1 apr 2022 — that can be used as a manual override to the programmed ARISTA ... installation specifications to contractors and commissioners. ... 30 lux - Daylight.
Energized for the Future As we push forward, we're eager to tackle new challenges and share innovative new technology with our customers. Here are just a few of the key areas we're focused on as we look towards the future. Scalable Smart Technology: Now more than ever, businesses and homeowners have realized the importance of flexibility. New solutions like our ARISTATM Advanced Lighting Control System take this to heart with modular components that work together but can also be easily modified as project needs change. Automated Manufacturing: By upgrading our manufacturing systems and processes, we're able to build on our high standards of quality and performance while getting new solutions to customers faster. Enhanced LED Compatibility: We've helped usher in a new standard of LED lighting control technology. Our mission is to help customers optimize energy savings and reduce maintenance needs with a suite of LED-compatible lighting controls designed specifically to match the life expectancy of LED fixtures. Diverse OEM Partnerships: Manufacturers partner with Intermatic to help bring their visions to life, with projects ranging from temperature controls to industrial equipment. Each OEM connection is an opportunity to integrate new technologies and enhance our core solutions. Local Values, Global Impact From our North American headquarters in Libertyville, Illinois to Southeast Asia and beyond, Intermatic has a presence in 35+ countries worldwide. Local values and a global perspective help our company develop meaningful solutions that are tailored to the needs of our diverse and growing customer base. 3 Inside this Catalog Our product catalog is designed to provide you with all of the necessary information you need to make a purchasing decision. Easily find the product category with color-coded sections. Product description, applications & features Product photos Additional helpful information such as dimensional drawings and wiring diagrams Advanced Lighting Controls Advanced Lighting Controls ARISTA Controllers ALC1-R 20 TITLE LISTED RATINGS Input Voltage Electronic Ballast (LED) Ballast (Fluorescent) Resistive General Use Tungsten Class 1 Class 2 Switch Type Neutral Connection Required Wiring Options Low Voltage Warranty Operating Temperature 120-277 VAC, 50/60 Hz 10 A 10 A, 120-277 VAC 120-277 VAC, 50/60Hz, 20 A 120-277 VAC, 50/60Hz, 20 A 277 VAC, 12.5 A 0 - 10 VDC 50 mA 24 VDC 145 mA SPST Yes Pigtails, Terminals 5-Year limited 32°F - 131° F (0°C - 55°C) 1 Channel 0-10V Lighting/Plug Load Controller ALC1-R LIGHTING CONTROLLER The ALC1-R lighting controller is a single-channel 0-10 V dimming controller designed to work with ARISTA Lighting Control System by Intermatic. These units can work with either 0-10 V or 1-10 V lighting fixtures, including LED's, or plug load control. Once installed, the ALC1-R unit(s) can be configured to work off of either scheduling, sensing, or a combination of both, providing maximum energy efficiency as well as occupant comfort. These units can be configured for either wireless or wired communications, and utilize Bluetooth Mesh technologies for wireless communications. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS Dimming · Indoor Lighting Control · Timing/Scheduling ON/OFF FEATURES ·Wired or wireless communications ·Provides 24VDC for wired devices ·Utilizes a secure bluetooth mesh for connectivity ·Built-in real time clock for keeping timing accuracy ·Allows for 1 wired analog Input ·Allows for 2 wired digital inputs ·Works with 0-10 V or 1-10 V luminaires ·365-Day scheduling including holidays ·Programmable blink warning alert ·Programmable light levels Model # ALC1-R Description 1 Channel 0-10 V Lighting/ Plug Load Controller Mount Type Electrical Box WIRING DIAGRAMS Scan to learn more about the ALC1-R wiring information. ADDITIONAL CONTROLLERS Intermatic's ARISTA product line is constantly expanding. Please contact an Intermatic sales representative or vistit Intermatic.com for more information and availability. Model # Description Mount Type ALC2-R* 2 Channel 0-10 V Lighting/Plug Load Controller Surface Mount ALC4-R* 4-Channel 0-10 V Lighting/Plug Load Controller Surface Mount ALC1-P* 1-Channel Phase Dimmer Electrical Box *Contact an Intermatic sales representative or visit Intermatic.com for more information and avalability 14 WALL MOUNT OCC/VAC SENSORS ALC-WM-DT-BT & ALC-WM-BT The wall mount Occupancy Vacancy Sensors designed for use with the ARISTA Lighting Controls System by Intermatic and will control lighting based upon occupancy/vacancy. If space is configured for occupancy and movement is detected, the sensor informs the ARISTA controller(s) in the space and the lights will illuminate. The light will turn OFF after the sensors deem the room vacant and the timeout period expires. If space is configured for vacancy, the ARISTA controller(s) in the space will only react when they are manually activated. The lights will turn off after the sensor deems the space vacant and the timeout period expires. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS Indoor Lighting Control · Indoor Sensing Control FEATURES ·Wired or wireless communications ·Toolless battery replacement ·Multiple mounting options ·Adjustable sensitivity settings ·Independent settings for Ultrasonic and PIR sensor technologies ·Adjustable time-out settings Model # ALC-WM-DT-BT ALC-WM-BT Description Dual Tech Wall Mount OCC/VAC Sensor PIR Wall Mount OCC/VAC Sensor Coverage Range (ft2) PIR 1200 ft², US 1000ft² 1200 ft2 IN-WALL OCC/VAC SENSORS ALC-DT-BT-WH & ALC-PI-BT-WH The In-Wall Occupancy Vacancy Sensors designed for use with the ARISTA Lighting Controls System by Intermatic and will control lighting based upon occupancy/vacancy. If the space is configured for Occupancy and movement is detected, the sensor informs the ARISTA controller(s) in the space and the lights will illuminate. The lights will turn off after the ARISTA controller(s) deem the space vacant and the timeout period completes. If the space is configured for Vacancy, the ARISTA controller(s) in the space will only react when they are manually activated. The lights will turn off after the sensor deems the space vacant and the timeout period completes. The ALC-DT-BT-WH also utilizes a built-in switch that can be used as a manual override to the programmed ARISTA controller(s). Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS Indoor Lighting Control · Indoor Sensing Control FEATURES ·120-277 VAC · Wireless communications · Eliminates 3-way and multi-way wiring · Adjustable sensitivity settings · Independent settings for Ultrasonic and PIR sensor technologies · Programmable ON/OFF button · Can be used for occupancy or vacancy applications · LED indicators for easy identification Model # ALC-DT-BT-WH ALC-PI-BT-WH Description Dual Tech In-Wall OCC/VAC Sensor PIR In-Wall OCC/VAC Sensor Coverage Range PIR 1200 ft², US 400 ft² 1200 ft2 Advanced Lighting Controls ARISTA Wall Mount & In-Wall Sensors ALC-WM-DT-BT 20 TITLE LISTED RATINGS Input Voltage 24 VDC Wiring Options Low Voltage Terminals PIR Coverage Area (sq ft) 1200 Data Transfer Options Bluetooth, Wired Warranty Operating Temperature 5-Year limited 32°F - 131°F (0°C - 55°C) ALC-DT-BT-WH ALC-PI-BT-WH 20 TITLE LISTED RATINGS Input Voltage Wiring Options Line Voltage PIR Coverage Area (sq ft) Data Transfer Options Warranty Operating Temperature 120-277 VAC, 50/60 Hz Leads 1200 Bluetooth 5-Year limited 32°F - 131°F (0°C - 55°C) 15 Advanced Lighting Controls Ratings and model charts Refer to the product index in the front of the book for a complete list by Model # Any required or additional accessories are listed in the back of each section Visit the New Intermatic.com Today! From product sell sheets and wiring diagrams to technical support and how-to content, the new Intermatic.com is your go-to resource for all things Intermatic. We've recently updated our website to showcase the many markets and applications Intermatic solutions can be used in while emphasizing the resources contractors and distributors need to make important buying decisions. Visit Intermatic.com on your computer, tablet or smartphone for a seamless browsing experience that's full of helpful content. In addition to the website's updated look and feel, we've added time-saving features, such as online chat support and a product cross reference guide, to get customers the answers they need as quickly as possible. 4 Table of Contents Advanced Lighting Controls 10-19 Solutions 10-11 ARISTATM Introduction 12-13 ARISTATM Controllers14 ARISTATM Wall-Mount & In-Wall Sensors15 ARISTATM Ceiling Mount Sensors16 ARISTATM Daylight Harvester & In-Wall Dimmer17 ARISTATM System Solution18 NightScape Introduction19 Electronic Controls 20-37 Solutions 20-21 Advanced Time Switch 22-23 Basic Plus Series 24-25 Basic Series 26-27 Electronic All Purpose Contractor Box 28-29 Panel, Surface/DIN Rail or Flush Mount, 24-Hour or 7-Day 30-31 Surface/DIN Rail Mount - 24-Hour or 7-Day32 Flush and Surface Mount - 24-Hour or 7-Day33 Enclosed Timer Module - 24-Hour 34-35 Accessories & Enclosures 36-37 Mechanical Time Switches 38-53 Solutions 38-39 24-Hour40 24-Hour with Skip-a-Day41 24-Hour with 15-Minute Interval42 24-Hour Heavy Duty43 7-Day 44-46 Panel Mount, 24-Hour or 7-Day47 Flush or Surface/DIN Rail Mount, 24-Hour48 Flush or Surface/DIN Rail Mount, 7-Day49 Electromechanical, 24-Hour or 7-Day50 Enclosed Timer Module, 24-Hour or 7-Day51 Accessories & Enclosures 52-53 Specialty Time Switches 54-59 Solutions 54-55 Percentage Cycle Timer56 Sprinkler/Irrigation Time Switches57 Electromechanical Water Heater Timers58 Water Heater Timers59 In-Wall Timers 60-73 Solutions 60-61 ASCEND® Series 62-63 7-Day Programmable Timers 64-65 24-Hour Programmable Timers 66-67 Electronic Countdown Timers 68-69 Mechanical Spring Wound Countdown Timers 70-71 In-Wall Timer Comparison Chart72 Accessories73 Plug-In Timers 74-79 Solutions 74-75 Indoor76 Outdoor 78-79 Occupancy Sensors 80-87 Solutions 80-81 Sensor Education82 Low-Voltage Ceiling Mount83 Line Voltage Ceiling Mount84 Commercial Grade In-Wall85 Self Adaptive In-Wall86 Residential In-Wall87 Photocontrols 88-99 Solutions 88-89 Product Line Overview 90-91 Locking Type Electronic92 Fixed Mount Electronic93 Locking Type Thermal94 Fixed Mount Thermal95 Button and Wall Mount Thermal / Power Tap Receptacle96 Locking Type Receptacles / Accessories97 Customizable Utility Solutions98 Hour Meters 100-105 Solutions 100-101 AC Hour Meters (Non-Reset Type)102 DC & Vibratory Hour Meters (Non-Reset Type) / AC Hour Meters (Non-Reset Type)..103 AC Hour Meters (Non-Reset Type) and Accessories104 Dimensional Drawings105 Refrigeration Temperature Controls 106-117 Solutions 106-107 24-Hour Electromechanical Defrost Timer 108-109 24-Hour and/or 7-Day Electronic Defrost Timer110 DTAV40 Wiring Diagrams/Enclosure and Bracket Dimensions111 Split Mount Refrigeration Controllers 112-113 24-Hour and/or 7-Day Electronic Defrost Timer 114-115 Controller Wiring Diagrams116 Accessories117 Surge Protection 118-133 Solutions 118-119 Surge Protection Education 120-123 Type 1 or 2 SPD for Industrial/Commercial 124-127 Light Commercial or Outdoor Surge Protection128 Type 1 or 2 SPD for Residential and Light Commercial 129-131 Type 3 SPD for Commercial and Industrial132 Type 2 SPD - Includes Telephone and Coax Line Protection133 HVAC Surge & Power Protection 134-139 Solutions 134-135 Type 1 or 2 Surge Protective Device136 HVAC Power Protection Device 138-139 Weatherproof Covers 140-153 Solutions 140-143 Low-Profile Extra-Duty Plastic Covers 142-143 Extra-Duty Die-Cast In-Use Covers 144-145 Extra-Duty Plastic In-Use Covers 146-147 Plastic In-Use Covers 148-151 Accessories152 Code Compliance153 Pool & Spa 154-185 Solutions 154-155 Mechanical Controls 156-157 Mechanical Control Centers 158-163 Load Centers 164-165 Transformers166 Junction Boxes167 Electronic Controls 168-169 Electronic Control Centers 170-172 Wireless Electronic Controls173 Wireless Add-On Components174 Valve Actuators175 Freeze Protection176 Remote Controls177 Air Switch178 Panel Mount Timers179 Surge Protection180 Specialty Controls181 Electronic Panel Mount Timers182 Portable Timers & Enclosures184 Accessories185 Enclosures and Reference 186-193 Solutions 186-187 Metal Enclosures188 Plastic Enclosures189 Specialty Mounting Options190 NOM191 Timer Selection Guide 192-193 5 Product Index Product Index Symbols 143T302A ..............................52 146--00045 ............................73 2T308A .......................36 - 37,53 146--00046 ............................73 2T511GA......................36 - 37,53 146--00047 ............................73 2T2040GA....................36 - 37,53 146MT577 ..............................73 2T2331GA .........................36,53 146MT579 ..............................73 2T2365GA ...................36-37,53 148FD5024 ............................73 2T2483GR ............................184 148FD5025 ............................73 2T2485GA...........37,53,184,188 148FD5029 ............................73 2T2500GA...................36 - 37, 53 148FD5030 ............................73 2T2502GA..................37, 53, 184 148FD5031 ............................73 2T2503A ...............................184 148FD5032 ............................73 2T2926A .....................36 - 37, 53 148FD5033 ............................73 6LV135297..............................97 148FD5034 ............................73 21T156A ...............................185 148FD5035 ............................73 21T166A ...............................185 148FD5036 ............................73 22LG116 .................................97 148FD5037 ............................73 22LG0120 ...............................97 148FD5038 ............................73 22T338GR52 ........................190 148FD5039 ............................73 22T904A ...............................185 148FD5052 ............................73 24--00041 ...............................73 148FD5054 ............................73 24--00042 ...............................73 148FD5056 ............................73 24--00046 ...............................73 148FD5058 ............................73 24--00109 ...............................73 148FD5059 ............................73 24EG5133 .............................132 148FD5060 ............................73 101--00040 .............................36 148FD5061 ............................73 107HB254 .............................185 148FD5062 ............................73 107HB255 .............................185 148FD5063 ............................73 107SB189 ...............................73 148FD5064 ............................73 107SB192 ...............................73 148FD5068 ............................73 107T73 ...................................52 148FD5070 ............................73 107T119 .................................52 148FD5071 ............................73 107TN221 ...............................52 148FD5072 ............................73 107TN222 ...............................52 148FD5073 ............................73 119--00085 ...........................185 148FD5074 ............................73 119T86A .................................52 148FD5075 ............................73 119T267 ...............................185 148FD5076 ............................73 119T340 ...............................185 148FD5077 ............................73 124--00066 ...........................185 148FD5078 ............................73 124--00139A ........................185 148FD5079 ............................73 124-00140A ..........................185 148FD5080 ............................73 124ET2574 .............................36 156EB1945A ..........................73 124ET2581 .............................36 156PB10398A ......................185 124ET2582 .............................36 156T1948A .............................52 124T905 .................................52 156T1950A .............................52 124T907A ...............................52 156T1950AD12 ......................52 124T1948 ...............................52 156T1954A .............................52 124T1952........................52,185 156T1957A .............................52 124T1953 ...............................52 156T1978A .....................52, 185 124T1954 ...............................52 156T1978AD12 ......................52 124T2058 ...............................52 156T2548A .............................52 124T2097 ...............................52 156T2978A.............................52 124T2411A......................52, 185 156T3085A.............................52 130T1042 ...............................52 156T3225A.............................52 131T68GA ..............................52 156T3230A.............................52 133RC1144 ..........................185 156T4042A...........................185 133T698A ...............................52 156T6738A...........................185 133T700A ...............................52 178GR10K-1 ...................36,109 133T701A ...............................52 178PA28A .................... 174, 185 133T773A ...............................52 178T24 .................................185 133T1115A .............................52 178T26A ..............................185 143RC140 .............................185 /IG3240RC3 .........................129 143RC151 .............................185 143T135 ...............................185 A 143T136 ...............................185 143T138 .................................52 AG1BRKT.............................128 143T145A .............................185 AG2083C3....................128,129 AG2401C3 ....................128,129 D AG2403C3 .................... 128, 129 AG3000................................136 DDFM.............................109 AG4803C3....................128,129 DDT40.............................109 AG6503C3....................128,129 BIT25.............................117 AG6503L3.....................128,129 DT200LT ........................ 79, 182 AG48013.......................128,129 DT200LT Series .............. 79, 182 AG Series .............................129 DT620...............................77, 79 ALC1-P...................................14 DT620 Series..........................77 ALC1-R .............................14, 18 DTAV40...........108,109,111,117 ALC2-R...................................14 DTAV40E2.......................110 ALC4-R...................................14 DTAV40M........................108 ALC-CMP-BT ....................16, 18 DTAV40Q.......................108 ALC-CMP-DT-BT ....................16 DT-B..............................108, 111 ALC-DH-BT........................17,18 DU5S-1.............................117 ALC-DT-BT-WH ......................15 E ALC-IWD ...........................17, 18 ALC-PI-BT-WH .......................15 E200..............................189,191 ALC-WM-BT......................15,18 E1000 Series ......................... 66 ALC-WM-DT-BT......................15 E1010...............................66 ARISTATM.................12-16,18,19 E1020..............................66 ARISTATM Nightscape..............19 EH10................................59 ASCEND® Series.....................62 EH40...............................59 ASCEND® Standard Series......63 EH Series .............................. 59 AT1-5.............................113,116 EI200................................69 AT1-5AS5E-GI................113 EI200LA................................69 AT1-5AS5U-BG....................116 EI200 Series...........................69 AT1-5AS5U-BGI ...................113 EI200W................................69 AT1-5BS2E-BGI ...................113 EI205LA................................69 AT1-5BS4E-AG ....................116 EI205W................................69 AT1-5BS6E-ALI .................... 113 EI210................................69 AT1-5BS6E-BG .................... 116 EI210LA................................69 AT1-5BS6E-BGI....................113 EI210W................................69 AT1-5BS6U-BGI ...................113 EI215W................................69 AT2-5 ............................113, 116 EI220W................................69 AT2-5BS4E-AG.................116 EI230W................................69 AT2-5BS4E-ALI..............113 EI235W................................69 AT2-5BS4E-GI..............113 EI400C................................68 AT2-5BS4U-BGI............113 EI400LAC.........................68 EI400 Series...........................68 B EI400WC.........................68 BD1-28..........................115,116 EI500................................72 BD1-28C1S5W-BI.............115 EI500C................................65 BEZ-55BLACKU.............104 EI500LAC.......................65 BEZ-55GRAYU...............104 EI500 Series...........................65 BEZ-72PU....................104 EI500WC.......................65 BIT25...........................114 EI600................................72 BIT25-B1S3E-BI............114 EI600C................................64 BIT25-B1S3U-BI.............114 EI600LAC.........................64 BIT25-B1S3W-BI.............114 EI600 Series............................64 BR1-28.........................115,116 EI600WC............................64 BR1-28B0Q3W-AI.............115 EJ600 65, 72 BR1-28C1Q5WH-B...........115 EJ600A..............................65 BR1-28C1Q5WH-BI...........115 EJ600 Series...........................65 BR1-28C1S4WH-BI............115 EK4000 Series........................93 EK4027S................................93 C EK4035S................................93 EK4036S...........................93, 94 CD1-024R......................138 EK4127S................................93 CD5.............................112 EK4135S................................93 CD5-01WHRW-I..............112 EK4136S...........................93, 94 COMBOConnect®...............167 EK4227S................................93 Contractor Box.......................28 EK4235S................................93 CT2000........................56 EK4236S...........................93, 94 EK4336S...........................93, 94 EK4436SM........................93, 94 6 Product Index Product Index EK4536.............................92, 95 ET90115CR.........................22 FF12HHC............................71 EK4537.............................92, 95 ET90115CRE.........................22 FF15MC..............................71 EK4736S .......................... 93, 94 ET90215C.........................22 FF15MH...........................71 ELC4536 .......................... 92, 95 ET90215CE.........................22 FF15MP...........................73 ET-2T2926A ........................... 36 ET90215CR.........................22 FF30MC...........................71 ET1100 .................................. 27 ET90215CRE.........................22 FF30MH...........................71 ET1100 Series ....................... 26 ET90415CR.........................22 FF30MP...........................73 ET1105C ............................... 26 ET90815CR.........................22 FF32H...........................71 ET1105CPD82 ....................... 26 ET91215CR.........................22 FF32HH............................71 ET1115C ............................... 26 ET91615CR.........................22 FF34H............................71 ET1115CPD82 ...................... 26 ETCB28253PCR..............28 FF34HH............................71 ET1125C ................................ 26 E T- N F. . . . . . . . . . . . . . . . . . . . . . . . . 3 6 FF36H............................71 ET1125CPD82 ...................... 26 ET1700 .................................. 27 F FF46H............................71 FF60MC...........................71 ET1700 Series ....................... 26 F D . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 FF60MHC............................71 ET1705C ............................... 26 F D 2 H . . . . . . . . . . . . . . . . . . . . . . . . . 7 0 FF60MP............................73 ET1725C ................................ 26 FD2HW.........................70 FF312H...........................71 ET2000 Series ...................... 24 F D 4 H . . . . . . . . . . . . . . . . . . . . . . . . . 7 0 FF312HH.............................71 ET2105C.........................24 FD4HW.........................70 FF315M............................71 ET2105CP.........................24 F D 5 M . . . . . . . . . . . . . . . . . . . . . . . . . 7 0 FF330M............................71 ET2105CR.........................24 FD5MW.........................70 FF360M............................71 ET2115C.........................24 FD6H.........................70 FF412H............................71 ET2115CP.........................24 F D 6 H H . . . . . . . . . . . . . . . . . . . . . . . . . 7 0 FF415M............................71 ET2115CR.........................24 FD6HHW.........................70 FF430M............................71 ET2125C.........................24 FD6HW.........................70 FF460M............................71 ET2125CP.........................24 FD12HC.........................70 FF Series ............................... 71 ET2125CR.........................24 FD12HH.........................70 FM1D14-24U.........................30 ET2145C.........................24 FD12HHW.........................70 FM1D14A-24.........................30 ET2145CP.........................24 FD12HWC.........................70 FM1D14A-AV.........................30 ET2145CR.........................24 FD15MAC.........................70 FM1D14-AV-U.........................30 ET2705C.........................24 FD15MC.........................70 FM1D20.........................31 ET2705CP.........................24 FD15MHW.........................70 FM1D20-24U.........................31 ET2705CR.........................24 FD15MP.........................73 FM1D20-120U ....................... 31 ET2715C.........................24 FD15MPW.........................73 FM1D20A.........................31 ET2715CP.........................24 FD15MWC.........................70 FM1D20A-24 ......................... 31 ET2715CR.........................24 FD30MAC.........................70 FM1D20A-120........................31 ET2725C.........................24 FD30MC.........................70 FM1D20A-240 ....................... 31 ET2725CP.........................24 FD30MH.........................70 FM1D20E.........................31 ET2725CR.........................24 FD30MHW.........................70 FM1D20E-24 ......................... 31 ET2745C.........................24 FD30MP.........................73 FM1D20E-120 ........................ 31 ET2745CP.........................24 FD30MPW.........................73 FM1D50A-24 ......................... 32 ET2745CR.........................24 FD30MWC.........................70 FM1D50A-120 ....................... 32 ET2805C.........................24 F D 3 2 H . . . . . . . . . . . . . . . . . . . . . . . . . 7 0 FM1D50 Series ..................... 32 ET2805CP.........................24 FD32HW.........................70 FM1QTUZ-24U ....................... 47 ET2805CR.........................24 F D 3 4 H . . . . . . . . . . . . . . . . . . . . . . . . . 7 0 FM1 Series ............................ 47 ET2815C.........................24 FD46HW.........................70 FM1STUZ-24U ....................... 47 ET2815CP.........................24 FD60MAC.........................70 FM1STUZ-120U ..................... 47 ET2815CR.........................24 FD60MC.........................70 FM1STUZ-240U ..................... 47 ET2825C.........................24 FD60MH.........................70 FM1STUZH-24U.....................47 ET2825CP.........................24 FD60MHW.........................70 FM1STUZH-120U .................. 47 ET2825CR.........................24 FD60MP.........................73 FM1STUZH-240U...................47 ET2845C.........................24 FD60MPW.........................73 FM1SWUZ-120U .................... 47 ET2845CP..........................24 FD60MWC.........................70 FM2D50-24.........................33 ET2845CR..........................24 FD415M.........................70 FM2D50-120.........................33 ET8000............................27 FD430M.........................70 FM2D50-240.........................33 ET8000 Series ........................ 26 FD430MW.........................70 FWZ55 .......................... 102, 105 ET8015C.............................26 FD460MW.........................70 FWZ72 .......................... 102, 105 ET8215C...........................26 FD Series ............................... 70 FWZ72B ............................... 102 ET8415CR ........................ 26, 27 ET9100.............................36 FF........................................72 FF2H...................................71 G ET9232............................36 ET9250............................36 ET90000............................23 ET90000 Series ..................... 22 ET90115C.........................22 ET90115CE.........................22 FF4H..................................71 G-72U..........................102 FF5M.................................71 GM40AV..........................50 FF5MH.............................71 GM40AVE..........................34 FF6H.................................71 GM40AVE-RD89 .................... 34 FF6HH................................71 GM40AV-Q..........................50 FF12HC................................71 GM40AV-QW..........................50 GM40AV Series ..................... 50 GM40AV-W..........................50 GMXFM1D20-I-24 .................. 35 GMXFM1D20-I-120...............35 GMXFM Series ...................... 35 GMXQT-O-120 ....................... 51 GMX Series ........................... 51 GMXST-I-120 ......................... 51 GMXST-I-240 ........................ 51 GMXST-O-120 ........................ 51 GMXSW-I-120 ........................ 51 GZ40 .................................... 103 GZ40AU ...................... 103, 105 H H10S13D1DG1 ..................... 126 H10S13D1DG2.....................126 H10S13Y1DG1.....................126 H10S13Y1DG2.....................126 H10S13Y2DG1.....................126 H10S13Y2DG1.....................126 H10S13Y2DG2.....................126 H10S13Y2DG2.....................126 H10S13Y3DG1.....................126 H10S13Y3DG2.....................126 H10S21S1DG1.....................126 H10S21S1DG2.....................126 H10S23D1DG1.....................126 H10S23D1DG2.....................126 H10S23Y1DG1.....................126 H10S23Y1DG2.....................126 H10S23Y2DG1.....................126 H10S23Y2DG2.....................126 H20S13D1DG1.....................127 H20S13D1DG2.....................127 H20S13Y1DG1.....................127 H20S13Y1DG2.....................127 H20S13Y2DG1.....................127 H20S13Y2DG1 ..................... 127 H20S13Y2DG2.....................127 H20S13Y2DG2.....................127 H20S13Y3DG1.....................127 H20S13Y3DG2.....................127 H20S21S1DG1.....................127 H20S21S1DG2.....................127 H20S23D1DG1.....................127 H20S23D1DG2.....................127 H20S23Y1DG1.....................127 H20S23Y1DG2.....................127 H20S23Y2DG1.....................127 H20S23Y2DG2.....................127 HB110 Series .........................76 HB112 .................................... 76 HB113 .................................... 76 HB114 .................................... 76 HB880R .................................. 79 I ICUBE ........................... 108, 109 IG20B123 ............................. 132 IG120RSM10K ..................... 130 IG120RSM20.....................130 IG1200RC3.....................129 IG1240FMP33.....................129 IG1240RC3.....................129 7 Product Index Product Index IG1300-2T-1C3.....................133 K4141C .................................. 95 LC4535LA...............................94 PB373E.........................183-184 IG1300-4T-2C3.....................133 K4200 Series ........................ 95 LC4536C ................................ 94 PB374E ................................ 184 IG1300 Series ..................... 133 K4221C .................................. 95 LC4536LAC ........................... 94 PB873MKZ....................179,183 IG2012B153 ......................... 132 K4223C .................................. 95 LCD-5S-1I ............................ 117 PB913N ........................ 179, 183 IG2200-FMK.........................130 K4236C .................................. 95 LED4536SC ...................... 92, 95 PB913N66.....................179,183 IG2200 Series ....................... 130 K4251 .................................. 95 LED4537SC ...................... 92, 95 PB913N84.....................179,183 IG2240-IMSK ................ 130 -131 K4253 .................................. 95 LGLBL ..................................97 PB914N ....................... 179, 183 IG2240-PK....................130-131 K4321C .................................. 96 IG2280-IM ............................ 131 K4400 Series ......................... 95 M PB914N66 ..................... 179, 183 PB914N84 ..................... 179, 183 IG2280-OM...................130-131 K4421M..................................95 MB-48V ................................ 104 PB Series ............................183 K4423M..................................95 MIL72AQWUZH-120...............49 PE24GVA ..............................175 IG2280-P .............................. 130 IG3240FMP33 ...................... 129 IG3240RC3 .......................... 129 IG112463 ............................. 132 IG112663 .............................. 132 IG112663BLK10 .................. 132 KM2 ....................................... 72 KM2 Series ........................... 67 KM2ST-1G ............................. 67 KM2ST-2D .............................. 67 KM2ST-2G ............................. 67 KM2ST-3G .............................. 67 MIL72ASWUZH-120 ............... 49 MIL72EQTUZ-24 .................... 48 MIL72EQTUZH-120 ................ 48 MIL72EQWUZH-120 .............. 49 MIL72ESTUZ-120 ................... 48 MIL72ESTUZ-240 ................... 48 PE24VA ......................... 171, 175 PE103 ................................... 168 PE140 .................................. 175 PE153 .................................. 169 PE153F ................................. 169 PE153P ................................ 169 IG206153 ............................. 132 KM2STU-1G ..................... 67, 72 MIL72ESTUZH-120 ................ 48 PE153PF...............................169 IG Series ......................129, 132 KMS2T-IG ............................... 67 MIL72ESWUZH-120 ............... 49 PE653 .................................. 174 IOS-CMP-DT-LV ..................... 83 KPT0170-010 ......................... 96 MIL72ESWUZH-240 ............... 49 PE653RC..............................172 IOS-CMP-DT-U ...................... 84 IOS-CMP-LV .......................... 83 IOS-CMP-U ............................ 84 KPT0170-015 ......................... 96 KPT1170-010 ......................... 96 MIL72 Series ....................48, 49 MS-101W ............................... 36 PE953 ........................... 174, 185 PE20000 .............................. 170 PE20000 Series....................170 IOS-DDR Series ..................... 86 L N PE25065RC .......................... 172 IOS-DDR-WH ......................... 86 IOS-DOV ................................. 86 IOS-DOV-DT-WH ..................... 85 IOS-DOV-IV ............................ 86 L5F13D1DG1 ........................ 124 L5F13D1DG2 ........................ 124 L5F13Y1DG1 ........................ 124 L5F13Y1DG2 ........................ 124 NightFox Pro Series ................ 99 NightFoxTM Pro Series ............ 99 Nightscape .............................. 19 PE25300 .............................. 170 PE25300F ............................ 170 PE30000 .............................. 170 PE30000 Series....................170 IOS-DOV-NL .......................... 86 IOS-DOV-NL-IV ...................... 86 L5F13Y2DG1 ........................ 124 L5F13Y2DG2 ........................ 124 O PE30000T3 .......................... 170 PE30065RC .......................... 173 IOS-DOV-NL-WH ................... 86 L5F13Y3DG1........................124 OK4500R ............................... 97 PE30065RCT3......................173 IOS-DOV Series ..................... 86 L5F13Y3DG2........................124 OK4500RJ..............................97 PE35065RC..........................173 IOS-DOV-WH .......................... 86 IOS-DPBIF-WH ....................... 87 L5F21S1DG1 ........................ 124 L5F21S1DG2 ........................ 124 P PE35300 .......................... 170 PF1000M ............... 158 -159, 160 IOS-DPBIMF-WH ................... 87 IOS-DPB Series .................... 87 IOS-DPBV-WH ........................ 87 IOS-DSIF-IV ............................ 87 IOS-DSIF-WH ......................... 87 IOS-DSIMF ............................. 87 IOS-DSIMF-IV ......................... 87 IOS-DSIMF-WH ..................... 87 IOS-DSIMF-WH ..................... 87 IOS-DSI Series ..................... 87 IOS-DSR-IV ............................ 85 IOS-DSR Series ..................... 85 IOS-DSR-WH ......................... 85 IOS-HB-U .............................. 84 IOS-PP24 ................................ 83 K K42-SW-A ............................. 97 K43-WP-KIT .......................... 97 K121 ...................................... 97 K121-30 ................................. 97 K121-GSKT ............................ 97 K121/K121-30 ........................ 97 K122 .......................................97 L5F23Y1DG1 ........................ 124 L5F23Y1DG2 ........................ 124 L5F23Y2DG1 ........................ 124 L5F23Y2DG2 ........................ 124 L10F11S1DG1 ...................... 125 L10F11S1DG2 ...................... 125 L10F13N4DG1 ..................... 125 L10F13N4DG2 ..................... 125 L10F13Y1DG1 ..................... 125 L10F13Y1DG2 ..................... 125 L10F13Y2DG1 ..................... 125 L10F13Y2DG2 ..................... 125 L10F13Y3DG1 ..................... 125 L10F13Y3DG2 ..................... 125 L10F23D1DG1 ..................... 125 L10F23D1DG2 ..................... 125 L10F23N4DG1 ..................... 125 L10F23N4DG2 ..................... 125 L10F23Y1DG1 ..................... 125 L10F23Y1DG2 ..................... 125 L10F23Y2DG1 ..................... 125 L10F23Y2DG2 ..................... 125 LC2000 Series ....................... 94 LC2100 ................................. 94 P153 Series .........................169 P1100 Series .................. 78, 182 P1101 .............................. 78, 182 P1121 .............................. 78, 182 P1131 .............................. 78, 182 P1200 Series ....................... 184 P1251P ................................. 184 P1261P ................................. 184 P1353ME........158-161, 169-170 P1403ME................158-161, 168 P4043ME................158-161, 175 P4243ME .....................158-161 P7103ME ....................... 183, 184 P40000R5 ............................. 165 P40000RT1 .......................... 165 P40000RT3 .......................... 165 PA102 ................................... 185 PA114 .......................... 167, 185 PA115 .................................. 185 PA117 .................................. 185 PA119 .................................. 185 PA122 ........................... 174, 185 PANELGUARD® H10 Series...126 PANELGUARD® H20 Series...127 PF1100 ................................ 176 PF1100 Mechanical Series ... 176 PF1102 ................................. 176 PF1102M .............................. 176 PF1112T ............................... 176 PF1200 Series .....................176 PF1202T .............................. 176 PF1222TB1 .......................... 176 PJB2175 ............................... 167 PJB4175 .............................. 167 PJB Series ...........................167 PJBX52100 .......................... 167 Pro Series Lighting Contactors . 99 Pro Series Lighting Contractors . 99 PS3000 ................. 162, 180 -181 PX50 ..................................... 166 PX50S ................................... 166 PX100 ................................... 166 PX100S ................................. 166 PX300 ................................... 166 PX300S ................................. 166 PX600 ................................... 166 PX600S ................................. 166 PX Series ............................. 166 K171H .................................... 97 LC4500 Series ...................... 94 PANELGUARD® L5 Series...124 R K4000 Series ....................... 96 LC4521C ............................... 94 PANELGUARD® L10 Series...125 K4021C .................................. 96 LC4521LA .............................. 94 PB300 Series .......................184 R8806M101C ......................... 57 K4023C .................................. 96 LC4523 .................................. 94 PB313E ........................183-184 R8806P101C..........................57 K4100 .................................. 95 LC4523LA...............................94 PB313EK..............................184 R8815P101C ......................... 57 K4121C .................................. 95 LC4527 .................................. 94 PB314E ................................ 184 R8816P101C ......................... 57 K4123C .................................. 95 LC4535 .................................. 94 PB314EK ............................. 184 RC4G ...........................178 -179 8 Product Index Product Index RC6F ................................. 179 T104PCD82..........................40 T10004RT1 ........................ 163 WP107 ................................... 152 RC117 ........................ 178 -179 T104R .................................. 40 T10004RT3 ......................... 163 WP213 ................................... 152 RC127B......................178-179 T104R3 .............................. 157 T10006R ............................. 158 WP217 ................................... 