Wind Speed Sensor GS020-V2 Wireless Wind Speed Features Wind speed measurement range: 4mph to over 100 mph (6.4 to 161 km/h) Wind accuracy: +/- 3 mph maximum (typical 1 mph) Total error non-linearity and repeatability: <2% Radio range with line of sight: 4300 ft. (1300 m) Operates with one 'D' cell battery lithium 3.6V. Up to 3 years battery life for typical applications. Average of 12 months battery life for 24/24 hours use. Temperature range: -31°F to 185°F (-35°C to 85°C) Waterproof casing. Two-way communication with automatic radio power adjustment. Applications The GS020-V2 anemometer can be used in various types of applications to monitor wind speed and wind gust. It is designed to be used on moving crane and can also be used in a static condition. Figure 1, Wireless Wind Speed P/N GS020-V2 General Description The GS020-V2 is battery-powered stand-alone devices with no interconnecting cables. It utilizes a dual coil construction and generates voltage output proportional to wind speed. Its low moment of inertia and unique bearings permit very rapid response to gusts and lulls. Because of their output linearity these sensors are ideal for use with various data retrieval systems Figure 2, Wind Speed installation on crane boom Trimble Rev. 1.0 Page 1 of 6 Wind Speed Sensor GS020-V2 Table of Contents Features ................................................................................................................................................ 1 Applications ......................................................................................................................................... 1 General Description ............................................................................................................................. 1 Table of Contents ................................................................................................................................. 2 Ordering Information ........................................................................................................................... 2 Specifications ....................................................................................................................................... 3 Absolute Maximum Ratings ................................................................................................................ 3 Certifications ........................................................................................................................................ 3 Dimensions and Installation................................................................................................................. 4 Materials: ............................................................................................................................................. 5 FCC Compliance Statement (USA) ..................................................................................................... 6 Industry Canada (IC) Compliance Statement ...................................................................................... 6 Information to the User ........................................................................................................................ 6 Ordering Information Model GS020-V2 Description Wind Speed Sensor FCC (916 MHz). GS020-CSA-V2 Wind Speed Certified Class 1 Division 1, Suitable for Div 1 & Div 2. GS020-CE-V2 Wind Speed Sensor CE (868 MHz). Trimble Rev. 1.0 Page 2 of 6 Wind Speed Sensor Specifications Parameter Wind Threshold Accuracy Radio Power Radio Frequency Communication Range Battery life 40 hour/week 24/24 hours Other Weight Test Condition GS020-V2 GS020-CE-V2 GS020-V2 GS020-CE-V2 Clear line of sight `D' cell lithium `D' cell lithium GS020-V2 GS020-V2 Min Typ Max Unit 1.75 mph +/- 1 +/- 3 mph 0.0054 W 7 dBm 0.01 0.012 0.015 W 10 11 12 dBm 903 916 927 MHz 868 868 870 MHz 1300 m 4300 feet 36 Month 12 Month 6 lb 2700 g Absolute Maximum Ratings Parameter Temperature range Test Condition Operating Min Typ -35 -31 Certifications FCC/IC/CE certification FCC Part 15 Subpart C 15.247,15.205, 15.207 & 15.209 ETSI EN 300 220 (AA) EMI/C: EN 61000-4-3, EN 301 489-1 - Clause 8.2 CSA Certificate Number 80130757 CSA C22.2 No. 60079-0:19, 60079-11:14 (R2018), 61010-1-12, Update 1&2, Amd1:2018 UL 60079-0-2020, UL 60079-11-2018, UL 61010-1-2018 Class I, Division 1, Group A, B, C & D T4 Ex ia IIC T4 Ga Class I, Zone 0, AEx ia IIC T4 Ga Ambient Temperature: -20°C to 40°C. Max Unit 85 ºC +185 ºF Trimble Rev. 1.0 Page 3 of 6 Wind Speed Sensor GS020-V2 WARNING: Only use Tadiran TL-5930 3.6V or Saft LS33600 cell 3.6V text. l'avertissement: Utilisez uniquement du texte Tadiran TL-5930 3,6 V ou Saft LS33600 3,6 V. WARNING: "Potential Electrostatic Charging Hazard" See Instruction (for Wind Speed Sensor GS020-CSA-V2 only) Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of this equipment may generate an ignition-capable level of electrostatic charge. Therefore, the equipment shall not be installed in a location where the external conditions are conducive to the build-up of electrostatic charge on such surfaces. In addition, the equipment shall only be cleaned with a damp cloth. AVERTISSEMENT : "Risque potentiel de charge électrostatique" - Voir les instructions (pour le capteur de vitesse du vent GS020-CSA-V2 uniquement) Dans certaines circonstances extrêmes, les pièces non métalliques incorporées dans le boîtier de cet équipement peuvent générer un niveau de charge électrostatique capable de s'enflammer. Par conséquent, l'équipement ne doit pas être installé dans un endroit où les conditions extérieures sont propices à l'accumulation de charges électrostatiques sur ces pièces. conditions extérieures sont propices à l'accumulation de charges électrostatiques sur ces surfaces. En outre, l'équipement ne doit être nettoyé qu'à l'aide d'un chiffon humide. Dimensions and Installation Trimble Figure 3: General dimensions (not to scale), in inches [mm] Rev. 1.0 Page 4 of 6 Wind Speed Sensor GS020-V2 For optimal performance, the anemometer should be installed in a place where the wind can flow freely with no obstruction or perturbation. See Figure 2. The utilization of the GS020-V2 Anemometer is not limited to crane industry. It can also be used on any static structures. Materials: The black Lexan cups (virtually shatterproof) have thermal properties which let it resist and shed icing far more effectively than metal assemblies. Trimble Rev. 1.0 Page 5 of 6 Wind Speed Sensor PMN: GS020-V2 HVIN: MB106_M-03 FCC Compliance Statement (USA) GS020-V2 FCC ID: S9E-GS200B Compliance Statements: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including, an interference that may cause undesired operation. Caution Statements: · Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. · This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. Industry Canada (IC) Compliance Statement IC: 5817A-GS000B Compliance Statements: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1) This device may not cause interference., 2) This device must accept any interference, including interference that may cause undesired operation of the device. Déclarations de conformité: Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Caution Statements: · This equipment complies with radio frequency exposure limits set forth by Industry Cananda for an uncontrolled environment. · This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders. Déclarations de mise en garde: · Cet équipement est conforme aux limites d'exposition aux radiofréquences defines par Indstrie Canada pourun environment non contrôlé. · Cet équipement doit être installé et utilisé aven un minimum de 20 cm de distance dispositif et l'utilisateur ou des tiers. Information to the User NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ·Reorient or relocate the receiving antenna. ·Increase the separation between the equipment and receiver. ·Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ·Consult the dealer or an experienced radio/TV technician for help. Trimble Rev. 1.0 Page 6 of 6Microsoft Word for Microsoft 365