Instructions for VEVOR models including: Digital Depository Safe, Depository Safe, Safe

fjzzj

Installation Manual (PDF)

VEVOR Digital Depository Safe 1.7 Cubic Feet Made of Carbon Steel Electronic Code Lock Depository Safe with Deposit Slot with Two Emergency Keys Depository Box for Home Hotel Restaurant and Office

PDF preview unavailable. Download the PDF instead.

71VvJwdz7wL
Picture description

Instruction

Open the emergency key cover

Insert the emergency key,turn it counterclockwise,and turn the Knob clockwise to open the door

Push the battery cover upward, install the battery an pay attention to the posititive and negative polse

Press the escape key to set

The yellow light is on for a long

or change the password

time,input 3~8 digit password and

Press"#(B)"to conflrm

Product Functional Description:

1: Yellow light is an input digital indicator light; The green light si the door opening indicator light; a red light is an

underpressure indicator light.

2: The static current is below 10UA.

3: dynamic current is 360MA.

4: the undervoltage voltage is 4.5V (+/-0.2V)

5: normal operating voltage: 4-7V

6: The system has no password memorization function.

open the door:

When entering the correct 3-8-bit password, press B(#), the buzzer "dripping", green light 6S, electromagnet suction 6S.

Note: after entering the wrong password, the buzzer rang "three downs" and the yellow light flashed three times,

indicating that the input password was incorrect.

set the password;

(1) When setting the customer password, press the code change button, the yellow light shines twice, and the buzzer rings

twice at the same time, then enter a 3-8-bit password. After pressing B(#) to confirm, the buzzer rang twice, and the

yellow light shines twice and goes out. Represents the success of setting.

(2) When setting the main password, enter "00", then press the code change button, enter the 3-8-bit password. After

pressing B(#) to confirm, the buzzer rang twice and the yellow light flashed twice and extinguished. Represents the success

of setting.

the self-locking function of lost passwords:

1: Enter the wrong password three times in a row, the password lock will be automatically locked for 20 seconds, and the

buzzer alarm will be alarmed.

2: Enter the wrong password six times in a row, the password lock will be locked for 5 minutes, and the buzzer will ring.

Note: during the self-locking process, any key input is unresponsive.

underpressure function:

When the voltage is 4.5V (+/-0.2), the indicator light turns on and warns to replace the battery.