152 RC150................................179 T104R201...........................157 T10101R ............................. 158 WP1000C........................149,185 RC510 ........................ 178 -179 T105.....................................40 T10404R ............................. 158 WP1000GC ........................... 149 RC600 Series ....................180 T106M .......................... 40, 156 T10604R ................................ 158 WP1000HC.............................149 RC613 ........................ 177, 180 T106P3...............................157 T12404R ................................ 158 WP1000HGC..........................149 RC613L .............................. 180 T106R...................................40 T20000R ................................ 159 WP1010C ............................... 149 RC613R ..................... 177, 180 T170 .................................... 41 T21000R ................................ 159 WP1010HC.............................149 RC939 ........................ 177, 180 T170 Series .........................41 T21000R Series......................159 WP1010HMXD................144-145 RC2000M....................158-160 T171.....................................41 T21001R ................................ 159 WP1010MXD .......................... 144 RC2000 Series ...................178 T171CR................................41 T21004R ................................ 159 WP1020C ............................... 150 RC2163BFE ....................... 171 T172.....................................41 T30000R5 .............................. 160 WP1030C ............................... 150 RC2343PT ......................... 178 T173.....................................41 T30000R Series......................160 WP1030MXD ..........................144 RC Series ...........................179 T173CR................................41 T30004R ................................ 160 WP1050 ..................................150 T173R ................................. 41 T30401R.........................158,160 WP1100C ............................... 148 S T174 .................................... 41 T30404R ................................ 160 WP1100WC............................148 SK4500K ............................ 97 T174CR................................41 T30604R ................................ 160 WP1110C ............................... 148 SK4500KJ ........................... 97 T174R .................................. 41 T32404R ................................ 160 WP1150C ............................... 149 SN4B20P1 ......................... 117 T175 .................................... 41 T40000R4 .............................. 161 WP1220C ............................... 151 SN4B20P2-B......................117 T176 .................................... 41 T40000R Series......................161 WP1230C ............................... 151 SN4B20P3-Y......................117 T1205R ................................ 40 T40000RT3 ............................ 163 WP1250..................................151 SN4B30P1 ......................... 117 T1400 .................................. 41 T40003RT3 ............................ 163 WP1250C ............................... 151 SN4B30P2-B......................117 T1471BCR............................41 T40004R ............................ 161 WP1250MVXD........................144 SN4B30P3-Y......................117 T1471BR .............................. 41 T40004RT1 ............................ 163 WP1250MXD .......................... 144 SN4B50P1 ......................... 117 T1472BR ............................. 41 T40004RT3 ............................ 163 WP3100 ................................. 148 SN4B50P2-B......................117 T1475BR ............................. 41 T40404R ............................ 161 WP3100C ............................... 148 SN4B50P3-Y......................117 T1800Series.........................41 T40604RT3 ............................ 163 WP3103C ............................... 148 ST01 ............................... 64, 72 T1871BR .............................. 41 THE 121 161 .............................46 WP3110MXD .......................... 144 ST01A .................................. 64 T1900Series.........................42 TN111RM40 ............................ 78 WP5000BL ............................. 146 ST01 Series ......................... 64 T1905...................................42 TN311 ...................................... 77 WP5000C .............................. 146 ST700 .................................. 72 T1905E ............................... 42 TN311 Series ............................ 77 WP5000G .............................. 146 ST700W ............................... 63 STW700LA ........................... 62 T1905HD ............................. 43 T1905HDM ........................... 43 U WP5000W .............................. 146 WP5100BL ............................. 146 STW700W ...................... 62, 72 T1905HDR............................43 UWZ48............................103,105 WP5100BR.............................146 T1905P.................................42 UWZ48E ......................... 104 -105 WP5100C ....................... 146, 185 T T1906...................................42 UWZ48E-24U .........................104 WP5100G...............................146 T100M........................158-160 T1970 Series ......................... 42 T1975 ................................... 42 UWZ48V ......................... 104 - 105 WP5100W ............................... 146 WP5103C ............................... 146 T100 Series ..... 40-41, 156, 157 T1975E ................................ 42 W WP5110C ............................... 146 T101 .................................... 40 T1975EHD............................43 WP5220B ............................... 146 T101B .................................. 40 T1975EHDR ......................... 43 WG190-15D ............................ 52 WP5220BL ............................. 146 T101M ......................... 40, 156 T1975ER ............................. 42 WG430-20D ............................ 52 WP5220C ............................... 146 T101P...................................40 T1975HD ............................. 43 WG433-20D ............................ 52 WP5220G...............................146 T101P3 .............................. 157 T1975HDR ........................... 43 WG436-20 ............................... 52 WP5220W .............................. 146 T101P201 .......................... 157 T1975R ................................ 42 WG630D .................................. 52 WP5221C .............................. 146 T101PCD82 ......................... 40 T1976 .................................. 42 WG720-10D ............................ 52 WP5225C .............................. 146 T101R ................................. 40 T1976R ................................ 42 WG730-14D ............................ 52 WP5225G .............................. 146 T101R3 .............................. 157 T2000 Series.........................45 WG733-14D.............................52 WP5240C .............................. 146 T101R201 .......................... 157 T2005 .................................. 45 WG736-14................................52 WP5500C .............................. 146 T102 .................................... 40 T2006 .................................. 45 WG1570-10 ..................... 52, 185 WP6000BR.............................143 T102P .................................. 40 T7000B Series......................45 WG1570-10D .......................... 52 WP6000G .............................. 143 T102R ................................. 40 T7401B ............................... 44 WG1571-10 ............................ 52 WP6000W .............................. 143 T103 .................................... 40 T7401BC..............................44 WG1571-10D .......................... 52 WP6200G .............................. 143 T103M ......................... 40, 156 T7402B ............................... 44 WG1573-10D ................... 52, 185 WP7000BR ............................ 143 T103P .................................. 40 T7402BC..............................44 WG1574-10 ............................ 52 WP7000G .............................. 143 T103PCD82 ......................... 40 T7801B ................................ 44 WG1574-10D .......................... 52 WP7000W .............................. 143 T103R .................................. 40 T7801BC..............................44 WG1576-10D...........................52 WP7003G .............................. 143 T104 .................................... 40 T7802B ................................ 44 WG1600-11 ............................ 52 WP7200BR.............................143 T104-20 ............................... 59 T8805M101C ....................... 57 WG1603-11D .......................... 52 WP7200G .............................. 143 T104-50................................40 T8805P101C ........................ 57 WH40 ...................................... 59 WP7200W .............................. 143 T104M................................156 T8845PV...............................57 WHAVQ4..................................58 T104M201..........................156 T10000R.............................158 WHAVQ Series..........................58 T104P...................................40 T10000R Series..................158 WP17 ..................................... 152 T104P3...............................157 T10004R ............................ 158 WP101 ................................... 152 T104P201 ........................... 157 WP102 ................................... 152 9 Advanced Lighting Control Solutions Take the hassle out of commercial lighting projects with the ARISTATM Advanced Lighting Control System. Our contractor-focused solution makes it easy for installers of all technology backgrounds to integrate wireless, code-compliant lighting control in a wide range of indoor applications. Flexible Control Set lighting schedules, monitor daylight levels and reduce energy waste while still allowing for manual control in a wide range of indoor environments. Suggested applications include classrooms, retail stores, offices, restaurants, schools and more. Customizable Components A suite of modular components, including sensors, controllers and manual overrides, makes it easy to install and configure ARISTA to meet diverse project needs. Users can add or remove devices at any time without resetting the system and starting from scratch. Simple Wireless Connectivity ARISTA simplifies installations with a contractor-friendly communication protocol known as Bluetooth® 5.0 mesh wireless technology. The secure wireless technology allows contractors to complete setup without connecting to a local area network or hub. Code Compliant Design Out of the box, ARISTA meets or exceeds ASHRAE 90.1-2016, IECC 2018 and Title 24-2019. The system's modular components allow design engineers and design-build contractors to select the functionality needed within a project, then hand off specific installation specifications to contractors and commissioners. Contents ARISTATM Introduction12 ARISTATM Controllers14 ARISTATM Wall-Mount & In-Wall Sensors15 ARISTATM Ceiling Mount Sensors16 ARISTATM Daylight Harvester & In-Wall Dimmer17 ARISTATM System Solution18 NightScape Introduction19 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Advanced Lighting Controls Advanced Lighting Controls ARISTA Introduction Simple, Connected, Contractor-Friendly Introducing ARISTA, a customizable smart lighting control solution for commercial and municipal buildings. The simple wireless system empowers installers of all technology backgrounds to integrate impressive, code-compliant lighting control in a wide range of applications. ARISTA Code Compliance (Meets or Exceeds): · ASHRAE 90.1-2016 · IECC 2018 · Title 24-2019 Simple, Adaptable Components A suite of modular components makes it easy to install and configure ARISTA in a wide range of commercial applications. Bluetooth wireless communication and optional battery-powered sensors help speed up installations by reducing wiring needs. Easy Smartphone Setup Use the ARISTA app to breeze through installation and manage settings once setup is complete. Permission new users to share access and control based on occupant, facility manager or inspector needs. (Available for Apple iOS and Android devices.) Commission with Ease Quickly identify components and adjust system settings in real-time using the ARISTA app. Contractors may also view multiple sites/projects from a single smartphone to streamline work. Built-in "wink" feature helps installers identify components on the fly 12 Advanced Lighting Controls Room Controller The "brain" of the ARISTA system, the Room Controller connects to the primary load, has wired or wireless inputs, drives schedules using a real-time clock, has adjustable light level settings, all accessible through the smart phone app via Bluetooth mesh technology. Advanced Lighting Controls ARISTA Introduction In-Wall Dimmer with Manual Override In-wall controls give occupants manual control of select features, including ON/OFF, raise/lower light levels (dimming), and adjustable auto-off countdown capabilities. These units are in-field upgradeable - as new features are released, users can easily upgrade the firmware of their existing control to take advantage of the new functionality. Presence Sensors Convenient and energy efficient, Presence Sensors reduce Energy Costs by ensuring lights are only on during occupancy. Presence sensors allow for either Automatic or Manual ON operation, and feature an Automatic OFF operation. In-Wall Sensors Wall-Mount Sensors Ceiling Sensors Daylight Harvester Our Daylight Harvesting Sensors help building managers make the most of natural light while promoting occupant comfort and energy efficiency. Safe and Secure Networking ARISTA uses a secure Bluetooth® mesh protocol that allows components to communicate without the need for a traditional local area network. Every device transmission is protected by three 128-bit encrypted security keys. Each Bluetooth enabled component is its own wireless node for sending, receiving and sharing control commands through a wireless mesh network. Expandability is easy with each device passing information to the next thus expanding the reach and control throughout the network. System Diagram - Bluetooth 5.0 Mesh Network 0-10 V / 1-10 V Dimmable Lighting Fixtures Ceiling Sensors In-Wall Sensors All Sensors Room Controller Wall-Mounted Sensors Occ/Vac Sensors Daylight Harvester Daylight Sensor TM Control and Commissioning App In-Wall Dimmer 13 Advanced Lighting Controls Advanced Lighting Controls ARISTA Controllers ALC1-R 20 TITLE LISTED RATINGS Input Voltage Electronic Ballast (LED) Ballast (Fluorescent) Resistive General Use Tungsten Class 1 Class 2 Switch Type Neutral Connection Required Wiring Options Low Voltage Warranty Operating Temperature 120-277 VAC, 50/60 Hz 10 A 10 A, 120-277 VAC 120-277 VAC, 50/60Hz, 20 A 120-277 VAC, 50/60Hz, 20 A 277 VAC, 12.5 A 0 - 10 VDC 50 mA 24 VDC 145 mA SPST Yes Pigtails, Terminals 5-Year limited 32°F - 131° F (0°C - 55°C) 1 Channel 0-10V Lighting/Plug Load Controller ALC1-R LIGHTING CONTROLLER The ALC1-R lighting controller is a single-channel 0-10 V dimming controller designed to work with ARISTA Lighting Control System by Intermatic. These units can work with either 0-10 V or 1-10 V lighting fixtures, including LED's, or plug load control. Once installed, the ALC1-R unit(s) can be configured to work off of either scheduling, sensing, or a combination of both, providing maximum energy efficiency as well as occupant comfort. These units can be configured for either wireless or wired communications, and utilize Bluetooth Mesh technologies for wireless communications. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS · Dimming · Indoor Lighting Control · Timing/Scheduling ON/OFF FEATURES · Wired or wireless communications · Provides 24VDC for wired devices ·Utilizes a secure bluetooth mesh for connectivity · Built-in real time clock for keeping timing accuracy · Allows for 1 wired analog Input · Allows for 2 wired digital inputs · Works with 0-10 V or 1-10 V luminaries · 365-Day scheduling including holidays · Programmable blink warning alert · Programmable light levels Model # ALC1-R Description 1 Channel 0-10 V Lighting/ Plug Load Controller Mount Type Electrical Box WIRING DIAGRAMS Scan to learn more about the ALC1-R wiring information. ADDITIONAL CONTROLLERS Intermatic's ARISTA product line is constantly expanding. Please contact an Intermatic sales representative or visit Intermatic.com for more information and availability. Model # Description Mount Type ALC2-R* 2 Channel 0-10 V Lighting/Plug Load Controller Surface Mount ALC4-R* 4-Channel 0-10 V Lighting/Plug Load Controller Surface Mount ALC1-P* 1-Channel Phase Dimmer Electrical Box *Contact an Intermatic sales representative or visit Intermatic.com for more information and availability 14 WALL MOUNT OCC/VAC SENSORS ALC-WM-DT-BT & ALC-WM-BT The wall mount Occupancy Vacancy Sensors designed for use with the ARISTA Lighting Controls System by Intermatic and will control lighting based upon occupancy/vacancy. If space is configured for occupancy and movement is detected, the sensor informs the ARISTA controller(s) in the space and the lights will illuminate. The light will turn OFF after the sensors deem the room vacant and the timeout period expires. If space is configured for vacancy, the ARISTA controller(s) in the space will only react when they are manually activated. The lights will turn off after the sensor deems the space vacant and the timeout period expires. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS · Indoor Lighting Control · Indoor Sensing Control FEATURES · Wired or wireless communications · Toolless battery replacement · Multiple mounting options · Adjustable sensitivity settings · Independent settings for Ultrasonic and PIR sensor technologies · Adjustable time-out settings Model # ALC-WM-DT-BT ALC-WM-BT Description Dual Tech Wall Mount OCC/VAC Sensor PIR Wall Mount OCC/VAC Sensor Coverage Range (ft2) PIR 1200 ft², US 1000ft² 1200 ft2 IN-WALL OCC/VAC SENSORS ALC-DT-BT-WH & ALC-PI-BT-WH The In-Wall Occupancy Vacancy Sensors designed for use with the ARISTA Lighting Controls System by Intermatic and will control lighting based upon occupancy/vacancy. If the space is configured for Occupancy and movement is detected, the sensor informs the ARISTA controller(s) in the space and the lights will illuminate. The lights will turn off after the ARISTA controller(s) deem the space vacant and the timeout period completes. If the space is configured for Vacancy, the ARISTA controller(s) in the space will only react when they are manually activated. The lights will turn off after the sensor deems the space vacant and the timeout period completes. The ALC-DT-BT-WH also utilizes a built-in switch that can be used as a manual override to the programmed ARISTA controller(s). Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS · Indoor Lighting Control · Indoor Sensing Control FEATURES · 120-277 VAC · Wireless communications · Eliminates 3-way and multi-way wiring · Adjustable sensitivity settings · Independent settings for Ultrasonic and PIR sensor technologies · Programmable ON/OFF button · Can be used for occupancy or vacancy applications · LED indicators for easy identification Model # ALC-DT-BT-WH ALC-PI-BT-WH Description Dual Tech In-Wall OCC/VAC Sensor PIR In-Wall OCC/VAC Sensor Coverage Range PIR 1200 ft², US 400 ft² 1200 ft2 Advanced Lighting Controls ARISTA Wall Mount & In-Wall Sensors ALC-WM-DT-BT 20 TITLE LISTED RATINGS Input Voltage 24 VDC Wiring Options Low Voltage Terminals PIR Coverage Area (sq ft) 1200 Data Transfer Options Bluetooth, Wired Warranty Operating Temperature 5-Year limited 32°F - 131°F (0°C - 55°C) ALC-DT-BT-WH ALC-PI-BT-WH 20 TITLE LISTED RATINGS Input Voltage Wiring Options Line Voltage PIR Coverage Area (sq ft) Data Transfer Options Warranty Operating Temperature 120-277 VAC, 50/60 Hz Leads 1200 Bluetooth 5-Year limited 32°F - 131°F (0°C - 55°C) 15 Advanced Lighting Controls Advanced Lighting Controls Advanced Lighting Controls ARISTA Ceiling Mount Sensors ALC-CMP-DT-BT 20 TITLE LISTED RATINGS Input Voltage Wiring Options Low Voltage PIR Coverage Area (sq ft) Data Transfer Options Warranty Operating Temperature 24 VDC Terminals 1300 Bluetooth, Wired 5-Year limited 32°F - 131°F (0°C - 55°C) CEILING MOUNT OCC/VAC SENSORS ALC-CMP-DT-BT & ALC-CMP-BT The Ceiling Mount Occupancy Vacancy Sensors designed for use with the ARISTA Lighting Controls System by Intermatic and will control lighting based upon occupancy/vacancy. If space is configured for Occupancy and movement is detected, the sensor informs the ARISTA controller(s) in the space and the lights will illuminate. The lights will turn off after the ARISTA controller(s) deem the space vacant and the timeout period completes. If space is configured for Vacancy, the ARISTA controller(s) in the space will only react when they are manually activated. The lights will turn off after the sensor deems the space vacant and the timeout period completes. This sensor provides a 360° coverage pattern. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS · Indoor Lighting Control · Indoor Sensing Control FEATURES · Wired or wireless communications · Toolless battery replacement · Multiple mounting options · Adjustable sensitivity settings · Independent settings for Ultrasonic and PIR sensor technologies · Adjustable time-out settings Model # ALC-CMP-DT-BT ALC-CMP-BT Description Coverage Range Dual Tech Ceiling Mount OCC/VAC Sensor PIR 1300 ft², US 1600 ft² PIR Ceiling Mount OCC/VAC Sensor 1200 ft2 SIMPLIFY INSTALLATION WITH THE ARISTA APP Use the ARISTA app to breeze through installation and configuration of ARISTA devices. Its simple workflows make it easy for contractors to set up lighting control boundaries, create ON/OFF schedules, set dimming levels, adjust sensors, add new users and more! · Quick Installation Once ARISTA devices (e.g., sensors, controllers) are physically installed and powered on, the ARISTA app helps contractors onboard components to the wireless network and assign them to a Project. · Define Boundaries Create dynamic lighting environments by assigning ARISTA devices to a specific Area, Space and Zone within a Project. This allows users to group components based on physical location and function. · Real-time Configuration Use the app to adjust input settings (e.g., run level, fade time) and create time schedules for each ARISTA device. A helpful "blink" feature allows installers to quickly identify devices in the field and begin configuration. · Grant Access Add new Installers to a Project to assist with configuration and/or commissioning on the job site. Once initial installation is complete, pass control to stakeholders by granting Occupant access within the app. This allows occupants to make adjustments to ARISTA devices within specific parameters set during installation. 16 Advanced Lighting Controls Daylight Harvester ALC-DH-BT The ALC-DH-BT is a light sensor designed for use with the ARISTA Lighting Controls System by Intermatic. This sensor is used for daylight harvesting applications where energy conservation is essential. This sensor can be used for both open loop and closed loop applications. Secure Bluetooth® 5.0 mesh technology allows installers to quickly connect this device and configure settings via the ARISTA app without connecting to a Wi-Fi network. APPLICATIONS · Daylight Sensing · Indoor Lighting Control · Indoor Sensing Control FEATURES · Battery or 24 VDC powered · Wired or wireless communications · Toolless battery replacement · Multiple mounting options · Open or closed loop compatibility · Selectable footcandle level settings Model # ALC-DH-BT Description Daylight Harvester *Settings are selectable through the ARISTA app Light Level Ranges 0.1-30 fc; 3-300 fc; 30-3000 fc* Advanced Lighting Controls ARISTA Daylight Harvester & In-Wall Dimmer ALC-DH-BT 20 TITLE LISTED RATINGS Input Voltage Wiring Options Low Voltage Data Transfer Options Warranty Operating Temperature 3 V Battery, 24 VDC Terminals Bluetooth 5-Year limited 32°F - 131°F (0°C - 55°C) In-Wall Dimmer with Display ALC-IWD The ALC-IWD is an in-wall dimmer/switch designed for use with the ARISTA Lighting Controls System by Intermatic and will provide ON/OFF functionality as well as dimming capabilities. Due to the wireless design, these switches can be used as single-pole, 3-way, or multi-way applications. These units also feature a lockable user interface to prevent unauthorized changes from being made to the control. This product is designed for use with any ARISTA controllers by Intermatic. APPLICATIONS · Dimming · Indoor Lighting Control · Indoor Sensing Control FEATURES · Wireless communications · Eliminates 3-way and multi-way wiring · Manual On/Off and dimming operations · Easy to follow display · Selectable back-lit display settings · Firmware allows users to update device, install new features · Single-pole or Multi-pole applications · Dim from multiple locations · Easy wiring · Lockable to prevent unauthorized changes Model # Description Switch Type ALC-IWD In-Wall Dimmer with Display SPST; 3-Way; Multi-Way ALC-IWD 20 TITLE LISTED RATINGS Input Voltage Wiring Options Line Voltage Data Transfer Options Warranty Operating Temperature 120-277 VAC, 60 Hz Pigtails Bluetooth 5-Year limited 32°F - 131°F (0°C - 55°C) 17 Advanced Lighting Controls Advanced Lighting Controls ARISTA System Solutions ARISTA System Solutions Improve occupant comfort and boost energy efficiency with the ARISTA Lighting Control System. The customizable smart system helps building owners create dynamic, code-compliant indoor environments that optimize natural light and support business needs. Check out a few system solution below. Private Office or Lobby with Dimming System Set Up: · ALC1-R (1) · ALC-CMP-BT (1) · ALC-IWD (1) Open Office with Dimming System Set Up: · ALC1-R (2) · ALC-CMP-BT (6) · ALC-IWD (2) Private Office or Lobby with Dimming and Daylight Harvesting System Set Up: · ALC1-R (1) · ALC-CMP-BT (1) · ALC-IWD (1) · ALC-DH-BT (1) 18 Break Room with Dimming System Set Up: · ALC1-R (1) · ALC-IWD (1) · ALC-WM-BT (1) Advanced Lighting Controls NightScape Advanced Lighting Controls Simple. Scalable. Wireless. Bring comfort and safety to outdoor spaces with the ARISTATM Nightscape Advanced Lighting Control System. The customizable system combines locking-type controls and smart presence sensors with Bluetooth mesh technology to create dynamic lighting environments that are occupant-friendly and code compliant. This is done all without a gateway or central control unit. Easy Setup Use the ARISTA Nightscape mobile app to configure sensors and controllers, adjust lighting schedules and monitor performance on the go. Robust Control Tailor ON/OFF, sensor presence overrides and part-night dimming schedules for different areas and occupant needs in large outdoor environments. Applications: · Commercial buildings · Parking lots · Schools · Parks Contact your local Intermatic representative to be the first to demo the new ARISTA Nightscape Lighting Control System. Available soon! Intermatic.com/ARISTA Example Application: U-Shaped parking lot with a roundabout outdoor area at a primary school. 19 Electronic Controls Electronic Controls Solutions Take command of complex lighting and load schedules with our robust electronic controls. Flexible 24-hour, 7-day, 365-day and dusk-to-dawn scheduling options make these solutions an excellent fit for office buildings, retail stores, schools and more. Indoor Lighting Control Boost energy efficiency and promote occupant comfort with versatile indoor lighting controls. These solutions allow users to create dynamic ON/OFF lighting schedules as well as control lights based on daily activity (Occ/Vac). Timing/Scheduling ON/OFF Take the guesswork out of daily lighting schedules with simple, reliable time scheduling controls. These solutions allow users to set daily or weekly ON/OFF schedules for a range of applications, including lighting, ventilation, pump controls and more. Outdoor Lighting Control Promote safety and comfort by illuminating outdoor spaces with energy-saving Astronomic timer controls and dusk-to-dawn photocontrols. Industrial Cycling Controls Manage ON/OFF and maintenance schedules of 3-phase motor loads with our robust electronic controls. Select solutions allow users to create monthly start-up schedules to support the long-term performance of machinery and industrial equipment. 20 Electronic Controls Contents Advanced Time Switch22 Basic Plus Series24 Basic Series26 Electronic All Purpose Contractor Box28 Panel, Surface/DIN Rail Mount - 24-Hour or 7-Day30 Panel, Surface/DIN Rail or Flush Mount 24-Hour or 7-Day31 Surface/DIN Rail Mount - 24-Hour or 7-Day32 Flush and Surface Mount - 24-Hour or 7-Day33 Enclosed Timer Module - 24-Hour34 Accessories & Enclosures36 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Electronic Controls Electronic Controls Advanced Time Switches ET91615CR ET90215CRE ET90115C Load Type Input Voltage General Purpose Ballast (Fluorescent) Electronic Ballast (LED) NO (Normally Open) NC (Normally Closed) 120-277 VAC, 50/60 Hz 12-240 VAC, 50/60 Hz 30 A, 12-240 VAC, 50/60 Hz 10 A, 12-240 VAC, 50/60 Hz 20 A, 120-277 VAC, 50/60 Hz 3 A, 120-277 VAC, 50/60 Hz 8 A, 120-277 VAC, 50/60 Hz Restive (Heater) Tungsten (Incandescent) Pilot Duty Motor 20 A, 28 VDC; 30 A, 12-240 VAC, 50/60 Hz 5 A, 12-120 VAC, 50/60 Hz 470 VA, 120-240 VAC, 50/60 Hz 1 HP, 120 VAC, 50/60 Hz; 2 HP, 240 VAC, 50/60 Hz 10 A, 28 VDC; 10 A, 120-240 VAC, 50/60 Hz 275 VA, 120-240 VAC, 50/60 Hz 1/4 HP, 120 VAC, 50/60 Hz; 1/2 HP, 240 VAC, 50/60 Hz RATINGS 20 TITLE LISTED Wire Size Min ON/OFF Times Max ON/OFF Times Warranty Operating Temperature #6 AWG 1 Sec 365 days 3-Year limited -40°F - 104°F (-40°C - 40°C) ET90000 Series 365-DAY ASTRONOMIC TIME SWITCHES The ET90000 Series combines powerful and intuitive scheduling with truly maintenance-free convenience. The PC App and Mobile App provide real-time remote control, and the USB connection and Ethernet capabilities enable in-field updates. APPLICATIONS · Indoor Lighting Control · Outdoor Lighting Control · Timing/Scheduling ON/OFF · Machinery & Pump Controls FEATURES · Automatic input voltage selection from 120 to 277 VAC, 50/60 Hz · Over 2,000 events plus holiday schedules ·Advanced scheduling including relative events, such as fourth Thursday of November or first week of year · 30 A rated contacts · 100-hour supercapacitor eliminates the need for batteries ·USB connection for uploading, downloading and transferring programs · Easy-to-follow on-screen menus for programming to-the-minute accuracy · Non-volatile memory protects programming indefinitely · Firmware can be upgraded in-field via USB or Ethernet ·Internally expandable, in 4-circuit increments, up to 16-circuits for 4, 8, and 12-circuit models · PC App for easy scheduling or control, either remotely or through USB flash drive · Mobile app for real time status and overrides Model # Circuits Enclosure Ethernet ET90115C 1 Indoor type 1 metal Ethernet Optional/USB ET90115CE 1 Indoor type 1 metal Ethernet Included/USB ET90115CR 1 Outdoor type 3R metal Ethernet Optional/USB ET90115CRE 1 Outdoor type 3R metal Ethernet Included/USB ET90215C 2 Indoor type 1 metal Ethernet Optional/USB ET90215CE 2 Indoor type 1 metal Ethernet Included/USB ET90215CR 2 Outdoor type 3R metal Ethernet Optional/USB ET90215CRE 2 Outdoor type 3R metal Ethernet Included/USB ET90415CR 4 Outdoor type 3R metal Ethernet Included/USB ET90815CR 8 Outdoor type 3R metal Ethernet Included/USB ET91215CR 12 Outdoor type 3R metal Ethernet Included/USB ET91615CR 16 Outdoor type 3R metal Ethernet Included/USB Note: The electronic mechanism snaps into the standard Intermatic enclosure for easy upgrading of mechanical mechanisms, if desired. For outdoor rated metal enclosures contact Intermatic. For accessories see page 34 22 VAC, n. TIMER POWER NEUTRAL LIGHTING red NEUTRAL L1 L2 / N NC for LOAD POWER WIRING DIAGRAMS HOT / LINE LIGHTING NO n. COM red NC NEUTRAL BELL for ging LOAD POWER HONTE/ULTINRAE L NCO s may thin ngs for LOAD POWER HOT / LINE CNOOM BELL COM ging s may thin nitghstfhoer h OR on to NC Typical bell, buzzer, or ringing NinsEtaUllaTtiRonA. LMultiple loPaHdsOmTaOy bCeOwNireTdRcoOncLurrently, within theLmOaAxDimPumOWouEtpRutOraUtinTgDsOfoOr RtheLcIGircHuTit.ING NO HOT / LINE NEUTRAL NCOCM mproved during ihthe tahreea uhchORas a storm. on to LOAD POWER OUTDHOOOTR/ LLIIGNHETING NEUTRAL PHOTOCONTROL NO COM NC mproved during LOAD POWER HOT / LINE NO he area COM uch as a storm. e any VAC, Typical installation for photocontrol in parallel with time switch contacts. Either the time switch OR the photocontrol muHsOt bTe/OLNINtoEpower the load. Ideal wilTl aIMctiEvaRtePaOt tWheEsRcheduledNtEimUeTs,RaAt Lnight, or during low-light cfoornidmitpiornosvesducshafaestyL.aL1sotaodrms . L2 / N LIGHTING n. red NC NEUTRAL for LOAD POWER HOT / LINE NO Electronic Controls NC COM NO COM ENCLOSURE DIMENSIONS NC NO Type 1, 1-2 Circuit 277 VAC 277 VAC ELL21lectronic Controls LNA3EUdTRvALanCcLOeSEd TCimOM e SOwPENitchOeUsTDOOR LIG CONTACTOR L1 L2 L3 NEUTRAL HOT / LINE NEUTRAL LOAD NC INDOOR LIGHTING 5.7" 6.7" 144 mm 169 mm COM NO COM NC NO 2.5" 64 mm NC SWITCH HOT / LINE INDOOR LIGHTING 7.8" 198 mm NEUTRAL INDOOR LIGHHTIONTG / LINE LOAD NEUTRAL LOAD POWER INDOOR LIGHTING SWITCINHDOOR LIGHTIN1G258.1m"m 3.0" 76 mm COM CONDUIT KNOCKOUT SIZES SIZCESOM QTY DUAL ¾" &N½O" 5 INDOOR LIGHTING NO Type 3R, 1-2 CircuitNC INDOOR LIGHTING HOT / LINE HOT / LINE NEUTRAL NEUTRAL LOAD POWER LOAD POWER NC INDOOR LIGHTING COM INDOOR LIGHTING HOT / LINE INDOOR LIGHTING NO NEUTRAL LOAD POWER 8.6" 219 mm NC INDOOR LIGHTINHGOT / LINE 9.6" 243 mm NEUTRAL INDOOR LIGHTING LOAD POWER 3.3" 83 mm COM CONDUIT KNOCKOUT SIZES NO SIZES QTY DUAL ¾" & ½" 5 NC Type 3R, 4-16 Circuit 5.0" 127 mm COM 277 VAC L1 L2 L3 NEUTRAL 5.7" 145 mm CLOSE COM CONTACTOR 3.6" 91 mm OUTDOOR LIG OPEN HOT / LINE ging s may thin ngs for COM Typical output lighting installation. Multiple ratings for the circuit. loads may be wirBedELcoLncurrently, within the maximum NC NEUTRAL LOAD POWER NO HOT / LINE COM 18.5" 470 mm 2.5" 64 mm NO NC SWITCH COM NEUTRAL INDOOR LIGHTING 17.9" 454 mm LOAD INDOOR LIGHTING HOT / LINE 12.7" 322 mm 5.4" 138 mm ith the h OR on to mproved during he area uch as a storm. OUTDOOR LIGHTING LOAD POWER NEUTRAL HOT / LINE PHOTOCONTROL CONDUIT KNOCKOUNTOSIZES SIZES QTY DUAL 1" & ¾" 6 DUAL ¾" & ½" NC 8 NC COM NO NO COMET90000 PC APP NC INDOOR LIGHTING NEUTRAL LOAD POWER INDOOR LIGHTING HOT / LINE INDOOR LIGHTING NEUTRAL LOAD POWER INDOOR LIGHTING The ET90000 PC App enables real-time remote control of each ET90000 device from the convenience of your laptop. It's a great tool for creating schedules before, during, or after installation. Plus, with the PC App you can control circuits, perform firmware updates, or download events, zones, and holidays from wherever you are working. The ET90000 PC App is available at Intermatic.com. 23 Electronic Controls Electronic Controls Basic Plus Series ET2105C ET2705C ET2000 Series BASIC+ ELECTRONIC TIME SWITCHES The ET2000 Series offers an easy-to-use interface, while still allowing to-the-minute scheduling capabilities for nearly any application. This series provides 50 holiday blocks with independent scheduling to ensure the loads are always in the proper ON/OFF state. This series also includes 96 ON/OFF events for even the most demanding schedules. The scheduling capabilities, configurable outputs, and a 100-hour backup without the need of batteries, make this series ideal for nearly any application. APPLICATIONS · Outdoor Lighting Control · Timing/Scheduling ON/OFF · Machinery & Pump Controls FEATURES · 100-hour supercapacitor eliminates the need for batteries · Up to 96 set points or events · Up to 50 holiday blocks with schedule capabilities · Automatic input voltage selection from 120 to 277 VAC, 60 Hz · Additional mode of operation turns the ON/OFF buttons into 2-hour overrides ·C onfigurable outputs allow the control of various voltages and applications · Relays incorporate zero-crossing technology to extend the life of the control · Non-volatile EEPROM memory protects programming indefinitely · LED compatible · USB port makes transferring and saving of schedules easy · 2-year limited warranty ET2725CP ET2845CR 24-HOUR SCHEDULE Model # Enclosure 1-Circuit SPST Switch ET2105C Indoor type 1 metal ET2105CP Indoor/outdoor type 3R plastic with see-through door ET2105CR Outdoor type 3R metal 1-Circuit SPDT Switch ET2115C Indoor type 1 metal ET2115CP Indoor/outdoor type 3R plastic with see-through door ET2115CR Outdoor type 3R metal 2-Circuit 2xSPST, 1xDPST or Pulse Switch ET2125C Indoor type 1 metal ET2125CP Indoor/outdoor type 3R plastic with see-through door ET2125CR Outdoor type 3R metal 4-Circuit 4xSPST, 2xDPST or Pulse Switch ET2145C Indoor type 1 metal ET2145CP Indoor/outdoor type 3R plastic with see-through door ET2145CR Outdoor type 3R metal The electronic mechanism snaps into the standard Intermatic enclosure for easy upgrading of mechanical mechanisms, if desired. Contact Intermatic for additional outdoor rated enclosures or see accessories on page 34. 