Installer Friendly Series® (IFS) Three Phase Duplex

Demand Dose or Timed Dose, Float or C-Level™ Sensor Controlled System for Pump Control and System Monitoring

Product Description

The IFS duplex control panel utilizes an innovative circuit board design to control two alternating 208/240/480 VAC three phase pumps in water and sewage applications. IFS panels feature an easy-to-use touch pad on the inner door for programming and system monitoring. The alternating action equalizes pump wear. In addition, this system provides override control should either pump fail. The panel configuration can be easily converted in the field to either a timed dose or demand dose. Available with the EZconnex® float system. The panel can utilize the C-Level™ sensor for continuous level monitoring. It senses the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the panel touch pad. C-Level™ CL40 sensor operating range is 3-39.9 inches (7.6-101.3 cm). C-Level™ CL100 operating range is 3-99.5 inches (7.6-252.7 cm).

Touch Pad Features

Key Components

Note: Options, voltage, and amp range selected may change enclosure size and component layout. Schematic/Wiring Diagram and Pump Specification Label are located inside the panel.

Configuration Options

Pricing Worksheet Summary

IFS Three Phase Duplex Base Price
Alarm Package
Enclosure Rating
Pump Full Load Amps
Float Switch Application
Total Options
Enclosure Upsize
TOTAL LIST PRICE

Control Panel Model Selection

CONTROL PANEL IFS MODEL TYPE 3 6 Three Phase Duplex (includes Option 8AC as standard)
ALARM PACKAGE 3 1 Alarm Package (includes test/normal/silence switch, fuse, red light, & horn)
ENCLOSURE RATING 3 W Weatherproof, NEMA 4X (engineered thermoplastic)

Pump Full Load Amps (FLA)

208/240/480V 600V
Code FLA Range Code FLA Range
0011.0 - 1.6 FLA0051.0 - 1.6 FLA
1011.6 - 2.5 FLA1051.6 - 2.5 FLA
2012.5 - 4.0 FLA2052.5 - 4.0 FLA
3014.0 - 6.3 FLA3054.0 - 6.3 FLA
4016.0 - 10.0 FLA4056.0 - 10.0 FLA
5119.0 - 14.0 FLA5159.0 - 14.0 FLA
61113.0 - 18.0 FLA61513.0 - 18.0 FLA
62117.0 - 23.0 FLA62517.0 - 23.0 FLA
70120.0 - 25.0 FLA70520.0 - 25.0 FLA

Float Switch Application

H Floats - Pump Down (select Option 17 below)
E EZconnex® Float Switch System (select Option 34 or 35 below)
X No Floats
C C-Level™ Sensor (select Option 24 or 29). Select Option 3E and/or 4A & 4D for high water alarm and/or redundant off floats.

Note: Pump down applications only. Industry practices suggest that a secondary device, such as a float switch, be used for redundant activation of the high level alarm and pump shut off when using the C-Level™ sensor.

ENCLOSURE UPSIZE: If you selected one or more of the  options, add a one-time charge for enclosure upsize.

Available Options

OPTIONS DESCRIPTION OPTIONS DESCRIPTION
3A Alarm Flasher17CSensor Float® / Internally Weighted (per Float) - Mercury
3B Manual Alarm Reset17DSensor Float® / Externally Weighted (per Float) - Mercury
3E High Water Alarm Float (must also select Option 17) Only Available with Float Switch Application = C17GSJE MilliAmpMaster™ / Pipe Clamp (per Float) - Mechanical
4A Redundant Off (must also select Option 4D if floats are required)17HSJE MilliAmpMaster™ / Externally Weighted (per Float) - Mechanical
4D Redundant Off Float (must also select Option 4A and Option 17)17JSensor Float® / Pipe Clamp (per Float) - Mercury
5A Thermal Cutout/Heat Sensor Auto Reset (for pumps with thermal switch leads)19FFourth Float to Separate Alarm Function from Lag
5E Seal Failure Circuit and Red Indicator (2 Wire)24EC-Level™ CL40 Sensor with 4’ Vent Tube and 20’ Cord
6A Auxiliary Alarm Contact, Form C24FC-Level™ CL40 Sensor with 4’ Vent Tube and 40’ Cord
8AC Display Board - Includes: ETM Counter, Events (Cycles) Counter, Alarm Counter and Lead/Lag Selector (included as standard)24GC-Level™ CL40 Sensor with 8’ Vent Tube and 20’ Cord
10E Lockable Latch - NEMA 4X24HC-Level™ CL40 Sensor with 8’ Vent Tube and 40’ Cord
10G Lightning Arrestor24XNo C-Level™ CL40 Sensor
10K Anti-condensation Heater29AC-Level™ CL100 Sensor with 10’ Vent Tube and 20’ Cord
11C Additional NEMA 1 Remote Alarm Panel (must also select Option 6A)29BC-Level™ CL100 Sensor with 10’ Vent Tube and 40’ Cord
11D Additional NEMA 4X Remote Alarm Panel (must also select Option 6A)29XNo C-Level™ CL100 Sensor
16A 10’ Cord in Lieu of 20’ Cord (per Float)34DEZconnex® 4-Port, 25’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug
16B 15’ Cord in Lieu of 20’ Cord (per Float)34EEZconnex® 4-Port, 50’, with 10’ Floats (3) / Pipe Clamp, Sealing Plug
16C 30’ Cord in Lieu of 20’ Cord (per Float)34GEZconnex® 4-Port, 25’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug
16D 40’ Cord in Lieu of 20’ Cord (per Float)34HEZconnex® 4-Port, 50’, with 20’ Floats (3) / Pipe Clamp, Sealing Plug
35DEZconnex® 4-Port, 25’, with 10’ Floats (4) / Pipe Clamp
35EEZconnex® 4-Port, 50’, with 10’ Floats (4) / Pipe Clamp
35GEZconnex® 4-Port, 25’, with 20’ Floats (4) / Pipe Clamp
35HEZconnex® 4-Port, 50’, with 20’ Floats (4) / Pipe Clamp

Note: EZconnex® mechanically-activated, narrow angle float switches with quick release connections

Models: Installer Friendly Series Single Phase Simplex, Installer Friendly Series, Single Phase Simplex, Phase Simplex, Simplex

File Info : application/pdf, 2 Pages, 1.59MB

PDF preview unavailable. Download the PDF instead.

9500056L-IFS-3ph-dplx

References