THERMO-HUNTER CS Series

Stationary-Type Non-Contact Thermometer

For installation in limited space

Key Features

Illustration depicting temperature control of iron plates in hamburger cooking machines.

Illustration showing temperature control during sprocket molding.

Image of the THERMO-HUNTER CS series digital display showing measured values.

Diagram illustrating the 2-point teaching function with a graph comparing 'Energy amount' with and without teaching.

Illustration of the optional laser pointer accessory for precise alignment.

Specifications

Parameter Low-medium-temperature models (standard) High-temperature models (heat-resistant head)
Model CS-30TAC, CS-40TAC CS-30TAC-HT, CS-40TAC-HT
Measurement range -40 to 500°C (-40 to 932°F) 0 to 1000°C (32 to 1832°F)
Field of view CS-30TAC: Ø30/500 mm (22:1)
CS-40TAC: Ø40/500 mm (15:1)
CS-30TAC-HT: Ø30/500 mm (22:1)
CS-40TAC-HT: Ø40/500 mm (15:1)
Optics Silicone lens
Sensing element/spectral response Thermopile/8 to 14 µm
Response time 150 ms/90% response
Accuracy*¹ -40 to 0°C (-40 to 32°F): ±3°C (5.4°F)
1 to 200°C (33.8 to 392°F): ±2°C (3.6°F)
201 to 500°C (393.8 to 932°F): ±1% of reading value
0 to 200°C (32 to 392°F): ±2°C (3.6°F)
201 to 1000°C (393.8 to 1832°F): ±1% of reading value
Repeatability Up to 200°C (392°F): ±1.0°C (1.8°F), 201°C (393.8°F) or more: ±0.5% of reading value
Emissivity adjustment 0.1 to 1.2
Display resolution 1°C increments
Analog output 4 to 20 mA
Output Resolution 0.5°C increments
Output Accuracy ±0.5% or ±1.0°C (1.8°F)
Update time 10 ms
Allowable load 250 Ω
Impedance 47 Ω
Control output Photo MOS FET x 2 (Transfer contact x 2)
Capacitive load 300 mA/30 VDC or less
Interface Digital output
Functions Teaching function: 2 points, Response time selection (DELAY) function: 1 (0.15 sec.) to 200 (approx. 10 sec.), Output scaling function
External input Bank function: 4 banks, Synchronous input trigger function, External trigger function, Wave trigger function
Degree of protection Sensor head: IP69K (DIN 40050 Part 9)
Amplifier: IP40 (IEC 60529)
Sensor head: IP69K (DIN 40050 Part 9)
Amplifier: IP40 (IEC 60529)
Vibration resistance 10 to 55 Hz; amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions
Supply voltage 12 to 24 VDC ±10%
Current consumption 120 mA (at max. load) / 80 mA (in Eco mode)
Ambient temperature Sensor head: 0 to 100°C (32 to 212°F)
Amplifier: 0 to 65°C (32 to 149°F)
Sensor head: 0 to 180°C (32 to 356°F)
Amplifier: 0 to 65°C (32 to 149°F)
Ambient humidity 35 to 85% RH (no condensation)
Storage temperature 0 to 70°C (32 to 158°F)
Dimensions Sensor head: M12 (ø14) x 34 mm
Amplifier: 35 x 52 x 38.5 mm
Sensor head: M12 (ø14) x 34 mm
Amplifier: 35 x 52 x 38.5 mm
Weight Sensor head: Approx. 100 g (including 3 m cable)
Amplifier: Approx. 200 g (including 2 m cable)
Sensor head: Approx. 100 g (including 3 m cable)
Amplifier: Approx. 200 g (including 2 m cable)
Material Sensor head: SUS
Amplifier: ABS
Sensor cable: PVC (low-medium-temperature models) / Silicone rubber (high-temperature models)
Sensor head: SUS
Amplifier: ABS
Sensor cable: PVC (low-medium-temperature models) / Silicone rubber (high-temperature models)

*1 The measurement accuracy in the specification is limited to the calibration conditions of our factory. Note that specifications are subject to change without prior notice for product improvement purposes.

Dimensions

Detailed dimension drawings are available for the sensor head, amplifier, and mounting bracket.

Sensor Head: Standard dimensions are M12 (ø14) x 30 mm. The cable can be cut to any length (ø4 x 3000 mm max.).

Amplifier: Dimensions are 35 x 52 x 38.5 mm.

Mounting Bracket (CS-FB12): Specific mounting dimensions are provided in detailed drawings.