7-DAY SCHEDULE Model # Enclosure 1-Circuit SPST Switch ET2705C Indoor type 1 metal ET2705CP Indoor/outdoor type 3R plastic with see-through door ET2705CR Outdoor type 3R metal 1-Circuit SPDT Switch ET2715C Indoor type 1 metal ET2715CP Indoor/outdoor type 3R plastic with see-through door ET2715CR Outdoor type 3R metal 2-Circuits 2xSPST, 1xDPST or Pulse Switch ET2725C Indoor type 1 metal ET2725CP Indoor/outdoor type 3R plastic with see-through door ET2725CR Outdoor type 3R metal 4-Circuits 4xSPST, 2xDPST or Pulse Switch ET2745C Indoor type 1 metal ET2745CP Indoor/outdoor type 3R plastic with see-through door ET2745CR Outdoor type 3R metal 7-DAY ASTRONOMIC SCHEDULE Model # Enclosure 1-Circuits SPST Switch ET2805C Indoor type 1 metal ET2805CP Indoor/outdoor type 3R plastic with see-through door ET2805CR Outdoor type 3R metal 1-Circuit SPDT Switch ET2815C Indoor type 1 metal ET2815CP Indoor/outdoor type 3R plastic with see-through door ET2815CR Outdoor type 3R metal 2-Circuits 2xSPST, 1xDPST or Pulse Switch ET2825C Indoor type 1 metal ET2825CP Indoor/outdoor type 3R plastic with see-through door ET2825CR Outdoor type 3R metal 4-Circuits 4xSPST, 2xDPST or Pulse Switch ET2845C Indoor type 1 metal ET2845CP Indoor/outdoor type 3R plastic with see-through door ET2845CR Outdoor type 3R metal 24 Electronic Controls Electronic Controls Basic Plus Series Timer Power TIMER POWER TIMER POWER 1-Circuit TIMER POWER CIRCUIT 1 TIMER POWER 2-Circuit TIMER POWER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 TIMER POWER PPTTOOIIMMWWEEEERRRR CIRCUIT 1 4-Circuit CIRCUIT 2 TIMER POWER TIMER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 PCOIRWCEURIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 AC IN L1 AC IN L2/N L1 PO1W2E0/R27T7OVLTA2ICM/NER (AUTO VOLTAGE, NO JUMPERS REQUIRED) POWER TO TIMER 120/208/240/277 VAC TIMER POWER (AUTO VOLTAGE, NO JUMPERS REQUIRED) AC IN NO-1 COM1 L1 L2/N L1 L2/N OUTPUT 1 INPUT 1 INDIVIDUAL 120/277 VAC LOADS OUTPUT CONFIGURATION: IND AC IN AC IN L1 NO-1 L2C/NOM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 POWER TO TIMER 120/208/240/277 VAC (AUTO VOLTAGE, NO JUMPERS REQUIRED) LOAD 1 LOAD 2 LOAD 3 LOAD 4 TIMER TIMER CPIROCWUEITR1 CIRCUIT 2 N POWLE3R N L4 N L5 N L6 AACC IINN NO-1 COM1 NO-2 COM2 ALCL11IN OUTPUT 1 INPUT 1 OUTPUT 2 INPUT 2 L1 LL22/N/N L2/N POWER TO TIMER POWER TO 1T2IM0/E20R8/240/277 VAC 120(A/2U0T8O/24V0O/2L7T7AVGAE2C,-NINODJIVUIDMUPAELR1S20R/2E7Q7UVIARCEDLO) ADS (AUTO VOLTAGE, NOOJUUTMPPUETRCSORNEFQIGUUIRRAETDIO) N: IND - CIRCUIT 1 AND 2 TIMER POWER CIRCUIT 1 CIRCUIT 2 AC IN L1 TIMER POWER 4 -TIIMNEDRIVIDUCAIRLCU1IT210/2PT7OCI7MWIREVCERUARICT 2LOCAIRDCSUIT 1 OUTPUTPOCWOERNFIGURAATCIOINN: IND - CIRCUIT 1 AND 2 OUTPUT COACNLIN1FIGURNOA-T1 IOCNOM:1INNDO--2 CCIROMC2UIT 3 AND 4 L1 TIMER POWER TIMER PCOIRWCEURIT 1 CIRCUIT 1 TIMER CIRPOCWUIEATRC2 IN CIRCUIT 2L1 CIRCUIT 3 CIRCUIT 1 CIRCUIT 2 CIRNCOU-1IT 3COM1CINROC-U2 ITC4OM2 CIRCUIT 4 OUTPUT 1 INPUT 1 OUTPUT 2 INPUT 2 L2/N L2/N OUTPUT 2 OUTPUT 1 TIMER POWER CIRCUIT 1 CIRCUIT 2 L2/N CIRPOCWUEIRTT3O TIMERCIRCUIT 4 120/208/240/277 VAC L1 AC IN TIMER POWERL1 INPUT 2 INPUT 1 L2/N AC IN PNOOW-E1 R CTOMT1IMENAROC-2IN COM2 NO-1 COM1 CIRCUIT 1120/208C/24IR0/C27U7 VITAC2 CIRCUIT 3 (AUTO VOLTAGLE1, NO JUMPERS REQUIRED) CIRCUIT 4 AC IN AC IN NO-1 COM1 NO-2 COM2 NO-1 CLO1M1 NO-2 COM2 NO-3 COM3 NO-4 COM4 INPUT 1 OUTPUT 1 (AUTO VOLTAGE, NO JUMPERS REQUIRED) L2/N POWER TO TIMER L2 2 OUTPUT C- OINNDFIVIGIDUURAALTLI12O2/NN0/:2I7N7DV-ACCIRLCOUAIDTS1 AND 2 OUTPUT 1 & 2 AC IN L1 NO-1 COM1 NO-2 LC2/ONOMU2TPNUOT2-C-3OINNDCFIOVIGIMDUU3RAALTNI1OO2-N04/:2I7N7CDOV-AMCC4IRLCOUAIDTS1 AND 2 L1 L2 CLOSE COM OPEN AC IN 120/277 VAC NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4(AUCTOOVMO4LTAGE, NO JUMPERS REQUIRED) L1 AC IN L2 TINMEOR-OC1UOTNCPFUIOGTUMCROA1NTFIONIIGNNOUD2R0-IVA82T/I2DI4OUC0NAV:OLASCIM1M2D20S/P2T7N7OV-A3C LCOOADMS3 NO-4 COM4 TIMER OCIURTCPUUITT1CONCFIIRGCUURITA2TION: IND OUTPUT OUTPUT OUTPUT 1&2 OUTPUT 3&4 1&2 3&4 TIMER CONFITGIMUERRATCIOONNFFIGOURTRITAMWTEIORON2F0O8/R2C4CI0ROVCNAUTCIATCD1TSOPRTCCOIRNCTURIOTL2 L1 TIMER POWER CIRCUIT 1 CIRCUIT 2 TIMER POWER PTIOMWEERR POWER CIRCUIT 1 CIRCUIT 2 TIMER POWER TIMCEIRRCCOUNITFI1GOUURTAPTUIOTNCFOONRFITGWUORA2T0OI8OU/2NT4P:P0OSUWVITMAECCR-OCDNISFRIPCGTUUIRTA1TIAONND: P2UL OUTPUT CONOFUIGTPUURTATCIOONNF: SIGIMUR- ACTIRIOCNU:ITSI1MA-NCDIR2CUIT 3 AND 4 L2/N OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4 LOAD 1 LOAD 2 L2 AC IN NO-1 COM1 NO-2 COM2 PTOIMWEAEARCRCININ CIRNNCOOU-1-I1T 1CCOOMM1C1 INRNOCO-U2-I2T C2 OCOMM2 2 AC IN NO-1 COM1 NO-2 COM2 COM CLOSE OPEN COM CLOSE OPEN TIMER CONFIGURATION FORL1 TWO 208/240 VAC DPST AC IN LL11 AC IN NO-1 COM1 NC-1 L1 TIMER POWER L1 AC IN L2/N OUTPUT CONFIGURATIONL:2SIM - CIRCUIT 1 AND 2 L1 OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4 OUTPUT 1 & 2 L2/N TIMER POWER CIRCUIT 1 TIMER CONFIGURATION 208/240 VAC DSPT POWER TO TIMER OUTPUT CONFIGURATION: SIM 120/208/240/277 VAC CIRCUIT 2 CIRCUIT 3 CIR(ACUUTOITV4OLTAGE, NO JUMPERS REQUIRED) For SPDT Models AC IN TIMER POWER TIMER POWER CIRCUIT 1 TIMER POWER CIRCUIT 2 NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 LOAD 1 LOAD 2 L1 ACLI1N L2/N AC IN NO-1 COM1 LOAD 3 NO-2 L1 AC IN COM2 CIRCUIT 1 L1 NO-1 COM1 NC-1 L2/N TIMER COLL22N/NFIGURATION FOR TWO CONTACTLO1 R CONTROLS L2/N CLOSE COM OPEN OUTPUT 1 INPUT 1 OUTPUT 2 OUTPUT OUTPUT CONFIGURATIONOU: TPPUUTL CAOC NINFIGUNROA-1TIOCONM1:1&PN2UOL-2- CCCOIIRRMCC2 UULIITT2/N13 AND AND 2 4 L1 TIMER CONFIGURATION 208/240 VAC DSPT TIMER POWER TIMER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 PCOIRWCEURIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CLOSE COM OPEN OUTPUT CONFIGURATION: SIM L2/N TIMER POWER TIMECR CIROCNFUOIGUITUTPR1UAOTTUI1COTO&NPN2UFCFOTIGRIRUCCROAUNTTIIOTANC2:TPOURLCONCTORIUROTLCPUUT2ITC- 3IONNDFIVIGIDCUUIRRAACLT1UIO2I0NT/:24I7N7DV-ACCIARLCCOIUANIDTS1 ANNDO-21 TIMER CONFIGURATION FOR CONTACTOR CONTROL OUTPUT CONFIGURATION: PUL COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 OUTPUT CONFIGURATION: PUL - (BELL RINGING) L1 TIMER CIRCUIT 1 CIRCUIT 2 L1 POWER TIMER POWER CIRCUIT 1 CIRCUIT 2 L2/N L2/N OUTPUT AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 OUTPUT 3&4 3&4 TIMER CONFIGURATION FOR COMBINATION MODE AC IN NO-1 COM1 NO-2 COM2 TIMOEURTCPOUNTFCIGOUNRFAIGTUIORNATFIOORN:CIONDMB- ICNIARTCIUOINT M1 OANDDE 2 (120/277 VAC LOAD) L1 AC IN NO-1 COM1 NO-2 COM2 OUTPUT CONOFUIGTPUURTATCIOONNF: IINGDUR- ACTIRIOCNU:ITSI1MA-NCDIR2C(U12IT0/327A7NVDA4C(2L0O8A/2D4)0 VAC LOAD) OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4 (208/240 VAC LOAD) LL21/N LOAD 1 LOAD 2 LOAD 3 OUTPUT 1 INPUT 1 OUTPUT 2 INPUT 2 OUTPUT 1 INPUT 1 OUTPUT 1 OUTPUT 2 INPUT 1 INPUT 2 OUTPUT 2 INPUT 2 INPUT 3 INPUT 4 INPUT 3 INPUT 4 OUTPUT 1 INPUT 1 OUTPUT 2 L2/N POWER TO TIMER L2/N L2/N POWER TO TIMER N L3 N L4 (AUTO VOL1T2A0G/2OE0U18, T/N&2PO42U0JT/2U7M7PVEARCS L5 L6 REQUIRED) 20/208/240/277 VAC AGE, NO JUMPERS REQUIRETDIM) ER CONFIGURATION FOROUCTPOUTMCBOINNFAIGTUIROANTIOMN:OPUDLE- (BELL RINGING) OUTPUT OUTPUT CONFIGURATION: CONFIGURATION: IND SIM - CIRCUIT CIRCUIT 1 3 AND AND 2 4 ((122008//227470OVVUAATPCCULT2LOOC- IOAANNDDDFI))VIGIDUURAALT1IO20N/:2I7N7DV-ACCIRLCOUAIDTS1 AND 2OUTPUT OUTPUT L3 L5 N L6 OUTPUT 2 - INDIVIDUAL 1120&/2277 VAC LOADS TIMEORUTCPOUTNCFOINGFIUGURRAATTIIOONN: INFDO- CRIRCCUOITM1 BANIND A2 TION MODE OUTPUT CONFIGURATION: PUL - (BELL RINGING) CONFIGURATION: SIM - CIRCUIT 1 AND 2 (208/240 CONFIGURATION: IND - CIRCUIT 3 AND 4 (120/277 N L7 VVAACCPTOILLMWOOEERAARDD)) TIMER PCOIRWCEURIT 1 CIRCUIT 1 CIRCUIT 2 CIRCUIT 2 CIRCUIT 3 CIRCUIT 3 CIRCUIT 4 CIRCUIT 4 L1 L2/N AC IN L1 L2/N AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 OUTPUT 1 INPUT 1 OUTPUT 1 OUTPUT 2 INPUT 1 INPUT 2 OUTPUT 2 OUTPUT 3 INPUT 2 INPUT 3 OUTPUT 3 OUTPUT 4 INPUT 3 INPUT 4 OUTPUT 4 INPUT 4 4 - INDIVIDUAL 120/277 VAC LOADS 4 - INDOIUVTIDPUUATLC1O20N/F2I7G7UVRAACTLIOONA:DINSD - CIRCUIT 1 AND 2 OUTPUT CONOFUIGTPUURTATCIOONNF: IINGDUR- ACTIRIOCNU:ITIN1DA-NCDIR2CUIT 3 AND 4 OUTPUT CONFIGURATION: IND - CIRCUIT 3 AND 4 TIMER POWER TIMER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 PCOIRWCEURIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 L1 L2/N AC IN L1 L2/N AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 CLOSE COM CLOSE OPEN COM OPEN CLOSE COM CLOSE OPEN COM OPEN TIMER CONFIGURATION FOR TWO CONTACTOR CONTROLS TIMER CONFIGUROATUITOPNUFTOCROTNWFIOGUCROANTTIAOCNT: OPURLC-OCNIRTRCOUILTS1 AND 2 OUTPUT CONOFUIGTPUURTATCIOONNF: PIGUULR-ACTIIROCNU: IPTU1LA-NCDIR2CUIT 3 AND 4 OUTPUT CONFIGURATION: PUL - CIRCUIT 3 AND 4 TIMER POWER TIMER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 PCOIRWCEURIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 L1 L2/N AC IN L1 AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 INPUT 1 INPUT 2 OUTPIUNTP3UT 1 INPUT 2 INPUT 3 OUTPUT 3 OUTPUT 4 INPUT 3 INPUT 4 OUTPUT 4 INPUT 4 L2/N OUTPUT OUTPUT 1&2 1&2 TIMER CONFIGURATION FOR COMBINATION MODE TIMOEURTCPOUNTFCIGOUNRFAIGTUIORNATFIOORN:CSOIMMB- ICNIARTCIUOINT M1 OANDDE 2 (208/240 VAC LOAD) OUTPUT CONOFUIGTUPURTATCIOONN:FSIGIMUR- ACTIRIOCNU:ITIN1DA-NCDIR2C(U20IT8/324A0NVDA4C(1L2O0A/2D7)7 VAC LOAD) OUTPUT CONFIGURATION: IND - CIRCUIT 3 AND 4 (120/277 VAC LOAD) TIMER POWER TIMER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 PCOIRWCEURIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 TIMER POWER CIRCUIT 1 CIRCUIT 2 TIMER POWER CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 AC IN NO-1 COM1 NO-2 COM2 L1 AC IN L2 NO-1 COM1 NO-2 COM2 NO-3 COMO3U1T&NP2UOT -4 COM4 TIMER CONFIGURATION 208/240 VAC DSPT L1 OUTPUT CONFIGURATION: SIM L2/N LOAD1 LOAD2 TIMER POWER N 20 TITLELOAD3 CIRCUIT 1 CIRCUIT 2 LISTED L3 N L4 L1 L2/N CLOSE COM OPEN OUTPUT 3 INPUT 3 OUTPUT 3 OUTPUT 4 INPUT 3 INPUT 4 OUTPUT 4 INPUT 4 TIMER POWER AC IN TIMER POWER CIRCUIT 1 CIRCUIT 2 AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3L1 AC IN L1 CIRCUIT 4 NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 L1 L2/N AC IN NO-1 COM1 NO-2 COM2 L2/N L2/N OUTPUT 1&2 OUTPUT 1&2 TIMER CONFIGURATION FOR COMBINATION MODE TIMEROUCTOPNUFTIGCUORNAFTIGIOUNRFAOTIROCNO: PMUBLIN- ACTIRIOCNUIMTO1DAEND 2 (BELL RINGING) NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COOUMTP4UT CONFIGURAOTIUOTNP:UPTUCLO- NCFIRIGCUURITA1TIAONND: I2N(DBE- CLLIRRCINUGITIN3GA)ND 4 OUTPUT CONFIGURATION: IND - CIRCUIT 3 AND 4 TIMER CONFIGURATION FOR CONTACTOR CONTROL OUTPUT CONFIGURATION: PUL LOAD 2 LOAD1 240VAC L1 L2/N 240 VAC AC IN L1 AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 L2/N OUTPUT 1&2 240 VAC OUTPUT 1&2 OUTPUT 3&4 OUTPUT 3&4 TIMER CONFIGURATION FOR COMBINATION MODE TIMEROUCTOPNUFTIGCUORNAFTIGIOUNRFAOTIROCNO: PMUBLIN- ACTIRIOCNUIMTO1DAEND 2 (BELL RINGING) OUTPUT COONUFTIPGUUTRCAOTINOFNIG: PUURLA-TCIOIRNC: SUIIMT 1- CAINRDCU2 I(TBE3LALNRDIN4G(2IN08G/)240 VAC LOAD) OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4 (208/240 VAC LOAD) RATINGS: SPST TIMER CONFIGURATION FOR COMABCININATIONNO-M1 OCDOME1 NO-2 COM2 RATINGS: SPDT TIMER CONFIGURATION FOR COMBINATION MODE OUTPUT CONFIGURATION: PUL - CL1IRCUIT 1 AND 2 (BELL RINGING) OUTPUT CONFIGURATION:PUL - CIRCUIT 1 AND 2 (BELL RINGING) Input Voltage OUTPUT CONFIGURATION: IND - CIRCUIT 3 AND 4 L2/N 120-277 VAC, 60 Hz Input Voltage 120-277 VAC, 60 OUTPUT CONFIGURATION: SIM - CIRCUIT 3 AND 4 (208/240 VAC LOAD) Hz OUTPUT NO Contacts 1 & 2 OUTPUT CONFIGURATION: PUL - (BELL RINGING) NO Contacts RATINGS: 2XSPST, 1XDPST OR PULSE Input Voltage 120-277 VAC, 60 Hz NO Contacts Electronic Ballast (LED) 10 A, 120/277 VAC, 60 Hz Electronic Ballast (LED) 10A, 120/277 VAC, 60 Hz Electronic Ballast (LED) 10A, 120/277 VAC, 60 Hz Ballast (Fluorescent) 20 A, 120-277 VAC, 60 Hz Inductive 30 A, 120-240 VAC, 60 Hz Resistive (Heater) 20 A, 28 VDC; 30 A, 120-240 VAC, 60 Hz Tungsten (Incandescent) 5 A, 120-277 VAC, 60 Hz Motor 1 HP, 120 VAC, 60 Hz; 2 HP, 240 VAC, 60 Hz Warranty 2-Year limited Operating Temperature -40°F - 104°F (-40°C - 40°C) Ballast (Fluorescent) Inductive Resistive (Heater) Motor NC Contacts Ballast (Fluorescent) Inductive Resistive (Heater) Motor 20 A, 120-277 VAC, 60 Hz 20 A, 120-240 VAC, 60 Hz 20 A, 28 VDC; 20 A, 120-240 VAC, 60 Hz 1 HP, 120 VAC, 60 Hz; 2 HP, 240 VAC, 60 Hz 3 A, 120-277 VAC, 60 Hz 10 A, 120-240 VAC, 60 Hz 10 A, 28 VDC; 10 A, 120240 VAC, 60 Hz 1/4 HP, 120 VAC, 60 Hz; 1/2 HP, 240 VAC, 60 Hz Ballast (Fluorescent) 20 A, 120-277 VAC, 60 Hz Inductive 30 A, 120-240 VAC, 60 Hz Resistive (Heater) 20 A, 28 VDC; 30 A, 120-240 VAC, 60 Hz Tungsten (Incandescent) 5 A, 120-277 VAC, 60 Hz Motor 1 HP, 120 VAC, 60 Hz; 2 HP, 240 VAC, 60 Hz Warranty 2-Year limited Operating Temperature -40°F - 104°F (-40°C - 40°C) Warranty 2-Year limited Operating Temperature -40°F - 104°F (-40°C - 40°C) 25 Electronic Controls Electronic Controls Basic Series ET1125C ET1705C ET1100 Series, ET1700 Series, ET8000 Series BASIC ELECTRONIC TIME SWITCHES This series offers an easy way to upgrade from a basic mechanical time switch to an electronic time switch. These timers will allow for up-to-the-minute programming, battery backup for power loss, up to 28 events total, and automatic daylight saving time corrections without the need of user interaction. They come in standard 24-hour, 7-day and 7-day astronomic versions. APPLICATIONS · Outdoor Lighting Control · Timing/Scheduling ON/OFF · Machinery & Pump Controls FEATURES · Selector switch to determine input voltage between 120-277 VAC, 50/60 Hz · Up to 28 events total · To-the-minute accuracy · Temporary override or permanent manual override · Automatic Daylight Saving Time adjustment · Astronomic models enable dusk-to-dawn scheduling ET8215C 24-HOUR SCHEDULE Model # Enclosure 1-Circuit SPST Switch ET1105C Indoor type 1 metal 2-Circuits 2xSPST, 1xDPST or Pulse Switch ET1125C Indoor type 1 metal 20 TITLE LISTED RATINGS: SPST Input Voltage 120-277 VAC, 50/60 Hz NO Contacts Electronic Ballast (LED) 1 A, 120-277 VAC Ballast (Fluorescent) 20 A, 120-277 VAC Inductive 30 A, 120/240 VAC Resistive (Heater) 20 A, 28 VDC; 30 A, 120/240 VAC Tungsten (Incandescent) 5 A, 120/240 VAC Motor 1 HP, 120 VAC; 2 HP, 240 VAC Warranty 1-Year limited Operating Temperature -40°F - 104°F (-40°C - 40°C) 7-DAY SCHEDULE Model # Enclosure 1-Circuit SPST Switch ET1705C Indoor type 1 metal 2-Circuits 2xSPST, 1xDPST or Pulse Switch ET1725C Indoor type 1 metal RATINGS: 2XSPST, 1XDPST OR PULSE Input Voltage 120-277 VAC, 50/60 Hz NO Contacts Electronic Ballast (LED) 1 A, 120-277 VAC Ballast (Fluorescent) 20 A, 120-277 VAC Inductive 30 A, 120/240 VAC Resistive (Heater) 20 A, 28 VDC; 30 A, 120/240 VAC Motor 1 HP, 120 VAC; 2 HP, 240 VAC Warranty 1-Year limited Operating Temperature -40°F - 104°F (-40° - 40°C) 7-DAY ASTRONOMIC SCHEDULE Model # Enclosure 1-Circuit SPST Switch ET8015C Indoor type 1 metal 2-Circuits 2xSPST, 1xDPST or Pulse Switch ET8215C Indoor type 1 metal 4-Circuits 4xSPST, 2xDPST or 2xPulse Switch ET8415CR* Outdoor type 3R metal Rated for 4.5 A Electronic Ballast (LED) Enclosure Type Indoor type 1 metal Dimensions 7.875" x 5.125" x 3.4375" (200 mm x 130.2 mm x 87.3 mm) Knockout Dimensions Side/Back (1) combination 1/2" - 3/4" Bottom (2) combination 1/2" - 3/4" The electronic mechanism snaps into the standard Intermatic enclosure for easy upgrading of mechanical mechanisms, if desired. For outdoor rated metal enclosures contact Intermatic. For accessories see page 34 For enclosure line drawings and knockout locations, see pages 35 & 186. 26 ET1100, ET1700, ET8000 SERIES Timer Power 123 Neutral Line 120 VAC Input Load Single Circuit 120 VAC-SPST 4 Install jumper if the loads are on the same circuit as the input for the control Timer Power ON Pulse OFF Pulse 123456 L2/Neutral L1 CLOSE COM 2-Circuit Pulse 2x SPST Mechanically Held OPEN Contactor Configure jumper set to PUL. Timer Power 1 L2 L1 2 3 45 Load 1 Load 2 SPDT (ETXX15 models) (load switching) Install jumper if the loads are on the same circuit as the input for the control Timer Power 1234 L2 L1 240 VAC Input 2-Circuit (SIM) Configuration jumper set to "SIM". 56 Load Timer Power 123456 L2/ Neutral L1 Load 2-CConirficguuriatti(oPnejurmBpeerllseRt itnog"PinULg")Each event, ON or OFF, Rings Bell. Timer Power 123456 L2/Neutral L1 120/208/240/277 VAC Input Load Load L3 1 L5 2 L4/Neutral 2-Circuit (IND) Configuration jumper set to "IND". L6/Neutral Electronic Controls Basic Series ET8415CR WIRING DIAGRAMS There are many different ways to set the relays on the ET8415CR Time Switch. The four relays can be used individually or in pairs of two. Refer to the table below for a complete list of ways to set the relays and illustrations for some of the common wiring installations. Possible switching configurations IND/IND IND/SIM IND/PUL SIM/IND SIM/SIM SIM/PUL PUL/IND PUL/SIM PUL/PUL Note: IND= Independent SIM= Simultaneous PUL= Pulse 2x DPST EXAMPLE: 2x DPST OperatOiopneraMtioondMeosdeetsteot tSoI"MSIMfo"rfobr booththssettssooffcocnotnactatsc,Itnsp,uitnapnudtOauntpdut voltage output voltage are the same. are the same NOTE: Each relay is a dry contact. Other voltages can be used if dedicated supply voltage is used for COM terminals. L2 L1 AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 Load 2 240 VAC Load 240 VAC Load 1 240 VAC Load L3 L4 240 VAC EXAMPLE: 4x SPST 4x SPST Operation MOopdeerastieotntMo oINdeD,seint ptou"tINanDd", IonuptuptuatndvoOltuatgpuetavroeltathgee asraemthee. same NOTE: Each relay is a dry contact. Other voltages can be used if dedicated supply voltage is used for COM AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 terminal replacing L1. Neutral/L2 L1 120/208/240/277 VAC Input Load 1 Load 2 Load 3 Load 4 2x Pulse Operation mode set to PUL for both seEtsXoAf cMonPtaLcEts:, each ON and OFF event for circuit 1 will ring the bell. Each ON ev2exnPt ufolsre Circuit 3 will close contactor Operation Mode set to"PUL" For both sets of contacts,Each ON and OFF event and each OFfoFr Ceivrceunitt1wwiillllroinpgethnecboenll.tEaaccthoOr.N event for Circuit3 will Close Contactor and Each OFF event will Open Conta.ctor NOTE: Each relay is a dry contac.t Other voltages can be used if dedicated supply voltage is used for COM terminals. AC IN NO-1 COM1 NO-2 COM2 NO-3 COM3 NO-4 COM4 Neutral/L2 L1 120/208/240/277 VAC Input Bell L3 120/208/240/277 VAC 28 VDC Input Neutral/L4 Load 3 Closed Open Maintained Contactor COM 27 Electronic Controls Electronic Controls Electronic Controls Electronic All-Purpose Contractor Box ETCB28253PCR Contractor Box ELECTRONIC ALL-PURPOSE CONTRACTOR BOX The ETCB28253PCR is a field-ready solution that provides a durable Type 3-R Enclosure, a built-in 7/365 Day Astronomic Timer, 60 Amp 3-Pole contactor, inputs for timed photocontrol override, switched override capabilities, as well as inputs for surge protective devices. The timer allows for 96 ON/OFF events, 50 holiday blocks with independent scheduling, Astronomic scheduling, and 100-hour backup without the need of replacing batteries. The clock input voltage is 120 VAC, 60 Hz. The contactor has a 120 VAC coil to turn it on or off, which is completely independent of the voltage ratings that can be used with the contactor itself. The contactor can be used for 120-480 VAC, 60 Hz APPLICATIONS · Indoor Lighting Control · Outdoor Lighting Control · 3-Phase Motor Control · Timing/Scheduling ON/OFF · Machinery & Pump Controls FEATURES · 3-Pole 60 A Contactor · Timed photo control inputs · Surge Protection Inputs · 100-hour supercapacitor eliminates the need for batteries · Up to 96 set points or events · Up to 50 Holiday blocks with schedule capabilities · Astronomic settings to automatically adjust for sunrise and sunset times based on location · Additional mode of operation turns the ON/OFF buttons into 2-hour overrides · Non-volatile EEPROM memory protects programming indefinitely · USB port makes transferring and saving of schedules easy · 2-year limited warranty RATINGS Input Voltage Restive (Heater) Motor Warranty Operating Temperature 120 VAC, 60 Hz 60 A 5 HP, 120 VAC;10 HP, 240 VAC, (Single-Phase); 25 HP (360 LRA), 240 VAC; 30 HP (300 LRA), 480 VAC 2-Year limited -40°F - 104° F (-40°C - 40°C) Model # ETCB28253PCR Switch Type 3xSPST Enclosure Indoor/outdoor type 3 metal WANT MORE? For additional products check out our Surge Protection Solutions starting on page 118 and our Photocontrol Solutions starting on page 88. Stay updated on new Contractor Box solutions by visiting Intermatic.com. 28 Electronic Controls WIRING DIAGRAMS Electronic Controls Electronic All-Purpose Contractor Box INPUTS INPUT OUTPUTS ENCLOSURE DIMENSIONS 10" 10" 4 3/4" 4 3/4" 11 3/4" 11 3/4" 12 3/8" 12 3/8" KNOCKOUTKN1O/2C" AKNODUT3/14/"2" AND 3/4" (19 PLACES(1)9 PLACES) 2 1/2" 2 1/2" 5" 5" KNOCKOUTKN3O/4C" AKNODUT1"3/4" AND 1" (3 PLACES()3 PLACES) 29 Electronic Controls Electronic Controls Panel, Surface/DIN Rail Mount - 24-Hour or 7-Day FM1D14 Series 15A, 1 CIRCUIT, 14 PROGRAM ELECTRONIC TIMER 20 TITLE LISTED FM1D14-24U The FM1D14 Series is a great value electronic time-based control solution for ventilating, heating, cooling, lighting or other electrical loads in commercial and industrial applications. These one-channel time switches are programmable for 24-hour or 7-day schedules. The FM1D14 Series is intended for either panel, surface or DIN rail mounting. Surface/DIN rail are completely enclosed in a plastic housing and include a terminal cover, dust cover and subbase for installation and hard wiring. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation· Aeration · Septic Treatment· Generator Exercising FEATURES · 24-Hour or 7-day applications · 14 Set point programs · Easy to program · Manual override with status indication · Self-recharging battery with backup protection up to 2500-hours · LCD display · 5 Preset adjustable block programs · A models come with clear dust cover RATINGS Input Voltage Power Consumption VA Switch Type NO Contacts Ballast (Fluorescent) Tungsten (Incandescent) Pilot Duty Motor NC Contacts Resistive (Heater) Motor Wiring Terminals Operating Temperature Warranty See Model Chart 4 SPDT 8 A, 277 VAC 1000 W, 120 VAC B300 1/2 HP @ 120 VAC, 1 HP @ 250 VAC, 10 FLA, 60 LRA @ 250 VAC M 12 A, 24 VDC 12 1/2 HP @ 120/240 VAC, 10 FLA, COM NO NC 3 45 60 LRA @ 250 VAC Normally Open (Dry Contact) Screw terminals for #24 to #10 AWG wire L1 L2/N Normally Closed (A models) (Dry Contact) -40°F - 131°F (-40°C - 55°C) Typical Wiring (12, 24 VDC Application) 1-Year limited Model # FM1D14-24U FM1D14-AV-U FM1D14A-24 FM1D14A-AV Mounting Panel Panel DIN Rail, Surface DIN Rail, Surface Input Voltage 24 VAC/VDC, 50/60 Hz 120-277 VAC, 50/60 Hz 24 VAC/VDC, 50/60 Hz 120-277 VAC, 50/60 Hz Programs 14 14 14 14 WIRING DIAGRAMS Typical Wiring: Typical Wiring (24-277 VAC Application) 24-277 VAC Application M M 12 12 120-277 VAC L1 L2/N L1 L2/N COM NO NC 3 COM 4 NO 5 NC 3 45 Normally Open LOAD (Dry Contact) Normally Closed (Dry Contact) Typical Wiring: 24 VDC Application Typical Wiring (12, 24 VDC Application) Typical Wiring (24 VDC Application) DIMENSIONS Typical Wiring (24-277 VAC Application) FM1D14A Surface/DIN Rail with Clear DuWstithCcolevaer r dust-cover M 12 2.83" [72 mm] COM NO NC 3 45 2.06" [52 mm] 1.56" [39.5 mm] 120-277 VAC L1 L2/N LOAD 4.00" [102.5 mm] Typical Wiring (24 VDC Application) 2.60" [66 mm] 1.50" [38 mm] + M12 12, 24 VDC (+) (-) COM NO NC 3 45 LOAD + M+ M12 12 COM NO NC 3 COM 4 NO 5 NC 3 45 LOAD 12, 24 V24DCVDC LOAD (+) (-) (+) (-) NO & NC Switching Configuration + MF-M1D14 Surface/DIN Rail 12 24 VDC C2O.3M6 in. NO NC 3[60 mm4 ] 5 2.13 in. [54 mm] LOAD .14 in [3.56 mm] (+) (-) Typical Wiring (24-277 VAC Application) 2.36 in. [60 mm] 1 2 345 30 M 12 L1 L2/N COM NO NC 3 45 Normally Open (Dry Contact) Normally Closed (Dry Contact) Typical Wiring (12 VDC Application) M .14 in [3.56 mm] COM NO NC 12 3 45 24-277 VAC L1 L2/N LOAD Typical Wiring (24 VDC Application) + M12 COM NO NC 3 45 + M12 COM NO NC 3 45 Electronic Controls Electronic Controls Panel, Surface/DIN Rail or Flush Mount - 24-Hour or 7-Day FM1D20 Series 16 A, 1-CIRCUIT TIMER MODULES The FM1D20 Series Electronic Time Controls are for ventilating, heating, cooling, lighting or other electrical loads in commercial and industrial applications. These one-channel time switches are programmable for 24-hour or 7-day schedules. They are intended for either panel, surface, flush, or DIN rail mounting. Flush and surface/DIN rail (A & E models) are completely enclosed in a plastic housing and include a terminal cover, dust cover and subbase for installation and hard wiring. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · 24-Hour or 7-day applications · 20 Set point programs · Three preset adjustable block programs · Easy-to-follow menu driven programming · Manual override with status indication · Battery backup · Large LCD · Daylight Saving Time adjustment · A & E models come with clear dust cover Model # FM1D20-24U FM1D20-120U FM1D20A-24 FM1D20A-120 FM1D20A-240 FM1D20E-24 FM1D20E-120 Mounting Panel Panel DIN Rail, Surface DIN Rail, Surface DIN Rail, Surface Flush Flush Input Voltage 24 VAC/VDC, 50/60 Hz 120 VAC, 50/60 Hz 24 VAC/VDC, 50/60 Hz 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 24 VAC/VDC, 50/60 Hz 120 VAC, 50/60 Hz Programs 20 20 20 20 20 20 20 DIMENSIONS FM1D20A Surface/DIN Rail with Clear DuWsitht cCleoarver dust-cover 2.83" [72 mm] 2.06" [52 mm] 1.56" [39.5 mm] FM1D20E Flush Mount with Clear Dust Cover 2.83" [72 mm] 4.00" [102.5 mm] 2.37" 2.12" 60.1 mm 53.7 mm 2.83" [72 mm] 2.60" [66 mm] 1.50" [38 mm] FM1D20 Flush Mount with Clear Dust Cover .13" 3.4 mm 2.37" 60.1 mm 2.12" 53.7 mm 2.37" 60.1 mm 2.37" 60.1 mm 2.43" 61.7 mm FM1D20-24U 20 TITLE LISTED RATINGS Input Voltage Power Consumption VA Switch Type NO Contacts Ballast (Fluorescent) Tungsten (Incandescent) Pilot Duty Motor NC Contacts Resistive (Heater) Wiring Terminals Operating Temperature Warranty WIRING DIAGRAMS NO/NC Switch Configuration See Model Chart 4 SPDT 8 A, 240 VAC, 12 A, 120 VAC 600 W, 120 VAC, 1000 W, 240 VAC 360 VA, 120 VAC, 720 VA, 240 VAC 1/2 HP, 120 VAC, 1 HP, 240 VAC 16 A, 277 VAC, 8 A, 24 VDC M 1/4" Quick connect terminals COM N.O. N.C. -13°F - 131°F 1(-25°C2 - 55°3C) 4 5 1-Year limited L1 L2/N Normally Open (Dry Contact) Normally Closed (Dry Contact) Typical Wiring: 24-120 VAC Application M 1 2 L1 L2/N M COM N.O. N.C. 3 4 5 1 2 Normally Open (Dry Contact) Normally Closed (Dry Contact) 24-120 VAC Hot Neutral Typical Wiring: 24 VDC Application COM N.O. N.C. 3 4 5 LOAD .13" 3.4 mm .08" 2 mm .83" 21 mm 1.26" 31.9 mm 2.43" 61.7 mm .08" 2 mm .83" 21 mm M 1 2 24-120 VAC Hot Neutral COM 3 M N.O. N.C. 4 5 1 2 LOAD 12 or 24 VDC (+) () COM 3 N.O. 4 1 M N.C. 5 2 LOAD 12 or 24 VDC (+) () COM N.O. N.C. 3 4 5 LOAD M 31 Electronic Controls Electronic Controls Surface/DIN Rail or Mount - 24-Hour or 7-Day FM1D50A-24 20 TITLE LISTED RATINGS Input Voltage Power Consumption VA Switch Type NO Contacts Ballast (Fluorescent) Resistive (Heater) Tungsten (Incandescent) Pilot Duty Motor NC Contacts Resistive (Heater) Wiring Terminals Operating Temperature Warranty See Model Chart 4 SPDT 8 A, 240 VAC, 12 A, 120 VAC 16 A, 277 VAC 600 W, 120 VAC, 1000 W, 240 VAC 360 VA, 120 VAC, 720 VA, 240 VAC 1/2 HP, 120 VAC, 1 HP, 240 VAC 16 A, 277 VAC Screw terminals for #24 to #10 AWG wire -13°F - 131°F (-25°C - 55°C) 1-Year limited FM1D50 Series 16 A, 1-CIRCUIT TIMER MODULES The FM1D50 Series Electronic Time-Based Controls enable switching of ventilation, heating, cooling, lighting or other electrical loads in commercial and industrial applications. These one-channel time switches are programmable for 24-hour or 7-day schedules. They are intended for DIN rail mounting. Surface/DIN rail models are completely enclosed in a plastic housing and include a terminal cover, dust cover and subbase for installation and hard wiring. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · 24-Hour or 7-day applications · 50 Set point programs · Two preset adjustable block programs · Easy-to-follow menu driven programming · Manual override with status indication · Battery backup · Large LCD ·Seven available languages: English, German, French,Italian, Spanish, Portuguese and Dutch · Auto Daylight Saving Time feature · A & E Models come with clear dust cover Model # FM1D50A-24 FM1D50A-120 Mounting DIN Rail, Surface DIN Rail, Surface Input Voltage 24 VAC/VDC, 50/60 Hz 120 VAC, 50/60 Hz Programs 50 50 WIRING DIAGRAMS NO/NC Switching Configuration M COM N.O. N.C. 1 2 3 4 5 L1 L2/N Normally Open (Dry Contact) Normally Closed (Dry Contact) Typical Wiring: 24 VDC Application DIMENSIONS FM1D50A Surface/DIN Rail withWCiltehacrleDarust Cover dust-cover 2.83" [72 mm] 2.06" [52 mm] 1.56" [39.5 mm] 4.00" [102.5 mm] 2.60" [66 mm] 1.50" [38 mm] MM 1M 2 1 2 3CCOOMM 4NN..OO.. 5NN..CC.. 3 4 5 COM LOAND.O. 1 2 3 L4OAD 12V24A-oC1r2204 VDC Normally Open Hot Neutral L(+1) L2(/N) (Dry Contact) Normally Closed (Dry Contact) Typical Wiring: 24-120 VAC Application N.C. 5 M M 1 2 1 2 12 or 24 2V4D-C120 (+) VAC () Hot Neutral COM 3COM 3 N.O. 4N.O. 4 LOAD LOAD N.C. 5N.C. 5 32 M COM N.O. N.C. Electronic Controls 2.28" [58 mm] 65" mm] m] Electronic Controls Flush and Surface Mount - 24-Hour or 7-Day FM2D50 Series 16 A, 2-CIRCUIT TIMER MODULES The FM2D50 Series provides 2-circuit, time-based control of ventilation, heating, cooling, lighting or other electrical loads in commercial and industrial applications. These one-channel time switches are programmable for 24-hour or 7-day schedules. They are intended for surface, flush or DIN rail mounting. The control is completely enclosed in a plastic housing and includes a terminal cover, dust cover and subbase for installation and hard wiring. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · 24-Hour or 7-day applications · Auto Daylight Saving Time (DST) feature · 2-Circuit independent programming · 50 Set point programs · Two preset adjustable block programs · Easy-to-follow, menu-driven programming · Seven available languages: English, German, French, Italian, Spanish, Portuguese and Dutch · Surface, Flush or DIN rail mounting (for DIN rail mounting, order MB-DIN base, sold separately) · Manual override with status indication · Battery backup · Large LCD · Clear dust cover 20 TITLE LISTED Model # Mounting Input Voltage Programs RATINGS FM2D50-24 FM2D50-120 FM2D50-240 DIN Rail, Flush, Surface DIN Rail, Flush, Surface DIN Rail, Flush, Surface 24 VAC/VDC, 50/60 Hz 50 120 VAC, 50/60 Hz 50 240 VAC, 50/60 Hz 50 Input Voltage Power Consumption VA Switch Type NO Contacts Ballast (Fluorescent) Resistive (Heater) DIMENSIONS WIRING DIAGRAMS Tungsten (Incandescent) 2.83" [72 mm] NO/NC Switching Configuration Pilot Duty Motor NC Contacts Ballast (Fluorescent) Resistive (Heater) Wiring Terminals 12 345 67 8 Typical Wiring: 24 VAC/VDC Application Operating Temperature 24 VAC/VDC Warranty FM2D50-24 See Model Chart 4 2xSPDT 8 A, 240 VAC, 12 A, 120 VAC 16 A, 277 VAC 600 W, 120 VAC, 1000 W, 240 VAC 360 VA, 120 VAC, 720 VA, 240 VAC 1/2 HP, 120 VAC, 1 HP, 240 VAC 8 A, 240 VAC, 12 A, 120 VAC 16 A, 277 VAC Screw terminals for #24 to #10 AWG wire -13°F - 131°F (-25°C - 55°C) 1-Year limited 2.28" [58 mm] 1.65" [42 mm] 2.83" [72 mm] 2.60" [66 mm] 4" [102.5 mm] 0.96" [25 mm] 120 VAC 12204 VAC/VDC Typical Wiring: 120 VAC 12 345 67 8 120 VAC120 VAC 240 VAC 24 VAC24/VVDACC/VDC 240 VAC Typical Wiring: 240 VAC 240 VA2C40 VAC 33 Electronic Controls Electronic Controls Enclosed Timer Module - 24-Hour and/or 7-Day GM40AVE-RD89 20 TITLE LISTED RATINGS Input Voltage Switch Type NO Contacts Electronic Ballast (LED) Resistive (Heater) Tungsten (Incandescent) Motor NC Contacts Electronic Ballast (LED) Resistive (Heater) Tungsten (Incandescent) Motor Wiring Terminals Operating Temperature Warranty See Model Chart DPDT 30 A, 120 VAC, 50/60 Hz; 20 A, 277 VAC, 50/60 Hz 40 A, 120-277 VAC, 50/60 Hz 15 A, 120 VAC, 50/60 Hz 1 HP, 16 FLA, 96 LRA @ 120 VAC, 50/60 Hz; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC, 50/60 Hz 10 A, 277 VAC, 50/60 Hz 30 A, 120-277 VAC, 50/60 Hz 2 A, 120 VAC, 50/60 Hz 1 HP, 12 FLA, 30 LRA @ 120 VAC, 50/60 Hz; 2 HP, 10 FLA, 30 LRA @ 240 VAC, 50/60 Hz Screw box lug -40°F - 131°F (-40°C - 55°C) 1-Year limited GM40AVE 40 A AUTO-VOLTAGE GENERAL PURPOSE ELECTRONIC TIME SWITCH The GM40AVE is a universal, electronic time switch designed for general purpose residential and commercial applications. The robust 40 A time control automatically detects the input voltage without the use of a DIP switch or selector pins. The time switch automatically selects any voltage between 120 VAC and 277 VAC. The mechanism is mounted in a compact UL Type 3R outdoor enclosure and can also be easily retrofitted into other Intermatic enclosure types. The time control features a DPDT switching configuration standard (i.e. two normally open and two normally closed contacts). APPLICATIONS · Aeration, Air Movement & Ventilation · Generator Exercising · Refrigeration Merchandiser · Septic Treatment FEATURES · Heavy-duty 40 A contact rating · Automatically adjusts voltages between 120-277 VAC · 24-Hour/7-day flexible scheduling · Power and status LED indicators · DPDT switching configuration (2 NO and 2 NC Contacts) · 14 Set point programs · Manual override with load status indication · Self-recharging battery with back up protection up to 2500 hours · Type 3R outdoor enclosure with lockable hasp · To-the-minute accuracy Model # GM40AVE-RD89 Input Voltage 120-277 VAC, 50/60 Hz Battery Backup 2500 Hours WIRING DIAGRAMS Typical Wiring: 208/240 VAC TIMER T L1 L2/N NC NO COM NC2 NO2 COM2 L1 L2 208/240 VAC LOAD Typical Wiring: 120/277 VAC TIMER T 208/240 VAC L 1 L 2/N NC NO COM NC 2 NO 2 COM2 L N 120/277 VAC LOAD #1 LOAD #2 DIMENSIONS 6.61" [16.79 cm] 5.73" [14.55 cm] 8.88" [22.56 cm] 3" [7.62 cm] 34 Electronic Controls GMXFM Series 16 A GENERAL PURPOSE 1- CIRCUIT ELECTRONIC TIME CONTROLS Universal GMXFM Electronic Series Time Controls are a low-cost alternative for applications that do not require more than 16 A. The timer is mounted in a UL Type 1 indoor enclosure. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · 24-Hour or 7-day applications · Finger-safe terminals · Manual Daylight Saving Time adjustment (D20 Models) · Manual override with load status indication · Heavy-duty relay contacts for switching low or line voltage loads · Non-metallic enclosure provides space for field added contactor or other accessories Electronic Controls Enclosed Timer Module - 24-Hour or 7-Day GMXFM1D20-I-24 Model # Input Voltage # of Circuits Number of Set Points GMXFM1D20-I-24 24 VAC/VDC, 50/60 Hz 1 20 GMXFM1D20-I-120 120 VAC, 50/60 Hz 1 20 20 TITLE LISTED RATINGS Input Voltage See Model Chart Power Consumption VA 4 Switch Type SPDT NO Contacts Ballast (Fluorescent) 12 A, 120 VAC, 8 A, 240 VAC Resistive (Heater) 16 A, 277 VAC 120 VAC Timer, 120 VAC Load 208/240 VAC Timer, 208/240 VAC Load 120 VAC Timer, 24 VAC, Tungsten (Incandescent) T T 600 W, 120 VAC, 1000 W, 2401V2A0CVAC, or 240 VAC Load Pilot Duty T 360 VA, 120 VAC, 720 VA, 240 VAC 1 2 3 4 5 1 2 3 4 5 Motor TIMER COM N.O. N.C. H TO 120V LINE N NC ContaTOcLtOsAD TIMER1/2COHMP,N1.O2. 0N.VC.AC, 1 HP, 240 VAC 1 2 3 4 5 L1 TO 208/240V LINE L2 TO LOAD H TO 120V LINE N TIMER COM N.O. N.C. LOAD TO 24-240V LINE Resistive (Heater) 16 A, 277 VAC, 8 A, 24 VDC Pilot Duty Wiring Terminals 120 VAC T3im60er,V1A2,01V2A0C LVoAaCd T Screw box lug 208/240 VAC Timer, 208/240 VAC Load T Operating Temperature 1 -213°F3 - 1431°5F (-25°C - 55°C) 1 2 3 4 5 Warranty TIMER COM N.O. N.C. H TO 120V LINE 1-Year limTitOeLdOAD N TIMER L1 TO 208/240V LINE L2 COM N.O. N.C. TO LOAD Battery Backup Enclosure 7 Years 7 Years Indoor type 1 plastic Indoor type 1 plastic WIRING DIAGRAMS 120 VAC Timer, 120 VAC12L0oVaAdC Timer, 120 VAC Load T 1 2 3 4 5 TIMER H TO 120V LINE N COM N.O. N.C. TO LOAD 120 VAC Timer, 24 VAC, 120 VAC, or 240 VAC Load 120 VAC, Two Speed Fan T DIMENSIONS 6.5" [16.5 cm] 5.54" [14.1cm] 208/240 VAC Timer, 208/240 VAC Load T 120 VAC Timer, 24 VAC, 120 VAC, or 240 VAC Lo T 1 2 3 4 5 TIMER L1 TO 208/240V LINE L2 10" [25.4 cm] COM N.O. N.C. TO LOAD 8.64" [21.9 cm] 1 2 3 4 5 H TO 120V LINE N TIMER COM N.O. N.C LOAD TO 24-24 1 2 3 4 5 TIMER H TO 120V LINE N COM N.O. N.C. LOW HIGH COOL 3.74" [9.5 cm] 120 VAC,11T22w00 VVoAASCC,pToeimre2ed4r,0F2aV4AnVCALCo,ad T 1 2 3 4 5 H TO 120V LINE N TIMER COM N.O. N.C. LOAD TO 24-240V LINE 120 VAC, Two Speed Fan T 1 2 3 4 5 TIMER H TO 120V LINE N COM N.O. N.C. LOW HIGH COOL 35 Electronic Controls Electronic Controls Accessories ET9250 ET9232 ET-NF ET9100 ACCESSORIES Model # 101--00040 124ET2574 124ET2581 124ET2582 178GR10K-1 ET9100 ET9232 ET9250 ET-NF MS-101W Description Battery Holder for ET100 (SPDT) Insulator for ET Series controls (ET1115C, ET1115CR, ET1715C, ET1715CR, ET8115C and ET8115CR) (SPST) Insulator for ET Series controls (ET1105C, ET1105CR, ET1705C, ET1705CR, ET8015C and ET8015CR) (DPST) Insulator for ET Series controls (ET1125C, ET1125CR, ET1725C, ET1725CR, ET8215C and ET8215CR) Additional Separate Sensor Accessory (for Multiple Evaporator Applications) Replacement Door Assembly for ET90415-ET91615 Ethernet Module for ET90000 Upgrade or Replacement 4-Circuit Relay Board for Upgrade or Replacement of ET90415CR-ET91615CR Panels RC Snubber Noise Filter 24-277VAC/DC for Electronic Controls Commercial Grade Momentary Contact Decorator Switch, 120/277V, 15A, SPST, White 2T511GA ENCLOSURES ET-2T2926A Model # 2T2040GA 2T2331GA 2T2365GA 2T2500GA 2T2926A 2T308A 2T511GA Description Case-Indoor, Type 1 Metal, Gray Case-Outdoor, Type 3R Metal, Gray Case-Indoor, Type 1 Metal, Gray Case-Outdoor, Type 3R Plastic, Gray Case-Outdoor, Type 3R Plastic, Gray with See-Through Window Case-Indoor, Type 1 Metal, Gray Case-Outdoor, Type 3R Metal, Gray 2T308A 36 2T2500GA Electronic Controls Accessories Electronic Controls ENCLOSURE DIMENSIONS 2T2040GA 7 7/8"7 7/8" 3/8" 2 1/2"2 1/2" 2T511GA / 2RT2148/51G6A R" 1/16" 3/8" R1/8" R1/8" 5/16" 3/16" 5X 5 151X/156"11/16" (3 KNO(3CKKNOOUCTKSO) UTS) 3/8" 3 7/163" 7/16" 7 1/4"7 1/4" 3X 8 1/16" 4 1/164" 1/1661"1/166"11/16" 10 1/8" 2X 8 5/8" 1/8" 1/8" 5 1/8"5 1/8" 1 3/161" 3/16" 1 1/4"1 1/4" 3/16" 3/16" 2X 1/4" " 3" 1 7/16" 3 7/163"2T723/6156GA"/ 2T308A (2) K6N1/(O22")CKKNOOUCTKO1U3T/8"1 3/8"MOUNTING HOLES (2) KNO1C/2K"OU&T13/2/4""& 3/4" 1 7/16" 2 1/2"2 1/2"1 5/8" 1/2" & 3/4" (1 THIS SIDE & 2 11/126"11/16" (1) KN(O1)CKKKNNOOOCUKCTOKUOT UT 1/2" &13/2/41"/"2&" &33/4/4"" 3 1/43"/16" 3/16" 1 OPP. SIDE) 1/4" 8" 1 3/161" 3/16" 14" 4" 15/16"15/16" 1 7/8"1 7/8" 3 5/8" 2X 1 5/8" 5/16" 3X 8 1/1 1 1/16" 2 1/8" 11" (2) KNOCKOUT 1/2" & 3/4", 10 1/8" 918" 2X 8 5/8" 2T2500GA/ 2T2502GA/ 2T2926A 6 1/2" 114" 114" 4" (2)RK1N/O8"CKOUT 1/2" & 3/4" 2 3/4" 238" 10" 3" 6" 8 1/16" 114" 1" 11516" 1 7/16" 6 1/2" (2) KNOCKOUT 1/2"2&" 3/4" (1 THIS SIDE & 1 OPP. SIDE) 1516" 1 7/16" 1/4" 2X 1/4" MOUNTING HO 2X 1 5/8" 1 1/16" 8" 2X 8 1/2" 2 1/8" 3 5/8" (2) KNOCKOUT 1/2" & 3/4", 1 1/2" (2) KNOCKOUT 1/2", 3/4" (1 THIS SIDE & 1 OPP. SIDE) 1 1/2" (2) KNOCKOUT 1/2", 3/4" 1 5/8" 2X 1/4" MOUNTING HOLES 3 1/4" KNOCKOUT 1/2", 3/4" WANT TO KNOW MORE? Please see pages186-190 for additional wiring diagram and information on enclosures. 1 5/8" 1 1/16" 2 1/16" 37 Mechanical Time Switch Solutions Manage the runtime of fans, lights, motors, heaters, and other energy-consuming loads with our industry-leading mechanical time switch solutions. The trusted "yellow dial" is available in a range of heavy-duty options and can be integrated in a variety of commercial and industrial applications. Indoor and Outdoor Lighting Control Create dynamic, energy-efficient lighting environments by installing simple mechanical time switches. Our versatile solutions allow for 24-hour and 7-day control, as well as skip periods and manual override control. Ventilation Systems Keep fans and ventilation systems running on schedule with durable mechanical time switches. These rugged controls make it easy to create basic ON/OFF schedules in a range of commercial and industrial applications. Landscape Water Control Simplify watering schedules and promote water conservation by installing a versatile mechanical time switch. These reliable solutions make it easy to set sprinkler run times over a 24-hour or 7-day period. Pump, Machinery and Motor Controls Manage pump and light motor control schedules, including pool and spa pumps, with our range of mechanical time switch solutions. Designed for simple installation and operation, these controls provide lasting value in a wide variety of applications. Contents 24-Hour 40 24-Hour with Skip-a-Day41 24-Hour with 15-Minute Interval42 24-Hour Heavy-Duty43 7-Day 44 Panel Mount, 24-Hour or 7-Day47 Flush or Surface/DIN Rail Mount, 24-Hour48 Flush or Surface/DIN Rail Mount, 7-Day49 Electromechanical, 24-Hour or 7-Day50 Enclosed Timer Module, 24-Hour or 7-Day51 Accessories & Enclosures52 A Closer Look at the Control That Put Intermatic on the Map There are few products on the market that contractors can realistically expect to perform for decades without issue. Versatile and ever-dependable, T100 Series Mechanical Time Switches by Intermatic fit into this category. Mechanical Time Switches Mechanical Time Switches 24-Hour T101R T101M T100 Series 24-HOUR The T100 Series Mechanical Time Switch has proven it can stand the test of time. These dependable time switches can handle electrical loads up to 40 A per pole and allow for up to 12 ON/OFF operations per day. A manual override switch provides added convenience. APPLICATIONS · Timing/Scheduling ON/OFF · Indoor Lighting Control FEATURES · Direct 24-hour control of most loads · Up to 12 ON/OFF operations each day with minimum ON/OFF times of one hour · Manual override · One ON and one OFF tripper included · Can be installed in most Intermatic enclosures Model # Switch Type Input Voltage Electronic Ballast Inductive Restive (Heater) Tungsten (Incandescent) Pilot Duty Indoor type 1 metal T101 SPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T102 SPST 208-277 VAC, 60 Hz 16 A, 208-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz T103 DPST 120 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T104 DPST 208-277 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz T104-50 DPST 208-277 VAC, 50 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 50 Hz 40 A, 120-480 VAC, 50Hz 40 A, 120-277 VAC, 50 Hz 1000 VA, 120-277 VAC, 50 Hz T105 1 NO/1 NC, SPDT 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T101B SPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz Indoor/outdoor type 3R plastic T101P SPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T102P SPST 208-277 VAC, 60 Hz 16 A, 208-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz T103P DPST 120 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T104P DPST 208-277 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz Indoor/outdoor type 3R plastic with see-through door T101PCD82 SPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T103PCD82 DPST 120 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T104PCD82 DPST 208-277 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz Indoor/outdoor type 3R metal T101R SPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T102R SPST 208-277 VAC, 60 Hz 16 A, 208-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz T103R DPST 120 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T104R DPST 208-277 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz T106R 1 NO/1 NC, SPDT 208-277 VAC, 60 Hz 16 A, 208-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T1205R DPST 480 VAC, 60 Hz 16 A, 277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz N/A - Mechanism only T101M SPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T103M DPST 120 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz T106M 1 NO/1 NC, SPDT 208-277 VAC, 60 Hz 16 A, 208-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz Ratings Max Power Consumption Motor Operating Temperature 3 W 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz -40°F - 130°F (-40°C - 54°C) 40 Wire Size Warranty #8 AWG 1-Year limited For enclosure options and dimensions, see pages 186-190 For accessories and replacement parts, see pages 52-53 Mechanical Time Switches Mechanical Time Switches 24-Hour with Skip-a-Day T170, T1400, and T1800 Series 24-HOUR WITH SKIP-A-DAY Similar to the T100 Series, these time switches can also handle electrical loads up to 40 A per pole. The T170 Series Time Switches allow for up to 10 ON/OFF settings per day, but give you the additional capability of skipping days in which the loads may not be needed. Each time switch will come with one set of ON/OFF trippers as well as three skipper screws to omit the schedule for at least three days. APPLICATIONS · Indoor Lighting Control · Outdoor Lighting Control · Timing/Scheduling ON/OFF FEATURES · Controls loads up to 40 A per pole · Direct 24-hour control of most loads · Up to 10 ON/OFF operations each day · Minimum ON/OFF times of one hour · Manual override · One ON and one OFF tripper and three day-skipper screws included T171CR Model # Switch Type Input Voltage Electronic Ballast Indoor type 1 metal T171 SPST 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T172 SPST 208-277 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T173 DPST 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T174 DPST 208-277 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T175** 1 NO/1 NC 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T176** 1 NO/1 NC 208-277 VAC, 60 Hz 16 A, 277 VAC, 60 Hz Outdoor type 3R metal T171CR SPST 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T173R DPST 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T173CR DPST 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T174R DPST 208-277 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T1471BR* 4-PST 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T1471BCR* 4-PST 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T1472BR* 4-PST 208-277 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T1475BR* 4-PST 480 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T1871BR* 2 NO/2 NC 120 VAC, 60 Hz 16 A, 277 VAC, 60 Hz T171CR, T173CR, T174CR, T1471BCR are models with Carry-Over *Separate clock motor terminals for switching circuits not on line voltage. **Can be wired as SPDT. Can be wired as DPDT. Inductive 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz Restive (Heater) Tungsten (Incandescent) Pilot Duty 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz Ratings Max Power Consumption 3 W Motor T170 Series 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz Motor T1400 & T1800 Series Single Phase 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz Three Phase 7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz Wire Size #8 AWG Enclosure Dimensions H x W x D Metal Indoor 7.875" x 5.125" x 3.4375" (200 mm x 130.2 mm x 87.3 mm) Metal Outdoor 10.125" x 6.5" x 3.625" (257.2 mm x 165.1 mm x 92.1 mm) Operating Temperature -40°F - 130°F (-40°C - 54°C) For enclosure options and dimensions, see pages 186-190 For accessories and replacement parts, see pages 52-53 41 Mechanical Time Switches Mechanical Time Switches 24-Hour with 15-Minute Interval T1905P Ratings Resistive (Heater): 20 A, 125-480 VAC, 60 Hz Motor 1/2 HP, 125 VAC, 60 Hz, 1 HP, 250 VAC, 60 Hz Max Power Consumption 3 W Wire Size #12 AWG Enclosure Dimensions H x W x D Metal Indoor 7.875" x 5.125" x 3.4375" (200 mm x 130.2 mm x 87.3 mm) Metal Outdoor 10.125" x 6.5" x 3.625" (257.2 mm x 165.1 mm x 92.1 mm) Plastic Indoor/Outdoor 10" x 6.5" x 4" (254 mm x 165.1 mm x 101.6 mm) Warranty 1-Year limited Operating Temperature -40°F - 130°F (-40°C - 54°C) For enclosure options and dimensions, see pages 186-190 For accessories and replacement parts, see pages 52-53 T1900 Series & T1970 Series 24-HOUR WITH 15-MINUTE INTERVAL This series of mechanical time switches offers more flexible scheduling capabilities by offering 15-minute intervals. These units also come with trippers that slide in or out easily for fast and accurate settings. All units can control up to 20 A of electrical load and have a single pole, double throw switch. APPLICATIONS · Timing/Scheduling ON/OFF · Indoor Lighting Control FEATURES · Provides up to 96 operations (48 ON/48 OFF) every 24 hours ·Models with skipper wheel allow for operations to be omitted on selected days of the week · 15-minute intervals · Captive trippers slide in and out of dial for fast, accurate setting Model # Switch Type Input Voltage Indoor type 1 metal T1905 SPDT 125 VAC, 60 Hz T1905E SPDT 480 VAC, 60 Hz T1906 SPDT 208-277 VAC, 60 Hz T1975 SPDT 125 VAC, 60 Hz T1975E SPDT 480 VAC, 60 Hz T1976 SPDT 208-277 VAC, 60 Hz Outdoor type 3R metal T1975ER SPDT 480 VAC, 60 Hz T1975R SPDT 125 VAC, 60 Hz T1976R SPDT 208-277 VAC, 60 Hz Indoor/outdoor type 3R plastic T1905P SPDT 125 VAC, 60 Hz Skipper Wheel Not Included Not Included Not Included 24 Hour 24 Hour 24 Hour 24 Hour 24 Hour 24 Hour Not Included 42 Mechanical Time Switches T1905HD & T1975HD 24-HOUR HEAVY-DUTY These heavy-duty time switches are designed to handle the toughest environments and have fully encapsulated motors to prevent dust or debris from entering the motor. The ON/OFF trippers are permanently attached to the metal dial to avoid the accidental loss of a tripper. These time switches offer 15-minute intervals, providing up to 96 operations each day. APPLICATIONS · Timing/Scheduling ON/OFF · Indoor Lighting Control FEATURES · H eavy-duty metal dial and metal enclosure withstands the most punishing environmental conditions ·Models with skipper wheel allow for operations to be omitted on selected days of the week · Easy-to-set trippers rotate in/out for fast, accurate setting · Up to 96 operations (48 ON/48 OFF) every 24 hours · 15-minute intervals between events · Fully encapsulated motor with protected gears Model # Switch Type Indoor type 1 metal T1905HD SPDT T1975EHD SPDT Outdoor type 3R metal T1905HDR SPDT T1975HDR SPDT T1975EHDR SPDT N/A - Mechanism only T1905HDM SPDT Input Voltage Skipper Wheel 125 VAC, 60 Hz 480 VAC, 60 Hz Not Included 24 Hour 125 VAC, 60 Hz 125 VAC, 60 Hz 480 VAC, 60 Hz Not Included 24 Hour 24 Hour 125 VAC, 60 Hz Not Included Mechanical Time Switches 24-Hour Heavy-Duty T1905HD Ratings Resistive (Heater): 20 A, 125-480 VAC, 60 Hz Motor 1/2 HP, 125 VAC, 60 Hz, 1 HP, 250 VAC, 60 Hz Max Power Consumption 3 W Wire Size #12 AWG Enclosure Dimensions H x W x D Metal Indoor 7.875" x 5.125" x 3.4375" (200 mm x 130.2 mm x 87.3 mm) Metal Outdoor 10.125" x 6.5" x 3.625" (257.2 mm x 165.1 mm x 92.1 mm) Warranty 1-Year limited Operating Temperature -40°F - 130°F (-40°C - 54°C) For enclosure options and dimensions, see pages 186-190 For accessories and replacement parts, see pages 52-53 KEEP THE PIPELINE ON-TIME Choose the T1905HD or T1975HD Heavy-Duty Timer for seamless ON/OFF control in oil field time switch applications. The rugged and versatile controls offer unique features, including higher input voltage ratings and an encapsulated motor, which help them perform in harsh outdoor conditions. 