Haier Console Air Conditioner
The Haier Console unit offers a compact design suitable for floor or under-window installation. It features premium functionalities such as 56° Steri-Clean and integrated hOn Wi-Fi, providing high comfort levels and energy savings with its high energy rating. The unit is equipped with an R32 detector for refrigerant leak detection, ensuring peace of mind and optimal room comfort.
Key Features
Silence ?
Double Flow ?
Compact Design ?
Sleep Mode ?
56°C Steri-Clean ?
R32 Detector ⚠️
Heating Cable w/Nordic ver ❄️
Model Specifications
Model | Indoor | Outdoor | Performance Data | Indoor Unit | Outdoor Unit | Installation Data |
AF25S2SD1FA(D) | 1U25MEHFRA-1 | Output power - COOLING (nom/min-max) | Power supply: 1/220~240/50/60 | Power supply: 1/220~240/50 | Refrigerant: R32 | |
AF35S2SD1FA(D) | 1U35MEHFRA-1 | Output power - HEATING (nom/min-max) | Treated air volume: 450/400/350/300/250 m³/h | Power cable: 3 x 1,5 mm² | Liquid pipe Ø: 6,35 (1/4) mm (inch) | |
AF50S2SD1FA(D) | 1U50S2SJ2FA-2 | Absorbed power - COOLING (nom/min-max) | High sound power: 52 dB | Interconnection cable: 4 x 1,0 mm² | Gas pipe Ø: 9,52 (3/8) mm (inch) | |
Standard | 1U25S2SM1FA-2 | Absorbed power - HEATING (nom/min-max) | Sound pressure: 40/32/25/20 dB(A) | Sound power: 59 dB | Standard pipe length without refrigerant charge: 7 m | |
1U35S2SM1FA-2 | EER | 3,80 W/W | Sound pressure: 47 dB(A) | Maximum pipe length: 20 m | ||
1U50S2SJ2FA-2 | COP | 3,73 W/W | Running current cooling/heating (Max): 6,8/6,8 A | Maximum IU - OU elevation: 10 m | ||
COOLING Pdesign (35 °C) | 2,50 kW | Starting current cooling/heating (Max): 1,5/1,5 A | Refrigerant charge in the factory: 0,63 kg | |||
HEATING Pdesign (-10 °C) | 2,40 kW | Net dimensions: 800x280x553 mm | Refrigerant charge in the factory: 0,43 TCO2eq | |||
SEER | 8,00 (A++) | Packaging dimensions: 902x375x614 mm | Additional ref. charge over std length: 20 g/m | |||
SCOP | 4,20 (A+) | Net/gross weight: 27,6/30,4 kg | Operating limits - COOLING (in/out): -20~43 °C | |||
Annual Energy Consumption - COOLING | 107 kWh/a | Compressor type: Rotary inverter | Operating limits - HEATING (in/out): -20~24 °C | |||
Annual Energy Consumption - HEATING | 798 kWh/a | |||||
Indoor Unit Net dimensions (WxDxH) | 700x210x600 mm | |||||
Indoor Unit Packaging dimensions (WxDxH) | 783x303x695 mm | |||||
Indoor Unit Net/gross weight | 16,5/18,5 kg |
Technical Data Summary
Model | Indoor | Outdoor | Performance Data | Indoor Unit | Outdoor Unit | Installation Data |
AF25S2SD1FA(D) | 1U25MEHFRA-1 | Output power - COOLING (nom/min-max) | 2,50 (0,80-3,20) kW | Net dimensions (WxDxH): 800x280x553 mm | Refrigerant: R32 | |
AF35S2SD1FA(D) | 1U35MEHFRA-1 | Output power - HEATING (nom/min-max) | 3,00 (0,80-3,80) kW | Packaging dimensions (WxDxH): 902x375x614 mm | Liquid pipe Ø: 6,35 (1/4) mm (inch) | |
AF50S2SD1FA(D) | 1U50S2SJ2FA-2 | Absorbed power - COOLING (nom/min-max) | 0,65 (0,20-1,30) kW | Net/gross weight: 27,6/30,4 kg | Gas pipe Ø: 9,52 (3/8) mm (inch) | |
Standard | 1U25S2SM1FA-2 | Absorbed power - HEATING (nom/min-max) | 0,80 (0,30-1,60) kW | Compressor type: Rotary inverter | Standard pipe length without refrigerant charge: 7 m | |
1U35S2SM1FA-2 | EER | 3,80 W/W | Maximum pipe length: 20 m | |||
1U50S2SJ2FA-2 | COP | 3,73 W/W | Maximum IU - OU elevation: 10 m | |||
COOLING Pdesign (35 °C) | 2,50 kW | Refrigerant charge in the factory: 0,63 kg | ||||
HEATING Pdesign (-10 °C) | 2,40 kW | Refrigerant charge in the factory: 0,43 TCO2eq | ||||
SEER | 8,00 (A++) | Additional ref. charge over std length: 20 g/m | ||||
SCOP | 4,20 (A+) | Operating limits - COOLING (in/out): -20~43 °C | ||||
Annual Energy Consumption - COOLING | 107 kWh/a | Operating limits - HEATING (in/out): -20~24 °C | ||||
Annual Energy Consumption - HEATING | 798 kWh/a | |||||
Indoor Unit Power supply | 1/220~240/50/60 Hz | |||||
Indoor Unit Treated air volume | 450/400/350/300/250 m³/h | |||||
Indoor Unit High sound power | 52 dB | |||||
Indoor Unit Sound pressure | 40/32/25/20 dB(A) | |||||
Indoor Unit Net dimensions (WxDxH) | 700x210x600 mm | |||||
Indoor Unit Packaging dimensions (WxDxH) | 783x303x695 mm | |||||
Indoor Unit Net/gross weight | 16,5/18,5 kg | |||||
Outdoor Unit Power supply | 1/220~240/50 Hz | |||||
Outdoor Unit Power cable | 3 x 1,5 mm² | |||||
Outdoor Unit Interconnection cable | 4 x 1,0 mm² | |||||
Outdoor Unit Sound power | 59 dB | |||||
Outdoor Unit Sound pressure | 47 dB(A) | |||||
Outdoor Unit Running current cooling/heating (Max) | 6,8/6,8 A | |||||
Outdoor Unit Starting current cooling/heating (Max) | 1,5/1,5 A | |||||
Outdoor Unit Net dimensions (WxDxH) | 800x280x553 mm | |||||
Outdoor Unit Packaging dimensions (WxDxH) | 902x375x614 mm | |||||
Outdoor Unit Net/gross weight | 27,6/30,4 kg | |||||
Outdoor Unit Compressor type | Rotary inverter |
The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.