Instruction Manual for Pymeter models including: PY-20TT, Digital Temperature Controller, PY-20TT Digital Temperature Controller

转曲左右对折PY-20TT-10A-正面

Simon

Pymeter Digital Temperature Controller Dual Probe Reptile Thermostat Controlled Outlet Cooling Heating Pad Heat Mat Thermostat for Reptiles Homebrew Aquarium Greenhouse Terrarium Carboy Heater 10A 1200W

10A 1200W User Guide (PDF) Pymeter Pymeter Pymeter,Digital,Temperature,Controller,Dual,Probe,Reptile,Thermostat,Controlled,Outlet,Cooling,Heating,Pad,Heat,Mat,Thermostat,for,Reptiles,Homebrew,Aquarium,Greenhouse,Terrarium,Carboy,Heater,B08YP92RF4,B08T1TB49Q,B083Q7YRBM

Pymeter 2 in 1 Digital Temperature Controller Dual Outlet Heat Mat Thermostat Reptile Greenhouse Heater Home Brewing Freezer Cooling Heating Pad Control 16A 1920W

16A 1920W User Guide (PDF) Pymeter Pymeter Pymeter,2,in,1,Digital,Temperature,Controller,Dual,Outlet,Heat,Mat,Thermostat,Reptile,Greenhouse,Heater,Home,Brewing,Freezer,Cooling,Heating,Pad,Control,16A,1920W,B08YP92RF4,B08T1TB49Q,B083Q7YRBM

User Guide (PDF)

Pymeter Digital Temperature Controller Dual Probe Reptile Thermostat Controlled Outlet for Terrarium Heat Mat Heating Pad, Switch Cooling Fan Freezer Fridge ON & Off at Setpoints 10A 1200W : Industrial & Scientific


File Info : application/pdf, 2 Pages, 930.90KB

PDF preview unavailable. Download the PDF instead.

91XYFrfPfFL
PY-20TT

Website: www.pymeter.com Email: support@pymeter.com

3. Use for heating device



       

OUT 2

OUT 1

 

temp
(1oF, 2oF) OFF-point
heating
ON-point (1on, 2on)

High limit (target temp)
Low limit (start temp)

on off
on off
on off

off on
off on
off on
PV SV
SET SAV

1. Keys Instruction
 PV: under working mode, display sensor 1 Temperature; under setting mode, display menu code.
 SV: under working mode, display sensor 2 Temperature; under setting mode, display setting value.
 SET key: press SET key for 3 seconds to enter setting.  SAV key: during the setting process, press SAV key
to save and exit setting.  INCREASE key: under setting mode, press
INCREASE key to increase value.  DECREASE key: under setting mode, press
DECREASE key to decrease value.  Indicator 1: the lights are on when outlet 1 is turned on. Indicator 2:the lights are on when outlet 2 is turned on.  LED1-L: the light is on if outlet 1 is set for HEATING.  LED1-R: the light is on if outlet 1 is set for COOLING.  LED2-L: the light is on if outlet 2 is set for HEATING.  LED2-R: the light is on if outlet 2 is set for COOLING.

Heating Device

ON OFF ON OFF ON OFF

time

1. For heating device, turn ON at Low temp and turn OFF at High temp. MUST set ON-point Temp < (lower than) OFF-point Temp; It will NOT work properly for heating if set ON-point Temp > = OFF-point Temp. 2. After plug in, if current temp is lower than target temp (OFFpoint), outlets turn on for heating till temp reaches OFF-point. 3. After heating device is turn off, temp will auto fall down in the cold environment, outlets will not turn on until temp reaches ONpoint.

4. Use for cooling device
temp (1on, 2on) On-point cooling

High limit (start temp)

2. Setup Instruction
When the controller is power on or working, press SETkey for over 3 seconds to enter setting mode, PV window displays the first menu code "CF", while SV window displays according setting value. Press SET key to go to next menu, press INCREASE key or DECREASE key to set current parameter value. To simple setup, just need to set values for CF, 1on, 1oF, 2on, 2oF. C and F are the temp units; 1on/2on are the ONpoint temp(start/turn on temp); 1oF/2oF are the OFF-point temp(stop/turn off temp), they are also the target temps. After setup done, press SAV key to save the settings and return to normal temperature display mode. During setting, if there is no operation for 30 seconds, the system will save the settings and return to normal temperature display mode.