43 Mechanical Time Switches Mechanical Time Switches 7-Day T7401B T7000B Series 7-DAY These 7-Day Mechanical Time Switches offer the capability of having a different schedule for each day of the week. They can handle up to 40 A of electrical loads per circuit and have separate terminals for powering the clock motor. These time switches can handle up to four loads per clock, providing a single control for easier installation. Each time switch comes with 7 ON and 7 OFF trippers, allowing for at least one ON/OFF operation each day. APPLICATIONS · Indoor Lighting Control · Timing/Scheduling ON/OFF FEATURES · Different ON/OFF programs each day of the week · True 7-day load control with minimum ON/OFF time of 3 1/2 hours · Separate clock motor terminals for switching loads not on line voltage · Carry-over automatically rewinds when power resumes · Minimum of 16-hour carry-over for maintaining preset schedules during power failures ·Available with Type 3R rated outdoor metal enclosure or Type 1 rated indoor metal in gray finish with separate grounding terminal Ratings Electronic Ballast (LED) 16 A, 277 VAC, 60 Hz Tungsten (Incandescent) 40 A, 120-277 VAC, 60 Hz Resistive (Heater) 40 A, 120-480 VAC, 60 Hz Inductive 40 A, 120-277 VAC, 60 Hz Pilot Duty 1000 VA, 120-277 VAC, Per Pole, 60 Hz Motor Single-Phase 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz Three-Phase 7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz Wire Size #8 AWG Enclosure Dimensions H x W x D Indoor Metal 13.125" x 9" x 3.75" (333.3 mm x 228.9 mm x 95.25 mm) Warranty 1-Year limited Operating Temperature -40°F - 130°F (-40°C - 54°C) For enclosure options and dimensions, see pages 186-190 For accessories and replacement parts, see pages 52-53 Model # Switch Type Input Voltage Indoor type 1 metal T7401B 4-PST/NO 120 VAC, 60 Hz T7402B 4-PST/NO 208-277 VAC, 60 Hz T7801B* 2 NO/2 NC 120 VAC, 60 Hz T7802B* 2 NO/2 NC 208-277 VAC, 60 Hz Indoor type 1 metal T7401BC 4-PST/NO 120 VAC, 60 Hz T7402BC 4-PST/NO 208-277 VAC, 60 Hz T7801BC* 2 NO/2 NC 120 VAC, 60 Hz *Can be wired as (2) DPDT. Note: All models have separate clock motor terminals for switching circuits not on line voltage. They may be used with 24 V systems if wired in accordance with NEC regulations. 44 Mechanical Time Switches T2000 Series 7-DAY These compact 7-Day Mechanical Time Switches offer the capability of having a different schedule for each day of the week. They can handle up to 20 A of resistive loads and up to six ON/OFF settings per day. APPLICATIONS · Timing/Scheduling ON/OFF · Indoor Lighting Control FEATURES · Minimum 2-hour timing intervals · Up to 42 ON/OFF operations per week · Type 1 rated metal indoor enclosure Mechanical Time Switches 7-Day Model Indoor type 1 metal T2005 T2006 Switch Type SPDT SPDT Input Voltage 120 VAC, 60 Hz 208-277 VAC, 60 Hz T2005 Ratings Resistive (Heater) 20 A, 125, 208-277 VAC, 60 Hz Motor 1/2 HP, 125 VAC, 60 Hz, 1 HP, 250 VAC, 60 Hz Wire Size #12 AWG Enclosure Dimensions H x W x D 7.875" x 5.125" x 3.4375" (200 mm x 130.2 mm x 87.3 mm) Warranty 1-Year limited Operating Temperature -40°F - 130°F (-40°C - 54°C) For enclosure options and dimensions, see pages 186-190 For accessories and replacement parts, see pages 52-53 45 Mechanical Time Switches Mechanical Time Switches Panel Mount, 24-Hour or 7-Day THE 121 161 THE 121 161 1H,120V,MECH SRFC/DIN MNT THE 121 161 is a DIN rail time switch from Intermatic that allows hourly switching cycle commands. Setting time is easy by grasping and rotating the clock dial. Time and switching times can be checked at a glance, resulting in versatile application possibilities, such as motor cycling, generator exercising, or any other applications requiring hourly cycling activities. APPLICATIONS · Greenhouse Misting · Aeration · Air Movement & Ventilation · Water Circulation · Pool Pump FEATURES · 1.25 minute resolution 133--SER018 133--SER018 · Up to 24 ON/OFF times per hour · Captive tripper levers · SPDT 16 A switch · DIN rail or enclosure mounting · On-AUTO-OFF Override switch · Synchronous drive Ratings Switch Type Resistive Tungsten Wiring Connections Operating Humidity Warranty SPDT, Isolated Contacts 16 A, 250 VAC 750 W, 250 VAC Screw terminal accepts up to #12 AWG wire 0-95% RH, Non-condensing 1-Year limited Model # Input Voltage THE 121 161 120 VAC, 60 Hz DIMENSIONS Mounting DIN Rail Total Cycle Time Timing Interval per Tripper 1 hr 1.25 min FM1 SERIES FM1 Series Electromechanical Timer Modules are designed with up to 21 Amp switching capability for control of a wide variety of end use applications including heating, ventilation, air conditioning, refrigeration, pool and spa, lighting and security. These versatile timers come in 12 or 24 VAC/DC or 120 and 208/240 VAC 50/60 Hz. They are available with 24-hour or 7-day scheduling. 46 Mechanical Time Switches FM1 Series 21 A, 1-CIRCUIT, PANEL MOUNT TIMER MODULES The FM1 series timer modules are designed to be integrated inside of a machine control panel, circuit board, or other equipment. They are a simple and low cost alternative for applications that do not require more than 21 A or 2 HP, 240 VAC. The FM1 is designed for 24-hour or 7-day control or overriding a functional typical state of a heating, ventilation, refrigeration, lighting, security, or pump system. The FM1 series is ideal for 12, 24 VAC/ VDC,120 or 208/240VAC single-phase general applications. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · 21 A SPDT Switch · C aptive trippers with 15-minute intervals on 24-hour models and 2-hour intervals on 7-day models · 72-hour carry-over battery backup on Q models · Noise immune ideal for robust applications · Synchronous drive or quartz drive Q models with self-recharging battery backup · True clock face, easy-to-set · Available with or without override · Compact size · Clear plastic cover (DC-FME-A), sold separately · Standalone or with indoor/outdoor enclosure, sold separately Model # Synchronous Model # Quartz Input Voltage Override Min On/Off Time 24 hrs FM1STUZ-24U FM1QTUZ-24U* 24 VAC, 60 Hz No 15 min FM1STUZ-120U FM1QTUZ-120U* 120 VAC, 60 Hz No FM1STUZ-240U 208/240 VAC, 60 Hz No FM1STUZH-24U FM1QTUZH-24U* 24 VAC, 60 Hz Yes 15 min FM1STUZH-120U FM1QTUZH-120U* 120 VAC, 60 Hz Yes FM1STUZH-240U 208/240 VAC, 60 Hz Yes 7 days FM1QWUZ-240U* 208/240 VAC, 50/60 Hz No 2 hrs FM1SWUZ-120U FM1QWUZH-120U* 120 VAC, 60 Hz Yes 2 hrs *Quartz models operate at 12-24 VAC/VDC, 120, or 208/240 VAC and are Title 20 listed. WIRING DIAGRAMS Override Mode 3-Way Manual Override Mode Ove3r-rWidaeySMwaintcuhal Override Switch ON ON M M~ ~ 5 5 4 4 3 3 2 2 1 1 ONON OFFOFF OFF OFF 5 5 44 33 5 5 44 33 543 543 MM~~ 2 11 M ~ 22 11 M M~ ~ 21 21 I = permanent ON I = =pearmutaonmenattiOcN 0==auptoemrmataicnent OFF 0 = permanent OFF II 00 Switch Configuration M 5 4 3 2 1 NC NO COM INPUT Mechanical Time Switches Panel Mount, 24-Hour or 7-Day FM1QTUZ-24U LR3730 #E10694 Ratings Tungsten (Incandescent) Resistive (Heater) Power Consumption Switch Type Motor Battery Backup Option Wiring Connections Warranty Operating Temperature Compliant 2002/95/EC 20 TITLE LISTED 1350 W, 120 VAC 21 A, 250 VAC 1 Va SPDT 1 HP, 120 VAC; 2 HP, 250 VAC 72-hour Carry-over, Battery, Self-recharging "Q" Models Only 1/4" Quick connect terminals 1-Year limited -40°F - 185°F (-40°C - 85°C) DIMENSIONS FM1 Panel Mount Series II 00 22.1.133"" [5[544mmmm]] 22.3.366"" [6[600mmmm]] 22.4.444"" [6[622mmmm]] 00.8.811"" [2[211mmmm]] 11.2.255"" [3[322mmmm]] 47 Mechanical Time Switches Mechanical Time Switches Flush or Surface/DIN Rail Mount, 24-Hour MIL72ESTUZ-120 MIL72ASTUZ-120 LR3730 #E10694 Ratings Tungsten (Incandescent) Resistive (Heater) Power Consumption 24 VAC 120 VAC 208/240 Switch Type Motor Battery Backup Option Wiring Connections Warranty Operating Temperature Compliant 2002/95/EC 20 TITLE LISTED 1350 W, 120 VAC 21 A, 250 VAC 0.1 Va 0.5 Va 1 Va SPDT 1 HP, 120 VAC; 2 HP, 250 VAC 72-hour Carry-over, Battery, Self-recharging "Q" Models Only 1/4" Quick connect terminals 1-Year -40°F - 185°F (-40°C - 85°C) DIMENSIONS 2.83" [72 mm] MIL72E Flush Mount with Clear Dust Cover I 0 With clear dust-cover 2.60" [66 mm] MIL72A Surface Mount/DIN Rail Mount with Clear Dust Cover With clear dust-cover 2.83" [72 mm] .80" [20.5 mm] 1.36" [34.5 mm] 2.06" [52 mm] 1.56" [39.5 mm] I 0 4.00" [102.5 mm] MIL72 Series, 24-Hour 21 A, 1-CIRCUIT, 24-HOUR TIMER MODULES The MIL72 series time switches are designed to be mounted inside a control panel and can accommodate surface/DIN rail or flush panel mounting. The MIL72 series is a light duty commercial time switch for 12-24 VAC/VDC, 120 or 208/240 VAC single-phase applications. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment -· Generator Exercising FEATURES · 21 A SPDT switch · Synchronous drive or quartz drive (Q Models) with self-recharging battery backup · 72-hour carry-over battery backup on Q models · Captive trippers with 15-minute intervals · Available with or without override · True clock face, easy-to-set · Surface/DIN rail or flush mount · Clear plastic dust cover · Compact size Model # Flush Mount (MIL72E) Model # Surface Mount/DIN Rail (MIL72A) Input Voltage MIN ON/OFF Override Time Synchronous MIL72ESTUZ-120 MIL72ASTUZ-120 120 VAC, 60 Hz 15 min No MIL72ESTUZ-240 MIL72ASTUZ-240 208/240 VAC, 60 Hz 15 min No MIL72ASTUZH-24 24 VAC, 60 Hz 15 min Yes MIL72ESTUZH-120 MIL72ASTUZH-120 120 VAC, 60 Hz 15 min Yes MIL72ASTUZH-240 208/240 VAC, 60 Hz 15 min Yes Quartz MIL72EQTUZ-24* 12/24 VDC, 12/24 15 min Yes VAC, 50/60 Hz MIL72EQTUZH-120* MIL72AQTUZH-120* 120 VAC, 50/60 Hz 15 min Yes MIL72AQTUZ-240* 208/240 VAC, 15 min No 50/60 Hz *Quartz Models operate on 12-24 VAC/VDC, 120 or 208/240 VAC, and 50/60 Hz and are Title 20 listed. WIRING DIAGRAMS 12-24 VAC/VDC & 120 VAC application Timer T 3 4 5 1 2 COM N.O. N.C. 120 VAC H N or +(DC) or -(DC) 12-24 VDC (Quartz Only) LOAD 2.60" [66mm] 1.50" [38 mm] 48 Mechanical Time Switches MIL72 Series, 7-Day 21 A, 1-CIRCUIT, 7-DAY TIMER MODULES The MIL72 series time switches are designed to be mounted inside a control panel and can accommodate surface/DIN rail or flush panel mounting. The MIL72 series is a light duty commercial time switch for 12-24 VAC/VDC, 120 or 208/240 VAC single-phase applications. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · 21 A SPDT switch · Synchronous drive or quartz drive (Q Models) with self-recharging battery backup · 72-hour carry-over battery backup on Q models · Captive trippers with 2-hour intervals · Available with or without override · True clock face, easy-to-set · Surface/DIN rail or flush mount · Clear plastic dust cover · Compact size Model # Flush Mount (MIL72E) Synchronous MIL72ESWUZH-120 MIL72ESWUZH-240 Quartz MIL72EQWUZH-120 Model # Surface Mount/DIN Rail (MIL72A) MIL72ASWUZH-120 MIL72AQWUZH-120 Input Voltage 120 VAC, 60 Hz 208/240 VAC, 60 Hz 120 VAC, 50/60 Hz MIN ON/OFF Time 2 hrs 2 hrs 2 hrs Override Yes Yes Yes *Quartz Models operate on 12-24 VAC/VDC, 120 or 208/240 VAC, and 50/60 Hz and are Title 20 listed. WIRING DIAGRAMS 12-24 VDC & 120 VAC application Timer T 3 4 5 1 2 COM N.O. N.C. 120 VAC H N or +(DC) or -(DC) 12-24 VDC (Quartz Only) LOAD Mechanical Time Switches Flush or Surface/DIN Rail Mount, 7-Day MIL72ESWUZH-120 MIL72AQWUZH-120 LR3730 #E10694 Ratings Tungsten (Incandescent) Resistive (Heater) Power Consumption 120 VAC 208/240 Switch Type Motor Battery Backup Option Wiring Connections Warranty Operating Temperature Compliant 2002/95/EC 20 TITLE LISTED 1350 W, 120 VAC 21 A, 250 VAC 0.5 Va 1 Va SPDT 1 HP, 120 VAC; 2 HP, 250 VAC 72-hour Carry-over, Battery, Self-recharging "Q" Models Only Screw terminal accepts up to #12 AWG wire 1-Year limited -4°F - 131°F (-20°C - 55°C) MIL72E Flush Mount with Clear Dust Cover MIL72A Surface Mount with Clear Dust Cover DIMENSIONS 2.83" [72 mm] With clear dust-cover I 0 With clear dust-cover 2.83" [72 mm] 2.60" [66 mm] .80" [20.5 mm] 1.36" [34.5 mm] 2.06" [52 mm] 1.56" [39.5 mm] I 0 4.00" [102.5 mm] 2.60" [66mm] 1.50" [38 mm] 49 Mechanical Time Switches Mechanical Time Switches Electromechanical, 24-Hour or 7-Day GM40AV Series 40 A AUTO-VOLTAGE GENERAL PURPOSE TIME SWITCH GM40AV Captive Trippers can't be lost The GM40AV Time Switch is a universal, electromechanical time switch designed for general purpose residential and commercial applications. The robust 40 A time switch automatically detects the input voltage without the use of a DIP switch or selector pins. The time switch automatically selects any voltage between 120-277 VAC. The mechanism is mounted in a compact UL Type 3R outdoor enclosure and can also be easily retrofitted into other Intermatic enclosure types. The time switch features a DPDT switching configuration standard (i.e. two normally open and two normally closed contacts). APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · Auto-voltage selection 120 VAC-277 VAC · Captive trippers - trippers cannot be lost · 40 A rating · Self-recharging battery backup, "Q" models feature 72-hour carry-over · Power and status LED indicators · 24-Hour or 7-day models available · Up to 48 ON/OFF operations per 24-hour period or 42 ON/OFF operations per week on "W" models · DPDT switching configuration standard (2 NO and 2 NC Contacts) · Manual three-way ON/OFF/AUTO override switch · Easy-to-read clock face · Type 3R outdoor enclosure Model # Input Voltage Switch Type GM40AV Auto Voltage 120-277 VAC, 60 Hz DPDT GM40AV-Q* 120-277 VAC, 50/60 Hz DPDT GM40AV-W 120-277 VAC, 60 Hz DPDT GM40AV-QW* 120-277 VAC, 50/60 Hz DPDT *Q models are Title 20 listed. Enclosure Indoor/outdoor type 3R plastic Indoor/outdoor type 3R plastic Indoor/outdoor type 3R plastic Indoor/outdoor type 3R plastic Battery Backup No 72-hour Carry-over, Battery, Self-recharging No 72-hour Carry-over, Battery, Self-recharging Timing 24 hour, 15 min Intervals 24 hour, 15 min Intervals 7 day, 2 hours Intervals 7 day, 2 hours Intervals #E10694 #E10694 Compliant 2002/95/EC 20 TITLE LISTED patent #6,563,237 Ratings NO Contacts Tungsten (Incandescent) 15 A, 120 VAC Resistive (Heater) 40 A, 120-277 VAC Ballast (Fluorescent) 30 A, 120 VAC; 20 A, 277 VAC Pilot Duty 300 VA, 120-240 VAC Motor 1 HP, 16 FLA, 90 LRA @120 VAC; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC NC Contacts Tungsten (Incandescent) 2 A, 120 VAC Resistive (Heater) 30 A, 120-277 VAC Ballast (Fluorescent) 10 A, 277 VAC Motor 1 HP, 12 FLA, 30 LRA @ 120 VAC; 2 HP, 10 FLA, 30 LRA @ 240 VAC Power Consumption 7 Va Wiring Terminals Screw box lug Electrical Life 50,000 operations at full load Operating Humidity 0-95% RH, Non-condensing Warranty 1-Year limited Operating Temperature -40°F - 131°F (-40°C - 55°C) ENCLOSURE DIMENSIONS 6.61" [16.79 cm] 5.73" [14.55 cm] GM40AV Product Dimensions 3" [7.62 cm] WIRING DIAGRAM TIMER T L 1 L 2/N NC NO COM NC 2 NO 2 COM2 L N LOAD #1 LOAD #2 120/277 VAC 8.88" [22.56 cm] TIMER T L 1 L 2/N NC NO COM NC 2 NO 2 COM2 L1 L2 LOAD #1 208/240 VAC 50 Mechanical Time Switches Enclosed Timer Module, 24-Hour or 7-Day Mechanical Time Switches GMX Series 21 A, GENERAL PURPOSE, 1-CIRCUIT ELECTRONIC TIME SWITCHES The GMX series time switches are universal mechanical time switches. They are a low cost alternative for applications that do not require more than 21 A or 2 HP @ 240 VAC. The timer is mounted in a UL Type 1 indoor or Type 3R outdoor plastic enclosure. The GMX is a light-duty commercial time switch ideal for 24, 120 or 208/240 VAC single-phase general applications. APPLICATIONS · Refrigeration Merchandiser · Air Movement & Ventilation · Aeration · Septic Treatment · Generator Exercising FEATURES · 21 A SPDT Switch · UL Type 1 indoor or Type 3R outdoor plastic enclosure · Manual 3-way override · Captive trippers with 15-minute intervals on 24-hour models and 2-hour intervals on 7-day models · True clock face, easy to set · Finger-safe terminals · Enclosure provides space for field-added contactor or other accessories · Synchronous drive or quartz drive ("Q" models) with self-charging battery backup GMXST-O-120 Model # Model # Quartz Voltage Min On/Off Times Enclosure Synchronous 72-hour Carry-over, Battery, Self-recharging 24 hrs GMXST-I-120 ** 120 VAC, 60 Hz 15 min Indoor type 1 plastic GMXST-I-240 ** 208/240 VAC, 60 Hz 15 min Indoor type 1 plastic GMXST-O-120 GMXQT-O-120* 120 VAC, 50/60 Hz 15 min Outdoor type 3R plastic 7 days GMXSW-I-120 ** 120 VAC, 60 Hz 2 hrs Indoor type 1 plastic *Quartz models operate on 12-24 VAC/VDC, 120 or 208/240VAC, and 50/60 Hz and are Title 20 listed. **Considered upon request 120 V Timer and Load 208/240 V Tim WIRING DIAGRAMS #E10694 Compliant 2002/95/EC Ratings Tungsten (Incandescent) Resistive (Heater) 20 TITLE LISTED 12012V0TVimTeimr aenr danLdoaLdoad TT 1350 W, 120 VAC, 60 Hz 21 A, 250 VAC, 60 Hz 1 1 2 2 3 3 4 4 5 5 Typical Wiring for GMX ST eries T 20280/28/42040VVTiTmimerear nadndLoLaodad TT 1 1 2 2 3 3 44 55 112200VVTTimimeerr 2244--22440 V Load 1 2 34 5 12 TIMER TTCOM NO NC H L1 TIMER CO TO 120 V LINE TO LOAD TO 208/240 V LINE N 11 22 33 4 55 L2 Motor Switch Type Operating Humidity 1 HP, SPDT 120 VACHNT;O2 HNTH1PO2,0215V200TLVIVIMANTCELEIIMRNEERCOCMOMNOTNOOTNLOCONLACODADTOTO2LL0212LL8021/284/204V0TVLIITMNLIIEMENREER COCOMM NNOO NNCC TOTOLOLOAADD 0 to 95%, Non-condensing HH TTIMIMEERR TTOO112200VVLLININEE NN CCOOMM NNOO NNCC LLOOAADD TTOO 2244--224400 VV LLIINNEE Battery Backup Option Wiring Connection 72-hour Carry-over, Battery, Self-recharging "Q" Quartz Models Screw terminal accepts up to #12 AWG wire 120 V Timer and Load T 2081/22040V VTwToimSepreaenddFLaonad TT 120 V Timer T Warranty 1-Year limited 12012V0TVwTowSopeSepdeeFdaFnan 12 Operating Temperature -40°F - 185°F (-40°C - 85°C) T T TIMER H ENCLOSURE DIMENSIONS 6.5" [16.5 cm] 5.54" [14.1cm] TO 120 V LINE 1 12 2 3 344 55 N H H TIMTEIMRERCOCMOMNONONCNC TO 120 V LINE TO N120 V LINE N LOW LOHWIGH HIGCHOM COM 3 COM 45 NO NC TO LOAD 1 1 2 2 3 3 44 55 12 TO 2L018HT/O24102V0TVLIITMNLIEIMENREER L2 N COCOMMNNOO NNCC TO LOAD LOW H HCIGOTHMON120 V TIMER LINE 120 V Two Speed Fan 10" [25.4 cm] 8.64" [21.9 cm] 3.74" [9.5 cm] T 1 2 34 5 TIMER H TO 120 V LINE N COM NO NC LOW HIGH COM 51 Mechanical Time Switches Mechanical Time Switches Accessories & Enclosures ACCESSORIES Model # 107TN221 107TN222 107T73 124T1952 119T86A 124T2097 124T2411A 124T905 130T1042 131T68GA 133T700A 133T773A 143T138 156T1948A 156T1954A 156T1950AD12 124T1954 156T1978AD12 156T2548A 156T3085A 156T3230A 22T338GR WG1570-10 WG1573-10D WG1574-10 WG1603-11D Description Red (OFF) tripper for TN, PB, TB Series, P1101, P1131, P1161, P1261P, AL300TPWS, AL600TPWS and AL900TPWS Turquoise (ON) tripper for TN, PB, TB Series, P1101, P1131, P1161, P1261P, AL300TPWS, AL600TPWS and AL900TPWS Replacement Day Wheel Pins for T8800 and R8800 Series Insulator for Double-Pole Time Switch (T103, T104, T105, T173, T174, T175, T176, T185, WH40) 24 VAC 20 VA Transformer, with #10 Ring Terminals Insulator for R8806P101C, T8805P101C, T8845PV Insulator for Mechanical Time Switches - 10 Pack Insulator for T1905HDM, T1975EHDM, T1975HD, T1976, T1975, T1975ER, T1905 Grounding Terminal Bar 125 VAC, 60 Hz Motor and Carry-over for T7400BC and T800BC Series Micro Switch for T8800 and R8800 Series Replacement Snap Switch for C8800 Series Relay Kit, DPST, 3 HP, 240 VAC (S) Trippers for T170, T1400, T1800 Series Includes 1 ON, 1 OFF, and 1 ON with Skipper Extension 14 Skipper Pins for R8800, and T8800 Series 12 Bags of 156T1950A Trippers for T1900, T2000, C8800, R8800, and T8800 Series Insulator for T101B with Independent Motor Wiring 12 Pack of 156T1978A Trippers for T100, T7000, and WH40 7 Sets of ON/OFF Trippers for T7400 and T7800 Series Skipper Screws for T170 Series, T1400 Series, and T1800 Series Trippers (1) Set (ON/OFF/ON Cutout) for WH Series Mounting Bracket for Intermatic Standardized Timer Mechanisms WG1570-10 208-277 VAC, 60 Hz Motor for T102, T104, T106, T172, T174, WH40 WG1574-10 WG1603-11D Model # WG190-15D WG433-20D WG436-20 WG630D WG720-10D 133T1115A 133T701A 156T2978A 124T2058 124T907A 107T119 156T1950A WG1571-10D WG1576-10D WG1574-10D 124T1948 156T3225A 133T698A 156T1957A 143T302A WG1570-10D WG733-14D WG1600-11 WG730-14D 156T1978A 124T1953 WG736-14 WG430-20D WG1571-10 Description MOTOR-BOXED,125V 60HZ MOTOR-BOXED,125V 60HZ WG436-20 WG630D MOTOR-BOXED,125V 60HZ Toggle Switch for T8800 and R8800 Series Replacement Snap Switch for T1900 and T2000 Series Package Accessory Trippers Insulator for T1905, T1906, T2006, T2005, C8815, C8825, C8835, C8845, C8855, C8865, C8866 Insulator Assembly (S001) Tripper (Silver) for T8800 and R8800 Series (Day Skipper) Set of 12 Trippers for T1900, T2000, C8800, R8800 and T8800 Series MOTOR-BOXED,125V 50HZ WG1576-10D MOTOR-BOXED,250V 50HZ Insulator for Single-Pole Time Switch (T101, T102, T171, T172) Trippers (2) Sets (ON/OFF) for T7000, WH Series (With ON/OFF Markings) Replacement Snap Switch for T1970 Series Skipper Screws (3 per package) Relay Kit, DPST, 3 HP, 120 VAC Assembly (S001) 125 VAC, 60 Hz Motor for T101, T103, T105 208-277 VAC, 60 Hz Motor for R8800, T1900, T1970, and T8800 Series WG1600-11 125 VAC, 60 Hz Motor for R8800, T1900, T1970, and T8800 Series Extra/replacement trippers 1 ON and 1 OFF Insulator for 4PST Time Switch WG736-14 MOTOR-BOXED,125V 60HZ WG1571-10 52 Mechanical Time Switches 2T511GA ENCLOSURES 2T2926A Model # 2T2040GA 2T2331GA 2T2365GA 2T2500GA 2T2926A 2T308A 2T511GA Mechanical Time Switches Sub-Category Product Description Case-Indoor, Type 1 Metal, Gray Case-Outdoor, Type 3R Metal, Gray Case-Indoor, Type 1 Metal, Gray Case-Outdoor, Type 3R Plastic, Gray Case-Outdoor, Type 3R Plastic, Gray with See-Through Window Case-Indoor, Type 1 Metal, Gray Case-Outdoor, Type 3R Metal, Gray 2T308A ENCLOSURE DIMENSIONS 2T2040GA 2T2500GA 2 1/2"2 1/2" R1/16R"2T15/1116G"A / 2T2485GA 5X 5 151X/156"11/16" 3/8" 3/8" R1/8" R1/8" (3 KNO(3CKKNOOUC5T/1KS6"O) U5T/1S6") 3/16" 3/16" 3/8" 3/8" 7 7/8"7 7/8" 7 1/4"7 1/4" 3 7/163" 7/16" 3X 8 1/163"X 8 1/16" 4 1/164" 1/1661"1/166"11/16" 10 1/8" 10 1/8" 2X 8 5/8"2X 8 5/8" UT & 3/16" 3" 7/16" 1/8" 1/8" 2X 1/42"X 1/4" 5 1/8"5 1/8" 1 3/161" 3/16" 1 1/4"1 1/147"/16" 6 1/2" 631//21"6" 1 (172//)21K"6N"&O3C/(142K/")2OK"UN&TO3C/4K"OUT 31/17/616"" MOUNTIMNGOUHNOTLIENSG HOLES 1 7/16" 1 5/8" 1 5/8" 3" (2) KN(O2)CKKNOOUCTKO1U3T/8"1 1/2" &13/2/4""& 3/4" 3/8" 2 (1 THIS S(1IDTEH&IS 1 OPP. S1IDOEP) P. 1/2"2 1/2" SSIIDD(1EE1)/&)2K" N&(1O13/)C2/4K1"K/"4N&O" OU3C/T14K/"4"OUT 3 1/4" 3 7/1623"T275/0106G"A/ 2T2502GA/ 2T2926A 2 11/126"11/16" 3/16" 3 5/8" 3/3156/8""2T2365GA / 2T308A 2X 1 5/8"2X 1 5/8" 15/16"15/6116/"2" 1 3/161" 3/16"R1/8" 4" 1 7/8"1 7/8" 2 3/4" 1 1/16" 1 1/16" 2 1/8" 2 1/8" (2) KNOC(2K)OKUNTOCKOUT 1/2" & 3/14/"2," & 3/4", 8" KNOCKOKUNTOCKOUT 1/2" & 3/14/"2" & 3/4" 3 1/4" 10" " 8 1/16" 8" 11" 2X 8 1/2" 2X 1/4" 1 1/2" (2) KNOCKOUT 1/2", 3/4" (1 THIS SIDE & 1 OPP. SIDE) 1 1/2" (2) KNOCKOUT 1 5/8" 3 1/4" MOUNTING HOLES KNOCKOUT 1/2", 3/4" 1/2", 3/4" 114" WANT TO KNOW MORE 1 1/16" Please see pages 186-190 for additional wiring diagrams and information on enclosures. 1 5/8" 2 1/16" 3" 6" 114" (2) KNOCKOUT 1/2" & 3/4" 238" 114" 53 1" Specialty Time Switch Solutions Give unique projects a boost with our wide selection of specialty time switches. Common applications include irrigation and misting systems, water heaters, feeding equipment, processing equipment and other agricultural needs. Irrigation and Misting System Automate daily or weekly watering schedules with a mechanical or electronic specialty time switch. Our versatile solutions are quick to install and adjust throughout the season as watering needs change. Water Heater Controls Reduce utility costs with a simple yet effective water heater timer. Electronic solutions like the EH40 allow users to create daily ON/OFF schedules to maximize efficiency while always keeping hot water at the ready. Ventilation Systems Keep fans and ventilation systems operating on schedule with dynamic solutions, such as our percentage cycle time switches. These handy controls improve energy efficiency and promote long-term performance. Percentage Cycle Controls Manage repetitive cycling schedules with a percentage cycle timer. These solutions offer flexible scheduling options and are an ideal choice for agriculture feeder and greenhouse misting applications. Contents Percentage Cycle Timer56 Sprinkler/Irrigation Time Switches57 Electromechanical Water Heater Timers58 Water Heater Timers59 Energy-Efficient Water Use in Action! Take advantage of "off-peak" hours and improve energy efficiency with WH40 Water Heater Timer from Intermatic. The WH40 provides direct 24-hour control and offers a variety of homeowner-friendly features, including a lockable hasp and a manual ON/OFF lever to control the water heater timer without opening the enclosure. Specialty Time Switches Specialty Time Switches Percentage Cycle Timer CT2000 Ratings Switch Type General Purpose Tungsten (Incandescent) Resistive (Heater) Ballast (Fluorescent) Pilot Duty Motor Wire Leads 8" Red Black White Warranty Operating Temperature SPST 20 A, 240 VAC, 60 Hz 5 A, 240 VAC, 60 Hz 20 A, 28 VDC, 240 VAC, 60 Hz 10 A, 277 VAC, 60 Hz 470 VA, 240 VAC, 60 Hz 1 HP, 120 VAC, 60 Hz, 2 HP, 240 VAC, 60 Hz #12 AWG #18 AWG #18 AWG 1-Year limited -14°F - 140°F (-10°C - 60°C) CT2000 PERCENTAGE CYCLE TIME SWITCH The CT2000 Percentage Cycle Time Switch is a field adjustable timer, offering true flexibility for repetitive cycle times via an upfront control button. The timer provides repetitive cycling for short-cycle applications. The timer enclosure includes two slotted mounting holes on 5" centers and a ½" knockout for conduit connection. APPLICATIONS · Agriculture Feeders · Greenhouse Misting Control FEATURES · Provides 8 field-selectable cycle durations of 30 seconds, 1, 3, 5, 10, 30 minutes and 1 or 4 hours · Front cover button enables true flexibility for repetitive cycle times · Temporary and permanent manual overrides · 30 separate positions enable precise percentage ON time selection · User settings stored in non-volatile memory · No DIP switches to program cycle time · Type 3R indoor/outdoor aluminum enclosure Model # CT2000 Input Voltage 120/240 VAC 60 Hz ENCLOSURE DIMENSIONS 56 Specialty Time Switches R8800 Series & T8800 Series SPRINKLER/IRRIGATION TIME SWITCHES WITH 14-DAY SKIPPER These irrigation timers are designed to permit one to 44 "ON" operations every 24 hours and provide watering increments down to 12 minutes or up to 20 hours and 45 minutes to ensure proper watering increments. These models also allow for biweekly scheduling with the convenient 14-day skipper for maximum water conservation and odd/even day compliance. APPLICATIONS · Agriculture Feeders · Greenhouse Misting Control FEATURES · Up to 44 ON/OFF settings per day · Water metering increments from 12 minutes to 20 hours and 45 minutes · 14-Day skipper enables irrigation to be omitted on selected day(s) · Allows for alternate-day scheduling ·O N/OFF/AUTO switch enables shutdown during rainy days and extended watering during dry periods without disturbing the cycle set on dial · Type 3R plastic indoor/outdoor enclosure Model # Switch Type Clock Motor Voltage Load Voltage Amps (per pole) Mechanism Only R8806M101C DPST 240 VAC, 60 Hz 240 VAC, 60 Hz 30 A T8805M101C DPST 125 VAC, 60 Hz 125 VAC, 60 Hz 15 A Indoor/outdoor type 3R plastic R8806P101C DPST 208/277 VAC, 60 Hz 240 VAC, 60 Hz 30 A R8815P101C* DPST 125 VAC, 60 Hz 120 VAC, 60 Hz 30 A R8816P101C* DPST 208/277 VAC, 60 Hz 240 VAC, 60 Hz 30 A T8805P101C SPST 125 VAC, 60 Hz 125 VAC, 60 Hz 15 A T8845PV** SPST 110/125 VAC, 60 Hz 24 VAC, 60 Hz 20 VA *Provided with a slide switch to enable/disable a Rain Sensor (not included). **Includes 24 Volt, 20 VA transformer. HP 3 1/2 3 1 1/2 3 1/2 Specialty Time Switches Sprinkler/Irrigation Time Switches R8806M101C Ratings: Enclosure H x W x D Plastic Indoor/Outdoor 10" x 6.5" x 4" (254 mm x 165.1 mm x 101.6 mm ) Knockout Dimensions Side/Back (1) combination 1/2" - 3/4" Bottom (2) combination 1/2" - 3/4" Warranty 1-Year limited Operating Temperature -40°F - 130°F (-40°C - 54°C) For enclosure line drawings and knockout locations, see pages 186-190. SPRINKLER/IRRIGATION TIME SWITCHES Coordinate watering schedules and manage heating system overrides with our selection of landscape water controls. Designed for commercial and residential applications, these controls help maintain lush outdoor landscapes and optimize water use. 57 Specialty Time Switches Specialty Time Switches Electromechanical Water Heater Timers WHAVQ4 Compliant Ratings Switch Configuration Switch Rating for NO Resistive Switch Rating for NC Resistive Operating Humidity Electrical Life Operating Temperature Warranty Patent# 6,563,237 40 A, DPDT 40 A, 250 VAC, 10,000 W 30 A, 250 VAC, 7500 W 0-95% RH, Non-condensing 50,000 operations at full load -4°F - 104°F (-20°C - 40°C) 1-Year limited WHAVQ Series 24-HOUR/7-DAY WITH BATTERY BACKUP AUTO-VOLTAGE ELECTRIC WATER HEATER TIMERS WHAVQ Series Water Heater Timers are designed for control of residential or commercial electric water heaters up to 10,000 Watts capacity running at 240 VAC. The unit is mounted in a UL Type 3R Outdoor enclosure and can be placed in basements or mechanical rooms. APPLICATIONS · Water Heater Control FEATURES · 40 A rating · Self-recharging battery backup with 7-day carry-over · Captive trippers - cannot be lost · 24-hour or 7-day models available · Three-way ON/OFF/AUTO manual override · Power and status LED indicators · Rainproof UL Type 3R enclosure · Saves energy by shutting water heaters OFF during "off peak periods" · Auto-voltage selection 120-240 VAC · Easy-to-read clock face Model # WHAVQ4 Input Voltage 120-240 VAC, 50/60 Hz Timing 24 hour 72-hour Carry-over, Battery, Self-recharging WIRING DIAGRAMS TIMER T L 1 L 2/N NC NO COM NC 2 NO 2 COM2 L N LOAD #1 LOAD #2 T TIMER L 1 L 2/N NC NO COM NC 2 NO 2 COM2 L1 L2 LOAD #1 ENCLOSURE DIMENSIONS 6.61" [16.79 cm] 5.73" [14.55 cm] 8.88" [22.56 cm] 3" [7.62 cm] WATER HEATER TIMERS Utilities in many areas of the country offer two electric rates for residential or commercial customers. One rate has the regular daytime electrical rate, the other is the "off-peak" rate. The "off-peak" rate provides customers with lower priced electricity during the nighttime and weekend periods. 58 EH10 & EH40 ELECTRONIC WATER HEATER TIME SWITCHES The EH Series Electronic Time Switches provide control for electric water heaters with to-the-minute accuracy in programming and time-keeping. The use of a water heater timer allows the customer to shift electricity use to "off-peak" time periods to reduce utility costs. These time switches can be programmed for repeat daily scheduling, 5-day work week scheduling, weekend scheduling or individual day scheduling. Models are available for both 120 and 240 VAC applications. APPLICATIONS · Agriculture Feeders · Greenhouse Misting Control · Water Heater Control FEATURES · 42 ON/OFF events per week · 7-day scheduling · To-the-minute programming and time-keeping accuracy · External override switch · LED load indicator · Replaceable battery backup Model # EH10 EH40 Input Voltage 120 VAC, 60 Hz 240 VAC, 60 Hz Switch Type SPST DPST Watts 3600 7200 Enclosure Indoor type 1 metal Indoor type 1 metal WH40 & T104-20 MECHANICAL WATER HEATER TIME SWITCHES With the easy-to-set "Yellow Dial," these time switches allow for basic control of electric water heaters. These time switches offer a minimum ON/OFF time of one hour, and are available for 208-250 VAC applications. With the proven reliability of our mechanical line, these time switches provide dependable electric water heater control. APPLICATIONS · Agriculture Feeders · Greenhouse Misting Control · Water Heater Control FEATURES · Two sets of ON/OFF trippers · Enables shifting electricity use into off-peak hours to reduce energy costs · Convenient external override switch · Up to 12 ON/12 OFF events per day Model # T104-20 WH40 Switch Type DPST DPST Clock Motor 208/277 VAC, 60 Hz 208/277 VAC, 60 Hz Amps (per pole) 40 A 40 A Watts Resistive 10000 10000 External Override No Yes Specialty Time Switches Water Heater Timers EH10 Ratings Switch Rating for EH10 Switch Rating for EH40 Knockout Dimensions Side/Back Bottom Operating Temperature Warranty 30 A Inductive, 30 A Resistive, 5 A Tungsten, 1 HP, 120 VAC, 60 Hz 30 A Inductive, 30 A Resistive, 5 A Tungsten, 1 1/2 HP, 240 VAC, 60 Hz (1) combination 1/2" - 3/4" (2) combination 1/2" - 3/4" -40°F - 104°F (-40°C - 40°C) 1-Year limited WH40 Ratings Power Consumption Enclosure Dimensions Metal Indoor (H x W x D) Knockout Dimensions Side/Back Bottom Operating Temperature Warranty 3 W 7 7/8"x 5 1/8"x 3 7/16" ( mm x mm x mm) (1) combination 1/2" - 3/4" (2) combination 1/2" - 3/4" -40°F - 130°F (-40°C - 54°C) 1-Year limited 59 Specialty Time Switches In-Wall Timer Solutions Convenient scheduling is always within reach with our wide selection of In-Wall Timers. These easy-to-install solutions are designed to simplify everyday lighting and load control needs. Indoor Lighting Control Upgrade indoor spaces with in-wall timers that manage daily lighting schedules and put occupants in control. Applications range from commercial buildings and retail stores to single-family homes and small offices. Timing/Scheduling ON/OFF Keep lights, ventilation systems and other loads on schedule with a 7-day or 24-hour in-wall timer. These versatile solutions make it easy to set ON/OFF schedules and promote energy efficiency. Outdoor Lighting Control Ideal for entryways, storefronts, front porches and more, a well-placed in-wall timer can promote security and reduce energy waste. Occupant Comfort Elevate residential and commercial living spaces with energy-saving in-wall timers. Advanced solutions like our ASCEND® Smart 7-Day Timer allow for easy smartphone control and provide convenient daily scheduling options. Contents ASCEND® Series62 7-Day Programmable Timers64 24-Hour Programmable Timers66 Electronic Countdown Timers68 Mechanical Spring Wound Countdown Timers70 In-Wall Timer Comparison Chart72 Accessories 73 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. In-Wall Timers ASCEND In-Wall Timers ASCEND® SMART IN-WALL TIMER (STW700W, STW700LA) Simplify home lighting automation projects with the Ascend Smart In-Wall Timer. An upgrade from Ascend Standard, our Wi-Fi enabled control offers many of the same benefits of a complex home automation system without the hassle. Quick Installation - Shave minutes off each time switch installation with streamlined smartphone programming options and an intuitive interface. No Hub Needed - Create a standalone home automation system without the need for a dedicated hub or smart home controller. Voice Activation - Pair the Ascend Smart In-Wall Timer with Amazon Alexa or the Google Assistant to deliver voice-activated programming commands, including ON/OFF and status check. Anywhere Access - Download the complimentary Ascend mobile app to any Apple® or Android® smartphone to update programming schedules on the fly. Versatile Design - Fit the Ascend into any home project with both single-pole or 3-way switch compatibility. ASCEND® Series ASCEND SMART 7-DAY PROGRAMMABLE WI-FI TIMER, 120 VAC, 15A Light Almond 20 TITLE L E D LISTED Ratings Input Voltage 120 VAC, 50/60 Hz General Purpose 15 A Electronic Ballast (LED) 5 A, 600 W Tungsten (Incandescent) 8 A Inductive (Heater) 15 A, 120 VAC, 50/60 Hz Motor 1 HP, 120 VAC, 50 Hz, 1 HP, 120 VAC, 60 Hz Dimensions H x W x D 2 3/4" x 1 3/4" x 1 1/3" (69.9 mm x 44.4 mm x 33.9 mm x Operating Temperature -4°F - 122°F (-20°C - 50°C) Warranty 3-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. Next generation timers with sleek, modern design and intuitive programming. Works with Amazon Alexa and Google Assistant; no hub required. Neutral required. Easily schedule lights and connected loads to turn on/off at specific times or based on sunrise/sunset. *NOTE: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. APPLICATIONS · Indoor Lighting Control · Air Movement & Ventilation · Outdoor Lighting Control FEATURES · Single-pole or 3-way switches · Ability to text/email saved schedules · 7-Day Timer with Automatic Daylight Saving and Astronomic ON/OFF at Dusk or Dawn · Sleek, Modern Design · Remote Access from anywhere, no hub required · Wi-Fi not needed for initial setup and scheduling · Fully set and schedule at the timer or via the Ascend app · Supporting mobile app available in the Apple App Store and on Google Play ·Automatic Astronomic ON/OFF dusk and dawn times to provide the most accurate lighting schedule possible · Automatic Daylight Saving Time (DST) Adjustment · Three pre-programmed schedule templates for convenience · Fully customizable scheduling for flexibility ·Non-replaceable battery backup keeps time and date information in the event of a power loss · Schedules and other settings are kept indefinitely in non-volatile memory · No Hub Required · 2-Hour override function · Decorator switch plate not included Model # Description Has WiFi STW700W Ascend Smart 7-Day Yes Programmable Wi-Fi Timer, 120 VAC, 15A, White STW700LA Ascend Smart 7-Day Yes Programmable Wi-Fi Timer, 120 VAC, 15A, Light Almond Note: For use with standard decorator plate, not included. Color White Neutral Required Yes Light Almond Yes 62 In-Wall Timers In-Wall Timers Ascend ASCEND® Standard Series ASCEND STANDARD 7-DAY PROGRAMMABLE TIMER, 120 VAC, 15A, WHITE The ASCEND® Standard In-Wall Timer is a 7-Day Programmable Timer featuring a sleek, modern design. The timer can be configured in minutes using a large backlit LCD display and includes pre-programmed templates for easy use. The Ascend Standard features Astronomic dusk-to-dawn settings and automatic Daylight Saving Time adjustments. Neutral required. *NOTE: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. APPLICATIONS · Air Movement & Ventilation · Indoor Lighting Control · Outdoor Lighting Control FEATURES · Quick, intuitive installation · Single-pole or 3-way switches · Sleek, Modern Design · 7-Day Timer with Automatic Daylight Saving and Astronomic ON/OFF at Dusk or Dawn · Intuitive Setup · Three pre-programmed schedule templates for convenience · Fully customized scheduling for flexibility · Program up to 42 unique events · Large, easy-to-read backlit LCD screen · Non-replaceable battery backup keeps time and date information in the event of a power loss · Schedules and other settings are kept indefinitely in non-volatile memory · 2-Hour override function · Decorator switch plate not included 20 TITLE L E D LISTED Model # Description Has WiFi ST700W Ascend Standard 7-Day Programmable No Timer, 120 VAC, 15A, White Note: For use with standard decorator plate, not included. Color Neutral Required White Yes Ratings Input Voltage 120 VAC, 50/60 Hz General Purpose 15 A Electronic Ballast (LED) 5 A, 600 W Inductive (Heater) 15 A, 120 VAC, 50/60 Hz Motor 1 HP, 120 VAC, 50/60 Hz Dimensions H x W x D 2 3/4" x 1 3/4" x 1 1/3" (69.9 mm x 44.4 mm x 33.9 mm) Operating Temperature -4°F - 122°F (-20°C - 50°C) Warranty 3-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. ASCEND® Touch- Navigate the core functions of Ascend Smart and Ascend Standard through an intuitive LCD interface. The visual display simplifies initial setup while helping homeowners view upcoming events and make updates with ease. Mobile- Monitor Ascend Smart from anywhere with the complimentary Ascend Smart Timer mobile app. Whether it's from the couch or across the continent Ascend Smart keep users in control. Program schedules, manually adjust ON/OFF settings and view the status of programs from any smartphone or tablet. Voice- Just say the word. Pair the Ascend Smart In-Wall Timer with voice assistant platforms, such as Amazon Alexa and the Google Assistant, to take your home to exciting new heights. The tech-forward feature allows homeowners to control Ascend through voice-activated commands without skipping a beat. 63 In-Wall Timers In-Wall Timers 7-Day Programmable Timers White Ivory Light Almond ST01 20 TITLE LISTED LED Ratings Input Voltage 120-277 VAC, 50/60 Hz Resistive (Heater) ST01 15 A, 1800-4155 W, 120-277 VAC EI600 20 A, 2400-5540 W, 120-277 VAC Tungsten (Incandescent) 1800 W, 120 VAC; 1248-1662 W, 208-277 VAC Ballast (Fluorescent) (EI600) 16 A, 1920-4432 VA, 120-277 VAC DC Loads 4 A, 12 VDC; 2 A, 28 VDC Motor 1 HP, 120 VAC, 50/60 Hz; 2 HP, 240 VAC, 50/60 Hz Dimensions H x W x D 4.125" x 1.75" x 1.8125" (104.8 mm x 44.5 mm x 46 mm) Neutral Required No Operating Temperature 32°F - 104°F (0°C - 40°C) Warranty ST01 1-Year limited EI600 5-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. EI600 Series & ST01 Series HEAVY-DUTY 7-DAY PROGRAMMABLE TIMERS Highly versatile Heavy-Duty Timers are ideal for any application that requires a simple or complex ON/OFF schedule, regardless of load. No neutral connection is required. APPLICATIONS · Indoor Lighting Control · Air Movement & Ventilation · Outdoor Lighting Control FEATURES · Versatile 7-day programmable schedules with up to 40 ON/OFF events · Astronomic clock feature determines dawn and dusk times · Automatic Daylight Saving Time (DST) adjustment · Random mode varies ON/OFF schedule to provide a "lived-in" appearance · Single or 3-way switch compatible installation · Incandescent/fluorescent/CFL/LED compatible · Isolated switch allows timer to be used with any load type, including AC and DC loads · Replaceable CR2 lithium battery provides up to three years of operation · No neutral wire connection enables easy retrofitting and quicker installation White Ivory Light Almond Max Load Handling Capability EI600WC EI600C EI600LAC 20 A ST01 - ST01A 15 A Note: For use with standard decorator plate, not included. 