User Guide for CONTROL by WEB models including: X-410W Web Enabled Programmable Controller, X-410W, Web Enabled Programmable Controller, Enabled Programmable Controller, Programmable Controller, Controller
X-410 | Web-Enabled Programmable Controller
File Info : application/pdf, 2 Pages, 250.23KB
DocumentDocumentX-410W | Quick-Start Guide Basic Setup Steps 1. Power the module and connect via ethernet to a computer. 2. Set IP address on computer to the same network as module. (Ex: 192.168.1.50) Note: restore computer settings after setup. 3. To configure module, open web browser and enter: http://192.168.1.2/setup.html 4. In General Settings under WiFi, enter the WiFi settings. 5. Assign the module a permanent IP address or enable DHCP. 6. Restart the module for the settings to take effect. Factory Default Settings IP Address: 192.168.1.2 Subnet Mask: 255.255.255.0 Control Page Web Address: http://192.168.1.2 Control Password: (no password set) Setup Page Web Address: http://192.168.1.2/setup.html Setup Username: admin Setup Password: webrelay (all lower case) See users manual for setup instructions: www.ControlByWeb.com/support/ Rev 1.0 X-410W | Pinout Diagram Power power supply +5V 4X 4X Relays Vin+ Power Supply Input (9-28VDC) Gnd Power Supply Input (Ground) Rly1 Relay 1 Normally Open 4X 4X Rly4 Relay 4 Normally Open Com Common For All Relays In1+ Digital Input 1+ 4X 4X In4+ Digital Input 4+ Gnd Ground for Inputs & 1-Wire Sensors Data Data 5Vo +5VDC Output 1-Wire Bus Inputs Connect temperature or other 1-Wire sensor(s) 1681 West 2960 South, Nibley, UT 84321, USA