OFF-point (1oF, 2oF)

Low limit (target temp)

Cooling Device

ON OFF ON OFF ON OFF

time

1. For cooling device, turn ON at High temp and turn OFF at Low temp. MUST set ON-point Temp > (higher than) OFF-point Temp; It will NOT work properly for cooling if set ON-point Temp < = OFF-point Temp. 2. After plug in, if current temp is higher than target temp (OFFpoint), outlets turn on for cooling till temp reaches OFF-point. 3. After cooling device is turn off, temp will auto rise up in the hot environment, outlets will not turn on until temp reaches ON-point.

Note:
1. None controller can keep temp always at target temp, to narrow down the temp range, please set ON-point closer to OFF-point(target temp).
2. Each outlet supports Heating/Cooling mode.

5. Setup Flow Chart

8. MENU Instruction

PV SV

Current Temperature

SET x 3s Press and hold 3 seconds

CF

Centigrade or

C/F

Fahrenheit Unit

SET

1on

Outlet 1 ON

20°C/68°F Temperature

SET

1oF

Outlet 1 OFF

30°C/86°F Temperature

SET

2on

Oultet 2 ON

25°C/77°F Temperature

SET

2oF

Outlet 2 OFF

35°C/95°F Temperature

AL

Alarm Low

-40°C/-40°F Temperature

SET

AH

Alarm High

90°C/194°F Temperature

SET

d7
99°C/210°F

Alarm Temperature Difference

SET

P7
0 (min)

Power-On Delay

SET

C1
0°C/0°F

Sensor 1 Calibration

SET

C2
0°C/0°F

Sensor 2 Calibration

SET
6. Main Features

Working SAV Normally

 Designed with independentdual outlets;  Dual Relays, able to control both Heating and Cooling
devices at the same time, or control separately;
 Dual Waterproof Sensors, turn devices on and off at
desired temperatures, very easy and flexible to use;
 Celsius or Fahrenheit Read-out;  Dual LED Display, read temperature from 2 sensors;  High and Low Temperature Alarm;  Temperature Difference Alarm;  Power-on Delay, protect output devices from excessive
on/off toggling;
 Temperature Calibration;  Settings are retained even when power off.

7.Specification

Temperature Range Temperature Resolution Temperature Accuracy
Controller Dimension Input Power Output Power
Buzzer Alarm
Sensor Cable Input Power Cord

-40~99°C / -40~210°F 0.1 °C / 0.1°F ±1°C / ±1°F 210x55x40 mm
85~250VAC, 50/60Hz 85~250VAC, MAX 10A/16A
High and Low Temperature, Temperature Difference NTC Sensorx2, 2m/6.56ft 1.35m / 4.5ft

Menu Code
CF 1on 1oF 2on 2oF AL AH d7 P7 C1 C2

Function

Setting Range

Default

Centigrade/Fahrenheit

C / F

C

Outlet 1 ON Temperature

-40°C~99°C / 20°C/ -40°F~210°F 68°F

Outlet 1 OFF Temperature

-40°C~99°C / 30°C/ -40°F~210°F 86°F

Outlet 2 ON Temperature

-40°C~99°C / 25°C/ -40°F~210°F 77°F

Oultet 2 OFF Temperature

-40°C~99°C / 35°C/ -40°F~210°F 95°F

Alarm Low Temperature

-40°C~99°C/ -40°C/ -40°F~210°F -40°F

Alarm High Temperature

-40°C~99°C/ 90°C/ -40°F~210°F 194°F

Alarm Temperature Difference

1°C~99°C/ 99°C/ 1°F~210°F 210°F

Power-On Delay

0-10mins 0 (min)

Sensor 1 Calibration

-10°C~10°C/ -18°F~18°F

0°C/ 0°F

Sensor 2 Calibration

-10°C~10°C/ -18°F~18°F

0°C/ 0°F

Attention: Don't compare it to common inaccurate
thermometer or temp gun! Please Calibrate with ice-water mixture (0/32) if necessary! Remarks: Buzzer will alarm with sound "bi-bi-biii" until the temperature is back to normal range or any key is pressed; "EEE" is displayed on PV/SV window with "bi-bi-biii" alarm if sensor is fault.
Temperature Difference Alarm(d7): (Example) if set d7 to 5°C, when temperature difference between sensor 1 and sensor 2 is over 5°C, it will alarm with sound "bi-bibiii". Power-On Delay(P7): (Example) if set P7 to 1 min, outlets won't turn on until 1 min countdown since last power off. How to Calibrate Temperature? Soak the probes fully into the ice-water mixture, the actual temperature should be 0/32, if the reading temperature are not, offset(+-) the difference in Setting C1/C2, save and exit.
9. Support and Warranty
Pymeter products are provided Lifetime Warranty and Technical Support. Any question/issue, please feel free to contact us any time on www.pymeter.com or Email support@pymeter.com.

User Manual PDF

LiveChat Support



References