7-DAY/24-HOUR TIMER APPLICATIONS · Entryway lighting · Deck and landscape light controls · Attic fans · Pumps · Small commercial signage and store lighting · Hallway lighting 64 EI500 Series STANDARD 7-DAY PROGRAMMABLE TIMERS - 15 A For installation on 15 A circuits, this timer provides 24-hour or 7-day programming of lights, fans, pumps and other medium-duty loads. APPLICATIONS · Indoor Lighting Control · Air Movement & Ventilation · Outdoor Lighting Control FEATURES · 7-day programmable schedules with 14 ON/OFF events · Random mode varies ON/OFF schedule to provide a "lived-in" appearance · Single-pole circuit · Incandescent/fluorescent/CFL/LED compatible · Built-in rechargeable, non-serviceable battery backup · Requires neutral connection · Backlit LCD display White Ivory Light Almond EI500WC EI500C EI500LAC Note: For use with standard decorator plate, not included. EJ600 Series STANDARD 7-DAY PROGRAMMABLE TIMERS - 12 A A 12 A rated timer that provides full 7-day programming capabilities with dusk-to-dawn functionality, ideal for use with medium to low power loads. APPLICATIONS · Indoor Lighting Control · Air Movement & Ventilation · Outdoor Lighting Control FEATURES · 7-day programmable schedules with 14 ON/OFF events · Astronomic clock feature determines dawn and dusk times · Automatic Daylight Saving Time (DST) adjustment · Random mode varies ON/OFF schedule to provide a "lived-in" appearance · Single or 3-way switch compatible installation · Incandescent/fluorescent compatible · Built-in rechargeable, non-serviceable battery backup · Requires neutral connection White Light Almond EJ600 EJ600A Note: For use with standard decorator plate, not included. In-Wall Timers 7-Day Programmable Timers White Ivory Light Almond LED EI500WC Ratings Input Voltage 125 VAC, 60 Hz Resistive (Heater) 15 A, 1875 W Tungsten (Incandescent) 1000 W Ballast (Fluorescent) 8 A, 1000 VA Electronic Ballast (LED) 4 A, 500 VA Motor 1/4 HP, 125 VAC, 60 Hz Dimensions H x W x D 4.125" x 1.75" x 1.4375" (104.8 mm x 44.5 mm x 36.5 mm) Neutral Required Yes Operating Temperature 32°F - 104°F (0°C - 40°C) Warranty 1-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. White Light Almond LED EJ600 Ratings Input Voltage 120 VAC, 60 Hz Resistive (Heater) 12 A, 1440 W Tungsten (Incandescent) 1440 W, multi-gang, 1800 W, single-gang Ballast (Fluorescent) 4 A, 500 VA Motor 1/2 HP Dimensions H x W x D 4.125" x 1.75" x 1.4375" (104.8 mm x 44.5 mm x 36.5 mm) Neutral Required Yes Operating Temperature 32°F - 104°F (0°C - 40°C) Warranty 1-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. 65 In-Wall Timers In-Wall Timers In-Wall Timers 24-Hour Programmable Timers E1010 E1020 Ratings Input Voltage 125 VAC, 60 Hz Resistive (Heater) 15 A, 125 VAC, 60 Hz Motor 12 FLA, 125 VAC, 60 Hz Dimensions H x W x D 4.25" x 3.25" x 1.375" (108 mm x 82.6 mm x 34.9 mm) Neutral Required Yes Operating Temperature -4°F - 77°F (-20°C - 25°C) Warranty 1-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. E1000 Series HEAVY DUTY MECHANICAL IN-WALL TIMERS - 15 A These Heavy-Duty In-Wall Timers are ideal for turning on lights, fans, pumps and other heavy duty loads for energy savings, security and convenience. The timer provides up to 12 ON and 12 OFF operations per day. APPLICATIONS · Air Movement & Ventilation · Indoor Lighting Control · Outdoor Lighting Control FEATURES ·E1010 includes one ON/OFF permanently attached tripper for single ON/OFF control per 24-hour period · E1020 includes two ON/OFF trippers and can accommodate up to 12 ON/OFF trippers · Programmable in 30-minute intervals · Turns ON/OFF heavy-duty loads for energy savings, security and convenience · Mounts to any standard junction box · Requires neutral connection Model # E1010 E1020 Description 24-Hour Heavy-Duty Mechanical In-Wall Timer, 125VAC, 15 A, Permanent Trippers, White 24-Hour Heavy-Duty Mechanical In-Wall Timer, 125VAC, 15 A, Removable Trippers, White HEAVY DUTY MECHANICAL TIMER APPLICATIONS · Attic Fans · Deck Light Controls · Entryway Lighting · Hallway Lighting · Landscape Light Controls · Pumps · Small Commercial Signage · Store Lighting 66 In-Wall Timers KM2 Series HEAVY-DUTY MECHANICAL IN-WALL TIMERS - 20 A For installing on circuits up to 20 A, this timer provides automatic 24-hour ON/OFF control of outdoor/indoor lighting, fans, pumps, office equipment and other types of loads. APPLICATIONS · Indoor Lighting Control · Air Movement & Ventilation · Outdoor Lighting Control FEATURES · 72 trippers provide 36 ON/OFF events per 24-hour period · Captive trippers with 20-minute switching intervals · 3-way (SPDT) switch available · 3-position ON/OFF/AUTO override provides continuous ON or OFF operation · Reliable synchronous timer motor · Multiple wall plates available · Easy wiring and installation · Heavy-Duty 20 A rating · Requires neutral connection Model # SPST KM2ST-1G KM2ST-2G KM2ST-3G KM2ST-2D SPDT KM2STU-1G Wall Plate Configuration Timer Only Timer + Toggle Switch Timer + Toggle Switch Timer + Decorator Switch 2-Gang 3-Gang 2-Gang Timer Only WIRING DIAGRAMS StandarSdtIannstdalalartdionInstallation HOT (BLACK) NEUTRAL (WHITE) LOAD (RED) LOAD In-Wall Timers 24-Hour Programmable Timers KMS2T-IG Timer Toggle Switch Plate 3-Way Installation 2-Gang HOT (BLACK) NEUTRAL (WHITE) 3-Gang (RED) (BLUE) 3-Way Switch LOAD Standard Installation Ratings Input Voltage 120 VAC, 60 Hz Resistive (Heater) Motor 20 A, 120 VAC, 60 Hz HOT (BLA1CKH) P, 120 VAC, 60LOHAzD (RED) LOAD Neutral Required Yes NEUTRAL (WHITE) Wiring Terminals SPST SPST (3) #14 AWG color coded SPDT SPDT (4) #14 AWG color coded Operating Humidity 0 to 95%, Non-condensing Operating Temperature -40°F - 180°F (-40°C - 82°C) Warranty 1-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. 3-3W-aWy IanystaInllasttioanllation 4-Gang Timer and Decorator Switch Plate HOT (BLACK) NEUTRAL (WHITE) (RED) (BLUE) 3-Way Switch LOAD 2-Gang 3-Gang Timer and Receptacle Plate 2-Gang 67 In-Wall Timers In-Wall Timers Electronic Countdown Timers White Ivory Light Almond EI400WC EI400 Series PROGRAMMABLE ELECTRONIC COUNTDOWN TIMER Offering a programmable countdown time between one second and 24 hours, this versatile timer can handle any application, regardless of load type. No neutral connection is required. APPLICATIONS · Indoor Lighting Control · Air Movement & Ventilation FEATURES · Programmable countdown time interval from one second to 24 hours · Settings stored in non-volatile memory · Optional audible and/or visual warning of impending load switch OFF · Lockable settings help avoid unintended changes · Single-pole or 3-way switch compatible installation · Incandescent/fluorescent/CFL/LED compatible · Isolated switch allows timer to be used with any load type including AC and DC loads · Replaceable CR2 lithium battery provides up to three years of operation · No neutral wire connection enables easy retrofitting and quicker installation · 24-hour programming allows for continuous operation · Decorator switch plate not included LED Ratings Input Voltage 120-277 VAC, 50/60 Hz Resistive (Heater) 20 A, 2400-5540 W, 120-277 VAC Tungsten (Incandescent) 1800 W, 120 VAC; 1248-1662 W, 208-277 VAC DC Loads 4 A, 12 VDC; 2 A, 28 VDC Motor 1 HP, 120 VAC, 50 Hz, 1 HP, 120 VAC, 60 Hz, 2 HP, 240 VAC, 50 Hz, 2 HP, 240 VAC, 60 Hz Dimensions H x W x D 4.125" x 1.75" x 1.1875" (104.8 mm x 44.5 x 30.2 mm) Neutral Required No Operating Temperature 32°F - 122°F (0°C - 50°C) Warranty 5-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. White Ivory EI400WC EI400C Note: For use with standard decorator plate, not included. COUNTDOWN TIMER APPLICATIONS · Bathroom fans · Spas · Hot tubs · Storage closets · Garage lights Light Almond EI400LAC 68 In-Wall Timers EI200 Series ELECTRONIC COUNTDOWN TIMERS WITH PRESET TIMES This timer requires no programming; preset countdown times are activated by pressing a single button. Silent operation makes this timer ideal for applications where the noise of mechanical countdown timers is of concern. APPLICATIONS · Indoor Lighting Control · Air Movement & Ventilation FEATURES · Provides silent operation in time ranges from five minutes to 12 hours ·S ingle-button time selection, with some models having a HOLD mode, for continuous ON operation · Replaces single-pole switches in a variety of applications · Incandescent/fluorescent/CFL/LED compatible · For use with decorator-style wall plate (not included · Requires neutral connection White Ivory Light Almond In-Wall Timers Electronic Countdown Timers Without HOLD EI215W With HOLD EI200W White Without HOLD EI205W EI215W EI235W With HOLD EI200W EI210W EI220W EI230W Ivory EI200 EI210 Light Almond Preset Times EI205LA 5 min, 15 min, 30 min, 45 min, 1 hr 15 min, 30 min, 1 hr, 2 hrs, 4 hrs 15 min, 30 min, 45 min, 1 hr, 2 hrs EI200LA EI210LA 5 min, 10 min, 15 min, 30 min 10 min, 20 min, 30 min, 60 min 1 hr, 2 hrs, 4 hrs, 8 hrs 2 hrs, 4 hrs, 8 hrs, 12 hrs LED Ratings Input Voltage 120 VAC, 60 Hz Resistive (Heater) 15 A, 1800 W Tungsten (Incandescent) 1000 W Ballast (Fluorescent) 8 A, 1000 VA Electronic Ballast (LED) 4 A, 500 VA Motor 1/4 HP Dimensions H x W x D 4.125" x 1.688" x 1.438" (104.8 mm x 42.93 mm x 36.5 mm) Neutral Required Yes Operating Temperature 32°F- 104°F (0°C - 40°C) Warranty 1-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. 69 In-Wall Timers In-Wall Timers Mechanical Spring Wound Countdown Timers Without HOLD FD60MWC With HOLD FD6HHW LED Ratings Input Voltage 125-277 VAC, 50/60 Hz Resistive (Heater) 20 A, 2500 W, 125 VAC; 10 A, 2500 W, 250 VAC; 10 A, 2770 W, 277 VAC Tungsten (Incandescent) 7 A, 125 VAC, 50 Hz, 7 A, 125 VAC, 60 Hz, 875 W Motor 1 HP, 125 VAC; 2 HP, 250 VAC Dimensions H x W x D 4.125" x 1.75" x 1.25" (104.8 mm x 44.5 mm x 31.8 mm) Neutral Required No Operating Temperature 32°F - 104°F (0°C - 40°C) Warranty 1-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. White Ivory Light Almond FD Series SPRING WOUND COUNTDOWN TIMERS DECORATOR STYLE The FD Series Decorator Countdown Timers are designed to replace any standard or decorator style wall switch, single- or multi-gang. These mechanical timers do not require electricity to operate. They automatically limit the ON times for fans, lighting, motors, heaters and other energy consuming loads. APPLICATIONS · Indoor Lighting Control · Outdoor Lighting Control · Motor Control · Air Movement & Ventilation FEATURES · No electricity required to operate · Replaces any standard or decorator single- or multi-gang wall switch · Automatically limits ON time for energy consuming loads · Quick and easy installation · Time-saving up front terminal connection with teeter-type terminals · Models available from 5 minute to 12 hour countdown time intervals · Incandescent/fluorescent/CFL/LED compatible · No neutral connection is required Without HOLD With HOLD White Ivory Light White Almond SPST FD5MW FD5M FD15MWC FD15MC FD15MAC FD15MHW FD30MWC FD30MC FD30MAC FD30MHW FD60MWC FD60MC FD60MAC FD60MHW FD2HW FD2H FD4HW FD4H FD6HW FD6H FD6HHW FD12HWC FD12HC FD12HHW 2-Circuit (1) NO + (1) NC FD32HW FD32H Ivory FD30MH FD60MH FD6HH FD12HH Maximum Switch Type Time 5 min 15 min 30 min 60 min 2 hrs 4 hrs 6 hrs 12 hrs L1 SPST Configuration 2 hrs L1 FD34H DPST FD415M FD430MW FD430M FD460MW FD46HW Note: For use with decorator or toggle-style switch plates (not included). For accessories please see page 73. 4 hrs 15 min 30 min 60 min 6 hrs L2 *For SPDT Configuration Jumper L1 & L2 Together L1 L2 DPST Configuration 70 In-Wall Timers FF Series SPRING WOUND COUNTDOWN TIMERS COMMERCIAL STYLE The FF Series Commercial Countdown Timers are designed to replace any standard wall switch and do not require electricity to operate. These energy-efficient switches automatically limit the ON times for fans, lighting, motors, heaters, and other energy consuming loads. A commercial "brushed metal" look plate (plastic construction) meets NEC requirements. APPLICATIONS · Indoor Lighting Control · Outdoor Lighting Control · Motor Control · Air Movement & Ventilation FEATURES · No electricity required to operate · Replaces any standard or decorator single-gang wall switch · Automatically limits ON time for energy consuming loads · Quick and easy installation · Time-saving up front terminal connection with teeter-type terminals · Brushed metal look switch plate meets NEC requirements (plate is included) · Incandescent/fluorescent/CFL/LED compatible · No neutral connection is required Without HOLD With HOLD SPST FF5M FF5MH FF15MC FF15MH FF30MC FF30MH FF60MC FF60MHC FF2H FF4H FF6H FF6HH FF12HC FF12HHC SPDT FF315M FF330M FF360M FF32H FF32HH FF34H FF34HH FF36H FF312H FF312HH DPST FF415M FF430M FF460M FF46H FF412H For accessories please see page 73. Maximum Time Switch Type 5 min 15 min 30 min 60 min 2 hrs 4 hrs 6 hrs 12 hrs L1 SPST Configuration 15 min 30 min 60 min 2 hrs 4 hrs 6 hrs 12 hrs L1 L2 *For SPDT Configuration Jumper L1 & L2 Together 15 min 30 min 60 min 6 hrs 12 hrs L1 L2 DPST Configuration In-Wall Timers Mechanical Spring Wound Countdown Timers Without HOLD FF5M With HOLD FF6HH LED Ratings Input Voltage 125-277 VAC, 50/60 Hz Resistive (Heater) 20 A, 2500 W, 125 VAC; 10 A, 2500 W, 250 VAC; 10 A, 2770 W, 277 VAC Tungsten (Incandescent) 7 A, 125 VAC, 50 Hz, 7 A, 125 VAC, 60 Hz, 875 W Motor 1 HP, 125 VAC; 2 HP, 250 VAC Dimensions H x W x D 4.125" x 1.75" x 1.25" (104.8 mm x 44.5 mm x 31.8 mm) Neutral Required No Operating Temperature 40°F - 120°F (4°C - 49°C) Warranty 1-Year limited Note: Not for use with sunlamps, saunas, or loads that could cause personal injury if timed incorrectly. 71 In-Wall Timers In-Wall Timers Comparison Chart CHOOSE THE RIGHT IN-WALL TIMER FOR YOUR NEXT PROJECT From input voltage to motor load, this chart highlights the key features and ratings of our in-wall solutions. FEATURES NEUTRAL REQUIRED WI-FI WITH APP CONTROLS CFL CONTROLS LED 3-WAY SWITCHING RATINGS INPUT VOLTAGE RESISTIVE (HEATER), AC TUNGSTEN (INCANDESCENT) BALLAST (FLUORESCENT) ELECTRONIC BALLAST (LED) DC LOADS MOTOR LOAD WARRANTY AGENCY BATTERY RECHARGEABLE REPLACEABLE SCHEDULES STORED IN NON-VOLATILE MEMORY PROGRAMMING ASTRONOMIC DAYLIGHT SAVING TIME RANDOM PROGRAM RANGE MAXIMUM NUMBER OF EVENTS Series ST700 EI600 ST01 EJ600 EI500 KM2 FD FF STW700W KM2STU-1G 120 VAC, 50/60 Hz 15 A 960 W 120-277 VAC, 50/60 Hz; 12/28 VDC 120-277 VAC, 50/60 Hz; 12/28 VDC 120 VAC, 60 Hz 125 VAC, 60 Hz 20 A 15 A 12 A 15 A 1800 W, 120 VAC; 1800 W, 120 VAC; 1800 W, 1248-1662 W, 1248-1662 W, Single-Gang; 208-277 VAC 208-277 VAC 1440 W, Multi-Gang 8 A, 960 VA, 16 A, 1920-4432 VA 4 120 VAC; A, 832-1108 VA, 208-277 VAC 4 A, 500 VA 1000 W 8 A, 1000 VA 120 VAC, 60 Hz 125-277 VAC, 50/60 Hz 125-277 VAC, 50/60 Hz 20 A 1350 W 20 A, 2500 W, 125 20 A, 2500 W, 125 VAC; 10 A, 2500 W, VAC; 10 A, 2500 W, 250 VAC; 10 A, 250 VAC; 10 A, 2770 W, 277 VAC 2770 W, 277 VAC 7 A, 125 VAC, 50 Hz, 7 A, 125 VAC, 50 Hz, 7 A, 125 VAC, 7 A, 125 VAC, 60 Hz, 875 W 60 Hz, 875 W 5 A, 600 W 4 A, 500 W 1 HP 3-Year limited 4 A, 12 VDC; 2 A, 28 VDC 1 HP, 120 VAC; 2 HP, 240 VAC 5-Year limited 4 A, 12 VDC; 2 A, 28 VDC 1 HP, 120 VAC; 2 HP, 204 VAC 1-Year limited 1/2 HP 1-Year limited 1/4 HP 1-Year limited 1 HP 1-Year limited 1 HP, 125 VAC; 2 HP, 250 VAC 1-Year limited 1 HP, 125 VAC; 2 HP, 250 VAC 1-Year limited 7-Day 42 7-Day 40 7-Day 40 7-Day 14 7-Day 14 24-Hour 36 5-Minutes to 6-Hours 1 5-Minutes to 6-Hours 1 72 In-Wall Timers In-Wall Timers Accessories IN-WALL TIMER ACCESSORIES Model # 107SB189 107SB192 146--00045 146--00046 146--00047 146MT577 146MT579 148FD5024 148FD5025 148FD5029 148FD5030 148FD5031 148FD5032 148FD5033 148FD5034 148FD5035 148FD5036 148FD5037 148FD5038 148FD5039 148FD5052 148FD5054 148FD5056 148FD5058 148FD5059 148FD5060 148FD5061 148FD5062 148FD5063 148FD5064 Description Red (ON) tripper for SB Series, HB112C, HB113C,HB114C (Indoor), AL300RTW, AL600TW, AL900TW, AL60TW and ML Series Transformer Timers Black (OFF) tripper for SB Series, HB112C, HB113C, HB114C (Indoor), AL300RTW, AL600TW, AL900TW, AL60TW and ML Series Transformer Timers Knob-Wall Switch FD Series - Ivory Knob-Wall Switch FD Series - White Knob-Wall Switch FD Series - Almond Knob-Wall Switch FF Series - White Knob-Wall Switch FF Series - Black Plate for 5-Min with HOLD (FF5MH) Plate for 5-Min without HOLD (FF5M) Plate for 60-Min with HOLD (FF60MHC) Plate for 6-Hr without HOLD (FF36H, FF46H, FF6H) Plate for 6-Hr with HOLD (FF6HH) Plate for 12-Hr without HOLD (FF12HC, FF312H, FF412H) Plate for 12-Hr with HOLD (FF12HHC, FF312HH) Plate for 2-Hr without HOLD (FF2H, FF32H) Plate for 2-Hr with HOLD (FF32HH) Plate for 4-Hr without HOLD (FF34H, FF4H) Plate for 4-Hr with HOLD (FF34HH) Plate for 30-Min with HOLD (FF30MH) Plate for 15-Min with HOLD (FF15MH) Plate for 5-Min without HOLD, White (FD5MW) Plate for 15-Min with HOLD, White (FD15MHW) Plate for 30-Min with HOLD, White (FD30MHW) Plate for 60-Min with HOLD, White (FD60MHW) Plate for 6-Hr without HOLD, White (FD46HW, FD6HW) Plate for 6-Hr with HOLD, White (FD6HHW) Plate for 12-Hr without HOLD, White (FD12HWC) Plate for 12-Hr with HOLD, White (FD12HHW) Plate for 2-Hr without HOLD, White (FD2HW, FD32HW) Plate for 5-Min without HOLD, Ivory (FD5M) Model # Description 148FD5068 Plate for 30-Min with HOLD, Ivory (FD30MH) 148FD5070 Plate for 60-Min with HOLD, Ivory (FD60MH) 148FD5071 Plate for 6-Hr without HOLD, Ivory (FD36H, FD46H, FD6H) 148FD5072 Plate for 6-Hr with HOLD, Ivory (FD6HH) 148FD5073 Plate for 12-Hr without HOLD, Ivory (FD12HC) 148FD5074 Plate for 12-Hr with HOLD, Ivory (FD12HH) 148FD5075 Plate for 2-Hr without HOLD, Ivory (FD2H, FD32H) 148FD5076 Plate for 4-Hr without HOLD, Ivory (FD34H, FD4H) 148FD5077 Plate for 15-Min without HOLD, Light Almond (FD15MAC) 148FD5078 Plate for 30-Min without HOLD, Light Almond (FD30MAC) 148FD5079 Plate for 60-Min without HOLD, Light Almond (FD60MAC) 148FD5080 Plate for 4-Hr without HOLD, White (FD34HW, FD4HW) 156EB1945A Trippers for E1020 (Pack of 2) 24--00041 Wall Plate for KM2ST-2G, 2 Gang (Timer and Toggle Switch), White 24--00042 Wall Plate for KM2ST-3G, 3 Gang (Timer and 2 Toggle Switches), White 24--00046 Wall Plate for KM2ST-2D, 2 Gang (Timer and Decorator Switch), White 24--00109 Wall Plate for KM2ST-1G or KM2STU-1G, Single Gang, White FD15MP Plate for 15-Min without HOLD, Ivory (FD15MC, FD415M) FD15MPW Plate for 15-Min without HOLD, White (FD15MWC) FD30MP Plate for 30-Min without HOLD, Ivory (FD30MC, FD430M) FD30MPW Plate for 30-Min without HOLD, White (FD30MWC, FD430MW) FD60MP Plate for 60-Min without HOLD, Ivory (FD460M, FD60MC) FD60MPW Plate for 60-Min without HOLD, White (FD460MW, FD60MWC) FF15MP Plate for 15-Min without HOLD, Silver (FF15MC, FF315M, FF415M) FF30MP Plate for 30-Min without HOLD, Silver (FF30MC, FF330M, FF430M) FF60MP Plate for 60-Min without HOLD, Silver (FF360M, FF460M, FF60MC) 146--00045 146MT577 107SB189 107SB192 148FD5038 146--00046 FF60MP 146--00047 73 Plug-In Timer Solutions Install energy savings in an instant with our convenient plug-in timer solutions. These user-friendly mechanical and electronic controls make it easy to create ON/OFF schedules for lights, pumps, fans and more. Indoor Convenience Connect our plug-in timers to lamps, fans, air conditioners and more to add an extra level of comfort to everyday. They can be installed in minutes and make it easy to create daily or weekly ON/OFF schedules. Holiday Lighting Take holiday decorating to the next level with our versatile plug-in timers. Once installed, users can enjoy lighting displays on fixed ON/OFF schedule without the hassle of plugging decorations into the wall or flipping the switch on a power strip. Heavy-Duty Appliances Handle input voltages of up to 240 VAC with our selection of heavy-duty plug-in timers. These durable controls are perfect to pair with air conditioners and ventilation equipment. Rugged Outdoor Control Take command of ON/OFF schedules in outdoor settings with a variety of outdoor plug-in timers. Select models offer a built-in enclosure, which protects the control from the elements and supports year-round use Contents Indoor 76 Outdoor 78 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Plug-In Timer Plug-In Timer Indoor HB112 HB113 HB114 HB110 Series Ratings Input Voltage HB113 HB112, HB114 Resistive (Heater) HB112 HB113 HB114 Tungsten (Incandescent) Inductive Ballast (Heater) HB113 HB112, HB114 Pilot Duty HB113 HB112, HB114 Motor HB113 HB112, HB114 Warranty 120 VAC, 60 Hz 240 VAC, 60 Hz 15 A, 240 VAC, 60 Hz 20 A, 125 VAC, 60 Hz 20 A, 240 VAC, 60 Hz 1250 W, 125 VAC, 60 Hz 8 A, 125 VAC, 60 Hz 8 A, 240 VAC, 60 Hz 576 VA, 125 VAC, 60 Hz 768 VA, 240 VAC, 60 Hz 2 HP, 240 VAC, 60 Hz 2 HP, 240 VAC, 60 Hz 1-Year limited HB110 Series INDOOR HEAVY-DUTY APPLIANCE PLUG-IN TIMERS Plug-in timers provide 24-hour ON/OFF scheduling for high power appliances, such as window mounted air conditioners, by accepting their specialized NEMA plugs. APPLICATIONS · Air Movement & Ventilation · Indoor Lighting Control FEATURES ·2 ON/2 OFF settings per day with removable trippers, more ON/OFF events with addition of extra trippers · Minimum 30-min ON/OFF time · Manual ON/OFF Override · Grounded 125 and 240 V NEMA receptacle and plug · Plugs directly into wall outlet Model # Input Voltage HB112 240 VAC, 60 Hz Rect/Plug 6-15 HB113 120 VAC, 60 Hz 5-20 HB114 240 VAC, 60 Hz 6-20 Indoor Applications · Lamps · Appliances · Electronics · Heaters · Window Air Conditioning · Chargers 76 Plug-In Timer TN311 Series HEAVY-DUTY 24-HOUR INDOOR MECHANICAL PLUG-IN TIMER The TN311 Series provides a quick and easy way to automate ON/OFF schedules and plugs directly into standard wall outlets. APPLICATIONS · Air Movement & Ventilation · Indoor Lighting Control FEATURES ·3 ON/3 OFF settings per day with removable trippers, more ON/OFF events with addition of extra trippers · Minimum 30-min ON/OFF time · Grounded receptacle and 3-prong plug · Plugs directly into wall outlet Model # TN311 Input Voltage 125 VAC, 60 Hz Rect/Plug 5-15 Plug-In Timer Indoor TN311 1x Ratings Input Voltage 125 VAC, 60 Hz Resistive (Heater) 15 A, 125 VAC, 60 Hz Tungsten (Incandescent) 1875 W, 125 VAC, 60 Hz Inductive Ballast (Fluorescent) 15 A, 125 VAC Dimensions H x W x D 3 1/8" x 3" x 2" (79 mm x 76 mm x 51 mm) Warranty 1-Year limited DT620 Series 7-DAY INDOOR DIGITAL PLUG-IN TIMER Full feature plug-in timer provides full 7-day programming with astronomical clock and Daylight Saving Time (DST) adjustment in a convenient plug-in for quick and easy automation. APPLICATIONS · Air Movement & Ventilation · Indoor Lighting Control FEATURES · 28 ON/OFF programmable events ·F ull 7-day programming options, including astronomical clock,automatic DST adjustment and random mode · Two grounded receptacles and a grounded plug · LR44 battery backup (included) · Plugs directly into wall outlet Model # DT620 Input Voltage 120 VAC, 60 Hz Rect/Plug 5-15 DT620 2x 20 TITLE LISTED Ratings Input Voltage Resistive (Heater) Tungsten (Incandescent) Inductive Ballast (Fluorescent) Motor Dimensions H x W x D Warranty 120 VAC, 60 Hz 15 A, 120 VAC 1000 W, 120 VAC 12 A, 120 VAC 1/2 HP, 120 VAC 3 1/5" x 3 1/3" x 2 1/4" (81 mm x 84 mm x 57 mm) 1-Year limited 77 Plug-In Timer Plug-In Timer Outdoor P1100 Series OUTDOOR MECHANICAL PLUG-IN TIMERS WITH BUILT-IN ENCLOSURE P1101 P1121 P1131 Ratings Input Voltage Resistive (Heater) Tungsten (Incandescent) Motor Dimensions H x W x D P1101, P1131 P1121 Warranty 120 VAC, 60 Hz 20 A, 120 VAC, 60 Hz 1800 W, 120 VAC, 60 Hz 1 HP, 16 FLA, 96 LRA @ 120 VAC 5 3/8" x 5 1/8" x 2 1/2" (137 mm x 130 mm x 64 mm) 5 5/8" x 3 5/8" x 3 1/4" (143 mm x 92 mm x 83 mm) 1-Year limited These plug-in timers are grounded and utilize a flip-open enclosure rated for outdoor use. These heavy-duty timers are great for providing timer function to pumps, landscaping or holiday lighting. 24-hour timers come with 2 On and 2 Off settings. APPLICATIONS · Outdoor Lighting Control · Landscape Water Control · Pool Pump · Outdoor Water Fountains FEATURES · 2 ON/2 OFF settings per day with removable trippers, more ON/OFF events with addition of extra trippers · Minimum 30-min ON/OFF time · Built into outdoor rated enclosure with clear or black flip cover · Grounded standard or locking type style NEMA plug and receptacle · Plugs directly into wall outlet Model # P1101 Input Voltage 120 VAC, 60 Hz Rcpt/Plug 5-15 Cord Length Cover 22" Black P1121 120 VAC, 60 Hz 5-15 13" Black P1131 120 VAC, 60 Hz L5-20 22" Black TN111RM40 24-HOUR OUTDOOR MECHANICAL PLUG-IN TIMER 1x TN111RM40 Ratings Input Voltage Resistive (Heater) Inductive Ballast (Fluorescent) Motor Dimensions H x W x D Warranty 125 VAC, 60 Hz 9 A (1125 W), 125 VAC, 60 Hz 9 A, 125 VAC, 60 Hz 1/3 HP 3 1/8" x 3" x 2" (79 mm x 76 mm 51 mm) 1-Year limited Plug-in timer rated for installation into a Type 3R outdoor low voltage transformer enclosure. Simple implementation of ON/OFF schedule. APPLICATIONS · Air Movement & Ventilation · Indoor Lighting Control · Outdoor Lighting Control · Landscape Water Control FEATURES ·2 ON/2 OFF settings per day with removable trippers, more ON/OFF events with addition of extra trippers · Minimum 30-min ON/OFF time · Rated for outdoor use in a Type 3R outdoor enclosure · Manual override dial Model # TN111RM40 Input Voltage 125 VAC, 60 Hz Rcpt/Plug 1-15 Outdoor Applications · Pumps · Water Fountains · Aerators · Landscape/Holiday Lighting · Engine Block Heaters 78 HB880R 7-DAY OUTDOOR DIGITAL PLUG-IN TIMER Full feature plug-in timer provides 7-day programming in a weatherproof enclosure with astronomical clock and Daylight Saving Time (DST) adjustment in a convenient plug-in for quick and easy automation. APPLICATIONS · Outdoor Lighting Control · Landscape Water Control FEATURES · 14 ON/OFF programmable events ·F ull 7-day programming options, including astronomical clock, automatic DST adjustment and random mode · 2 grounded receptacles with 24" cord and grounded plug · Incandescent/fluorescent/CFL/LED compatible · AA battery backup (included) · Plugs directly into wall outlet Model # HB880R Input Voltage 120 VAC, 60 Hz Rect/Plug 5-15 DT200LT Series DIGITAL LANDSCAPE TIMER Digital 24-hour landscape timer with DST, rated for use in low voltage transformers up to 1200W featuring ON programming at Dusk or predetermined time and OFF at Dawn or predetermined time. APPLICATIONS · Indoor Lighting Control · Outdoor Lighting Control · Landscape Water Control FEATURES · Factory set AUTO DST option takes the hassle out of Daylight Saving Time adjustments · One push, programming override for homeowner convenience · Rated for use in low voltage transformers up to 1200 W ·Two included LR44 batteries retain the correct time and settings for up to three months without power · Use with UL Certified Type 3R enclosure (sold separately) · Intermatic Linesync technology provides accurate timing for years Model # DT200LT Input Voltage 120 VAC, 60 Hz Rect/Plug 5-15 Plug-In Timer Outdoor HB880R 2x 20 TITLE LISTED LED Ratings Input Voltage 120 VAC, 60 Hz Electronic Ballast (LED) 500 VA, 120 VAC, 60 Hz Resistive (Heater) 15 A, 120 VAC, 60 Hz Tungsten (Incandescent) 1000 W, 120 VAC, 60 Hz Inductive Ballast (Fluorescent) 8.3 A, 120 VAC, 60 Hz Motor 1/2 HP, 120 VAC, 60 Hz Dimensions H x W x D 5 3/8" x 5" x 1 7/8" (137 mm x 129 mm x 48 mm) Warranty 1-Year limited DT200LT 2x 20 TITLE LISTED Ratings Input Voltage 120 VAC, 60 Hz Resistive (Heater) 15 A, 120 VAC, 60 Hz Tungsten (Incandescent) 1000 W, 120 VAC, 60 Hz Inductive Ballast (Fluorescent) 12 A, 120 VAC, 60 Hz Motor 1/2 HP @ 120 VAC, 60 Hz Dimensions H x W x D 3 3/16" x 3 5/16" x 2 1/4" (81 mm x 84 mm x 57 mm) Warranty 1-Year limited 79 Plug-In Timer Occupancy Sensor Solutions Increase energy-efficiency in limited-use spaces with easy-to-install Intermatic occupancy and vacancy sensors. Our range of in-wall and ceiling mount controls ensure lights stay on only when needed and help reduce energy costs. Storage Areas and Closets Bring hands-free lighting control to storage areas, supply closets, garages and more with a PIR or dual-tech occupancy/vacancy sensor. Once installed, lights activate only when an occupant's presence is detected (when set in occupancy mode), allowing them to access the space without searching for an in-wall switch in the dark. Restrooms Install occupancy sensors in restrooms, locker rooms and other limited-use locations to provide occupants with an added level of comfort and convenience. Adjustable hold intervals make it easy to tailor sensors to application needs, while a manual override function keeps end-users in control. Meeting Rooms and Corridors Simplify lighting control in meeting rooms and hallways with occupancy/ vacancy sensors. A range of commercial-grade solutions allow installers to integrate energy-saving control while catering to business needs. Waiting Rooms and Common Areas Save on energy costs by installing dual-tech occupancy sensors in common areas and waiting rooms. Our ceiling mount solutions provide enhanced coverage and allow the controls to monitor movement in crowded environments with minor obstructions and limited sight lines. Contents Sensor Education .................................................................... 82 Low-Voltage Ceiling Mount ..................................................... 83 Line Voltage Ceiling Mount ..................................................... 84 Commercial Grade In-Wall .................................................... 85 Self Adaptive In-Wall ............................................................... 86 Residential In-Wall .................................................................... 87 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Occupancy Sensors Occupancy Sensors Sensor Education The right technology for the space. Our range of sensors detects the presence and movement of people in a room, space, or immediate vicinity. Smart technology discerns even the slightest motor movements, so lights stay on when needed and turn off when vacated to conserve energy. Ceiling Mount Sensors In-Wall Sensors The differences between Passive Infrared (PIR) and Dual (PIR/Ultrasonic) technology. Passive infrared (PIR) technology detects the difference in heat energy a person in motion generates in contrast to the elements surrounding them in a confined space. To detect presence PIR needs line of sight to a person. Dual (PIR/Ultrasonic) technology combines PIR with Ultrasonic technology. Ultrasonic utilizes wave analysis and Doppler sound waves to detect differences in energy from different phenomenon. The combination of the two technologies enhances responsiveness for maximum system reliability. 82 Occupancy Sensors Low-Voltage Ceiling Mount Occupancy Sensors IOS-CMP-DT-LV IOS-CMP-DT-LV LOW-VOLTAGE CEILING MOUNT DUAL TECH SENSOR This ceiling mount sensor detects presence using a combination of Passive Infrared (PIR) and ultrasonic technologies, and in conjunction with a remote power pack unit, turns the load ON and OFF when presence is detected. APPLICATIONS · Indoor Sensing Control FEATURES · Ultrasonic and PIR sensing for presence detection, even in areas with partitions and/or with small movements · Low-voltage, ceiling mounted sensor · Coverage: 360°, 1600 ft2 PIR, 1000 ft2 Ultrasonic mounted on 8 to 11 ft ceiling · Adjustable time delay · Adjustable ambient light sensor override · Powered by IOS-PP24 power pack, sold separately IOS-CMP-LV IOS-CMP-LV LOW-VOLTAGE CEILING MOUNT PIR SENSOR This ceiling mount sensor detects presence using Passive Infrared (PIR) technology and, in conjunction with a remote power pack unit, turns the load ON and OFF when presence is detected. APPLICATIONS · Indoor Sensing Control FEATURES · PIR sensing for presence detection · Low-voltage, remote-mounted sensor · Coverage: 1200 ft2 when mounted on 8 to 11 ft ceiling · Adjustable time delay · Adjustable ambient light sensor override · Powered by IOS-PP24 power pack, sold separately Model # IOS-CMP-DT-LV Description Commercial Grade Low-Voltage Ceiling Mount Dual Tech Occupancy/Vacancy Sensor, White Technology Dual Technology (PIR/Ultrasonic) Model # IOS-CMP-LV Description Technology Commercial Grade Low-Voltage Ceiling Mount PIR PIR (Passive Infrared) Occupancy/Vacancy Sensor, White 20 TITLE LISTED LED Ratings Input Voltage Current Consumption Power Supply Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x Dia Warranty 24 VDC 20 mA IOS-PP24 1000 ft2 PIR, 1600 ft2 Ultrasonic 10 fc - Daylight 5 sec - 30 min 32°F - 122°F (0°C - 50°C) 1 3/8 x 4 /9 16 (35 mm x 116 mm) 2-Year limited 20 TITLE LISTED LED Ratings Input Voltage Current Consumption Power Supply Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x Dia Warranty 24 VDC 9mA IOS-PP24 1200 ft2 10 fc - 150 fc 15 sec - 30 min 32°F - 122°F (0°C - 50°C) 1 3/8" x 4 9/16" (35 mm x 116 mm) 2-Year limited ACCESSORY IOS-PP24 LED IOS-PP24 LOW-VOLTAGE POWER PACK An IOS-PP24 power pack is required to provide power to the IOS-CMP-LV sensor and enable a manual ON for the vacancy sensor. FEATURES · Controls up to six low-voltage sensors · Zero-crossing technology for long life and performance · Incandescent/Fluorescent/CFL compatible Ratings Input Voltage 120/230/240/277 VAC, 50/60 Hz Tungsten (Incandescent) 15A, 120VAC, 50/60 Hz 5A, 250VAC, 50/60 Hz Ballast (Fluorescent) 20 A Motor 1 HP, 120 VAC, 1 HP, 240 VAC Operating Temperature 32°F - 131°F ( 0°C - 55°C) Dimensions H x W x D 2 3/4" x 1 15/16" x 1 5/8" ( 70 mm x 49 mm x 41 mm) Warranty 2-Year limited 83 Occupancy Sensors Line Voltage Ceiling Mount Occupancy Sensors IOS-CMP-DT-U IOS-CMP-DT-U LINE VOLTAGE CEILING MOUNT DUAL TECH SENSOR IOS-CMP-U IOS-CMP-U LINE VOLTAGE CEILING MOUNT PIR SENSOR Lens 2 IOS-HB-U IOS-HB-U HIGH BAY/FIXTURE MOUNT PIR SENSOR This ceiling mount unit turns lights ON and OFF when presence is detected using a combination of Ultrasonic and Passive Infrared (PIR) sensing technologies. APPLICATIONS · Indoor Sensing Control FEATURES · Ultrasonic and PIR sensing improves presence detection while avoiding false triggers, even in areas with partitions and/or small movements · Zero-crossing technology for long life and performance · Coverage: 360°, 1600 ft2 PIR, 1000 ft2 Ultrasonic mounted on 8 to 11 ft ceiling · Adjustable ambient light sensor override · Requires neutral connection · Incandescent/Fluorescent/CFL/LED compatible Using Passive Infrared (PIR) sensing technology, this ceiling mount unit turns lights ON and OFF when presence is detected in a room without partitions or obstructions. APPLICATIONS · Indoor Sensing Control FEATURES · PIR technology sensing for presence detection · Coverage: 1200 ft2 when mounted on 8 to 11 ft ceiling · Zero-crossing technology for long life and performance · Adjustable ambient light sensor override · Requires neutral connection · Incandescent/Fluorescent/CFL/LED compatible For installation on High Bay Light Fixtures. Provides ON/ OFF control of lights by presence in warehouses and other industrial spaces. APPLICATIONS · Indoor Sensing Control FEATURES · Passive Infrared (PIR) sensing for presence detection · Two lenses included · Coverage: 1200 ft2 (Lens 1) or 2800 ft2 (Lens 2) when mounted at 15 to 50 ft · Zero-crossing technology for long life and performance · Adjustable ambient light sensor override · Incandescent/Fluorescent/CFL/LED compatible Model # Description Technology IOS-CMP-DT-U Commercial Grade Line Voltage Ceiling Mount Dual Tech Occupancy Sensor, White Dual Technology (PIR/Ultrasonic), Zero-crossing Model # Description Technology IOS-CMP-U Commercial Grade Line PIR (Passive Infrared), Voltage Ceiling Mount PIR Zero-crossing Occupancy Sensor, White Model # Description Technology IOS-HB-U Commercial Grade High PIR (Passive Infrared), Bay Ceiling Mount PIR Zero-crossing Occupancy Sensor, White 20 TITLE LISTED LED Ratings Input Voltage 120/277 VAC, 50/60 Hz Electronic Ballast (LED) 800VA,120VAC; 1600VA,277VAC Tungsten (Incandescent) 800 W, 120 VAC Resistive (Heater) 800 W Ballast (Fluorescent) 800 VA, 120 VAC, 1600 VA, 277 VAC Motor 1/4 HP, 120 VAC Coverage Pattern 360°, 1600 ft2 PIR, 1000 ft2 Ultrasonic Adjustable Light Level 10 fc - Daylight Adjustable Time Delay 5 sec - 30 min Operating Temperature 32°F - 131°F (0°C - 55°C) Dimensions H x Dia 1 3/8"x 4 9/16" (35 mm x 116 mm) Warranty 2-Year limited 20 TITLE LISTED LED Ratings Input Voltage 120/277 VAC, 60 Hz Electronic Ballast (LED) 800 VA, 120 VAC; 1600 VA, 277 VAC Tungsten (Incandescent) 800 W, 120 VAC Resistive (Heater) 800 W Ballast (Fluorescent) 800 VA, 120 VAC; 1600 VA, 277 VAC Motor 1/4 HP, 120 VAC Coverage Pattern 360°, 1200 ft2 Adjustable Light Level 10 fc - 150 fc Adjustable Time Delay 15 sec - 30 min Operating Temperature 32°F - 131°F (0°C - 55°C) Dimensions H x Dia 1 3/8" x 4 9/16" (35 mm x 116 mm) Warranty 2-Year limited 20 TITLE LISTED LED Ratings Input Voltage 120/277 VAC, 60 Hz Electronic Ballast (LED) 800 VA, 120 VAC; 1200 VA, 277 VAC Tungsten (Incandescent) 800 W, 120 VAC Resistive (Heater) 800 W Ballast (Fluorescent) 800 VA, 120 VAC; 1200 VA, 277 VAC Motor 1/4 HP, 120 VAC Mounting 15-50 ft Coverage Pattern 180°, 1200 ft2 (Lens 1), 2800 ft2 (Lens 2) Adjustable Light Level 10 fc - 150 fc Adjustable Time Delay 15 sec - 30 min Operating Temperature 32°F - 131°F (0°C - 55°C) Dimensions H x Dia 2 3/4" x 4" (70 mm x 102 mm) Warranty 2-Year limited 84 Occupancy Sensors Commercial Grade In-Wall Occupancy Sensors IOS-DOV-DT-WH IOS-DOV-DT-WH LINE VOLTAGE IN-WALL DUAL TECH SWITCH Ivory IOS-DSR-WH IOS-DSR Series SELF-ADAPTIVE IN-WALL PIR SENSOR SWITCH This Occupancy/Vacancy in-wall switch unit can be used as a replacement to a standard wall switch to turn lights ON and OFF when presence is detected by a combination of Ultrasonic and PIR sensing technologies. APPLICATIONS · Indoor Sensing Control FEATURES · Ultrasonic and Passive Infrared (PIR) sensing for presence detection, even in areas with partitions and/or with small movements · Coverage: 180°, 1200 ft2 PIR, 400 ft2 Ultrasonic · Zero-crossing technology for long life and performance · Adjustable time delay · Optional walk-through detection mode · Adjustable ambient light sensor override · Incandescent/Fluorescent/CFL/LED compatible · Requires neutral connection · Fits standard decorator wall plate (included) These in-wall switches detect presence using PIR sensing technology. They have a self-adjusting feature that optimizes delay-off time based on actual occupancy. APPLICATIONS · Indoor Sensing Control FEATURES · Passive Infrared (PIR) sensing for presence detection · Coverage: 180º, 1200 ft2 with non-obstructed views · User-selectable Vacancy or Occupancy switch mode · Zero-crossing technology for long life and performance · Automatic self-adaptive time delay based on occupancy patterns · IOS-DSR/DDR models feature optional walk-through detection mode · Adjustable ambient light sensor override · Incandescent/Fluorescent/CFL/LED compatible · Fits standard decorator wall plate (included) Model # IOS-DOV-DT-WH Description Commercial Grade In-Wall Dual Tech Occupancy/Vacancy Sensor, White Technology Dual Technology (PIR/Ultrasonic), Zero-crossing Model # White IOS-DSR-WH Ivory IOS-DSR-IV Circuits Switch Type Requires Nightlight Neutral 1 Occupancy, Vacancy No No 20 TITLE LISTED LED Ratings Input Voltage Electronic Ballast (LED) Tungsten (Incandescent) Resistive (Heater) Ballast (Fluorescent) Motor Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x W x D Warranty 120/277 VAC, 50/60 Hz 600 VA, 120 VAC; 1385 VA, 277 VAC 800 W, 120 VAC 800 W, 120 VAC 800 VA, 120 VAC 1/4 HP, 120 VAC 180°, 1200 ft2 PIR, 400 ft2 Ultrasonic 10 fc - Daylight 15 sec - 30 min 32°F - 131°F (0°C - 55°C) 2.625" x 1 5/16" x 1.75" (67 mm x 33 mm x 44 mm) 2-Year limited 20 TITLE LISTED LED Ratings Input Voltage Electronic Ballast (LED) Tungsten (Incandescent) Resistive (Heater) Ballast (Fluorescent) Motor Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x W x D Warranty 120/277 VAC, 50/60 Hz 800 VA, 120 VAC; 1600 VA, 277 VAC 800 W, 120 VAC 800 W, 120 VAC 800 VA, 120 VAC; 1600 VA, 277 VAC 1/4 HP, 120 VAC 180°, 1200 ft2 30 lux - Daylight 15 sec - 30 min 32°F - 131°F (0°C - 55°C) 2.625" x 1 5/16" x 1.75" (67 mm x 33 mm x 44 mm) 2-Year limited 85 Occupancy Sensors Self-Adaptive In-Wall Occupancy Sensors Ivory IOS-DOV-WH IOS-DOV Series SELF-ADAPTIVE IN-WALL PIR SENSOR SWITCH These in-wall switches detect presence using PIR (Passive Infrared Technology) and can be set for Automatic ON or Manual ON activation. These units also offer adjustable time delay, adjustable ambient light level detection, as well as adjustable sensitivity settings providing optimal energy savings. APPLICATIONS · Indoor Sensing Control FEATURES · Passive Infrared (PIR) sensing for presence detection · Coverage: 180º, 1200 ft2 with non-obstructed views · User-selectable Vacancy or Occupancy switch mode · Zero-crossing technology for long life and performance · Adjustable ambient light sensor override · Incandescent/Fluorescent/CFL/LED compatible · IOS-DOV models require a neutral connection · Fits standard decorator wall plate (included) Model # White IOS-DOV-WH Ivory IOS-DOV-IV IOS-DOV-NL-WH* IOS-DOV-NL-IV Circuits 1 1 Switch Type Occupancy, Vacancy Occupancy, Vacancy Requires Nightlight Neutral Yes No Yes Yes 20 TITLE LISTED LED Ratings Input Voltage Electronic Ballast (LED) Tungsten (Incandescent) Resistive (Heater) IOS-DOV IOS-DOV-NL Ballast (Fluorescent) Motor Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x W x D Warranty 120 VAC, 60 Hz 800 VA 800 W 12 A 10 A 800 VA 1/4 HP 180°, 1200 ft2 30 lux - Daylight 15 sec - 30 min 32°F - 131°F (0°C - 55°C) 2.625" x 1 5/16" x 1.75" (67 mm x 33 mm x 44 mm) 5-Year limited 86 IOS-DDR-WH IOS-DDR Series SELF-ADAPTIVE IN-WALL PIR SENSOR SWITCH These in-wall switches detect presence using PIR sensing technology. They have a self-adjusting feature that optimizes delay-off time based on actual occupancy. APPLICATIONS · Indoor Sensing Control FEATURES · Passive Infrared (PIR) sensing for presence detection · Coverage: 180º, 1200 ft2 with non-obstructed views · Independent load control for each circuit · Zero-crossing technology for long life and performance · Automatic self-adaptive time delay based on occupancy patterns · Features optional walk-through detection mode · Incandescent/Fluorescent/CFL/LED compatible · Require a neutral connection · Fits standard decorator wall plate (included) Model # IOS-DDR-WH Circuits 2 Switch Type Requires Neutral Occupancy, Vacancy Yes Nightlight No 20 TITLE LISTED LED Ratings Input Voltage Electronic Ballast (LED) Tungsten (Incandescent) Resistive (Heater) Ballast (Fluorescent) Motor Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x W x D Warranty 120/277 VAC, 50/60 Hz 800 VA, 120 VAC; 1600 VA, 277 VAC 800 W, 120 VAC 800 W, 120 VAC 800 VA, 120 VAC; 1600 VA, 277 VAC 1/4 HP, 120 VAC 180°, 1200 ft2 30 lux - Daylight 15 sec - 30 min 32°F - 131°F (0°C - 55°C) 2.625" x 1 5/16" x 1.75" (67 mm x 33 mm x 44 mm) 5-Year limited Occupancy Sensors Residential In-Wall Occupancy Sensors IOS-DPBIF-WH IOS-DPB Series RESIDENTIAL GRADE IN-WALL PIR VACANCY AND OCCUPANCY SENSOR SWITCHES These in-wall switches detect presence using PIR sensing technology. They provide manual ON and automatic OFF (vacancy switches) or ON/OFF (occupancy switches) for small to medium size rooms. APPLICATIONS · Indoor Sensing Control FEATURES · Passive Infrared (PIR) sensing for presence detection · Adjustable PIR sensitivity · Adjustable time delay 15 sec to 30 min · Adjustable ambient light sensor override for occupancy switch models · Coverage: 150º, 980 ft2 with non-obstructed views · IOS-DPBV models are Incandescent/Fluorescent/CFL/LED compatible and require a neutral connection · 'No neutral' models offered for retrofit applications · Fits standard decorator wall plate (included) Model # Switch Type Requires Electronic Tungsten Ballast Resistive Neutral IOS-DPBIF-WH Occupancy Yes 800 W 800 VA 12 A IOS-DPBIMF-WH* Occupancy No 800 W 800 VA 800 W IOS-DPBV-WH Vacancy Yes 500 VA 500 W 500 VA 10 A *Not compatible with LED load, only incandescent and inductive loads. Min 25 W load required. 