1. Introduction
Congratulations on your purchase of the wireless indoor/outdoor humidity and temperature monitor. You will now be able to know the outdoor/indoor temperature and humidity while sitting inside.
2. Components
- 1 x Base Station Unit (Receiver)
- 1 x Remote Sensor (Transmitter)
- 4 x AAA Batteries
- 1 x User Manual
* Although the remote sensor is designed to be rainproof, the remote sensor must always be placed upwards so that rain won't get inside the sensor through the vent holes on the bottom of the sensor, which functions to let the remote sensor detect the environmental temperature and humidity more precisely and quickly.
3. Indoor Base Station (Receiver) Features
The base station features a clear LCD display and several buttons for operation. It can be placed on a tabletop, mounted with its magnet, or hung on a wall.
Key Features:
- LCD Display: Shows current outdoor and indoor temperature and humidity.
- Battery Compartment: Holds 2 x AAA batteries to power the unit.
- Design: Tabletop, magnet, and wall-mounted options.
Feature Callouts (Diagram Description):
The base station unit has the following labeled features:
- 1. Outdoor Remote Low Battery Icon (Indicates if the remote sensor's batteries are low)
- 2. Outdoor Temperature Display
- 3. Indoor Temperature Display
- 4. CHANNEL SYNC Button (Cycles through sensors or initiates synchronization)
- 5. °F/°C ALL-TIME/24 Button (Selects temperature units and data recording interval)
- 6. MAX/MIN CLEAR Button (Displays max/min readings or clears history)
- 7. Outdoor Humidity Display
- 8. Indoor Humidity Display
- 9. Backlight Touch Button (Activates the display backlight)
- 10. Wall Hanging Hole (For mounting the unit on a wall)
- 11. Battery Compartment (Located on the back, holds 2x AAA batteries)
- 12. Magnet (For attaching the unit to metallic surfaces)
- 13. Stand (For tabletop placement)
Specifications
Indoor Unit:
- Indoor Temperature Range: -4°F to 158°F (-20°C to 70°C)
- Indoor Humidity Range: 10% to 99%
- Temperature Display Unit: °C and °F selectable
- Temperature Resolution: 0.1°C/°F
- Humidity Resolution: 1%
4. Buttons
- CHANNEL/SYNC: Press once to display temperature and humidity readings from up to 3 outdoor remote sensors or to enter circle readings. Press and hold to enter synchronization mode.
- MAX/MIN/CLEAR: Press once to display the maximum or minimum temperature and humidity. Press and hold to clear the history data.
- °F/°C/ALL-TIME/24: Press to select the temperature display in °C or °F. When displaying max/min temperature and humidity, press this button to set the record time interval between ALL TIME or 24 hours. Note: Both ALL TIME and 24 hours represent the time since the history data was last manually cleared or a new battery was installed.
- Backlight: Touch once to turn the backlight on or off. The backlight will automatically turn off if no button is pressed for 10 seconds.
5. Temperature & Humidity Trend
The display may show trend indicators:
- ✔ indicates the temperature & humidity is in an increasing trend.
- → indicates the temperature & humidity is in a no change trend.
- ↘ indicates the temperature & humidity is in a decreasing trend.
6. Outdoor Remote Sensor (Transmitter) Features
The remote sensor is a compact, rain-proof unit designed for outdoor use.
Key Features:
- Battery Compartment: Holds 2 x AAA batteries.
- Design: Rain-proof and wall-mounted.
- Outdoor Temperature Range: -4°F to 158°F (-20°C to 70°C)
- Outdoor Humidity Range: 10% to 99%
Feature Callouts (Diagram Description):
The remote sensor unit has the following labeled features:
- 1. TX LED (Indicates transmission status)
- 2. Wall hanging hole
- 3. TX (Button/port for manual data transmission)
- 4. Channel Selector (1, 2, 3)
- 5. Battery Compartment (Holds 2x AAA batteries)
TX: Press to manually send temperature/humidity data to the receiver.
7. Buttons
- CHANNEL Selector (1,2,3): Slide the switch to set Channel 1, 2, or 3.
8. Battery Installation & Setup
Remote Sensor:
- Open the battery compartment of the remote sensor.
- Slide the channel selector switch inside the battery compartment to your desired channel. For the first remote, select any channel; for additional remotes, select any unused channel.
- Insert 2 x AAA batteries according to the polarity markings. Replace the battery compartment cover.
Base Station:
- Open the battery compartment at the back of the base station.
- Insert 2 x AAA batteries according to the polarity markings. Replace the compartment door.
NOTE: Do not mix old and new batteries. Do not mix alkaline, standard (carbon zinc), or rechargeable (nickel cadmium) batteries. For maximum performance, good quality alkaline batteries are recommended. A low battery icon will appear on the base station display if the battery power is low.
9. Synchronize Remote Sensors with the Base Station
Each time batteries are replaced or connection is lost, follow this process to pair and re-connect the base station and remote sensor:
- Position the remote sensor near the base station.
- Once batteries are installed in the base station, the RF signal icon (located on the upper center of the base station display) will flash for 3 minutes, indicating synchronization mode.
- If 3 minutes pass and the RF signal icon is no longer flashing, press and hold the CHANNEL/SYNC button on the base station for 3-4 seconds until the RF signal icon flashes again to re-enter synchronization mode.