Cable: Standard cable dimensions are ø6 x 2000 mm (max.).

Diagrams illustrating the field of view (spot size at distance) for CS-30TAC and CS-40TAC models, with and without a CF lens.

Detailed dimension drawings for the THERMO-HUNTER CS series sensor head, amplifier, and CS-FB12 mounting bracket.

Diagram showing the dimensions and maximum length of the sensor head cable.

Options and Accessories

Laser pointer (CS-LDP)

A laser pointer makes precise positioning easy, even with a small head, which is difficult with a conventional setup. Designed to be the same shape as the sensor head, laser pointers can be easily used during alignment. This product uses a Class 2 laser that conforms to IEC 60825-1.

Laser Pointer Specifications: Supply voltage: 3.0 VDC ±10%; Wavelength: 630-670 nm; Maximum Power: <1mW (CLASS 2); Beam Divergence: <1mrad; Optical Axis Accuracy: ±2°; Ambient Temperature: 0 to 40°C; Environmental Humidity: 35 to 85%RH (without dew condensation); Storage Temperature: -10 to 60°C; Vibration Resistance: 10 to 55Hz, 1.5 mm amplitude, 2 hours each for XYZ directions with packaging; Degree of Protection: IP40 (IEC 60529); Materials: Stainless Steel; Weight: Approx. 60 g; Applicable Regulations: RoHS Directive (2011/65/EU), China RoHS (MIIT Order No.32), FDA Regulation (21CFR 1040.10 and 1040.11); Applicable Standards: IEC 60825-1.

CF lens (CS-CF01)

Used for micro-point measurement. Note that the amount of light received from the measurement target is attenuated by 20 to 30%, requiring emissivity adjustment.

Air purge pipe (CS-AP1)

Accessory for maintaining sensor cleanliness.

Mounting bracket (CS-FB12)

Designed for secure mounting of the sensor head.

Black tape for glossy objects (HB-250)

Helps improve measurement accuracy on highly reflective surfaces.

Images of optional accessories: CS-LDP Laser pointer, CS-CF01 CF lens, CS-AP1 Air purge pipe, CS-FB12 Mounting bracket, and HB-250 Black tape for glossy objects.

PDF preview unavailable. Download the PDF instead.

optex-fa cs-vol8 catalog 2412 h Adobe InDesign 19.5 (Windows) Adobe PDF Library 17.0

Related Documents

Preview Optex CX-702/CX-702V Passive Infrared Detector Installation Guide
Comprehensive installation instructions for the Optex CX-702 and CX-702V Passive Infrared Detectors, covering features, specifications, troubleshooting, wiring, and area pattern adjustments for optimal security system integration.
Preview OPTEX OVS-02GT Quick Reference Guide: Installation, Wiring, and Setup
Comprehensive guide for the OPTEX OVS-02GT Virtual Loop 2.0 vehicle presence sensor, detailing installation, wiring, app setup, and calibration procedures for optimal performance.
Preview OPTEX OVS-02GT Virtual Loop Installation Instructions
Comprehensive installation guide for the OPTEX OVS-02GT Virtual Loop vehicle detection sensor, covering setup, configuration, and troubleshooting.
Preview OPTEX iVISION+ Wireless Video Intercom User Manual
User manual for the OPTEX iVISION+ wireless video intercom system, covering features, setup, operation, settings, troubleshooting, and FAQs. Learn how to install, use, and maintain your wireless video intercom.
Preview Optex SMDC-16 Programming Manual
A comprehensive programming manual for the Optex SMDC-16 Digital Control Communicator and SMPC-32 Personal Control. It details system configuration, zone setup, receiver options, system features, report codes, and downloading procedures.
Preview OPTEX ORT 8910 HD Remote Control: Original vs. Replacement Functionality Comparison
Detailed comparison of button functions between the original OPTEX ORT 8910 HD remote control and its replacement model, including key mappings for TV, media, and navigation.
Preview OPTEX FlipX Series FLX-A-AM/FLX-A-DAM Installation Guide
Comprehensive installation instructions for the OPTEX FlipX Series indoor detectors (models FLX-A-AM, FLX-A-DAM-X5, FLX-A-DAM-X8, FLX-A-DAM-X9). Learn how to install, configure, and test these advanced PIR and Microwave motion detectors for security systems.
Preview OPTEX Security Sensors and Systems: Comprehensive Product Catalog
Explore the full range of OPTEX advanced security sensors, including indoor and outdoor PIR detectors, visual verification systems, REDSCAN laser detectors, and REDWALL outdoor PIR detectors for comprehensive security solutions.