20 TITLE LISTED LED Ratings Input Voltage Electronic Ballast (LED) Tungsten (Incandescent) Ballast (Fluorescent) Resistive (Heater) Motor Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x W x D Warranty 120 VAC, 60 Hz See Model Chart - Electronic See Model Chart - Tungsten See Model Chart - Ballast See Model Chart - Resistive 1/4 HP 150°, 980 ft2 30 lux - Daylight 15 sec - 30 min 32°F - 131°F (0°C - 55°C) 2.75" x 1 7/16" x 1.625" (70 mm x 37 mm x 41 mm) 2-Year limited Ivory IOS-DSIF-WH IOS-DSI Series RESIDENTIAL GRADE OCCUPANCY SWITCH WITH MANUAL OVERRIDE These in-wall switches detect presence using PIR sensing technology to automatically turn lights ON/OFF for small to medium size rooms. These models provide users with a manual ON/OFF/AUTO override switch. APPLICATIONS · Indoor Sensing Control FEATURES · Passive Infrared (PIR) sensing for presence detection · Adjustable PIR sensitivity · Adjustable time delay 15 sec to 30 min · Adjustable ambient light sensor override · Coverage: 150º, 980 ft2 with non-obstructed views · IOS-DSIF models are Incandescent/Fluorescent/CFL/LED compatible and require a neutral connection · 'No neutral' models offered for retrofit applications · Fits standard decorator wall plate (included) Model # White Ivory Requires Electronic Tungsten Ballast Resistive Neutral IOS-DSIF-WH IOS-DSIF-IV Yes 500 VA 500 W 500 VA IOS-DSIMF-WH* IOS-DSIMF-IV* No 800 W 800 VA 800 W *Not compatible with LED load, only incandescent and inductive loads. Min 25 W load required. 20 TITLE LISTED LED Ratings Input Voltage IOS-DSIMF Electronic Ballast (LED) Tungsten (Incandescent) Ballast (Fluorescent) Resistive (Heater) Motor IOS-DSIF-WH IOS-DSIMF-WH Switch Type Coverage Pattern Adjustable Light Level Adjustable Time Delay Operating Temperature Dimensions H x W x D Warranty 120 VAC, 60 Hz 120 VAC, 50/60 Hz See Model Chart - Electronic See Model Chart - Tungsten See Model Chart - Ballast See Model Chart - Resistive 1/8 HP 1/4 HP Occupancy 150°, 980 ft2 30 lux - Daylight 15 sec - 30 min 32°F - 131°F (0°C - 55°C) 2.75" x 1 7/16" x 1.625" (70 mm x 37 mm x 41 mm) 2-Year limited 87 Photocontrol Solutions Boost energy efficiency and promote safety in outdoor spaces with Intermatic photocontrols. Our versatile lineup can fit nearly any application and budget. Take advantage of high-performance, LED compatible electronic photocontrols to reduce long-term maintenance needs and deliver lasting value to end-users. Streets and Roadways Install photocontrols in street and roadway lighting applications for dependable dusk-to-dawn control. Our electronic photocontrol solutions are designed to match the 10- to 20-year lifespan of LED fixtures and reduce long-term maintenance needs. Parking Lots and Pathways Deliver simple dusk-to-dawn lighting control in parking lots and other common space applications with our fixed mount electronic photocontrols. These LED compatible solutions are simple to install and promote security. Entranceways and Building Exteriors Take the guesswork out of outdoor building lighting needs with our thermal and electronic photocontrols. These solutions provide reliable ON/OFF scheduling and fit both residential and commercial applications. Parks and Sports Fields Reduce energy waste and promote security in public spaces with our versatile photocontrol lineup. Available in a variety of mounting styles, including stem-and-swivel, button, in-wall and stem mount, these solutions are an ideal choice for parks, sports fields, gardens and more. Contents Product Line Overview ............................................................ 90 Locking Type Electronic ......................................................... 92 Fixed Mount Electronic .......................................................... 93 Locking Type Thermal ............................................................. 94 Fixed Mount Thermal ............................................................. 95 Button and Wall Mount Thermal / Power Tap Receptacle ......... 96 Locking Type Receptacles / Accessories .................................. 97 Customizable Utility Solutions .................................................... 98 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Photocontrols Photocontrols Product Line Overview WHAT'S THE DIFFERENCE BETWEEN THERMAL AND ELECTRONIC PHOTOCONTROLS? ELECTRONIC PHOTOCONTROLS Modern lighting installations require lighting controls that are compatible with LED fixtures. Our NightFoxTM Electronic Photocontrols are specifically designed to match the 10- to 20-year lifespan of LED fixtures, which equates to fewer maintenance service calls and lower equipment costs. NightFox Photocontrols offer a solid-state light sensor and relays that feature zero-crossing technology for more precise control and extended service life. · Higher initial cost but longer lasting · 10- to 20-Year design life · 6- to 12-Year product warranty · Universally compatible, especially with LED fixtures THERMAL PHOTOCONTROLS Thermal Photocontrols are electromechanical switches that are based on a Cadmium Sulphide (CdS) photosensor and a bimetallic, thermally sensitive switch mechanism. These simple switches provide cost-effective dusk-to-dawn control of traditional HID and incandescent lighting loads. Because of their shorter 3- to 5-year design life, they are not recommended due to the high in rush current from LED fixtures which depreciates their lifespan. · Lower initial cost · 3- to 5-Year design life · 1- to 2-Year product warranty · Best for HID and Incandescent Fixtures APPLICATIONS · Street lighting · Perimeter lighting · Landscape lighting · Parking Lot lighting · Pathway lighting · Park and Recreational lighting 90 Photocontrols Photocontrols Product Line Overview NIGHTFOXTM ELECTRONIC PHOTOCONTROLS KEY BENEFITS UNIVERSAL COMPATIBILITY NightFox Photocontrols are designed, tested and warrantied to match the long 10- to 20-year lifespan of LED fixtures. They're also backwards compatible with all traditional light sources (e.g., HID, Incandescent) and compatible with all service voltages (120-277 V, 347V, and 480 V). LOWER MAINTENANCE COSTS A long-life design allows installers to sync photocontrol and fixture maintenance schedules, resulting in fewer nuisance service calls and lower equipment costs. SUPERIOR TECHNOLOGY Built-in zero-crossing technology with high-precision calibration, as well as industry-leading manufacturing processes, helps ensure each photocontrol has a lifespan of 10- to 20-years. FASTER INSTALLATION Verify functionality of newly-installed controls in seconds by covering the sensor (unlike thermal controls which have a delayed ON/OFF trigger). LONG-LIFE WARRANTY All electronic photocontrols are backed by an 8- to 12-year warranty. THE HIDDEN COST OF PHOTOCONTROL MAINTENANCE Pairing an LED fixture with a thermal photocontrol requires installers to make extra trips to the light fixture just to replace the photocontrol. Under ideal conditions, a thermal photocontrol will last just 3-5 years, requiring at least one extra replacement during the life of a typical LED. Often, replacement is required more frequently due to premature failure caused by the high inrush currents of LED drivers. Thermal vs. NightFox Photocontrol Replacement with 15-Year LED Fixture Thermal Photocontrol NightFox Photocontrol LED Fixture 2 4 6 8 10 12 14 16 Time (Years) Photocontrol Replacement Cost: Two- or three-man crew, lift equipment, service call (approximately one hour) 91 Photocontrols Locking Type Electronic Photocontrols NIGHTFOXTM SPECIFIER GRADE LED4536SC LED4537SC NIGHTFOXTM SELECT GRADE EK4536 EK4537 NIGHTFOXTM STANDARD GRADE ELC4536 Photocontrol specifically designed for 20-year service to match the life expectancy of long-life LED and new induction fixtures. FEATURES · Non-drift silicon light sensor with IR filter · DC relay with zero-crossing circuitry for extended life · All components meet 20-year life expectancy · Conformal coated PCB · Exceeds 15,000 ON/OFF switching cycles · Ideal for single or multi-fixture HID and LED installations (up to 2,220 W @ 277 VAC) · 510 J MOV surge protection Designed to meet a 15-year service life, this photocontrol is LED-compatible and backed by an 8-year warranty. FEATURES · Non-drift silicon light sensor with IR filter · DC relay with zero-crossing circuitry for extended life · All components meet 15-year life expectancy · Conformal coated PCB · Exceeds 10,000 ON/OFF switching cycles · Ideal for single or multi-fixture HID and LED installations (up to 1,650 W @ 277 VAC) · 510 J MOV surge protection LED-compatible photocontrol features a 10-year life expectancy. Ideal for single fixture control of smaller LED fixtures that require a cost-effective solution. FEATURES · Non-drift silicon light sensor with IR filter · All components meet 10-year life expectancy · Exceeds 5,000 ON/OFF switching cycles · Ideal for single HID and LED fixtures (up to 550 W @ 277 VAC) · 510 J MOV surge protection FOR ALL MODELS ABOVE Model # Warranty Input Voltage LED4536SC LED4537SC EK4536 EK4537 ELC4536 12-Year limited 12-Year limited 8-Year limited 8-Year limited 6-Year limited 120-277 VAC, 50/60 Hz 347/480 VAC, 50/60 Hz 120-277 VAC, 50/60 Hz 347/480 VAC, 50/60 Hz 120-277 VAC, 50/60 Hz Electronic Ballast Tungsten (LED) (Incandescent) 8 A, 120-277 VAC, 1000 W 50/60 Hz 2A, 347 VAC, 50/60 Hz 1000 W 6 A, 120-277 VAC, 1000 W 50/60 Hz 2 A, 347 VAC 2 A, 1000 W 347 VAC 2 A, 120-277 VAC, 1000 W 50/60 Hz Ballast (Fluorescent) 1800 VA 1800 VA 1800 VA 1800 VA 1800 VA 20 TITLE LISTED LED Induction HID Ratings Input Voltage Electronic Ballast (LED) Tungsten (Incandescent) Ballast (Fluorescent) Activation On Activation Off Time Delay Dimensions H x Dia Operating Temperature Warranty See Model Table See Model Table 1000 W 1800 VA 1.5 fc 2.25 fc Instant ON; 2 sec to 5 sec OFF 2.75" x 3.375" (69.9 mm x 85.8 mm) -40°F - 158°F (-40°C - 70°C) See Model Table 92 Photocontrols Fixed Mount Electronic Photocontrols EK4036S EK4336S Fixed Mount Electronic Photocontrols NIGHTFOXTM EK4000 SERIES NightFoxTM electronic photocontrols permanently install on outdoor electrical boxes, in-wall boxes or outdoor lighting fixtures. Ideal for LED and induction fixtures with long-life expectations. ½"-14 NPSM threaded stem fits standard outlet boxes and wall packs with 9" wire leads. FEATURES · Non-drift silicon light sensor with IR filter · DC relay with zero-crossing circuitry for extended life · Conformal coated PCB · 15-year design life · Exceeds 10,000 ON/OFF switching cycles · Fail ON mode · Ideal for single or multi fixture HID and LED installations (up to 1,650 W @ 277 VAC) · 255 J MOV surge protection element · Mounts internally to enclosure · Features 3/8" - 18 NPSM thread for a minimum installation hole size of 5/8 inch diameter EK4136S EK4436SM EK4236S EK4736S 20 TITLE LISTED LED Induction HID Ratings Input Voltage Electronic Ballast (LED) Tungsten (Incandescent) Activation On Activation Off Time Delay MOV* Fail Mode Wire Leads Dimensions H x W x D Button Stem Plastic Stem Metal Stem & Swivel Operating Temperature Warranty * Metal Oxide Varistor See Model Table See Model Table 1000 W 1.5 fc 4.5 fc Instant ON; 2 sec to 5 sec OFF 220 J MOV, 5,000 A Surge ON #18 AWG 2 1/4" x 1 5/16" x 1 1/4" (57.2 mm x 33.3 mm x 31.8 mm) 2 1/4" x 1 5/16" x 1 1/4" (57.2 mm x 33.3 mm x 31.8 mm) 2 11/16" x 1 3/4" x 2 3/16" (68.3 mm x 44.5 mm x 55.6 mm) 5 5/8" x 1 5/16" x 1 1/4" (142.9 mm x 33.3 mm x 31.8 mm) -40°F - 158°F (-40°C - 70°C) 8-Year limited Model # Style Lens Input Location Voltage Electronic Ballast (LED) Wire Lead (in) EK4027S Button Front 347 VAC, 2 A 9" 50/60 Hz EK4035S Button Front 480 VAC, 0.35 A (Tested with 150 W 9" 50/60 Hz 480 V LED driver with 120 Apk /100µs In-rush current) EK4036S Button Front 120-277 VAC, 6 A, 120-277 VAC, 50/60 Hz 9" 50/60 Hz EK4127S Stem Mount Side 347 VAC, 2 A 9" 50/60 Hz EK4135S Stem Mount Side 480 VAC, 50/60 Hz 0.35 A (Tested with 150 W 9" 480 V LED driver with 120 Apk /100µs In-rush current) EK4136S Stem Mount Side 120-277 VAC, 6 A, 120-277 VAC, 50/60 Hz 9" 50/60 Hz EK4227S Stem and Side 347 VAC, 2 A 6" Swivel Mount 50/60 Hz EK4235S Stem and Side Swivel Mount 480 VAC, 50/60 Hz 0.35 A (Tested with 150 W 6" 480 V LED driver with 120 Apk /100µs In-rush current) EK4236S Stem and Side Swivel Mount 120-277 VAC, 6 A, 120-277 VAC, 50/60 Hz 6" 50/60 Hz EK4336S In-Wall Front 120-277 VAC, 6 A, 120-277 VAC, 50/60 Hz 9" 50/60 Hz EK4436SM Stem Mount Side 120-277 VAC, 6 A, 120-277 VAC, 50/60 Hz 9" 50/60 Hz EK4736S Stem and Top Swivel Mount 120-277 VAC, 6 A, 120-277 VAC, 50/60 Hz 6" 50/60 Hz 93 Photocontrols Locking Type Thermal Photocontrols LC4521LA Locking Type Thermal Photocontrols LC4500 SERIES These photocontrols install on light fixtures with ANSI C136.10 NEMA receptacles commonly found on street light fixtures. Locking type design facilitates fast installation and replacement of photocontrol. FEATURES · Mechanical bimetal switch with Cadmium Sulfide photocell · Integral high impact thermoplastic housing · Locking type plug for quick installation and changeover · Delay feature prevents unwanted OFF switching · Complies with ANSI C136.10 standard · Tested to 3,650 ON/OFF cycles Model # Input Voltage Ballast Tungsten Protection (Fluorescent) (Incandescent) LC4521C 120 VAC, 50/60 Hz 8.3 A, 1000 VA 15 A, 1800 W LC4523 208-277 VAC, 50/60 Hz 8.3 A, 15 A, 1700-2300 VA 3100-4150 W LC4527* 347 VAC, 50/60 Hz 8.3 A, 2880 VA 15 A, 5205 W None LC4535 480 VAC, 50/60 Hz 8.3 A, 4000 VA 15 A, 7200 W LC4536C 120-277 VAC, 50/60 Hz 8.3 A, 15 A, 1000-2300 VA 1800-4155 W LC4521LA 120 VAC, 50/60 Hz 8.3 A, 1000 VA 15 A, 1800 W LC4523LA LC4535LA 208-277 VAC, 50/60 Hz 8.3 A, 15 A, 1700-2300 VA 3100-4150 W 480 VAC, 50/60 Hz 8.3 A, 4000 VA 15 A, 7200 W Spark Gap Surge Arrestor LC4536LAC 120-277 VAC, 50/60 Hz 8.3 A, 15 A, 1000-2300 VA 1800-4155 W * LC4527 is only CSA 20 TITLE LIISndTEucDtion HID Ratings Input Voltage Ballast (Fluorescent) Tungsten (Incandescent) Activation On Activation Off Operating Temperature Dimensions H x Dia Warranty See Model Table See Model Table See Model Table 5 fc 15 fc -40°F - 158°F (-40°C - 70°C) 2 3/4" x 3" (69.9 mm x 76.2 mm) 2-Year limited LC2100 Low-Cost Multivoltage Locking Type Thermal Photocontrols LC2000 SERIES This model combines a silicon diode photosensing element with thermal switch to provide a multivoltage, cost-effective photocontrol. FEATURES · Mechanical bimetal switch with Silicon Diode photocell · Thermoplastic housing with window · Multivoltage covers 120 to 277 VAC applications · Complies with ANSI C136.10 Model # LC2100 Input Voltage 120-277 VAC, 50/60 Hz Ballast (Fluorescent) 1800 VA Tungsten (Incandescent) 1000 W Induction HID Ratings Input Voltage Ballast (Fluorescent) Tungsten (Incandescent) Activation On Activation Off Operating Temperature Dimensions H x Dia Warranty 120-277 VAC, 50/60 Hz 1800 VA 1000 W 1.5 fc 6 fc -40°F - 158°F (-40°C - 70°C) 2 7/32" x 3" (56.4 mm x 76.2 mm) 2-Year limited 94 Photocontrols Fixed Mount Thermal Photocontrols K4121C K4423M Stem Mount Thermal Photocontrols K4100 AND K4400 SERIES These photocontrols install on standard outdoor light fixtures and electrical boxes with 1/2"-14 NPSM thread or 7/8" knock-out holes for dusk-to-dawn ON/OFF control of outdoor lighting. FEATURES · Mechanical bimetal switch with Cadmium Sulfide photocell · Delay feature prevents unwanted OFF switching · Plastic and die-cast metal housing options · 1/2"-14 NPSM threaded stem · Washer gasket and locking nut included · #18 AWG, 9" wire leads Model # Input Voltage K4121C K4141C* K4123C 120 VAC, 50/60 Hz 120 VAC, 50/60 Hz 208-277 VAC, 50/60 Hz K4421M 120 VAC, 50/60 Hz K4423M 208-277 VAC, 50/60 Hz * K4141C is not UL/CSA certified. Ballast (Fluorescent) 8.3 A, 1000 VA 25 A, 3000 VA 8.3 A, 1700-2300 VA 8.3 A, 1000 VA 8.3 A, 1700-2300 VA Tungsten (Incandescent) 15 A, 1800 W 25 A, 3000 W 15 A, 3100-4150 W 15 A, 1800 W 15 A, 3100-4150 W Housing Polycarbonate Die-Cast Zinc K4221C K4251 Stem and Swivel Mount Thermal Photocontrols K4200 SERIES These photocontrols are provided with a swivel arm for easy and flexible installation to standard outdoor light fixtures or electrical boxes. FEATURES · Mechanical bimetal switch with Cadmium Sulfide photocell · Delay feature prevents unwanted OFF switching · High strength, UV resistant plastic housing · Swivel with 1/2"-14 NPSM threaded stem · Washer gasket and locking nut included · #18 AWG, 6" wire leads Model # Input Voltage Ballast (Fluorescent) Tungsten (Incandescent) Sensor Location K4221C 120 VAC, 50/60 Hz 8.3 A, 1000 VA 15 A, 1800 W K4223C 208-277 VAC, 50/60 Hz 8.3 A, 1700-2300 VA 15 A, 3100-4150 W Side K4236C 120-277 VAC, 50/60 Hz 8.3 A, 1000-2300 VA 15 A, 1800-4150 W K4251* K4253* 120 VAC, 50/60 Hz 8.3 A, 1000 VA 15 A, 1800 W Top 208-277 VAC, 50/60 Hz 8.3 A, 1700-2300 VA 15 A, 3100-4150 W * K4253, K4251 is only CSA. FOR ALL MODELS ABOVE 20 TITLE L E D InLdISuTcEtiDon HID Ratings Input Voltage Ballast (Fluorescent) Tungsten (Incandescent) Activation On Activation Off Operating Temperature Wire Leads Dimensions H x W x D Warranty See Model Table See Model Table See Model Table 1 to 5 fc 3 to 15 fc -40°F - 158°F (-40°C - 70°C) #18 AWG, 9" L 3" x 1 9/16" x 1 9/16" (76.2 mm x 39.7 mm x 39.7 mm) 2-Year limited, 1-Year limited for K4251, K4253 & K4141C 95 Photocontrols Button and Wall Mount Thermal / Power Tap Receptacle Photocontrols K4021C Button and Wall Mount Thermal Photocontrols K4000 SERIES K4321C NightFoxTM electronic photocontrols permanently install on outdoor electrical boxes, in-wall boxes or outdoor lighting fixtures. Ideal for LED and induction fixtures with long-life expectations. ½"-14 NPSM threaded stem fits standard outlet boxes and wall packs with 9" wire leads. FEATURES · Mechanical bimetal switch with Cadmium Sulfide photocell · Compact size fits into standard outlet box, post lamp, wall pack and other lighting fixtures · Delay feature prevents unwanted OFF switching · 3/8" - 18 NPSM, 3/4" long stem with locking nut and washer gasket KPT1170-010 PowerTap Receptacle KPT0170-010 KPT0170-015 KPT1170-010 APPLICATIONS · Power Extension · Traffic Control FEATURES · 7-pin ANSI C 136.41 connector interface · 3-prong power sockets + 4 signal contacts · Taps into electric supply line of photocontrol with a #16 AWG cable out · Branch circuit protected by an auto-resetting 10 A, OCPD · Does not disturb the operation of lighting control units Model # K4021C K4023C K4321C Style Button Button In-Wall Input Voltage 120 VAC, 50/60 Hz 208-277 VAC, 50/60 Hz 120 VAC, 50/60 Hz Ballast (Fluorescent) 8.3 A, 1000 VA 8.3 A, 1700-2300 VA 8.3 A, 1000 VA Tungsten (Incandescent) 15 A, 1800 W 15 A, 3100-4150 W 15 A, 1800 W Model # KPT0170-010 KPT0170-015 KPT1170-010 Description PowerTap Receptacle, 7-Pin, C136.41 Compliant, Always-On, 10' cable PowerTap Receptacle, 7-Pin, C136.41 Compliant, Always-On, 15' cable PowerTap Receptacle, 7-Pin, C136.41 Compliant, Dusk-to-Dawn, 10' cable LED Induction HID 20 TITLE LISTED Ratings Input Voltage Ballast (Fluorescent) Tungsten (Incandescent) Activation On Activation Off Operating Temperature Wire Leads Dimensions H x W x D Warranty See Model Table See Model Table See Model Table 1 to 5 fc 3 to 15 fc -40°F - 158°F (-40°C - 70°C) #18 AWG, 9" L 1 13/16" x 15/16" x 13/16" (46 mm x 23.8 mm x 20.6 mm) 2-Year limited Ratings Branch Circuit Protection 120 V, 10 A, Auto-resetting Thermal Circuit Breaker Branch Circuit Rating 120 VAC, 5 A max Signal Contacts Rating 30 VDC, 0.25 A max Power Contacts Rating 120 V, 15 A max total (luminaire plus branch circuit power) Power Derating 5 A from -40° C to 50° C, derate at 0.1 A/° C above 50° C up to 70° C max Line Out Cable STOOW Cord, .314" (8mm) OD, 10 ft. long Wire Leads (2) #16 AWG, Flush Cut Operating Temperature -40°F - 158°F (-40°C - 70°C) Warranty 2-Year limited 96 Photocontrols Locking Type Receptacles / Accessories ACCESSORIES Photocontrols SK4500K Shorting and Open Plug for Locking Type Receptacles SK4500K OK4500R FEATURES · Fits standard locking-type receptacles · Polycarbonate housing · Works for all voltages · Keeps lights permanently ON or OFF OK4500R 6LV1352 K43-WP-KIT 22LG0120 LGLBL K121/K121-30 K122 Model # SK4500K SK4500KJ OK4500R OK4500RJ Description The SK4500K Shorting Cap is a low-profile, locking-type photocontrol cap that closes the receptacle connectors of individual fixtures. This cost-effective solution allows a series of lights to perform as a collective unit (ON/OFF) while protecting the receptacle from outdoor elements. Shorting Plug for Locking Type Receptacles, bulk pack Open Cap for Locking Type Receptacles Open Cap for Locking Type Receptacles, bulk pack Ratings Operating Temperature Dimensions H x Dia Warranty -40°F - 158°F (-40°C - 70°C) 1.5" x 3.25" (38.1 mm x 82.55 mm) 2-Year limited K42-SW-A K171H K121-GSKT Model Number 6LV1352 22LG0120 22LG116 K121 K121-30 K121-GSKT K171H K122 K42-SW-A K43-WP-KIT LGLBL Description Light Shield Accessory for EK4036S, EK4436SM, K4000 Series Button Photocontrols Light Guard Accessory for EK4000 Series Electronic Fix Mount Photocontrols Light Guard Accessory for K4100 Series, K4200 Series Thermal Photocontrols Locking Type Receptacle, 3-Pin, C136.10 Compliant, 9" lead Locking Type Receptacle, 3-Pin, C136.10 Compliant, 30" lead Locking Type Receptacle Gasket Locking Type Receptacle, 7-Pin, C136.41 Compliant, 12" lead Locking Type Receptacle, 3-Pin, C136.10 Compliant, with Pole Mounting Bracket Swivel Arm Accessory for EK4136S, K4100 Series Stem Mount Photocontrols Wall Plate Kit for EK4036S, K4000 Series Button Photocontrols Lens Sticker Accessory for EK4000 & K4000 Series Photocontrols Slim New Look, Rugged Performance Introducing New Low-Profile Shorting and Open Cap Solutions Upgrade outdoor photocontrols with the new SK4500K Shorting Cap and OK4500R Open Cap from Intermatic. The locking-type plug connectors are a simple, cost-effective solution to protect outdoor fixtures, or control photocontrol ON/OFF patterns in multi-fixture installations. Both solutions are ANSI C136.10 compliant, delivering long-term value without sacrificing aesthetics. Available in 50-unit bulk quantities. 97 Photocontrols Photocontrols Customizable Utility Solutions Quality Customizable Solutions, Long-Lasting Performance As a leading manufacturer of photocontrols, contactor boxes and accessories, Intermatic understands the technology needed to meet modern lighting specifications. Our NightFox Pro Series was designed from the ground up to match the life expectancy of LED lighting fixtures. We did this by pioneering a comprehensive testing methodology that uses the best information from NEMA 410 and UL standards to ensure LED compatibility and verify life target expectations. Moreover, our state-of-the-art ISO 9001:2015 certified, vertically integrated manufacturing facility helps us maintain rigorous manufacturing standards while keeping all aspects of production under one roof. Our team oversees everything from the metal stamping of terminals and injection molding of plastic parts to circuit board assembly, testing and calibration. We're committed to quality, and this allows us to confidently stand behind our work, with warranties of up to 12 years on select lighting controls. Seamless Integration with Customizable Contactor Controls Simplify your next project with a Pro Series Contactor Box that's designed to fit your unique requirements. Our tailored solutions are ideal for a variety of indoor and outdoor lighting applications, including switching of LED or ballast lamp loads. We are in a position to provide a solution to your Lighting Control requirements. Avoid costly maintenance issues in roadway lighting applications by installing LED-rated NightFoxTM photocontrols. Our flagship photocontrol solution can be tailored to a variety of specifications and provides reliable dusk-to-dawn lighting control. Simplify lighting schedules in parks, shopping districts and other outdoor spaces by upgrading to NightFoxTM photocontrols. The easy-to-install dusk-to-dawn controls are designed to match the long 10- to 20-year lifespan of LED fixtures. Leverage existing light pole infrastructure and provide power to auxiliary devices with cost-effective Intermatic solutions. Our receptacle connectors make it easy to integrate holiday lighting, communication equipment, sensors and more in municipal applications. 98 Photocontrols Customizable Utility Solutions Photocontrols NightFoxTM Pro Series CUSTOMIZABLE ELECTRONIC PHOTOCONTROLS Say Goodnight to LED Photocontrol Maintenance NightFox Pro Photocontrols can be customized to meet the exact needs and specifications developed by Municipalities, Utilities, and Co-Ops. Many Municipalities, Utilities and Co-Ops have developed specifications based on their own best practices, experience and particular needs. With the NightFox Pro Series Portfolio, there's no need to compromise. We'll build our photocontrols according to your specifications. FEATURES · 10- to 20-year design life · Tested to full ON/OFF lifecycles under LED and induction loads per NEMA 410 · Tested up to 15,000 life cycles · Up to 12-year warranties · 120-277 or 347-480 voltage ranges · Zero-crossing electronic circuitry minimizes the impact of inrush current · Conformal coated PCB assemblies · Non-drift silicon light sensor with IR filter · Enhanced customizable surge protection with up to 1020 J MOV components · Meet or exceed ANSI C136.10 and UL/CSA requirements · Fail ON or Fail OFF options · North-facing or omni-directional light sensor location options · Nine ANSI C136.10 color-coded covers available · NEMA 3 · ON/OFF from 1.0 to 8.0 foot-candle activation levels for overall energy saving potential CONFIGURABLE OPTIONS 1. MODEL SERIES -- Choose the base model that best meets your application. · Standard Grade (ELC series) 6-year warranty, 10-year design life, 2 A LED driver rating, +5,000 ON/OFF switching cycles · Select Grade (EK series) 10-year warranty, 15-year design life, 6 A LED driver rating, zero-crossing technology, +10,000 ON/OFF switching cycles · Specifier Grade (LED series) 12-year warranty, 20-year design life, 8 A LED driver rating, zero-crossing technology, +15,000 ON/OFF switching cycles 2. CONFIGURATION -- Select the enclosure type and sensor mount location. · NEMA 3 · North-Facing or Omni-Directional Light Sensor Location 3. VOLTAGE RATINGS -- 120-277 V or 347-480 V 4. FAIL MODE -- Fail ON or Fail OFF modes 5. LOAD RATINGS -- See Model Series 6. CUSTOM ON AND OFF LIGHT ACTIVATION LEVELS · Adjustable to any ON or OFF light activation level from 1.0 to 8.0 foot-candles 7. SURGE PROTECTION -- select between two levels: · 510 J MOV / ANSI C136.2 `Enhanced' surge protection level · 1020 J MOV / ANSI C136.2 `Extreme' surge protection level 8. COVER COLORS -- 9 cover color options. Utility Control Boxes CUSTOMIZABLE UTILITY CONTROL BOXES Example Indoor and Outdoor Lighting Application Options Professionally designed and built lighting contactor boxes provide a pre-configured, high quality control box for a quick field installation and deployment of your lighting project. Our Lighting Contactor Controls are a simple, integrated solution to fit your specific indoor and outdoor lighting applications, including switching of LED or Ballast lamp loads. Made in the USA. CONFIGURABLE OPTIONS · 30 A-400 A · 1-4 Poles · NEMA 4X Enclosure (metal, non-metal) · Line voltage 120 V-600 V or Multiple-in-One (120/240 V & 277/480 V) · Photocontrol and receptacle · Circuit protection · Surge protection · Zero-cross solid state relay (30 A & 60 A) · Separate control voltage · talento smartTM control APPLICATIONS · New LED Projects · Industrial plants · Street lighting · Commercial Shopping Centers · Billboards · Hospitals · Stadiums · Schools, Universities and Community Colleges · Roadways · Parking Lots · Residential · Automobile Dealerships · Airports · Substations INTERESTED IN A CUSTOMIZED SOLUTION? For more information contact your Intermatic utility representative today to discuss selecting options, pricing and lead time or send an email to utility sales@intermatic.com and a representative will respond. DON'T FORGET THE POWERTAP Please see page 96 for information on Intermatic's PowerTap Receptacle, the perfect addition to your utility solutions! 99 Hour Meter Solutions Ensure accurate run time and load usage measurements with our wide selection of hour meters. Available in a variety of mounting styles, including DIN rail, panel, surface and flush mount. Equipment Monitoring Stay on top of equipment maintenance schedules by installing a versatile Intermatic hour meter. Designed to accurately monitor run times and load usage measurements for tens of thousands of hours, these solutions help avoid premature equipment failures and simplify routine maintenance. Rugged Durability The wide -40° F to 160° F operating temperature range found in UWZ and FWZ series hour meters allows the controls to withstand intense weather conditions without issue. This makes them an ideal solution for rigorous outdoor applications, particularly in high-stress climates. High Visibility Displays Improve meter reading accuracy and speed using the vibrant, rolling digits found on Intermatic hour meters. UWZ series solutions include a high-visibility orange tenths digit, while FWZ and GZ Series solutions offer yellow hundredths and tenths numerals. Flexible Mounting Options Panel-mount hour meters can be placed in the opening of a control panel with the face remaining visible from the outside, whereas surface-mount hour meters are commonly screwed to flat surfaces. Our simple-to-install DIN rail-mounted solutions (UWZ series) are designed to be secured to a rail. Contents AC Hour Meters (Non-Reset Type) .................................... 102 DC & Vibratory Hour Meters (Non-Reset Type) / AC Hour Meters (Non-Reset Type) ........................................................... 103 AC Hour Meters (Non-Reset Type) and Accessories ......... 104 Dimensional Drawings .................................................... 105 Hour Meters Hour Meters AC Hour Meters (Non-Reset Type) The FWZ Series AC Hour Meters are flush panel mountable designed to fit into tight locations. They are non-resettable with watertight/dust-tight sealed bezels designed to withstand IP54 environmental rating (with use of a gasket). All models are black plastic (except FWZ72B which is blue-silver on colorless frosted polycarbonate) with white numerals on a black background. Tenths and hundredths numerals are yellow. FWZ55 Series FLUSH, PANEL Ratings Voltage Available 120 or 240 VAC Frequency 60 Hz Power Consumption 1 VA Bezel H x W 1.18" x 2.17" (30 mm x 60 mm) Capacity 99999.99 hours Numerals 0.16" high numerals Operating Temperature -40°F - 160°F (-40°C - 72°C) Electrical Connection Combination 1/4" spade and screw clamp, Rear access screw terminals available (Model "K") Panel Opening H x W 1.08" x 2.06" (27.5 mm x 52 mm) Mounting Flush panel retainer mounted with slip-on retaining bracket Material Black Plastic Ordering Information FWZ55 + K* + Desired Voltage + Frequency + U Warranty 1-Year limited * Rear access screw terminals ORDERING EXAMPLE To build a model #, choose the Hour Meter Series at the frequency you want. Add a "K" suffix for rear access screw terminals (on applicable models). Then specify voltage. Only 50 Hz models need to be denoted in the model #. Non "U" models indicate bulk pack. Voltages not currently available will be considered on a case by case basis. Series + K + VAC + Hz + U = Model # FWZ55 + K + 240 + 60 + U = FWZ55K-240 FWZ72 Series FLUSH PANEL MOUNT Ratings Voltage Available 24, 120 or 240 VAC Frequency 60 Hz Power Consumption 1 VA Bezel 2.83" round (72 mm), 3-Hole Capacity 99999.99 hours Digits 0.16" ( 4.1 mm) high numerals Operating Temperature -40°F - 160°F (-40°C - 72°C) Electrical Connection Combination 1/4" spade and screw clamp, Rear access screw terminals available (Model "K") Panel Opening Round Rectangular 1.75" (44.4 mm) 1" x 1.5" (24 mm x 38 mm) Mounting Flush panel retainer mounted (3) 0.185" holes for #8 screws Material FWZ72 FWZ72K FWZ72B FWZ72C 24 or 120 VAC Black Plastic 240 VAC Black Plastic 120 or 240 VAC Blue and Silver on Frosted Clear Polycarbonate 120 VAC Clear Frosted Plastic Gasket Model # G-72U (sold separately) Ordering Information FWZ72 + Suffix K*, B, or C + Desired Voltage + Frequency + U Warranty 1-Year limited * Rear access screw terminals ORDERING EXAMPLE To build a model #, choose the Hour Meter Series at the frequency you want. Add a "K" suffix for rear access screw terminals (on applicable models). All models are 60 Hz. Add a "B"... Add a "C"... Then specify voltage. Non "U" models indicate bulk pack. Voltages not currently available will be considered on a case by case basis. Series + K, B or C + VAC + U = Model # FWZ72 + B + 240 + U = FWZ72B-240U 102 Hour Meters DC & Vibratory Hour Meters (Non-Reset Type) / AC Hour Meters (Non-Reset Type) Hour Meters GZ40AU Series FLUSH MOUNT The GZ Series DC Hour Meters are the answer to applications requiring low power load usage metering. Compact, tamper-proof GZ40 meters are sealed against the environment (IP rated up to IP66) to provide years of service. Accumulated load usage hours are stored in the mechanical indicating counter; therefore, no battery is required to maintain elapsed time. An input diode provides polarity protection. A quartz crystal time base ensures accurate, long-term timekeeping. Ratings Voltage Available 10-80 VDC Power Consumption 0.03W, 12 VDC, 0.7W, 48VDC Bezel 2.31"(59 mm), SAE Capacity 99999.9 hours Digits/Display 0.125" (3.2 mm) high numerals Hours Color White on Black Tenths Color Red on White Vibration Resistance 1-8 g, 10-75 Hz Operating Temperature -22°F - 150°F (-30°C - 65°C) Electrical Connection 1/4" Spade termination Mounting Flush with Bracket Protected From Reverse Polarity, Inductive Switching Environmental Rating IP66 Warranty 1-Year limited UWZ48 Series PLUG-IN SURFACE MOUNT The UWZ48 Surface Mount Hour Meter uses a plug-in base where terminal protection is not necessary. The socket base is easy to install and connect. Simply plug the meter into the base and secure with a screw. Ratings Voltage Available 24, 120 or 240 VAC Frequency 60 Hz Power Consumption 1 VA Bezel H x W 1.89" x 1.89" (48 mm x 48 mm) Capacity 99999.99 hours Digits 0.16" high numerals Operating Temperature -40°F - 160°F (-40°C - 72°C) Electrical Connection Screw lugs Mounting Surface Material Light Gray Plastic Ordering Information UWZ48 + Desired Voltage + U Warranty 1-Year limited ORDERING EXAMPLE To build a model #, choose the Hour Meter Series at the voltage you need and add a U suffix. Non "U" models indicate bulk pack. All models are 60 Hz. Series + VAC + U = Model # UWZ48 + 240 + U = UWZ48-240U Counting Down to Your Next Project FWZ SERIES Each of the three hour meter categories offers a unique set of features and benefits. Panel-mount hour meters are placed in the opening of a control panel with the face remaining visible from the outside, whereas surface-mount hour meters are commonly screwed to flat surfaces. DIN rail-mounted solutions (UWZ series) are designed to be secured to a rail or placed within a DIN rail control box. Scan the qr code for a list of all available products. UWZ SERIES GZ SERIES · Accommodates flush- or panel-mount applications · 24, 120, 220 or 240 VAC (depending upon model) · Accurate at 99,999.99 (tenths and hundredths place value) · P54 protection rating · Non-resettable Scan the qr code for a list of available products. · Accommodates surface-mount, enclosed surface-mount and DIN rail-mount applications · 24, 120 or 240 VAC (depending upon model) · Accurate at 99,999.99 (tenths and hundredths place value) · Ideal for electrical panel applications · IP20 rating for Indoor applications · Non-resettable · Round flush-mount design · Available from 8 VDC to 80 VDC (depending on model) · Monitors activity up to 100,000 hours · Accurate at 99,999.99 (tenths place value) · Quartz crystal for enhanced timing accuracy · Protection rating up to IP66 · Non-resettable 103 Hour Meters AC Hour Meters (Non-Reset Type) and Accessories Hour Meters UWZ48V Series DIN RAIL MOUNT A special snap-on socket base allows for fast positioning onto a DIN rail. Compliant Ratings Voltage Available Frequency Power Consumption Bezel H x W Capacity Digits Operating Temperature Electrical Connection Mounting Material Ordering Information Warranty 24 or 120 VAC 60 Hz 1 VA 1.89" x 1.89" (48 mm x 48 mm) 99999.99 hours 0.16" high numerals -40°F - 160°F (-40°C - 72°C) Combination 1/4" spade and screw clamp DIN Rail Light Gray Plastic UWZ48V + Desired Voltage + U 1-Year limited ORDERING EXAMPLE To build a model #, choose the Hour Meter Series at the frequency you want. Then specify voltage and add a U suffix. Non "U" Models indicate bulk pack. All models are 60 Hz. Series + VAC + U = Model # UWZ48V + 240 + U = UWZ48V-24U UWZ48E Series FLUSH MOUNT Flush mounted with bracket, the UWZ48E unit fits into a 1.79" x 1.79" (45.5 x 45.5 mm) cutout. The thickness of the panel for flush mounting can be up to .35" (9 mm). The unit is secured in position by a plastic slip-on retaining bracket. The unit also fits square or round openings for 72 mm with optional 72 mm bezel. Compliant Ratings Voltage Available 24, 120 or 240 VAC Frequency 60 Hz Power Consumption 1 VA Bezel H x W 1.89" x 1.89" (48 mm x 48 mm) Capacity 99999.99 hours Digits 0.16" high numerals Operating Temperature -40°F - 160°F (-40°C - 72°C) Electrical Connection 1/4" Spade w/ screw clamp Mounting Flush Material Light Gray Plastic Ordering Information UWZ48E + Desired Voltage + Frequency + U Warranty 1-Year limited ORDERING EXAMPLE To build a model #, choose the Hour Meter Series at the frequency you want. Then specify voltage and add a U suffix. Non "U" Models indicate bulk pack. Only 50 Hz models need to be denoted in the model #. Select: Series + VAC + Hz = Model # 60 Hz Models: UWZ48E + 24 + (60) = UWZ48E-24U DIN Rail Mounting Base for UWZ48E UWZ ACCESSORIES 55 mm Bezel for UWZ48E 72 mm Bezel with 3 Pins for round 3-bolt hole opening for UWZ48E MB-48V 104 BEZ-55BLACKU BEZ-55GRAYU BEZ-72PU Gray Hour Meters Dimensional Drawings Hour Meters DIMENSIONS FWZ55 Series .20" [5mm] 2.36" [60 mm] 2.17"[55 mm] 120° 1.36" [34.5 mm] 1.18" [30 mm] DIMENSIONS FWZ72 Series 2.5" [63.4 mm] 2.84" [7122.20°mm] 2.2" [55.8 mm] 1.75" [44.5 mm] 2.5" [63.4 mm] 2.84" [72.2 mm] 2.2" [55.8 mm] 2.05" [52 mm] 0.185" [4.7 mm] .28" [7 mm] 1.97" [50 mm] SCREW TO ATTACH TO MOUNTING PLATE 0.98" [25 mm] 1.88" (47.75 mm) 0.2" [5 mm] 120° 2.106" [53.5 mm] 0.185" [4.7 mm] 2.5" [63.4 mm] 0.28" [7 mm0].2" [5 mm] 2.106" [53.5 mm] 2.84" [72.2 mm] 2.2" [55.8 mm] 0.28" [7 mm] 0.185" [4.7 mm] 1.609.2"" (42.9[53mmmm]) 2.106" [53.5 mm] 0.28" [7 mm] DIMENSIONS GZ40AU Series 1.95 1.54 2.33 2.25" (57.15mm) .25 1.74 1.39 1.70 DIMENSIONS UWZ48 Series SCREW TO ATTACH TO MOUNTING PLATE 1.95 1.88" (47.75 mm) 1.54 2.25" (57.15mm) 1/4" SPADE TERMINALS .25 ADJUSTABLE RETAINING BRACKET REMOVED IN THIS VIEW 2.33 1.89" [48 mm] ADJUSTABLE 0.40" to 0.00" DIMENSIONS UWZ48V Series [501.m97m"] 1.89" ADJUSTA[4B8LEmm] 0.40" to 0.00" 1.74 1.39 .18" (4.57 mm) 2X .157" THRU (3.99 mm) THRU 1.531" (38.89 mm) 1.95 1.70 2X .1181".8(29."9972 mm) THRU .28" (.70.5161"m([14m.814).2m5Sm4'mFmA]C) DEPX. ADJUSTABLE RETAINING BRACKET .100 THRU 1.531" (38.89 mm) .42" (10.67 mm) 1/4" SPADE TERMINALS ADJUST1A.4B6L3E" (37.16 mm) [415.7m7m" ][3R11ER.2MEm2TOA(m"1VI6]N.E9I.ND26G6mIN6[m"B5T10R)H.A9mI7SCm"VK] IEETW .18" (4.57 mm) 0.126" [3.2 mm] 1.70 .21" (5.33 mm) 1.457" (37.01 mm) MOUNTIN1/G4"PSLPAATEDE TERMINALS DIMENSIONS ADJUSTABLUEWZ48E Series RETAINING BRACKET ADJUSTABLE RETAIN1I.N4G6"BRACKET REMO[V3E7DmINm]THIS VIEW 1.65" [42 mm] 1.7 [44.5 1.18" [30 mm] 2.36" [60 mm] [501.m97m"] 1.89" [48 mm] 1.93" [49 mm] 2.13" [54 mm] 1.77" [45 mm] 1.18" [30 mm] 2.36" [60 mm] 1.22" 1.77" [31 mm] [45 mm] [510.9m7m" ] 0.126" [3.2 mm] 1.3" [33 mm] 2.44" [62 mm] 1.77" [45 mm] 2.44" [62 mm] 1.34" [34 mm] 1.34" [34 mm] 1.93" 1.46" [37 mm] 1.65" [42 mm] 2.13" 105 Refrigeration Temperature Control Solutions From commercial kitchens to neighborhood convenience stores, properly managing the refrigeration needs of coolers, chillers and cooking equipment is essential to success. Our versatile refrigeration temperature controls offer a proven solution for refrigeration applications. Ice Refrigeration Machine Keep ice machines working at peak efficiency with our range of digital temperature controllers. These solutions can be placed conveniently in both new and retrofit refrigeration applications. Reach-In Refrigeration Cooler Boost energy efficiency in applications ranging from frozen novelty chests to convenience store wall coolers. Refrigeration Merchandiser Ensure refrigeration displays and merchandisers keep their cool with our easy-to-integrate time switches and temperature controls. Walk-In Refrigeration Cooler/Freezer Our robust defrost timers are the perfect fit for commercial walk-in cooler/freezer applications. Contents 24-Hour Electromechanical Defrost Timer ...............................108 24-Hour and/or 7-Day Electronic Defrost Timer ...................110 DTAV40 Wiring Diagrams/Enclosure and Bracket Dimensions ..111 Panel Mount Refrigeration Controllers ...................................112 Split Mount Refrigeration Controllers ....................................114 Controller Wiring Diagrams .....................................................116 Accessories .............................................................................117 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Refrigeration Temperature Controls Refrigeration Temperature Controls 24-Hour Mechanical Defrost Timer DTAV40 #E10694 Compliant 2002/95/EC Ratings Input Voltage Quartz Switch Type Resistive Motor Operating Temperature Operating Humidity Wiring Connections Enclosure/Mounting Min ON/OFF Times Max ON/OFF Times Electrical Life Warranty DTAV40 Inside 120/240 VAC, 60 Hz 120/240 VAC, 50/60 Hz 1 SPDT, 1 NC SPST 40 A, 120-240 VAC 1 HP, 16 FLA, 96 LRA @ 120 VAC, 2 HP, 12 FLA, 72 LRA @ 240 VAC -40°F - 104°F (-40°C - 40°C) 0-95% RH, Non-condensing Screw box lug terminals up to one #8 AWG wire Outdoor type 3R plastic, Bracket 15-min 23 hours, 45 min 50,000 operations at full load 1-Year limited DTAV40 Series 24-HOUR ELECTROMECHANICAL DEFROST TIMER For electric heat, hot gas or compressor shutdown defrost. The Intermatic DTAV40 Series Auto Voltage Defrost Timer is applicable to air defrost (compressor shutdown) and electric or hot gas defrost systems where the defrost cycle is terminated by the timer. If the coil is frost-free, the timer can also be terminated by temperature or pressure switches before the programmed defrost termination time has been reached. The time termination functions as a fail-safe and terminates the defrost cycle if the temperature or pressure switch fails to do so. Applications · Walk-in Refrigeration Cooler/Freezer Features · Adaptive Defrost upgradeable (DTAV40, DTAV40M only) (See ICUBETM) · DTAV40 Series replaces over 40 competitive models · 40 A, 2 HP Rating · Auto-voltage automatically adjusts between 120 and 240 VAC · Q model features self-recharging battery backup with 72-hour carry-over · Can mount in an existing enclosure no tools required for installation · Moisture resistant conformal-coated board · LED indicators for defrost and refrigeration cycles · Defrost cycles are programmed independently · "Real-time" clock face for quick, easy and accurate setting · Defrost times programmable in 15-minute intervals · Captive trippers won't get lost · Finger-safe box lug terminals Model # DTAV40 DTAV40Q DTAV40M Enclosure Outdoor type 3R plastic Outdoor type 3R plastic Mechanism Only Backup Protection Time None 72 Hours None ACCESSORIES Model Number Description DT-B Defrost Timer Bracket Note: Bracket dimensions on page 117 Give HVAC Maintenance Issues the Cold Shoulder An Ice Cold Original: DTAV40 Defrost Timer Simplify HVAC installations and reduce maintenance needs with the DTAV40 Defrost Timer, a 24-hour electromechanical control from Intermatic. The versatile defrost control mounts onto existing enclosures (no tools required) and serves as an easy replacement solution for more than 40 competing timers. It can be installed as a standalone solution or retrofit with the ICUBETM Adaptive Defrost Module to improve energy efficiency, all without replacing the existing enclosure. 