- Install batteries in the remote sensor and wait a moment, or press the TX button inside the remote sensor battery compartment. The remote sensor's temperature/humidity will then display on the base station, indicating synchronization is complete.
- For additional remote sensors, repeat the above steps to register them (up to 3 remote sensors can be registered with one base station).
- If more than one sensor is registered, press the CHANNEL/SYNC button on the base station to select the remote channel you want displayed permanently. Press CHANNEL/SYNC until a circular arrow appears on the base station LCD display. The unit will then auto-scroll through channels every 5 seconds. Press CHANNEL until the circular arrow disappears to stop cycling.
10. Place the Base Station & Remote Sensor
- The indoor base station (receiver) should be placed in a well-ventilated indoor area, away from vents, heating or cooling elements, direct sunlight, windows, doors, or other openings.
- The remote sensor (transmitter) can be placed on a flat surface indoors or outdoors. Ensure the sensor is within the transmission distance from the base station and with minimal obstructions.
- The base station and remote sensor can both be wall mounted.
11. Maximum & Minimum Recorded Temperature & Humidity
- Press the MAX/MIN/CLEAR button once to display the highest indoor and outdoor temperatures/humidity recorded since the last reset. MAX will be shown on the display.
- Press the MAX/MIN/CLEAR button again to display the lowest indoor and outdoor temperatures/humidity recorded since the last reset. MIN will be shown on the display.
- To clear and reset the max/min records, press and hold the MAX/MIN/CLEAR button for 3 seconds when either MAX or MIN is shown on the LCD display.
- When MAX or MIN is shown on the LCD display, press the ALL-TIME/24 button once to set the data record interval between ALL TIME or 24 hours. Note: Both ALL TIME and 24 hours represent the time since the history data was last manually cleared or battery installation.
12. Purchasing Additional Remote Sensors
The model number for additional remote sensors for this unit is TX-2B. Additional sensors can be ordered directly from Amazon or ThermoPro by contacting customer service.
13. Hints & Tips
If the receiver does not connect to the transmitter, try the following:
- Press and hold the CHANNEL/SYNC button on the base station, then press the TX button on the transmitter.
- Relocate the base station and the remote unit until a connection is found.
- Signals from other electronic devices may cause interference. Place the base station and receiver away from these devices.
- The transmitter may not function properly in extreme temperatures due to battery power. Replace the batteries or wait for more moderate weather for the unit to resume proper function.
- If the base station is placed on a refrigerator or metallic object using the magnet, transmission may be shorter. Remove the station from the refrigerator/object or place it as close as possible to the remote sensor.
- If the humidity level is below 10%, the screen will display LLL. Move the sensor closer to the base station.
14. Warnings
- Do not subject the unit to excessive force, shock, dust, temperature, or humidity.
- Do not immerse the unit in water.
- Do not remove any screws.
- Do not dispose of this unit in a fire. IT MAY EXPLODE.
- Keep unit away from small children. The unit or parts of the unit might be a choking hazard.
- Never attempt to recharge batteries using any other methods.
- Dispose of the unit legally and recycle when possible.
* WARNING FOR ARTIFICIAL CARDIAC PACEMAKER USERS
Be aware that a magnet installed inside the device may impact the functionality of your artificial cardiac pacemaker. If you have a pacemaker, it is recommended to always stay at least 1 foot (0.3 meter) away from the device.
15. Specifications
- Transmission Frequency: 915MHz or 868MHz.
- Maximum Transmit Power: 8mW.
- Transmission range up to 500ft/150m (range may be shorter based on interference present).
- Indoor Temperature Range: -4°F to 158°F (-20°C to 70°C).
- Outdoor Temperature Range: -4°F to 158°F (-20°C to 70°C).
- Humidity Range: 10% to 99%.
- Temperature Tolerance: ±2.0°F (±1.1°C).
- Humidity Tolerance: ±2% from 30% to 80%; ±3% below 30% and above 80%.
- Power: 2 x AAA 1.5V for base unit and 2 x AAA 1.5V for remote sensor.
16. FCC Statement of Compliance
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING:
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
17. Declaration of Conformity
ThermoPro declares that this product complies with the basic requirements and applicable regulations of the EMC Directive 2014/30/EU and the Radio Equipment Directive 2014/53/EU. The complete declaration of conformity can be found at:
18. Disposal
Meaning of the "Dustbin" Symbol:
- Protect your environment: do not dispose of electrical equipment in domestic waste.
- Please return any electrical equipment that you will no longer use to the collection points provided for their disposal.
- This helps avoid the potential effects of incorrect disposal on the environment and human health.
- This will contribute to the recycling and other forms of reuse of electrical and electronic equipment.
- Information concerning where the equipment can be disposed of can be obtained from your local authority.
CAUTION: Batteries/rechargeable batteries must not be disposed of with household waste!
- The batteries must be removed from the appliance.
- Take spent batteries to the appropriate collection point or to a dealer.
- Your town or local authority can provide information about public collection points.
This symbol can be found on batteries/rechargeable batteries which contain hazardous substances:
- Pb = contains lead
- Cd = contains cadmium
- Hg = contains mercury
- Li = contains lithium
19. Limited One-Year Warranty
ThermoPro warrants this product to be free of defects in parts, materials, and workmanship for a period of one year from the date of purchase. Should any repairs or servicing under this warranty be required, contact Customer Service by phone or email for instructions on how to pack and ship the product to ThermoPro. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.