Specifications for Rinnai models including: Rinnai, RL75i, REU-VC2528FFUD-US, HIGH-EFFICIENCY, NON-CONDENSING, TANKLESS, WATER, HEATER

Kimberly Woods

ompact Design to Save Space - Lowes Holiday

1 Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer. * learance for servicing is 24 in. (610 mm) in front of water heater in. (mm) SPEIFIATION RL75i

High Efficiency Plus 7.5 GPM Residential Natural Gas Interior Tankless Water Heater with 21 in. Vent Kit Bundle Specification

Rinnai RL75iN-223182 766156013973 0766156013973 1005090289


File Info : application/pdf, 2 Pages, 613.98KB

PDF preview unavailable. Download the PDF instead.

db510f77-0d61-434d-b9fa-eef472d63b38
· Compact Design to Save Space · Wi-Fi Technology for Remote Monitoring, Management
and Recirculation Control. · Simple Gas Conversion · Includes Certified Isolation Valves for Potable Water
Condensate Neutralizer, ScaleCutter, Additional Controllers, Pipe Cover, EZConnectTM Cables, control·rTM Wi-Fi Module, External Recirculation Pump, Wireless Accessories, and many more.
Visit rinnai.us for a complete list of accessories.

HIGH-EFFICIENCY (NON-CONDENSING) TANKLESS WATER HEATER

Installation Type

Internal (Indoor) Residential and Commercial Applications; Certified for installation in Manufactured (Mobile) Homes

Model Number

RL75i (REU-VC2528FFUD-US)

Approved Gas Types

Natural and Propane

High Altitude Approved

Up to 10,200 ft. (3,109 m)

Water Flow Control

Water Flow Sensor, Electronic Water Control and Fixed Bypass Control

Efficiency

Ratings not certified by AHRI

UEF: 0.81 EF: 0.82

Controller

Included: MC-91-2US
Optional: MC-100V-1US (Deluxe), BC-100V-1US (Bathroom), MCC-91-2US (Hydronic and Commercial Applications), MC-195T-US (for use with Circ-Logic), control·rTM Wi-Fi Module

Certifications

AHRI, ANSI Z21.10.3, and CSA 4.3

Warranty
· Heat Exchanger: 12 years* for residential
· All Other Parts and Components: 5 Years*
· Reasonable Labor: 1 Year
* 3 years if used as a circulation water heater within a circulation loop when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated. Refer to the Tankless Water Heater Installation and Operation manual for complete warranty information.

Safety Devices
Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS), Thermal Fuse and Automatic Frost Protection

Included with Purchase

Tankless Water Heater, Color Coded Cold (Blue) and Hot (Red) Isolation Valves, Pressure Relief Valve, MC-91-2 Temperature Controller

Additional Features
· Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels

· Ultra Low NOx · Wi-Fi & Recirculation Capable · 1/2 in. (13 mm) Gas Line Compatible

C

US



SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Weight Sound Level

RL75i 14.04 in. x 22.95 in. x 9.27 in. (356.6 mm x 583 mm x 235.5 mm)
10,300
180,000 0.26 - 7.5 GPM (1.0 - 28.4 L/min)
45.6 lbs. (20.7 kg.) 47 dB

Electrical

Normal Standby Freeze Protection Max With Pump Max Without Pump

76 W 2 W 120 W 8 Amps 4 Amps

Fuse

10 Amps

Temperature (with remote)

98° - 120° F (37°C - 49°C) (factory default)

98° - 160° F (37° - 71° C) available with the MCC-91-2 controller for

hydronic applications

Temperature (without remote)

120° F (49°C) (factory default) and 140° F (60°C)

Gas Supply Pressure2

· Natural: 4 in. w.c. - 10.5 in. w.c. (2.5 mbar ­ 26.1 mbar) · Propane: 8 in. w.c. - 13.5 in. w.c. (20 mbar ­ 33.6 mbar)

Ignition System

Direct Electronic Ignition

Electronic Connections

· Appliance: AC 120 Volts, 60Hz. · Temperature Controller: DC 12 Volts (Digital)

Water Supply Pressure

· Minimum: 20 PSI (Recommended 30-80 PSI for max performance) · Maximum: 150 PSI

Controller Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

Service Connections

· Gas Supply: 3/4 in. (19 mm) NPT · Cold Water Inlet: 3/4 in. (19 mm) NPT · Hot Water Outlet: 3/4 in. (19 mm) NPT

Clearances from Combustibles

· Top: 6 in. (152 mm)

· Back: 0 in.

· Bottom/Ground: 12 in. (305 mm) · Sides: 2 in. (51 mm)

· Front: 6 in. (152 mm)*

· Vent: 0 in.

Clearances from Non-Combustibles

· Top: 2 in. (51 mm)

· Back: 0 in.

· Bottom/Ground: 12 in. (305 mm) · Sides: 1/2 in. (13 mm)

· Front: 6 in. (152 mm)*

· Vent: 0 in.

* Clearance for servicing is 24 in. (610 mm) in front of water heater

1 Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

2

Minimum activation flow The maximum gas supply

is 0.4 GPM (1.5 pressure must

L/min). not exceed

the

value

specified

by

the

manufacturer.

Water Flow GPM (L/min)

8.0 (380.03) 7.0 (276.05) 6.0 (262.70) 5.0 (159.00) 4.0 (145.10) 3.0 (131.40) 2.0 (27.60) 1.0 (13.80)
00.0.0 00

2255(13.9) 5500(27.8) 7755(41.6) 110000(55.6) 112255(69.4) 115500(83.3)
DeltDaTT­-TTeemmppereartautreurReisReise (°F)

FRONT

14.04 (356.6)

in. (mm)

22.95 (583)

SIDE

9.27 (235.5) 0.4~1.8 (10~45) Variable 5.05 (128.1)

2.67 (67.8)

BOTTOM

A
Cold Water Inlet Gas Connection

B

Hot Water C

Outlet

D

E

F G

DIMENSION Inches (mm) DIMENSION Inches (mm)

A (GAS) 1.31 (33.2)

D

4.33 (110)

A (COLD) 1.93 (49)

E

2.89 (73.3)

A (HOT) 1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)


Microsoft Publisher for Microsoft 365