108 Refrigeration Temperature Controls Refrigeration Temperature Controls 24-Hour Mechanical Defrost Timer ICUBETM ADAPTIVE DEFROST CONTROL MODULE Whether you're installing a total time clock replacement or looking for a fast retrofit, the Intermatic ICUBETM technology is an easy-to-integrate adaptive defrost solution for commercial and industrial refrigeration systems. When ICUBE technology is used with the Intermatic DTAV40 Defrost Timer it will reduce the overall defrost frequency within the cooler or freezer by up to 40% or more. The smart-sensing technology continuously monitors evaporator coil temperatures in walk-in coolers and freezers and only allows defrosting when necessary at the next programmed timer interval. Applications · Walk-in Refrigeration Cooler/Freezer Features · Stand-alone module assembles directly into existing Intermatic DTAV40 Defrost Timers (DTAV40 Only) · Energy-saving adaptive defrost only defrosts evaporator coils when necessary · LED indicator conveys status and fault conditions, including efficiency mode and probe fault · Maintains the timer's scheduling to reduce frequent defrost initiations during high usage times · Reaches remote condensing units up to 400 ft. with typical field-used 18 gauge shielded or unshielded wire · Four sensor inputs accommodate up to four evaporators or multiple sensor locations for larger coils · The stand-alone module (model# DDFM) simply installs underneath the existing DTAV40 FM-Timer Module · Sensing wire can be routed through existing conduit Model # DDFM DDT40 178GR10K-1 Description ICUBETM Adaptive Defrost Refrigeration Module with Sensor Complete Adaptive Defrost Refrigeration Time Control with ICUBETM Module, Sensor, and Type 3R Enclosure Additional Separate Sensor Accessory (for Multiple Evaporator Applications) Ratings- DDFM Thermistor* 10 K @ 25° C (77° F) Wire Size #24 AWG Working Range -40°F - 152°F (-40°C - 67°C) Thermistor Probe Type NTC Probe Wire Length 10 ft (3.05 m) Connector Wire Length 6 ft (1.83 m) Warranty 1-Year limited Thermistor probe connections are not an isolated Class 2 circuit. *Only use a thermistor probe specified for use with DDFM model. DDT40 DDFM #E10694 Compliant 2002/95/EC Ratings- DDT40 Input Voltage Auto Voltage 120-240 VAC, 60 Hz Switch Type 1 SPDT, 1 NC SPST Resistive 40 A, 120-240 VAC, 60 Hz Motor 1 HP, 16 FLA, 96 LRA @ 120 VAC, 2 HP, 12 FLA, 72 LRA @ 240 VAC Operating Temperature -40°F - 131°F (-40°C - 55°C) Operating Humidity 0-95% RH, Non-condensing Wiring Connections Finger safe terminals Enclosure/Mounting Outdoor type 3R plastic Min ON/OFF Times 15-min Max ON/OFF Times 23 hours, 45 min Warranty 1-Year limited SETTING DEFROST TIMES Configure defrost times easily! Just scan the QR code with your smartphone or tablet for details on how to choose a defrost starting time. 109 Refrigeration Temperature Controls Refrigeration Temperature Controls 24-Hour and/or 7-Day Electronic Defrost DTAV40E2 DTAV40E2 Series TIME INITIATED AND TEMPERATURE, PRESSURE OR TIME TERMINATED 40 A AUTO-VOLTAGE ELECTRONIC DEFROST TIMER The Intermatic DTAV40E2 Electronic Auto-voltage Defrost Timer has flexible 7-day scheduling and to-the-minute defrost duration control to increase system efficiency (decrease defrost scheduling during low demand periods). It is applicable to air defrost (compressor shutdown) and electric or hot gas defrost systems where the defrost cycle is terminated by the timer. If the coil is frost-free, the timer can also be terminated by temperature or pressure switches before the programmed defrost termination time has been reached. The time termination functions as a fail-safe and cancels the defrost cycle if the temperature or pressure switch fails to do so. APPLICATIONS · Walk-in Refrigeration Cooler/Freezer FEATURES · 24-Hour/7-Day flexible scheduling increases system efficiency · 40 A, 2 HP rating · DTAV40E2 replaces over 40 competitive models · Auto-voltage automatically adjusts between 120 and 240 VAC, 50/60 Hz · Self-recharging battery backup with 2500-hour carry-over · Can mount in an existing enclosure no tools required for installation · LED indicators for defrost and refrigeration cycles · Finger-safe box lug terminals · Simple to program electronic timer DTAV40E2 Inside #E10694 Ratings Input Voltage 120/240 VAC, 50/60 Hz Switch Type 1 SPDT, 1 NC SPST Resistive 40 A, 120-240 VAC Motor 1 HP, 16 FLA, 96 LRA @ 120 VAC, 2 HP, 12 FLA, 72 LRA @ 240 VAC Operating Temperature -13°F - 104°F (-25°C - 40°C) Operating Humidity 0-95% RH, Non-condensing Wiring Connections Screw box lug terminals up to one #8 AWG wire Enclosure/Mounting Outdoor type 3R plastic with bracket Min ON/OFF Times 1 min Max ON/OFF Times 23 hours, 59 min Electrical Life 50,000 operations at full load Warranty 1-Year limited Model # Enclosure DTAV40E2 Outdoor type 3R plastic For mounting & enclosure dimensions see next page. For wiring examples see next page. SET UP SYSTEM SCHEDULING Battery Backup 2500 Hours The electronic face and programming buttons make scheduling straightforward and easy. Just scan the QR code with your smartphone or tablet for details. 110 Refrigeration Temperature Controls Refrigeration Temperature Controls Wiring Diagrams / Enclosure and Bracket Dimensions DTAV40 WIRE DIAGRAMS Wiring diagrams in powered refrigeration mode. 8145 R eplacement (Retro t) DTAV40 Default Out of Box CONTROL TERMINATE POWER INPUT F L1 LINE L2 3 12 4 N DEFROST HEATER THERMOSTAT COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL FAN MOTOR X TERMINATION THERMOSTAT W/FAN DELAY TYPE 3R ENCLOSURE DIMENSIONS 6.61" [16.79 cm] 5.73" [14.55 cm] 8.88" [22.56 cm] 8041 Replacement (Retro t) CONTROL TERMINATE POWER INPUT N 13 L1 FAN LINE L2 DEFROST HEATER 24X THERMOSTAT COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL 8041 LABEL DT-B BRACKET DIMENSIONS 8045 Replacement (Retro t) CONTROL TERMINATE POWER INPUT F L1 LINE L2 3 1-N 2 4 X DEFROST HEATER THERMOSTAT COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL FAN MOTOR 8045 LABEL 3" [7.62 cm] 8141 R eplacement (Retro t) CONTROL TERMINATE POWER INPUT N L1 13 FAN LINE L2 DEFROST HEATER 24X THERMOSTAT COMPRESSOR OR SOLENOID VALVE OR CONTACTOR COIL 8141 LABEL TERMINATION THERMOSTAT W/FAN DELAY Equivalent in function, terminal identification, and wiring allows for quick and easy installation. Universal Replacement (See wiring diagrams for examples) Intermatic Paragon Precision 8141-00 8143-20 6141-00 6143-20 8143-00 8145-20 6143-00 6145-20 8145-00 8041-20 6145-00 6041-20 DTAV40 = 8041-00 8043-00 8045-20 6041-00 8047-20 6043-00 6045-20 6047-20 8045-00 8245-20 6045-00 6245-20 8047-00 8247-20 6047-00 6247-20 8141-20 6141-20 Equivalent in function, terminal identification, and wiring allows for quick and easy installation. 111 Refrigeration Temperature Controls Refrigeration Temperature Controls Panel Mount Refrigeration Controllers CD5-01WHRW-I UL60730-1 Compliant 2011/65/EU Ratings Input Voltage Resistive Load Ratings Compressor Defrost Fan AUX1 Relay Type Minimum Cycle Time Storage Temperature Real-time Clock Face Wire Size Panel Cut-Out H x W Dimensions H x W x D Operating Humidity Operating Temperature Electrical Life Warranty 100-240 VAC, 50/60 Hz 10 (2) A @ 240 VAC 15 (5) A @ 240 VAC 10 (2) A @ 240 VAC 1 A (30 A/1 mS) SPST 1 min 14°F - 122°F (-10°C - 50°C) No #10 AWG 1.14" x 2.80" (29 mm x 71 mm) 1.34" x 2.76" x 2.76" (34 mm x 70 mm x 70 mm) 0-80% RH, Non-condensing 14°F - 122°F (-10°C - 50°C) 100,000 operations at full load 5-Year limited CD5 UNIVERSAL PANEL MOUNT REFRIGERATION CONTROLLERS FOR LT & HT APPLICATIONS The CD5 Universal Panel Mount controller from LAE by Intermatic is a flexible solution for reach-in, self-contained refrigeration & freezer cases. The controller can be configured to be used on a wide variety of self-contained systems. The controller has been designed to function efficiently with today's advanced self-contained systems including those using R290, EC motors and LED lighting. APPLICATIONS · Ice Refrigeration Machine · Reach-In Refrigeration Cooler FEATURES · 3 Relays · 1 Solid State Relay (EC motor control) · 2-3 Sensors · NTC10K & PTC1000 selectable · 1-2 Digital inputs · Universal Voltage, 115 VAC - 240 VAC · R290 Compatible · IP55 Front Protection · -50° F to 248° F (-50° C to 120° C) Control range · RS485 Communications Standard Model # CD5-01WHRW-I Circuits Input Voltage 4 100-240 VAC, 50/60 Hz Enclosure Type Mounting IP55 Front Panel CD5 WIRING DIAGRAM DI1 T3/DI2 T2 T1 DOOR Reliable Solutions for Everyday Needs Digital Temperature Controllers and Custom Solutions From commercial kitchens to neighborhood convenience stores, properly managing refrigeration needs of coolers, chillers and cooking equipment is essential to success. LAE by Intermatic Digital Temperature Controllers offer a proven solution for essential refrigeration and cooking needs. Our versatile lineup of controllers integrates seamlessly in panel-mount and splitmount applications. Likewise, extensive customization options combined with our team's rich industry knowledge allow us to be a resource to manufacturers that are looking to bring their ideas to life. 112 Refrigeration Temperature Controls Panel Mount Refrigeration Controllers Refrigeration Temperature Controls AT1-5BS6E-ALI AT1-5 PANEL MOUNT REFRIGERATION CONTROLLERS FOR HT APPLICATIONS The AT1-5 Panel-Mount Controller family are compact and capable, providing excellent control options in a small package. The AT1-5 family of controllers feature 1-2 relays, one temperature sensor and a digital input. Ideal for medium temperature self-contained refrigeration systems. APPLICATIONS · Ice Refrigeration Machine · Reach-In Refrigeration Cooler FEATURES · 1-2 Relays · 1 Sensor · NTC10K & PTC1000 selectable · 1 Digital input · IP55 Front Protection · -50° F to 248° F (-50° C to 120° C) Control range · 14° F to 122° F (-10° C to 50° C) Ambient conditions · RS485 Communications Options Model # Circuits Input Voltage AT1-5BS6E-ALI 2 230 VAC ±10%, 50/60 Hz AT1-5BS6E-BGI 2 230 VAC ±10%, 50/60 Hz AT1-5AS5E-GI 1 230 VAC ±10%, 50/60 Hz AT1-5AS5U-BGI 1 115 VAC ±10%, 50/60 Hz AT1-5BS2E-BGI 2 230 VAC ±10%, 50/60 Hz AT1-5BS6U-BGI 2 115 VAC ±10%, 50/60 Hz For wire diagrams see page 116. Enclosure Type IP55 Front Mounting Panel UL60730-1 Compliant 2011/65/EU Ratings Input Voltage Resistive Load Ratings Compressor Fan See Model Table 16 (8) A @ 240 VAC 7 (2) A @ 240 VAC Relay Type Minimum Cycle Time Storage Temperature Real-time Clock Face Wire Size Panel Cut-Out H x W Dimensions H x W x D Operating Humidity Operating Temperature Electrical Life Warranty SPST 1 min 14°F - 122°F (-10°C - 50°C) No #10 AWG 1.14" x 2.80" (29 mm x 71 mm) 1.34" x 70" x 2.76" (34 mm x 70 mm x 70 mm) 0-80% RH, Non-condensing 14°F - 122°F (-10°C - 50°C) 100,000 operations at full load 5-Year limited AT2-5BS4E-ALI AT2-5 PANEL MOUNT REFRIGERATION CONTROLLERS FOR LT & HT APPLICATIONS The AT2-5 Panel-Mount Controller family are compact and capable, providing excellent control options in a small package. The AT2-5 family of controllers feature 3 relays, two temperature sensors and a digital input. Ideal for low or medium temperature self-contained refrigeration systems. APPLICATIONS · Ice Refrigeration Machine · Reach-In Refrigeration Cooler FEATURES · 3 Relays · 1-2 Sensors · NTC10K & PTC1000 selectable · 1 Digital input · IP55 Front Protection · -50° F to 248° F (-50° C to 120° C) Control range · 14° F to 122° F (-10° C to 50° C) Ambient conditions · RS485 Communications Options Model # Circuits Input Voltage AT2-5BS4E-ALI 3 230 VAC ±10%, 50/60 Hz AT2-5BS4E-GI 3 230 VAC ±10%, 50/60 Hz AT2-5BS4U-BGI 3 115 VAC ±10%, 50/60 Hz For wire diagrams see page 116. Enclosure Type IP55 Front Mounting Panel UL60730-1 Compliant 2011/65/EU Ratings Input Voltage Resistive Load Ratings Compressor Fan AUX1 Relay Type Minimum Cycle Time Storage Temperature Real-time Clock Face Wire Size Panel Cut-Out H x W Dimensions H x W x D Operating Humidity Operating Temperature Electrical Life Warranty See Model Table 16 (8) A @ 240 VAC 7 (2) A @ 240 VAC 7 (2) A @ 240 VAC SPST 1 min 14°F - 122°F (-10°C - 50°C) No #10 AWG 1.14" x 2.80" (29 mm x 71 mm) 1.34" x 2.76" x 2.76" (34 mm x 70 mm x 70 mm) 0-80% RH, Non-condensing 14°F - 122°F (-10°C - 50°C) 100,000 operations at full load 5-Year limited 113 Refrigeration Temperature Controls Split Mount Refrigeration Controllers Refrigeration Temperature Controls BIT25-B1S3U-BI BIT25 SPLIT MOUNT REFRIGERATION CONTROLLERS FOR LT & HT APPLICATIONS The BIT25 Split Controllers are designed to excel in more demanding applications and provide additional control options for more sophisticated equipment. The BIT25 controllers can be mounted to a wiring chase or with the refrigeration equipment, eliminating the need for long runs of control wiring. The BIT25 features 3 highly rated relays and universal power. APPLICATIONS · Ice Refrigeration Machine · Reach-In Refrigeration Cooler FEATURES · 3 Relays · 1-2 Sensors · NTC10K & PTC1000 selectable · 1 Digital input · IP55 Front Protection · 100-240 VAC, 50/60 Hz., or Universal Power Supply · -50° F to 248° F (-50° C to 120° C) Control range · 14° F to 122° F (-10° C to 50° C) Ambient conditions · RS485 Communications Options UL60730-1 Compliant 2011/65/EU Ratings Input Voltage Resistive Load Ratings Compressor AUX1 AUX2 Relay Type Minimum Cycle Time Storage Temperature Real-time Clock Face Wire Size Panel Cut-Out H x W Dimensions H x W x D Operating Humidity Operating Temperature Electrical Life Warranty See Model Table 12 (12) A @ 240 VAC 16 A @ 240 VAC 4 A @ 240 VAC SPST 1 min 14°F - 122°F (-10°C - 50°C) No #10 AWG 1.14" x 2.80" (29 mm x 71 mm) 1.57" x 3.27" x 2.76" (40 mm x 83 mm x 70 mm) 0-80% RH, Non-condensing 14°F - 122°F (-10°C - 50°C) 100,000 operations at full load 5-Year limited BIT25 WIRING DIAGRAM LCD-5S RS485 PC comm. A B remote data I/O 45 6 DI 2 DI 1 AUX 1 AUX 2 12(12)A 16A 4A 12 3 T2 T1 Max total current 16A L2/Neutral L1 Power Supply 10 11 12 13 14 16 87 mm 15 17 104 mm DI2 as input for T3 probe (DI2=T3) 45 DI2 DI2 as input for Setpoint potentionmeter adjustment (DI2=PSP) 34 2 5 1 6 45 DI2 70 mm 40 mm Model # BIT25-B1S3U-BI BIT25-B1S3W-BI BIT25-B1S3E-BI Circuits 3 3 3 Input Voltage 115 VAC ±10%, 50/60 Hz 110-240 VAC ±10%, 50/60 Hz 230 VAC ±10%, 50/60 Hz Enclosure Mounting IP55 Front DIN BIT25 DIMENSIONS 104 mm 70 mm 40 mm 87 mm 95 mm 83 mm 95 mm 114 Refrigeration Temperature Controls Split Mount Refrigeration Controllers Refrigeration Temperature Controls BR1-28C1Q5WH-B BR1-28 SPLIT MOUNT REFRIGERATION CONTROLLERS WITH RTC FOR LT & HT APPLICATIONS BD1-28C1S5W-BI BD1-28 SPLIT MOUNT REFRIGERATION CONTROLLERS FOR LT & HT APPLICATIONS The BR1-28 Split Controllers are designed to excel in more demanding applications and provide additional control options for more sophisticated equipment. The BR1-28 controllers can be mounted to a wiring chase or with the refrigeration equipment, eliminating the need for long runs of control wiring. The BR1-28 feature 3-5 highly rated relays and 2-3 sensors along with 2 digital inputs and RTC for exact timing of programmed events. APPLICATIONS · Ice Refrigeration Machine · Reach-In Refrigeration Cooler FEATURES · 3-5 Relays · 3 Sensors · NTC10K & PTC1000 selectable · 1 Digital input · IP55 Front Protection · 100-240 VAC, 50/60 Hz., or Universal Power Supply · R290 Rated Optional · -50° F to 248° F (-50° C to 120° C) Control range · 14° F to 122° F (-10° C to 50° C) Ambient conditions · RS485 Communications Options Model # Circuits Input Voltage BR1-28C1Q5WH-B 5 100-240 VAC ±10%, 50/60 Hz BR1-28C1S4WH-BI 4 100-240 VAC ±10%, 50/60 Hz BR1-28B0Q3W-AI 3 100-240 VAC ±10%, 50/60 Hz BR1-28C1Q5WH-BI 5 100-240 VAC ±10%, 50/60 Hz For wire diagrams see page 116. Enclosure Mounting IP55 Front DIN UL60730-1 Compliant 2011/65/EU Ratings Input Voltage Resistive Load Ratings Compressor Defrost Fan AUX1 Relay Type Minimum Cycle Time Storage Temperature Real-time Clock Face Wire Size Panel Cut-Out H x W Dimensions H x W x D Operating Humidity Operating Temperature Electrical Life Warranty See Model Table 16 (12) A @ 240 VAC 16 (4) A @ 240 VAC 16 (4) A @ 240 VAC 7 (2) A @ 240 VAC SPST 1 min 14°F - 122° F (-10°C - 50°C) Yes #10 AWG 1.14" x 2.80" (29 mm x 71 mm) 1.81" x 4.13" x 2.76" (46 mm x 105 mm x 70 mm) 0-80% RH, Non-condensing 14°F - 122°F (-10°C - 50°C) 100,000 operations at full load 5-Year limited The BD1-28 Split Controllers are designed to excel in more demanding applications and provide additional control options for more sophisticated equipment. The BD1-28 controllers can be mounted to a wiring chase or with the refrigeration equipment, eliminating the need for long runs of control wiring. The BD1-28 feature 3-5 highly rated relays and 2-3 sensors along with 2 digital inputs. APPLICATIONS · Ice Refrigeration Machine · Reach-In Refrigeration Cooler FEATURES · 5 Relays · 3 Sensors · NTC10K & PTC1000 selectable · 2 Digital inputs · IP55 Front Protection · 100-240 VAC, 50/60 Hz., or Universal Power Supply · -50° F to 248° F (-50° C to 120° C) Control range · 14° F to 122° F (-10° C to 50° C) Ambient conditions · RS485 Communications Options Model # Circuits Input Voltage BD1-28C1S5W-BI 5 100-240 VAC ±10%, 50/60 Hz For wire diagrams see page 116. Enclosure IP55 Front Mounting DIN UL60730-1 Compliant 2011/65/EU Ratings Input Voltage Resistive Load Ratings Compressor Defrost Fan AUX1 Relay Type Minimum Cycle Time Storage Temperature Real-time Clock Face Wire Size Panel Cut-Out H x W Dimensions H x W x D Operating Humidity Operating Temperature Electrical Life Warranty See Model Table 16 (8) A @ 240 VAC 16 (4) A @ 240 VAC 16 (4) A @ 240 VAC 7 (2) A @ 240 VAC SPST 1 min 14°F - 122°F (-10°C - 50°C) No #10 AWG 1.14" x 2.80" (29 mm x 71 mm) 1.81" x 4.13" x 2.76" (46 mm x 105 mm x 70 mm) 0-80% RH, Non-condensing 14°F - 122°F (-10°C - 50°C) 100,000 operations at full load 5-Year limited 115 Refrigeration Temperature Controls Wiring Diagrams Refrigeration Temperature Controls AT1-5 WIRING DIAGRAMS AT1-5BS4E-AG TTL door switch 78 door 9 11 10 T2 Com T1 AUX 16(5)A 7(2)A 16A 5 230Vac L1 L2 / Neutral 4 2 3 1 AT1-5AS5U-BG RS485 door switch 78 door 9 11 10 T2 Com T1 AUX 16(8)A 7(2)A 16A 120Vac L N 5 4 2 3 1 AT1-5BS6E-BG RS485 door switch 78 door 11 10 T1 AUX 16(8)A 7(2)A 16A 5 230Vac L1 L2 / Neutral 4 2 3 1 AT1-5BS6E-BG RS485 door switch 78 door 9 11 10 T2 Com T1 AUX 16(8)A 7(2)A 16A 5 230Vac L1 L2 / Neutral 4 2 3 1 116 AT2-5 WIRING DIAGRAM AT2-5BS4E-AG TTL Door Switch 78 9 11 10 T2 Com T1 AUX 16(5)A 7(2)A 7(2)A 3 230Vac L1 L2 / Neutral 4 512 BR1-28 WIRING DIAGRAM data I/O LIVE 12 4 5 6 7 8 9 10 11 FUSE 20A L1 L2 / Neutral 13 19 Power Supply 100...240 Vac RS485 Aux AUX 2 AUX 1 7A 7A 16(4)A 16(4)A 20 21 22 23 24 25 26 27 28 AIR T1 EVP T2 AUX T3 DI 1 DI 2 DI 3 AC L2 / Neutral 16(12)A DC remote Remote unit BD1-28 WIRING DIAGRAM data I/O LIVE 12 4 56 7 8 9 10 11 '64&" - -/FVUSBM Power Supply 100...240 Vac 13 19 RS485 AUX 2 AUX 1 7A 7A 16(4)A 16(4)A 16(12)A AC NEUTRAL DC 20 21 22 23 24 25 26 27 28 Aux AIR T1 EVP T2 AUX T3 DI1 DI2 DI3 remote Remote unit Refrigeration Temperature Controls Refrigeration Temperature Controls Accessories Model Number SN4B50P1 SN4B30P1 SN4B20P1 SN4B20P2-B SN4B20P3-Y SN4B30P2-B SN4B30P3-Y SN4B50P2-B SN4B50P3-Y LCD-5S-1I DU5S-1I Description Temperature Probe, NTC 10k probe, 5.0 m, Gray Temperature Probe, NTC 10k probe, 3.0 m, Gray Temperature Probe, NTC 10k probe, 2.0 m, Gray Temperature Probe, NTC 10k probe, 2.0 m, Blue Temperature Probe, NTC 10k probe, 2.0 m, Yellow Temperature Probe, NTC 10k probe, 3.0 m, Blue Temperature Probe, NTC 10k probe, 3.0 m, Yellow Temperature Probe, NTC 10k probe, 5.0 m, Blue Temperature Probe, NTC 10k probe, 5.0 m, Yellow Display, BIT25 Display, BD1-28, BR1-28 ACCESSORIES SN4B50P1 Display, BIT25 SN4B20P2-B DU5S-1I SN4B20P3-Y DID YOU KNOW? DTAV40 Series Commercial Refrigeration Defrost Timers are applicable to air defrost (compressor shutdown) and electric or hot gas defrost systems where the defrost cycle is terminated by a timer or a temperature or pressure switch. The time termination functions as a failsafe and terminates the defrost cycle if the temperature or pressure switch fails to do so. Self-service kiosks present their own unique challenges from refrigerated reach-in coolers to chest freezer merchandisers to heated food warming displays. LAE by Intermatic Digital Controllers offer a proven solution for temperature control and can be used to modulate temperatures in a wide range of applications. 117 Surge Protection Solutions Safeguard home appliances and commercial and Industrial equipment from damaging power surge events with our rugged surge protection solutions. These versatile SPDs provide a variety of protection options and offer lasting peace of mind. Distribution Panelboards and Subpanels Connect our surge protection solutions to residential or commercial distribution panelboards or subpanels for a layer of coverage against power surge events. This method of installation can be completed in minutes and offers a lasting defense against power quality issues. Service Entrance Keep power surge events at bay by placing one of our Type I SPDs at the service entrance. This provides widespread protection against harmful power quality issues. Point-of-Use Protection Our basic point-of-use surge protection solutions install in minutes and help safeguard electronics and appliances from unexpected power surge issues in simple, ad-hoc applications. Whole Home Protection Get wall-to-wall protection from harmful surge events by installing a whole home surge protective device in residential applications. Contents Surge Protection Education ...................................................120 Type 1 or 2 SPD for Industrial/Commercial ..........................124 Light Commercial or Outdoor Surge Protection ....................128 Type 1 or 2 SPD for Residential and Light Commercial ...........129 Type 3 SPD for Commercial and Industrial .............................132 Type 2 SPD - Includes Telephone and Coax Line Protection ...........133 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Surge Protection Surge Protection Surge Protection Education Causes of Power Disturbances Electrical disturbances and downtime cost North American companies and residents more than $26 billion every year. Fluctuations in utility power (caused by grid switching, for example) are often suspected to be the main culprits. However, the overwhelming cause of power disturbances is actually from transient voltage surges from equipment inside a facility. In fact, it is estimated that 65% of all transient voltage surges are generated from inside sources, while only 35% come from outside.* Triggers of transient surges can range from the stopping and starting of motors, appliances and electronics, to even the simple action of switching lights ON and OFF. * NEMA Surge Protection Institute What Requires Surge Protection? Every process and appliance within a building is controlled by electrical equipment and electronic components. Virtually all devices that are powered by electricity are vulnerable. The following types of systems will benefit from surge protection: · Home Theater Systems · Computers/Peripherals/Servers · HVAC/R Systems and Controls · Electronically Commutated Motors · Pool and Spa Systems and Controls · Smartphones/Tablets/Gaming Systems · Charging Equipment for Hybrid and Electric Cars · Variable Frequency Drives · Security and Fire Alarm Systems · Programmable Logic Controllers · Network Servers/Routers/Modems · Lighting Ballasts · Uninterruptible Power Supplies · Home Automation Controls · Pumps, Motors and Related Equipment with Electronic Controls or Starters · Telecom Equipment · Generator Automatic Transfer Switches (ATS) 120 Surge Protection Surge Protection Surge Protection Education ANSI/UL 1449, 3rd Edition, Surge Protection Compliance UL 1449, 2nd Edition, underwent a major revision requiring additional safety testing at medium-fault current levels for Transient Voltage Surge Suppressors (TVSS). UL 1449, 3rd Edition, was published in September 2006 with compliance required by September 2009. The major differences are: · UL 1449, 3rd Edition, is now an American National Standard (ANSI) · Change in terminology from Transient Voltage Surge Suppressors to Surge Protective Devices (SPD) · Voltage Protection Rating (VPR) is now tested at 6 kV/3 kA. · Nominal Discharge Current (In) is a new addition. Terminology Change The full title of UL 1449, 2nd Edition, is, "Standard for Safety for Transient Voltage Surge Suppressors, UL 1449". The new title of UL 1449, 3rd Edition, is, "Standard for Safety for Surge Protective Devices, UL 1449." "Surge Protective Devices" is a more general description and covers devices beyond what we formerly called TVSS. The term SPD also covers what are referred to as Secondary Surge Arrestors. UL 1449, 3rd Edition, gives five designations to surge protective devices depending on where in the electrical system the device is connected. Below defines Types 1-3. Type 1 -- Permanently connected device installed before or after the service disconnect overcurrent device and intended to be installed with no external overcurrent protective device. This type of SPD most closely relates to devices that were called secondary surge arrestors prior to 3rd Edition. Type 2 -- Permanently connected device installed after the service disconnect overcurrent device. This type of SPD most closely relates to devices that were called transient voltage surge suppressors prior to 3rd Edition. Type 3 -- Point of use SPDs that are installed with a minimum of 30 feet of conductor length from the service panel. These 30 feet of conductor length does not include conductors used to attach the SPD. Some examples of Type 3 SPDs are cord connected, direct plug-in and receptacle type SPDs. Industrial Residential Meter Service Entrance Meter Service Entrance Type 1 Before Panel Type 2 After Panel Type 3 Direct Plug-in Type 1 Before Panel Type 2 After Panel Type 3 Direct Plug-in Voltage Protection Rating (VPR) The measured limiting voltage test in UL 1449, 3rd Edition, uses a 6 kV/3 kA combination wave surge to determine the Voltage Protection Rating (VPR) of the SPD. This test is similar to the Suppressed Voltage Rating (SVR) as performed in UL 1449, 2nd Edition. The key difference between the tests in 2nd Edition and 3rd Edition is that the magnitude of the current used for the test is six times greater in 3rd Edition versus 2nd Edition. This much higher current level will mean that the Voltage Protection Rating (VPR) will likely be significantly higher. Nominal Discharge Current (In) The addition of the nominal discharge current test is new to UL 1449 3rd Edition. The nominal discharge current value is selected by the manufacturer and can be either 10 kA or 20 kA for a Type 1 SPD or 3 kA, 5 kA, 10 kA or 20 kA for Type 2 SPDs. The SPD is tested by being subjected to a total of 15 impulses of the manufacturer-selected nominal discharge current. 121 Surge Protection Surge Protection Surge Protection Education Joule Ratings Many end users look at Joule ratings to determine which surge protector to purchase. Unfortunately, Joule ratings can be misleading according to IEEE research. When a surge protector is submitted for third party agency testing, Joule rating is not a tested parameter. Joule ratings are an unreliable measurement for determining a product's surge protection capacity because there is no clear standard for energy ratings of SPDs on Joules. Typical Surge Protective Device (SPD) Residential Applications Entertainment Home Theaters, TV, Stereos Home Office, Computers, Tablets, Printers 74 74 HVAC, Generators, Solar 74 74 Mini-split, Furnace/ Air Handler, Boilers 74 Home Automation, Thermostats, Security, Lighting Pool & Spa Equipment, Water Heater, Landscape Lighting 122 Surge Protection Surge Protection Surge Protection Education Common Voltage Configurations The wiring diagrams below illustrate the common voltage configurations for Intermatic surge products. 120 VAC Single Phase 120, 240 VAC Single Phase (Split Phase) 120, 208 VAC Three Phase Wye 120, 240 VAC Three Phase HLD (High Leg Delta) 277, 480 VAC Three Phase Wye 347, 600 VAC Three Phase Wye 277, 480 VAC Single Phase Note: All SPDs protect against surges that travel along the electrical pathway and are not applicable to direct lightning strikes that travel down non-electrical paths. Be sure to have at least a 20 A dual pole breaker(s) to help prevent the circuits from shorting. Type 1 SPDs are normally mounted before panels, which would not include a breaker. Surge Glossary Maximum Continuous Operating Voltage (MCOV): The maximum RMS voltage that may be applied to each mode of a surge protection device. (Listed on the product) Modes Of Protection: Electrical paths within a system which an SPD offers defense against surge events. Examples of protection include, Line to Neutral (L-N), Line to Ground (L-G), Line to Line (L-L) and Neutral to Ground (N-G). (Listed on the product) Nominal Discharge Current (In): Peak value of the current through the SPD having a current wave shape of 8/20 where the SPD remains functional after 15 surges. (Listed on the product) Nominal System Voltage: The voltage level at which a system normally operates. Nominal system voltages include, but are not limited to, 120, 208, 240, 277, 347, 480, 600 VAC. (Listed on the product) Short Circuit Current Rating (SCCR): The measurement of how much current the electrical system can supply during a fault condition. This value determines where an SPD may be installed. (Listed on the product) Surge: A sudden and sharp increase of current or voltage within electric circuits. Surge Protective Device (SPD): A device used to limit a surge on equipment by diverting or limiting it. SPDs were previously known as Transient Voltage Surge Suppressors or secondary surge arresters. Voltage Protection Rating (VPR): The value assigned by UL which specifies the measured limited voltage value of the SPD. VPR rating is formally known as the "suppressed voltage rating". (Listed on the product) 123 Surge Protection Type 1 or 2 SPD for Industrial/Commercial Surge Protection PANELGUARD® L5 Series TYPE 1 OR 2 SPD L5 Series Intermatic PANELGUARD® Surge Protective Devices are designed to react quickly and eliminate surges providing optimal protection to downstream equipment. PANELGUARD® Industrial/Commercial-grade series are Parallel Connected Surge Protective Devices designed to protect all types of loads fed from individual disconnects, sub-panels, distribution panels and service entrance locations. Applications · Distribution Panel · Service Entrance · Subpanels · Utility Meters Features · Type 1 and Type 2 surge protection options · Optional audible alarm and dry contact relay · 4 Modes of protection · UL 96A Lightning system protection compliant · NEMA 4X enclosure for indoor or outdoor installation · Individually integrated disconnect TPMOV® surge protection technology · Optional advanced electrical noise filter (UL 1283) (Type 2 only) · Blue LED protection status indicator, and red LED service indicator Model # SPD Voltage Type Audible Alarm, Filter Dry Relay Contact Maximum Continuous Operating Voltage (L-N) (L-L) (L-G) (N-G) L5F21S1DG1 2 L5F21S1DG2 2 120/240 VAC Single-Phase Yes EMI/RFI Filter 150 300 150 150 EMI/RFI Filter 150 300 150 150 L5F13D1DG1 1 L5F13D1DG2 1 120/240 VAC 3-Phase High Leg Delta Yes No Filter No Filter 150/300* 300/300* 150/300* 150 150/300* 300/300* 150/300* 150 L5F13Y1DG1 1 No Filter 150 300 150 150 L5F13Y1DG2 1 L5F23Y1DG1 2 120/208 VAC 3-Phase Wye Yes No Filter 150 300 150 150 EMI/RFI Filter 150 300 150 150 L5F23Y1DG2 2 Yes EMI/RFI Filter 150 300 150 150 L5F13Y2DG1 1 No Filter 320 640 320 320 L5F13Y2DG2 1 L5F23Y2DG1 2 277/480 VAC 3-Phase Wye Yes No Filter 320 640 320 320 EMI/RFI Filter 320 640 320 320 L5F23Y2DG2 2 Yes EMI/RFI Filter 320 640 320 320 L5F13Y3DG1 1 L5F13Y3DG2 1 347/600 VAC 3-Phase Wye Yes No Filter No Filter 420 800 420 420 420 800 420 420 * Rating reflects Phase High Leg Voltage Protection Rating (L-N) (L-L) (L-G) 700 1200 1200 700 1200 1200 700/1200* 1200/2500* 1200/1800* 700/1200* 1200/2500* 1200/1800* 600 1200 1200 600 1200 1200 700 1200 1200 700 1200 1200 1200 2500 2500 1200 2500 2500 1200 2500 2500 1200 2500 2500 1500 3000 3000 1500 3000 3000 (N-G) 600 600 600 600 600 600 600 600 1200 1200 1200 1200 1500 1500 Modes of Protection 4 L5 SERIES DIMENSIONS 1.05" 6.36" 4.72" 3.15" 3.54" 4.81" 0.20" THRU 5.36" Ratings Voltage See Model Table MCOV* See Model Table Voltage Protection Rating See Model Table Max Surge Current Rating 50 kA Per Phase Nominal Discharge Current 20 kA Short Circuit Current Rating 200 kA Diagnostics Indicator Blue LED Protection Status Indicator, Red LED Service Indicator Wire Size #10 AWG Enclosure Type NEMA Type 4X Dimensions H x W x D 6.46" x 4.81" x 3.54" (164.084 mm x 122.17 mm x 89.92 mm) Operating Temperature -40°F - 176°F (-40°C - 80°C) Warranty 5-Year limited * Maximum Continuous Operating Voltage 124 Surge Protection Type 1 or 2 SPD for Industrial/Commercial Surge Protection PANELGUARD® L10 Series TYPE 1 OR 2 SPD Intermatic PANELGUARD® Surge Protective Devices are designed to react quickly and eliminate surges providing optimal protection to downstream equipment. PANELGUARD® Industrial/Commercial-grade series are Parallel Connected Surge Protective Devices designed to protect all types of loads fed from individual disconnects, sub-panels, distribution panels and service entrance locations. Applications · Distribution Panel · Service Entrance · Subpanels · Utility Meters Features · Type 1 and Type 2 surge protection options · Optional audible alarm and dry contact relay · 4 Modes of protection · UL 96A Lightning system protection compliant · NEMA 4X enclosure for indoor or outdoor installation · Individually integrated disconnect TPMOV® surge protection technology · Optional advanced electrical noise filter (UL 1283) (Type 2 only) · Blue LED protection status indicator, and red LED service indicator L10 Series Model # SPD Voltage Type Audible Alarm, Filter Dry Relay Contact Max Continuous Operating Voltage (L-N) (L-L) (L-G) (N-G) Voltage Protection Rating (L-N) (L-L) (L-G) (N-G) L10F11S1DG1 1 L10F11S1DG2 1 120/240 VAC Single-Phase Yes No Filter No Filter 150 300 150 150 700 1000 1000 700 150 300 150 150 700 1000 1000 700 L10F23D1DG1 2 L10F23D1DG2 2 120/240 VAC 3-Phase High Leg Delta Yes EMI/RFI Filter 150/300* 300/300* 150/300* 150 600/1200* 200/2000* 1200/2000* 700 EMI/RFI Filter 150/300* 300/300* 150/300* 150 600/1200* 200/2000* 1200/2000* 700 L10F13N4DG1 1 No Filter 552 552 4000 1800 L10F13N4DG2 1 L10F23N4DG1 2 440/480 VAC Yes 3-Phase High Leg Delta No Filter 552 552 4000 1800 EMI/RFI Filter 552 1800 4000 1800 L10F23N4DG2 2 Yes EMI/RFI Filter 552 1800 4000 1800 L10F13Y1DG1 1 No Filter 150 300 150 150 700 1000 1000 700 L10F13Y1DG2 1 L10F23Y1DG1 2 120/208 VAC 3-Phase Wye Yes No Filter 150 300 150 150 700 1000 1000 700 EMI/RFI Filter 150 300 150 150 700 1200 1200 700 L10F23Y1DG2 2 Yes EMI/RFI Filter 150 300 150 150 700 1200 1200 700 L10F13Y2DG1 1 No Filter 320 640 320 320 1200 2000 2000 1200 L10F13Y2DG2 1 L10F23Y2DG1 2 277/480 VAC 3-Phase Wye Yes No Filter 320 640 320 320 1200 2000 EMI/RFI Filter 320 640 320 320 1200 2500 2000 1200 2500 1200 L10F23Y2DG2 2 Yes EMI/RFI Filter 320 640 320 320 1200 2500 2500 1200 L10F13Y3DG1 1 L10F13Y3DG2 1 347/600 VAC 3-Phase Wye Yes No Filter No Filter 420 800 420 420 1500 3000 420 800 420 420 1500 3000 3000 1500 3000 1500 * Rating reflects Phase High Leg Ratings L10 SERIES DIMENSIONS 1.02" Voltage See Model Table MCOV* See Model Table Voltage Protection Rating See Model Table Max Surge Current Rating 100 kA Per Phase Nominal Discharge Current 20 kA Short Circuit Current Rating 200 kA Diagnostics Indicator Blue LED Protection Status Indicator, Red LED Service Indicator 10.47" 8.74" Wire Size #10 AWG Enclosure Type NEMA Type 4X Dimensions H x W x D 10.59" x 5.25" x 3.29" (268.99 mm x 133.35 mm x 83.57 mm) Operating Temperature -40°F - 176° F (-40° C - 80°C) Warranty 5-Year limited * Maximum Continuous Operating Voltage 3.87" 3.30" 5.23" Modes of Protection 4 0.20" THRU 9.24" 125 Surge Protection Type 1 or 2 SPD for Industrial/Commercial Surge Protection PANELGUARD® H10 Series TYPE 1 OR 2 SPD H10 Series Intermatic PANELGUARD® Surge Protective Devices are designed to react quickly and eliminate surges providing optimal protection to downstream equipment. PANELGUARD® Industrial/Commercial-grade series are Parallel Connected Surge Protective Devices designed to protect all types of loads fed from individual disconnects, sub-panels, distribution panels and service entrance locations. Applications · Distribution Panel · Service Entrance · Subpanels · Utility Meters Features · Type 1 and Type 2 surge protection options · Optional audible alarm and dry contact relay · 7 Modes of protection · NFPA 780, UL 96A Lightning system protection compliant · NEMA 4X enclosure for indoor or outdoor installation · Individually integrated disconnect TPMOV® surge protection technology · Optional advanced electrical noise filter (UL 1283) (Type 2 only) · Blue LED status indicator per phase, red LED service indicator Model # SPD Voltage Type Audible Alarm, Filter Dry Relay Contact Maximum Continuous Operating Voltage (L-N) (L-L) (L-G) (N-G) H10S21S1DG1 2 H10S21S1DG2 2 120/240 VAC Single-Phase Yes EMI/RFI Filter 150 300 150 150 EMI/RFI Filter 150 300 150 150 H10S13D1DG1 1 H10S13D1DG2 1 H10S23D1DG1 2 H10S23D1DG2 2 120/240 VAC Yes 3-Phase High Leg Delta Yes No Filter 150/300* 300/300* 150/300* 150 No Filter 150/300* 300/300* 150/300* 150 EMI/RFI Filter 150/300* 300/300* 150/300* 150 EMI/RFI Filter 150/300* 300/300* 150/300* 150 H10S13Y1DG1 1 No Filter 150 300 150 150 H10S13Y1DG2 1 H10S23Y1DG1 2 120/208 VAC Yes 3-Phase Wye No Filter 150 EMI/RFI Filter 150 300 150 150 300 150 150 H10S23Y1DG2 2 Yes EMI/RFI Filter 150 300 150 150 H10S13Y2DG1 1 No Filter 320 640 320 320 H10S13Y2DG2 1 H10S23Y2DG1 2 277/480 VAC Yes 3-Phase Wye No Filter 320 640 320 320 EMI/RFI Filter 320 640 320 320 