Technical Parameters of Array Spectrophotometer ST-700d

Product Na Array Spectrophotometer ST-700d
me

D/8diffused illumination, 8-degree viewing angle

Optical Geo SCI & SCE; Include UV & Exclude UV.

metry

Conform to Standards: CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E11

64,DIN5033 Teil7

Integrating 40mm
Sphere Size

Light Source Combined Full Spectrum LED Lamp, UV Lamp.

Spectroscopi Plane Grating
c Method

Sensor

Large-area silicon photodiode array (40 pairs of dual columns)

Wavelength 400~700nm
Range

Wavelength 10nm
Interval

Reflectance 0~200%
Range

Measuring Apertures

Three Apertures: 8mm Platform + 4mm Platform + 1*3mm

Locating Me Cross Locating + Camera Locating
thod

Whiteboard Non-contact automatic whiteboard Calibration
Calibration

SCI/SCE

Measure SCI+SCE at the same time

Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,xy,DIN Lab99 Munsell(C/2)
s

Color Differ

ence Formul E*ab,E*uv,E*94,E*cmc(2:1),E*cmc(1:1),E*00, DINE99,E(Hunter)

a

Other Colori Spectrum Reflectance Rate, WI(ASTM E313-00, ASTM E313-73, CIE/ISO, AATCC, Hunte

metric Index r, TaubeBergerStensby),

YI(ASTM D1925,ASTM E313-00,ASTM E313-73)

Metamerism Index Mt

Staining Fastness, Color Fastness, Strength (dye strength, tinting strength), Opacity

8-degree Gloss, 555 IndexBlacknessMy,dM, Color Density CMYK(A,T,E,M), Tint(AST

M E313-00)MunsellSome functions are realized through the computer

Observer An 2°/10°
gle

D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4F5F6,F7(DLF),F8,F9F10(TPL5),F11(TL84),F12(TL

83/U30),B,U35,NBF,

Illuminants ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C

2,LED-C3,LED-C5, Light source can be customized(a total of 41 kinds of light sources,

some of which are realized through the host computer/APP)

Displayed D Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS

ata

/FAIL Result, Color Simulation, Color Offset

Measuring T About 1.5s
ime

Chromaticity Value: MAV/SCI, within E*ab 0.022 (after warm-up and calibration, the a

Repeatabilityverage value of measuring 30 times on the whiteboard at intervals of 5s)

Spectral reflectance: MAV/SCI, standard deviation within 0.07% (400~700nm)

Inter-instru MAV/SCI, E*ab within 0.2The average value of measuring BCRA series  12 color t

ment Error iles

Display Acc 0.01
uracy

Measureme Single measurement, average measurement (2~99 times)

nt Mode

Data Storag APP mass storage
e

Accuracy G Guarantee passing the Grade 1 metrology
uarantee

Dimension Length X Width X Height=114X70X208mm

Weight

About 435gCalibration Base not included

Battery

Lithium battery, 3.7V, 5000mAh, 8500 times measurements within 8 hours

Illuminant Li More than 1.5 million measurements in 10 years
fe Span

Display

TFT True Color 3.5inchCapacitive Touch Screen

Data Port USBBluetooth®5.0

Data Storag 500 pcs standard samples, 20,000 pcs samples (one piece of data can include SCI+SC

e

E at the same time), APP/PC mass storage

Software S Andriod, IOS, Windows, Wechat APPlet, Harmony OS.
upport

Language Simplified Chinese, Traditional Chinese, English

Operating E 0~40, 0~85%RH (no condensing), Altitude < 2000m
nvironment

Storage Envi -20~500~85%RHno condensing
ronment

Standard Ac Power adapter, USB cable, Manual, Quality Management Software (official website do

cessory

wnload), Calibration Box, Protective Cover, Wrist Strap, Measuring Apertures

Optional Ac Micro-printer, Powder Test Box.

cessory

Note

Technical parameters are for reference only, subject to actual sales.

Warning:Changes or modifications to this unit not expressly approved bythe party responsible forc

ompliance could void the user 'sauthority to operate the equipment.

NOTE:This device complies with part 15 of the FCC Rules. Operation issubject to the followingtwo

conditions: (1) This device may notcause harmful interference, and (2) this device mustaccept any

interference received, including interference that may causeundesired operation.

FCC Statement:

This equipment has been tested and found to comply with the limitsfor a Class B digital device,

pursuant to part 15 of the FCCRules.These limits are designed to provide reasonable

protectionagainst harmful interference in a residential installation. Thisequipment generates, uses a

nd can radiate radio frequency energyand, if not installedand used in accordance with heinstructio

ns, may cause harmfulinterference to radio communications. However, there isnoguarantee that int

erference will not occur in a particularinstallation. If this equipment does cause harmful interferenc

e toradio or television reception, which can be determined byturningthe equipment off and on, th

e user is encouraged to try tocorrect the interference by oneor more of the following

measures :

---Reorient or relocate the receiving antenna.

---Increase the separation between the equipment and receiver.

---Connect the equipment into an outlet on a circuit different

fromthat to which the receiver isconnected.

---Consult the dealer or an experienced radio/Ty technician forhelp.

The product is a portable device and meets the exposureassessment requirements for portable

devices.


WPS 文字