H10S23Y2DG2 2 Yes EMI/RFI Filter 320 640 320 320 H10S13Y3DG1 1 H10S13Y3DG2 1 347/600 VAC 3-Phase Wye Yes No Filter No Filter 400 800 400 400 400 800 400 400 * Rating reflects Phase High Leg H10S13Y2DG1 & H10S13Y2DG2 not NFPA compliant Voltage Protection Rating (L-N) (L-L) (L-G) 700 1200 700 700 1200 700 700/1200* 1000/1800* 700/1200* 700/1200* 1000/1800* 700/1200* 700/1200* 1200/1800* 700/1200* 700/1200* 1200/1800* 700/1200* 600 1000 600 600 1000 600 700 1000 600 700 1000 600 1200 2000 1200 1200 2000 1200 1200 2500 1200 1200 2500 1200 1500 2500 1500 1500 2500 1500 (N-G) 700 700 700 700 700 700 700 700 700 700 1200 1200 1200 1200 1500 1500 Modes of Protection 7 H10 SERIES DIMENSIONS 1.02" 10.47" 8.74" 3.30" Ratings 0.20" THRU Voltage MCOV* See Model Table See Model Table Voltage Protection Rating See Model Table Max Surge Current Rating 100 kA Per Phase Nominal Discharge Current 20 kA Short Circuit Current Rating 200 kA 9.24" Diagnostics Indicator Blue LED Status Indicator Per Phase, Red LED Service Indicator Wire Size #10 AWG Enclosure Type NEMA Type 4X Dimensions H x W x D 10.59" x 5.25" x 3.29" (268.99 mm x 133.35 mm x 83.57 mm) Operating Temperature -40°F - 176°F ( -40°C - 80°C) Warranty 10-Year limited 3.87" 5.23" * Maximum Continuous Operating Voltage 126 Surge Protection Type 1 or 2 SPD for Industrial/Commercial Surge Protection PANELGUARD® H20 Series TYPE 1 OR 2 SPD Intermatic PANELGUARD® Surge Protective Devices are designed to react quickly and eliminate surges providing optimal protection to downstream equipment. PANELGUARD® Industrial/Commercial-grade series are Parallel Connected Surge Protective Devices designed to protect all types of loads fed from individual disconnects, sub-panels, distribution panels and service entrance locations. Applications · Distribution Panel · Service Entrance · Subpanels · Utility Meters Features · Type 1 and Type 2 surge protection options · Optional audible alarm and dry contact relay · 7 Modes of protection · NFPA 780, UL 96A Lightning system protection compliant · NEMA 4X enclosure for indoor or outdoor installation · Individually integrated disconnect TPMOV® surge protection technology · Optional advanced electrical noise filter (UL 1283) (Type 2 only) · Blue LED status indicator per phase, red LED service indicator H20 Series Model # SPD Voltage Type Audible Alarm, Filter Dry Relay Contact Maximum Continuous Operating Voltage (L-N) (L-L) (L-G) (N-G) H20S21S1DG1 2 H20S21S1DG2 2 120/240 VAC Single-Phase Yes EMI/RFI Filter 150 300 150 150 EMI/RFI Filter 150 300 150 150 H20S13D1DG1 1 H20S13D1DG2 1 H20S23D1DG1 2 H20S23D1DG2 2 120/240 VAC Yes 3-Phase High Leg Delta Yes No Filter 150/300* 300/300* 150/300* 150 No Filter 150/300* 300/300* 150/300* 150 EMI/RFI Filter 150/300* 300/300* 150/300* 150 EMI/RFI Filter 150/300* 300/300* 150/300* 150 H20S13Y1DG1 1 No Filter 150 300 150 150 H20S13Y1DG2 1 H20S23Y1DG1 2 120/208 VAC Yes 3-Phase Wye No Filter 150 300 150 150 EMI/RFI Filter 150 300 150 150 H20S23Y1DG2 2 Yes EMI/RFI Filter 150 300 150 150 H20S13Y2DG1 1 No Filter 320 640 320 320 H20S13Y2DG2 1 H20S23Y2DG1 2 277/480 VAC Yes 3-Phase Wye No Filter 320 640 320 320 EMI/RFI Filter 320 640 320 320 H20S23Y2DG2 2 Yes EMI/RFI Filter 320 640 320 320 H20S13Y3DG1 1 H20S13Y3DG2 1 347/600 VAC 3-Phase Wye Yes No Filter No Filter 400 800 400 400 400 800 400 400 * Rating reflects Phase High Leg H20S13Y2DG1 & H20S13Y2DG2 not NFPA compliant Voltage Protection Rating (L-N) (L-L) (L-G) 700 1200 700 700 1200 700 700/1200* 1200/2000* 700/1200* 700/1200* 1200/2000* 700/1200* 800/1200* 1200/2000* 700/1200* 800/1200* 1200/2000* 700/1200* 700 1000 700 700 1000 700 700 1200 700 700 1200 700 1200 2000 1200 1200 2000 1200 1200 2500 1200 1200 2500 1200 1500 3000 1500 1500 3000 1500 (N-G) 700 700 700 700 700 700 700 700 700 700 1200 1200 1200 1200 1500 1500 Modes of Protection 7 Ratings Voltage See Model Table MCOV* See Model Table Voltage Protection Rating See Model Table Max Surge Current Rating 200 kA Per Phase Nominal Discharge Current 20 kA Short Circuit Current Rating 200 kA Diagnostics Indicator Blue LED Status Indicator Per Phase, Red LED Service Indicator Wire Size #10 AWG Enclosure Type NEMA Type 4X Dimensions H x W x D 10.59" x 5.25" x 3.29" (268.99 mm x 133.35 mm x 83.57 mm) Operating Temperature -40°F - 176°F (-40 °C - 80°C) Warranty 10-Year limited * Maximum Continuous Operating Voltage H20 SERIES DIMENSIONS 1.02" 10.47" 8.74" 3.30" 0.20" THRU 9.24" 3.87" 5.23" 127 Surge Protection Light Commercial or Outdoor Surge Protection Surge Protection AG48013 AG Series TYPE 1 OR 2 SPD The AG Series Surge Protective Devices (SPD) are designed for a variety of applications. Trusted, state-of-the-art TPMOV® (Thermally Protected Metal Oxide Varistor) surge protection technology eliminates the potentially hazardous failure modes that are commonly associated with standard MOV technology. A green LED indicator provides status of protection. Type 1 applications include outdoor installations before service entrances and utility meter cabinets. Type 2 applications include installations after service entrances. Applications · Distribution Panel · Service Entrance · Subpanels and Load Centers Features · Three or six modes of protection · TPMOV® surge protection technology · Green LED protection indicator · Type 4X watertight, plastic enclosure for outdoor installations · UV-resistant polycarbonate housing · 1/2" threaded nipple for 7/8" normal conduit knockout · 1-year product warranty Model # Input Voltage Modes of Maximum Continuous Operating Voltage Protection (L1-L2) (L-N) (L-L) (L-G) Voltage Protection Rating (L-N) (L-L) (L-G) Lead Lead Length Gauge Single Phase Models AG2401C3 120/240 VAC Single-Phase 300 150 300 150 700 1200 700 18" #12 AWG 3 (L1-N, AG48013 277/480 VAC Single-Phase L2-N, 18" #6 AWG (Green) L1-L2) 640 320 640 320 1200 2000 1200 #10 AWG (Black, White) Three Phase Models AG2083C3 AG4803C3 AG6503C3 AG6503L3 AG2403C3 120/208 VAC 3-Phase Wye 277/480 VAC 3-Phase Wye 347/600 VAC 3-Phase Wye 347/600 VAC 3-Phase Wye 120/240 VAC 3-Phase High Leg Delta 6 (L1-N, L2-N, L3-N, L1-L2, L1-L3, L2-L3) 300 150 300 150 700 1200 700 18" 640 320 640 320 1200 2000 1200 18" 840 420 840 420 1500 2500 1500 18" 840 420 840 420 1500 2500 1500 36" (L1-L3) (L1-N/G) (L2-L3) (L2-N/G) (L3-N/G) (L1-L2) (L1-L3) (L1-N/G) (L2-L3) (L2-N/G) (L3-N/G) 18" 420 300 150 420 270 150 1500 1200 700 1500 1000 700 #12 AWG #12 AWG #10 AWG #10 AWG #12 AWG CSA and UL Recognized ACCESSORIES Model Number AG1BRKT Description Mounting Bracket for AG2401C3, AG48013, AG2083C3, AG4803C3, AG6503C3, AG6503L3, AG2403C3 TYPE 1 TYPE 2 AG1BRKT Line Line NeuRtraatlings 1N2e0uvtral 120 v GroSuPnDd G0rvound Type 120 v 120 v 0 v WHITE 1sFpaB2einolea0pduccanekVsrdsiAanwaotgCiertfleecTegsowqprncouhooniau1sFpaBpISSnews2einnnolmeanceCu0pdudictcere(rCian.meeokVskcgnrdRsintAtoAansewstaosttgiCo)(ionePrtuf*lfkeerogLccTersgAsroihlowqp.nre)incouhNtneao*eonpiaud.Os*pnecwhsinmvTpncetadiiitueEdresio.meomcun:enntatoBspwstlstiToosonuifetrtogLhcshcrihl.nehiNneanpd.OsohivTplaiouEdsgmu:eayBpwlositthh Max Surge Current Per Phase BLACK BLACK 1 WorHIT2E 20 kA 50 kA TPMOV® 50 kA BLACK BLACK Operating Temperature -31°F - 185°F (-35°C - 85°C) Dimensions H x Dia 4 3/16" x 3" (106.4 mm x 76.2 mm) Warranty 1-Year limited WIRING DIAGRAMS FOR AG2401C3 * Nominal Discharge Current ** Short Circuit Current Rating Line Neutral Ground 120 v 120 v 0 v 120 VAC Two wire single phase with separate ground. Found at connections for individual pieces of equipment such as pumps and single phase motors. NOTE: Both Black wires connect to Line. WHITE BLACK BLACK Line Grounded/ Neutral Line Line Gr1o2u0nvded/ Neutral 240 v Lin12e0 v 1B2L0ACvK 240 v 1W2H0ITvE BLACK BLACK WHITE BLACK 1nFa2neo0duu/nt2Mrda4el0a.tetVrSACeCrav1nFanTic2nseohe.0duur/nete2Mrdena4etl0awr.taetVinrrSAecCeeCwrasvnTiitcshhe.rgeerenotwruaninrdeceewdsith grounded Line Neutral Line Ground Line Neut1r2a0l v 240 v Line120 v 120 v 240 v 12W0HvITE Grou1n20d v 120 v BLACK WHITE BLACK 1FMS2oua0ubin/n2pdD4a0iinnsetVrMlAisbaCuaintn1FMSiTod2Douhan0uebirisn/pnqe2cpadueD4oani0npiwinnesnmetVlisrMerleAise,bcanLCtuawitonStnilTiaoodwtDhhdncieitarscCspqetchieaueeooepninnnpwseatsnm,elir.serraee,sctnLetwtoSgliaowtrhdcoitaucCsthieneoepdnnsa.ts,er.raste ground. BLACK BLACK 128 Surge Protection Type 1 or 2 SPD for Residential and Light Commercial Surge Protection IG3240RC3 IG Series, SPD TYPE 1 OR TYPE 2 SPD The IG Series Surge Protective Devices (SPD) are designed for a variety of applications. A green LED indicator provides status of protection. Trusted, state-of-the-art TPMOV® (Thermally Protected Metal Oxide Varistor) surge protection technology eliminates the potentially hazardous failure modes that are commonly associated with standard MOV technology. Type 1 applications include outdoor installations before service entrances and utility meter cabinets. Type 2 applications include installations after service entrances. CSA certified to ANSI/UL 1449, 3rd Edition. APPLICATIONS · Whole Home Protection FEATURES · Three or six modes of surge protection depending on model · TPMOV® surge protection technology · Green LED indicator provides status of protection · Type 3R rainproof enclosure for indoor/outdoor applications in plastic or metal · 3, 5 or 10-year product warranties · $7,500, $10,000 or $25,000 connected equipment warranties on appliances and electronics · CSA certified to ANSI/UL 1449, 3rd Edition Model # Modes of Protection Outdoor Type 3R Plastic IG1200RC3 3 (L1-N, L2-N, L1-L2) IG1240RC3 6 (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) Outdoor Type 3R Metal IG3240RC3 6 (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) Maximum Continuous Operating Voltage (L-N) (L-L) (L-G) (N-G) 150 300 150 300 300 150 150 300 300 150 Voltage Protection Rating (L-N) (L-L) (L-G) (N-G) No. of Leads/ Length Product Warranty Connected Equipment Warranty 700 1200 3, 30" 3-Year limited 3-Year / $7,500 700 1200 1200 700 4, 30" 5-Year limited 5-Year / $10,000 700 1200 1200 700 4, 30" 10-Year limited 10-Year / $25,000 ACCESSORIES Model Number Description IG1240FMP33 Flush Mount Kit for IG1200RC3 and IG1240RC3 IG3240FMP33 Flush Mount Kit for IG3240RC3 IG1240FMP33 IG3240FMP33 IG 1200 SERIES DIMENSIONS 3 7/16" 5/8" 4 3/16" 2 5/8" TYPE 2 INSTALLATION IG1240RC3/IG3240RC3 Main Breaker 2-Pole, 20 A circuit breaker shown SPD UNIT A=Black (Line) B=Black (Line) C=Neutral (White) D= Green (Ground) 1 3/4" 4 11/16" 4 3/16" 1" IG1200RC3 3 7/16" Type 2 Installation Main Breaker 5/8" 2-Pole, 20A circuit breaker shown 5 1/4" 1/4" IG1200RC3 SCALE 1:1 CORD NOT SHOWN 4 3/16" 2 5/8" A=Black (Line) B=Black (Line) C=Neutral (White) 1 3/4" Ratings Service Voltage 120/240 VAC Single-Phase Phase Single SPD Type 1, 2 In* 20 kA SCCR** 100 kA Max Surge Current Rating 50 kA Surge Protection Technology TPMOV® Operating Temperature -31°F - 185°F (-35°C - 85°C) Dimensions H x W x D 4 3/16" x 4 3/16" x 3 7/16" (106.4 mm x 106.4 mm x 87.3 mm) * Nominal Discharge Current ** Short Circuit Current Rating TYPE 1 INSTALLATION IG1200RC3 Line Grounded/ Neutral Line 120 v 240 v 120 v BLACK WHITE BLACK 120/240 VAC Three-wire with grounded neutral. Found at Service entrances and Meter Cans. IG1200RC3 Line Neutral Line Ground 120 v 240 v 120 v WHITE 120 v 120/240 VAC Three-wire with separate ground. Found in Main Disconnect Switches, Main Distribution panels, Load Centers Sub panels and equipment locations. BLACK BLACK IG1200RC3 LR38068 LR38068 TYPE 1 TYPE 2 Line Neutral Ground 120 v 120 v 0 v WHITE BLACK BLACK 120 VAC Two-wire single-phase with separate ground. Found at connections for individual pieces of equipment such as pumps and single-phase motors. NOTE: Both Black wires connect to Line. IG1240RC3/IG3240RC3 Line 240 VAC Line 120 VAC BLACK 120 VAC Neutral 120 VAC 120 VAC BLACK Ground WHITE GREEN 129 Surge Protection Type 1 or 2 SPD for Residential and Light Commercial Surge Protection IG2240-IMSK IG2280-OM IG2240-PK IG2200 Series TYPE 1 OR 2 SPD Protect expensive home appliances, electronics, HVAC equipment and more with SMARTGUARD® from Intermatic. The innovative SPD offers quick change modules that allow homeowners to easily monitor and maintain their home's surge protection system. These IMODULE® components include LED lights that indicate when protection has been compromised. A blue light indicates the SPD unit is ON and a green light indicates surge protection is active. Trusted, state-of-the-art TPMOV® (Thermally Protected Metal Oxide Varistor) surge protection technology eliminates the potentially hazardous failure modes that are commonly associated with standard MOV technology. Type 1 applications include outdoor installations before service entrances and utility meter cabinets. Type 2 applications include installations after service entrances. UL Listed to ANSI/UL 1449, 4 th Edition. Applications · Whole Home Protection Features · Six Modes of protection · TPMOV® surge protection technology · Module Power Switch, included on IG2240-IMSK, enables convenient disconnection of power at the SPD when replacing with an IMODULE® · Includes three IMODULE® cartridges with LED power and protection status lights · IMODULE® is quick and easy to replace, eliminating the need to install a new SPD unit · Tamper-proof IMODULE® doors, will only open when the IMODULE® is being inserted · Type 3R Rainproof Enclosure for indoor/outdoor applications in metal or plastic · 10-year product warranty · $25,000 or $50,000 connected equipment warranty for 10 years on appliances and electronics · UL certified to ANSI/UL 1449, 4th Edition Ratings Input Voltage Phase Modes of Protection Surge Protection Technology Max Surge Current Rating # of Leads Lead Gauge Operating Temperature Dimensions H x Dia Warranty Connected Equipment Warranty 120/240 VAC, 50/60 Hz Single 6 (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) TPMOV® 50 kA 4 #10 AWG, Tinned Copper -31°F - 185°F (-35°C - 85°C) See page 131 for dimensions 10-Year limited (Base), 3-Year limited (IMODULES®) 10-Year / $25,000 ACCESSORIES Model Number Description IG120RSM10K IMODULE® Replacement Module for SMARTGUARD® IG120RSM20 Replacement IMODULE® for IG2280 Series IG2200-FMK Flush Mount Kit for IG2240-IMSK and IG2280-IM Note: IG2240-IMSK includes flush mount kit IG120RSM10K IG2200-FMK Model # SPD In* Type (kA) Indoor/Outdoor Type 3 Plastic IG2240-PK 2 10 kA IG2280-P 2 20 kA Outdoor Type 3R Metal IG2280-OM 2 20 kA Indoor Type 1 Metal IG2240-IMSK 1, 2 10 kA IG2280-IM 2 20 kA *Nominal Discharge Current **Short Circuit Current Rating SCCR** (kA) Maximum Continuous Operating Voltage (L-N) (L-L) (L-G) (N-G) 10 kA 150 300 300 150 100 kA 150 300 300 150 100 kA 150 300 300 150 10 kA 150 300 300 150 100 kA 150 300 300 150 Voltage Protection Rating (L-N) (L-L) (L-G) (N-G) Lead Module Power Switch Length 800 1200 1500 700 18" No 800 1200 1500 700 18" No 800 1200 1500 700 18" No 800 1500 1500 700 32" Yes 800 1200 1500 700 18" No 130 DIMENSIONS FOR IG 2200 SERIES IG2240-IMSK and IG2280-IM 5" 2 1/2" 10 3/8" IG2280-OM 3/4" 1 5/8" 3/4" 1 5/8" 5 3/4" IG2240-PK 2 1/2" 5" 8 1/2" 1 5/8" 3 1/4" Surge Protection Type 1 or 2 SPD for Residential and Light Commercial Service Transformer Secondary Service Equipment Overcurrent device TYPE 1 INSTALLATION 120/240 VAC Single-Phase SPD Type 1 Wiring Diagram 120/240 VAC L1 (black) Neutral (white) L2 (black) GND (green) SPD TYPE 2 INSTALLATION 120/240 VAC Single-Phase *2 Pole 30 A circuit breaker in Service Panel. *C/B Line (black) Neutral (white) Line (black) SPD GND (green) SPD TYPE 2 WIRING DIAGRAM 120/240 VAC SINGLE-PHASE Main Breaker 2-Pole, 30A circuit breaker Black (Line) Black (Line) SPD UNIT Neutral (White) Green (Ground) Type 2 Installation REPLACEABLE IMODULE® Blue LED: Power indicator Green LED: Status indicator ON: Protection is being provided. OFF: IMODULE® is no longer providing protection. Replace IMODULE® as soon as possible. Alignment key of module Step 1 Turn off power a nd remove affected module Step 2 Insert new module Step 3 Turn on power; green light indicates s urge protection has been restored 131 Surge Protection Surge Protection Type 3 SPD for Commercial and Industrial Surge Protection IG Series, Surge Strips POINT-OF-USE SURGE STRIPS Type 3 Point-of-Use Surge Protective Devices (SPD) are designed for heavy industrial use with 3 modes of surge protection (L-N, L-G, N-G). Features a 15 A resettable breaker and #14 AWG SJT power cord with molded plug. CSA certified to ANSI/UL 1449, 3rd Edition. Applications · Surge Protection Features · Three Modes of protection · Metal Oxide Varistor (MOV) surge protection technology · 15 A resettable breaker · #14 AWG SJT power cord with molded plug · LED protection indicator · Extruded aluminum housing · 5-year product warranty · $5,000, $10,000 or $25,000 connected equipment warranties on appliances and electronics · CSA certified to ANSI/UL 1449, 3rd Edition IG112463 IG112663 Model # IG112463 IG112663 IG112663BLK10 IG206153 IG20B123 IG2012B153 Voltage Protection Rating (V) (L-N) (L-G) (N-G) 700 600 600 700 600 600 700 600 600 400 400 500 700 600 600 700 600 600 Cord Length 6' 6' 10' 15' 6' 15' Outlets Illuminating EMI/RFI Noise ON/OFF Switch Filtration 4 Yes No 6 Yes No 6 Yes No 6 No Yes 6 No No 6 No No Color White White Black White White White Product Warranty 5-Year limited 5-Year limited 5-Year limited 5-Year limited 5-Year limited 5-Year limited Connected Equipment Warranty 5-Year / $10,000 5-Year / $10,000 5-Year / $10,000 5-Year / $25,000 5-Year / $5,000 5-Year / $5,000 Ratings Input Voltage 125 VAC, 60 Hz SPD Type 3 MCOV* 130 Surge Protection Technology MOV Operating Temperature -4°F - 104°F (-20°C - 40°C) Dimensions See dimension drawings below Warranty 5-Year limited * Maximum Continuous Operating Voltage IG SERIES DIMENSIONS (SURGE STRIPS) IG112663, IG112663BLK10 IG112463 1 3/4" ACCESSORIES Model Number 24EG5133 Description Mounting Bracket Plate for Type 3 SPD Surge Strips 24EG5133 IG206153, IG20B123, IG2012B153 1 3/4" 2 1/8" 1 3/4" 10 15/16" 12 1/2" 1 1/2" X 6 15/16" 13/16" 7/8" 2 1/2" 2 3/8" 11/16" 1 7/8" 2 5/8" CORD NOT SHOWN 132 NOTES: SCALE 1:2 ALL DIMENSIONS ARE CLOSE APPROXIMATIONS ROUNDED TO THE NEARSEST 1/16TH" 1 1/2" 1 1/2" 8" 9 9/16" 1 1/2" 15/16" 13/16" 7/8" 2 1/2" 2 3/8" 11/16" 1 7/8" 2 5/8" CORD NOT SHOWN NOTES: SCALE 1:2 ALL DIMENSIONS ARE CLOSE APPROXIMATIONS ROUNDED TO THE NEARSEST 1/16TH" 14 3/16" 1 1/2" X 6 15 3/4" 15/16" 5 5/8" 11/16" 15/16" 1 1/16" 1 7/8" 2 3/4" 2 5/8" CORD NOT SHOWN NOTES:IG206153/ IG20B123/ IG2012B153 SCALE 1:2 ALL DIMENSIONS ARE CLOSE APPROXIMATIONS ROUNDED TO THE NEARSEST 1/16TH" Surge Protection Surge Protection Type 2 SPD - Includes Telephone and Coax Line Protection IG1300 Series TYPE 2 SPD The IG1300 Series provides protection for telephone and coax lines in addition to AC Power. Trusted, state-of-the-art TPMOV® (Thermally Protected Metal Oxide Varistor) surge protection technology eliminates the potentially hazardous failure modes that are commonly associated with standard MOV technology. A green LED indicator provides status of protection. The IG1300 Series Surge Protective Devices are designed for Type 2 applications for installations after service entrances. CSA certified to ANSI/UL 1449, 3rd Edition, UL 497A for phone line and UL 497B for coax cable. APPLICATIONS · Distribution Panel · Service Entrance FEATURES · Six modes of protection for AC SPD · TPMOV® surge protection technology for AC SPD · Green LED indicator provides status of protection · Provides telephone (analog phone line, modem or DSL) and coax line protection (cable TV, cable Internet or Satellite TV) · Type 3R plastic rainproof enclosure for indoor/outdoor installations · 5-year product warranty · $10,000 connected equipment warranty on appliances and electronics · CSA certified to ANSI/UL 1449, 3rd Edition · UL 497A for phone line protection · UL 497B for coax protection IG1300-2T-1C3 Model # Enclosure Type IG1300-2T-1C3 Outdoor type 3R plastic IG1300-4T-2C3 No. of Telephone No. of Coax Lines Lines Protected Protected 2 1 4 2 Maximum Continuous Operating Voltage (L-N) (L-L) (L-G) (N-G) 150 300 300 150 Voltage Protection Rating (L-N) (L-L) (L-G) (N-G) 700 1200 1200 700 LR38068 TYPE 2 Ratings Input Voltage 120/240 VAC, 50/60 Hz Phase Single SPD Type 2 Modes of Protection 6 (L1-N, L2-N, L1-G, L2-G, N-G, L1-L2) In (kA)* 20 kA SCCR (kA)** 50 kA Surge Protection Technology TPMOV® Operating Temperature -31°F - 185°F ( -35°C - 85°C) # of Leads / Length 4 / 24" Lead Gauge #12 AWG, Tinned Copper Dimensions H x W x D 10" x 6.5" x 4" (254 mm x 165 mm x 102 mm) Warranty 5-Year limited Connected Equipment Warranty 5-Year limited / $10,000 * Nominal Discharge Current ** Short Circuit Current Rating TYPE 2 INSTALLATION FIGURE 1 WANT TO KNOW MORE? Main (Off) A= Black (Line, right half) B= Black (Line, left half) C=White (Neutral) D= Green (Ground) Protect Industrial Facilities with PANELGUARD® Surge Protection Scan the QR code with your smartphone or tablet to learn how to eliminate the threat of a business-crippling power surge event by putting a PANELGUARD® Surge Protective Device at the heart of your industrial or commercial facility. 133 HVAC Surge and Power Protection Solutions Protect expensive HVAC equipment from unexpected power surge events, brownouts and short cycling with our robust surge protection solutions. These durable SPDs are simple to install and provide a lasting defense against power quality issues. Residential HVAC Systems Add the AG3000 and COMPRESSOR DEFENDERTM to residential HVAC systems to safeguard equipment long after the system manufacturer's warranty expires. The dynamic duo protects electrical components and provides lasting homeowner value. Distribution Panel Connect our surge protection solutions to residential or commercial distribution panels to provide a layer of coverage against power surge events. This method of installation can be completed in minutes and provides lasting protection. Storm Season Protection When dangerous weather strikes, safeguard heating and cooling system components, such as ductless mini-splits, heat pumps and central air conditioners, from sudden power quality issues with our robust SPDs. Advanced Technology AG3000 and COMPRESSOR DEFENDERTM solutions use TPMOV® surge protection technology to eliminates failure modes commonly associated with standard MOVs. This allows the SPDs to deliver superior performance over the long haul. Contents Type 1 or 2 Surge Protective Device136 HVAC Power Protection Device138 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more! HVAC Surge & Power Protection HVAC Surge & Power Protection Type 1 or 2 Surge Protective Device AG3000 AG3000 HVAC SURGE PROTECTIVE DEVICE Power surges are the silent killer for home appliances and HVAC equipment. Most homeowners protect their electronics, but leave more valued equipment unprotected. Surges can wipe out equipment and leave you searching for answers. Search no more. The easy-to-install AG3000 Surge Protective Device (SPD) is the perfect add-on for HVAC equipment. A green LED indicator provides the status of protection. Trusted, state-of-the-art TPMOV® (Thermally Protected Metal Oxide Varistor) technology eliminates the potentially hazardous failure modes that are commonly associated with standard MOV technology. UL Listed to ANSI/UL 1449, 4th Edition. APPLICATIONS · Distribution Panel · Service Entrance · HVAC Equipment Protection FEATURES · Three modes of protection: L-G, L-L, L-N · TPMOV® surge protection technology · Green LED indicator provides status of protection · Type 4X watertight and UV resistant plastic enclosure · 3-year product warranty · $7,500 connected equipment warranty for 3 years Ratings Service Voltage Phase SPD Type MCOV (Max Continuous Overvoltage) In (Nominal Discharge Rating) SCCR (Short Circuit Current Rating) Maximum Surge Current Rating Voltage Protection Rating (VPR) Modes of Protection Surge Protection Technology Lead Gauge Dimensions H x W x D Operating Temperature Warranty Connected Equipment Warranty 120/240 VAC Single-Phase Single 1, 2 L-N/G 150, L-L 300 20 kA 100 kA 50 kA L-L 1200, L1-N/G 700 3 (L1-N, L2-N, L1-L2) TPMOV® #10 AWG, Tinned Copper 3 7/8" x 1 5/8" x 4 3/16" (98 mm x 41 mm x 106.4 mm) -40°F - 158°F (-40°C - 70°C) 3-Year limited 3-Year / $7500 Model # AG3000 Enclosure Indoor/outdoor type 4X Want to Know More? Take residential or light commercial projects to new heights with the Intermatic AG3000 and Compressor DefenderTM. Our dependable new surge protective devices make for a smart add-on to seasonal HVAC maintenance contracts and require only 10 minutes to install. An ideal fit for central air conditioning systems, mini splits, heat pumps and more, the AG3000 and Compressor Defender provide layered surge protection and include a $7,500 warranty on all connected equipment. Once installed, they can be the difference when protecting a home or business from damaging power surge events, brown outs and short cycling issues. 136 HVAC Surge & Power Protection WIRING DIAGRAMS Line Neutral 120 V 120 V Line (BLACK) Line (BLACK) Ground 0 V 120 VAC Two wire single-phase with separate ground. Neutral (WHITE) Found at connections for individual pieces of equipment such as pumps, single phase motors and HVAC applications. NOTE: Both Black wires connect to Line. Typical Distribution Panel Installation Main Breaker 2-Pole, 20 A circuit breaker shown A=Black (Line) B=Black (Line) C=Grounded/Neutral (White) AC Disconnect black black white Main Service Panel HVAC Surge & Power Protection Type 1 or 2 Surge Protective Device AG3000 Wiring Diagram - Type 2 120 VAC L1 Grounded/Neutral AG3000 AG3000 Wiring Diagram - Type 2 240 VAC L1 Grounded/Neutral L2 AC Disconnect black white black Main Service Panel DIMENSIONS 13/16" 13/16" 1 5/16" 1" 4 3/16" 1" 1 1/8" 1 5/8" 3 7/8" 3 7/8" AG3000 1" 11/16" 1/2" NPSM 137 16" 13/16" 1 5/16" 1" 4 3/16" 1" 11/16" 1/2" N AG3 SCAL 1/8" HVAC Surge & Power Protection HVAC Surge & Power Protection HVAC Power Protection Device CD1-024R COMPRESSOR DEFENDERTM UNDERVOLTAGE, SURGE AND SHORT CYCLE PROTECTIVE DEVICE CD1-024R Ratings Input Voltage Thermostat Relay SPD Type Modes of Protection Control Output Current Rating Max Continuous Overvoltage (MCOV) Voltage Protection Rating (VPR) Nominal Discharge Rating (ln) SCCR (Short Circuit Current Rating) Maximum Surge Current Rating Undervoltage Response Time Power Disruption Response Time Short Cycle Delay Enclosure Lead Gauge Undervoltage Pickup Table Operating Temperature Warranty Connected Equipment Warranty *Typical Response Time 120/208-240 VAC Single Phase, 60 Hz Normally Closed Relay, 24 VAC 2 3 (L1-N, L2-N, L1-L2) 2 A @ 24 VAC, isolated NC contact L-N/G: 150, L-L: 300 L-N/G: 700, L-L: 1200 20 kA 100 kA 50 kA 5 line cycles* 3 line cycles* 3 min Outdoor type 3 #10 AWG, Tinned Copper Nominal System Voltage Range B Protection 120 VAC 104 208 VAC 180 240 VAC 208 -40°F - 158°F (-40°C - 70°C) 3-Year limited 3-Year/ $7,500 The Compressor Defender is the only all-in-one undervoltage and surge power protection device on the HVAC Market, providing protection for central A/C and heat pump condensing units and their associated motors, controls and components--both electronic and mechanical. It can be installed inside the condensing unit or externally on the outdoor A/C disconnect. Autosense voltage technology protects at any voltage from 120-240 VAC, making it an ideal solution for residential or light commercial installations. Trusted, state-of-the-art TPMOV® (Thermally Protected Metal Oxide Varistor) surge protection technology eliminates the potentially hazardous failure modes that are associated with standard MOV technology. The device is also designed with integrated 3-minute short cycle time delay protection. APPLICATIONS · Distribution Panel · Service Entrance · HVAC Equipment Protection FEATURES · TPMOV® surge protection technology · 3-year, $7500 connected equipment warranty · Auto-sense voltage technology · Quick-reacting, 5-line cycle undervoltage response time · 120/208-240 VAC universal input · 24 VAC/VDC, 2 A control thermostat output · 3-minute short cycle time delay ·Two LED indicators provide real time status for quick and easy troubleshooting and functional visibility for end users ·Surge protection complies with the latest UL 1449, 4th Edition, surge protective device requirements ·Undervoltage protection complies with AHRI standard 110-2016 Range B Protective Device · Undervoltage Response Time: 5 line cycles* · Power Disruption Response Time: 3 line cycles* · Type 3 Outdoor, UV resistant plastic enclosure *Typical Response Time Model # CD1-024R Enclosure Outdoor type 3 138 HVAC Surge & Power Protection WIRING DIAGRAMS Applicable to both single- and two-stage central A/C & heat pumps. Contactor Wiring From Compressor DefenderTM BLACK RED Y1 24 VAC C Compressor Contactor HVAC Surge &Power Protection HVAC Power Protection Device MOUNTING Mounting Inside Panel/ Condenser Bracket Included Sheet Metal Screw Typical 208/240 VAC Recommended Application Line Ground Line Typical 208/240 VAC Recommended Application Black White Black Line Line A/C Disconnect Load Load 24 VAC Y1 Y1 LED Diagnostic Indicator Key Condition Surge Protection No Surge Protection Undervoltage Short Cycle Protection Unit Power Lost Green LED ON OFF Flash OFF Red LED - Flash - OFF Typical 120 VAC Application Line Line NOTE: BothBLbAlaCcKk wires connect to Line. NOTE: Both blTaycpkicwailre1s20 VAC connecAt ptoplLicinaetio. n 120 VAC Neutral 120 VAC Line Line (BLACK) (BLACK) Grounded0 VAC WHITE Ground BLACK w/WHITE SLEEVE 120 VAC two wire single phase Grounded/ with separate g1ro2u0nVdA. C two-wire single-phaseNeutral Found at connewcittihonssepfoarraintdeivgirdouuanl d. (WHITE) pieces of equipFmoeunnt,dsautcchoansnepcutmiopnss, for individual single phase mpoiteocrse,saonfdeHquViApCment, such as pumps, applications. single-phase motors, and HVAC applications. 24 VAC 24 VAC Y1 Y1Y1 Y1 139 Weatherproof Cover Solutions Keep outdoor receptacles and outlets shielded from the elements with our versatile lineup of weatherproof covers. Available in plastic, extra-duty plastic and extra-duty die-cast options, our rugged solutions provide lasting code-compliant protection. Outdoor Receptacle Protection Ensure outdoor receptacles stay protected all year long with our wide selection of in-use weatherproof covers. Our industry-leading solutions are available in a variety single- and double-gang models and are an excellent choice in residential, commercial and industrial applications. Simple Code Compliance Secure and code compliant, our in-use covers are the perfect solution for commercial applications. They're available in a variety of colors, which can be used to match with business branding, as well as vertical and horizontal orientations. Backyard Aesthetics Do away with unflattering "wall warts" by installing our sleek, low-profile expandable in-use covers in residential applications. These modern covers enhance building aesthetics and include an expandable front window that can be collapsed to save space when not in use. Vehicle Charging and Power Access Keep outlets in outdoor applications such as vehicle charging and campsite power access protected from the elements with our rugged in-use weatherproof covers. Available extra-duty models align with commercial and industrial code standards. Contents Low-Profile Extra-Duty Plastic Covers142 Extra-Duty Die-Cast In-Use Covers144 Extra-Duty Plastic In-Use Covers146 Plastic In-Use Covers148 Accessories 152 Code Compliance153 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Weatherproof Covers Weatherproof Covers Low-Profile Extra-Duty Plastic Covers Low-Profile, Expanded Possibilities Our low-profile expandable in-use weatherproof covers provide a sleek, easy-to-use alternative to traditional in-use weatherproof cover options. The unique design of the WP6000, WP6200, WP7000 and WP7200 Series includes an expandable front window that can be collapsed to save space when not in use. This improves aesthetics while delivering dependable, code-compliant protection for a range of outdoor applications. Available in standard and extra-duty configurations, our new plastic low-profile in-use covers are an excellent upgrade to any home or business. Includes: · Improved Aesthetics Unlike traditional covers, Low-Profile In-Use Covers include an expandable front window that can be collapsed to save space when not in use · Simple, Secure Access An innovative new design provides a no-hassle latch with lockable hasp that can be opened effortlessly with one hand · Quick Installation GFCI pre-set; keyhole slots help electrical contractors complete installation in minutes · Configuration Options Available in single-gang and double-gang configurations, as well as standard and extra-duty; select white, gray or bronze color options; single-gang models accommodate both vertical and horizontal installations · Code Compliant WP7000 and WP7200 Series Low-Profile In-Use Covers comply with 2020 NEC Article 406.9 (B)(1) for wet locations and Extra-Duty applications; CEC 26-708 Compliant; RoHS Compliant Upgrade today with the trusted market leader for in-use weatherproof covers. For more information, visit intermatic.com/low-profile-in-use-cover. 142 Weatherproof Covers Low-Profile Extra-Duty Plastic In-Use Weatherproof Covers SINGLE-GANG COVERS & DOUBLE-GANG COVERS Plastic In-Use Weatherproof Covers are easy to install and include a gasket, mounting screws, base, cover assembly and inserts to meet the needs of a variety of applications. APPLICATIONS · Receptacle Protection FEATURES · 100% Paintable surface · Complies with 2020 NEC Article 406.9 (B)(1) for wet locations and extra-duty applications · CEC Section 26-708 compliant · UL Certified for Type 3R outdoor enclosures · Meets requirements for cold impact testing: -60° F (-51° C) · Heavy-duty UV stabilized polycarbonate cover, mounting base, and inserts · 1/8" (3 mm) thick, neoprene gasket with slits for mounting screws · Lockable hasp: All models accept up to 0.19" dia shank · Impact rated: 12 lbf. impact test to ensure cover remains intact · Reinforced hinge pin designed to exceed 40 lbf. hinge hang/stress test · Warranty: 1-year limited · NEW Faster Installation, Pre-Set for GFCI, No insert required SINGLE-GANG COVERS · Two inserts provided with all models that allow each model to meet multiple installations (up to 8 configurations) DOUBLE-GANG COVERS ·Four inserts provided with all models that allow each model to meet multiple installations (up to 16 configurations) Weatherproof Covers Low-Profile Extra-Duty Plastic Covers WP7000BR SINGLE-GANG - VERTICAL/HORIZONTAL Model # Color WP6000G Clear, Gray WP6000W Clear, White WP6000BR Bronze, Clear WP7000G Clear, Gray WP7000W Clear, White WP7000BR Bronze, Clear WP7003G Clear, Gray For accessories see page 152 Style Standard Standard Standard Extra-Duty Extra-Duty Extra-Duty Extra-Duty Depth 1.5" (38.1 mm) 1.5" (38.1 mm) 1.5" (38.1 mm) 1.5" (38.1 mm) 1.5" (38.1 mm) 1.5" (38.1 mm) 1.5" (38.1 mm) DIMENSIONS SINGLE-GANG WP7200G DOUBLE-GANG Model # WP6200G WP7200G WP7200W WP7200BR For accessories see page 152 Color Clear, Gray Clear, Gray Clear, White Bronze, Clear Style Standard Extra-Duty Extra-Duty Extra-Duty Depth 1.5" (38.1 mm) 1.5" (38.1 mm) 1.5" (38.1 mm) 1.5" (38.1 mm) DOUBLE-GANG 143 Weatherproof Covers Weatherproof Covers Extra-Duty Die-Cast In-Use Covers WP3110MXD WP1010HMXD WP1010MXD WP1250MVXD Extra-Duty Die-Cast In-Use Weatherproof Covers SINGLE-GANG COVERS & DOUBLE-GANG COVERS Die-Cast In-Use Aluminum Weatherproof Covers are extra-duty rated and easy to install. Heavy-duty die-cast aluminum construction ensures long-lasting durability. Covers come with a gasket, mounting screws, base, cover assembly and inserts to meet the needs of a variety of applications. APPLICATIONS · Engine Block Heaters · Receptacle Protection · Walk-in Refrigeration Cooler/Freezer FEATURES · Complies with 2020 NEC Article 406.9 (B)(1) for wet locations and extra-duty applications · Exceeds CEC Article 26-708 · UL Certified for Type 3R outdoor enclosures · Meets requirements for cold impact testing: -60° F (-51° C) ·Heavy-duty die-cast aluminum cover and mounting base with UV stabilized polycarbonate inserts · 1/8" (3 mm) thick, neoprene gasket with slits for mounting screws · Lockable hasp: All models accept up to 1/4" (6 mm) dia shank · Impact rated: 12 lbf. impact test to ensure cover remains intact · Reinforced hinge pin designed to exceed 40 lbf. hinge hang/stress test · Warranty: 1-year limited SINGLE-GANG ·Three inserts provided with all models that allow each model to meet multiple installations (up to 8 configurations) · Max cord size: #12 AWG or smaller DOUBLE-GANG ·Six inserts provided with all models that allow each model to meet multiple installations (up to 70 configurations) · Max cord size: #12 AWG or smaller WP1030MXD WP1250MXD SINGLE-GANG Model # Color WP1010MXD Gray WP1010HMXD* Gray WP1250MVXD Gray WP3110MXD Gray *Note: WP1010HMXD is a horizontal mount. For accessories see page 152 Depth 3 1/8" (79 mm) 3 1/8" (79 mm) 4 5/8" (117 mm) 2 3/4" (70 mm) Flexi-Guard Inserts WP17 WP17 WP17 WP17 DOUBLE-GANG Model # Color WP1030MXD Gray WP1250MXD Gray For accessories see page 152 Depth 3 1/8" (79 mm) 4 5/8" (117 mm) Flexi-Guard Inserts WP217 WP217 144 Weatherproof Covers DIMENSIONS WP COVERS S ARE ROUNDED T 1/16" 4 5/8" 3 1/8" 2 3/4" 1 7/16" 5/16" 1 3/4" 2 1/8" Weatherproof Covers Extra-Duty Die-Cast In-Use Covers 3 13/16" 6 3/8" 5/16" SINGLE-G4AN7G/16" ARE OUNDED 1/16" ED 5/16" 5 3/4" 1 13/16" 4 7/16" 3 1/8" 1 7/16" 5/16" 5 3/4" 5/16" DOUBLE-GANG 1 13/16" WP10103HM1X/D16" 2 11/16" 3 1/8" 1 7/16" ST WP COVERS 1:4 ONS ARE D ROUNDED EST 1/16" P COVERS 5/16" 5/16" 5 5/8" 3613/1/86"" 2 11/16" 6 3/8" 1 7/16" 3 1/8" 4 5/8" RE UNDED 145 16" 5/16" Weatherproof Covers Weatherproof Covers Extra-Duty Plastic In-Use Covers WP5000G Clear/Gray Gray Beige Black White Bronze WP5500C WP5103C Extra-Duty Plastic In-Use Weatherproof Covers SINGLE-GANG COVERS & DOUBLE-GANG COVERS Plastic In-Use Weatherproof Covers are extra-duty rated and easy to install. Covers come with a gasket, mounting screws, base, cover assembly and inserts to meet the needs of a variety of applications. APPLICATIONS · Receptacle Protection FEATURES · Complies with 2020 NEC Article 406.9 (B)(1) for wet locations and extra-duty applications · CEC Section 26-708 compliant · UL Certified for Type 3R outdoor enclosures · Meets requirements for cold impact testing: -60° F (-51° C) · Heavy-duty UV stabilized polycarbonate cover, mounting base, and inserts · 1/8" (3 mm) thick, neoprene gasket with slits for mounting screws · Lockable hasp: All models accept up to 1/4" (6 mm) dia shank · Impact rated: 12 lbf. impact test to ensure cover remains intact · Reinforced hinge pin designed to exceed 40 lbf. hinge hang/stress test · Warranty: 1-year limited SINGLE-GANG · NEW Faster Installation, Pre-Set for GFCI, No insert required ·Two inserts provided with all models that allow each model to meet multiple installations (up to 16 configurations) · Max cord size: (2) #14 AWG or (1) #12 AWG DOUBLE-GANG ·Six inserts provided with all models that allow each model to meet multiple installations (up to 70 configurations) · Max cord size: (2) #12 AWG or (1) #10 AWG · 30/50 A (1) #6 AWG SINGLE-GANG - VERTICAL/HORIZONTAL Clear/Gray Gray Black WP5000C WP5000G WP5000BL WP5100C WP5100G WP5100BL WP5103C* WP5110C * Includes 3/0 adapter plate for 3" (76 mm) round box. For accessories see page 152 White WP5000W WP5100W DOUBLE-GANG - VERTICAL Clear/Gray Gray Black White WP5220C WP5220G WP5220BL WP5220W WP5221C WP5225C WP5225G WP5240C WP5500C * Includes 3/0 adapter plate for 3" (76 mm) round box. **30/50 A = 4 3/4" (121 mm) depth. For accessories see page 152 Bronze WP5100BR Depth 2 1/4" (57 mm) 2 3/4" (70 mm) 2 3/4" (70 mm) 3 5/8" (92 mm) Flexi-Guard Inserts WP17 WP17 WP17 WP17 Beige WP5220B Depth 2 1/4" (57 mm) 2 1/4" (57 mm) 2 3/4" (70 mm) 3 5/8" (92 mm) 4 3/4" (121 mm)** Flexi-Guard Inserts WP217 WP101, WP102 WP217 WP217 WP107, WP213 146 Weatherproof Covers DRAFT SINGLE-GANG Weatherproof Covers Extra-Duty Plastic In-Use Covers DOUBLE-GANG /8" 1/16" 1 11/16"MIN 1 13/16"MAX 2" 3 13/16" 3 1/4" 2 3/4" 2 1/4" 3 5/8" 5 5/8" NOTES: 1. KNOCK OUT SPACING AND DIMENSIONS SAME FOR ALL VERSIONS OF DOUBLE GANG EXTRA DUTY PLASTIC. 2. BASE DIMENSIONS ARE THE SAME FOR ALL VERSIONS. 3. 4. DIMENSIONS SCALE 1:2. ARE APPROXIMATE AND RODUONUDBLEEDGATNOGNSTEAANRDEARSDTD1E/P3T2HTSH". DRAFT 6 5/16" 30 2 1/8" 2 5/8" 6 5/8" 1 11/1163"/M8"IN 1 13/16"MAX 3 1/16" 1 3/16" SCREW HOLE LOCATIONS 7/8" 337/58/"16" KEY HOLE, CENTER4H1O1L/1E6A" ND ROUND KNOCK OUT 3 13/16" WP5103C 3 1/4" CL A OUT SPACING AND DIMENSIONS SAME FOR ALL VERSIONS OF SINGLE GANG DUTY PLASTIC. DIMENSIONS ARE THE SAME FOR ALL VERSIONS. SIONS ARE APPROXIMATE AND ROUNDED TO NEAREST 1/16TH". 1:2. 2" 5 5/8" 6 5/16" DOUB2L1E/-8G"ANG 30/50 A 2 3/4" 2 1/4" 3 5/8" 5 1/4" DOUBLE GANG STANDARD DEPT 2 5/8" 1 3/8" 1 7/8" 3 1/16" 1 3/16" 3 5/16" MOUNTING SCREWDOHUOBLLEEGALNOG CSTAANTDIOARNDSDEPTHKSEY HOLE, CENTER HOLE AND ROUND KNOCK OUT A 30/50 AMP DOUBLE GANG EXTRA DUTY PLASTIC NOTES: 1. KNOCK OUT SPACING AND DIMENSIONS SAME FOR ALL VERSIONS OF SINGLE GANG EXTRA DUTY PLASTIC. 2. BASE DIMENSIONS ARE THE SAME FOR ALL VERSIONS. 3. DIMENSIONS ARE APPROXIMATE AND ROUNDED TO NEAREST 1/16TH". 4. SCALE 1:2. 147 Weatherproof Covers Weatherproof Covers Plastic In-Use Covers WP3103C Plastic In-Use Weatherproof Covers, Single-Gang, 16 Configurations SINGLE-GANG COVERS Plastic In-Use Weatherproof Covers are easy to install and include adhered gasket, mounting screws, base, cover assembly and inserts to meet the needs of a variety of applications. APPLICATIONS · Receptacle Protection FEATURES · Complies with 2020 NEC Article (406.9 (B)(1) for damp and wet locations · UL Certified for Type 3R outdoor enclosures · Meets requirements for cold impact testing: -60° F (-51° C) · Heavy-duty UV stabilized polycarbonate cover, mounting base and inserts · 1/8" (3 mm) thick, pre-adhered neoprene gasket with slits for mounting screws · Lockable hasp: All models accept up to 1/4" (6 mm) dia shank, except WP3100C & WP3103C accept up to 1/8" (3 mm) dia shank ·Three inserts provided with all models that allow each model to meet multiple installations (up to 16 configurations) · Max cord size: (2) #14 AWG or (1) #12 AWG · Mounts vertically or horizontally · Warranty: 1-year limited WP1100C WP3100 WP1110C SINGLE-GANG -WVEPRT1IC1A0L/0HOCRIZONTAL HINGE Model # Color Depth WP3100C Clear 2 3/4" (70 mm) WP3103C WP1100C WP1100WC Clear CWleaPr 1110C WWhiPte1100C 2 3/4" (70 mm) 2 3/4" (70 mm) 2 3/4" (70 mm) WP1110C Clear For accessories see page 152 3 5/8" (92 mm) Flexi-Guard Inserts WP17 WP17 WP17 WP17 WP17 WDIMPEN3SI1ON0S 0C WP3100C 4.06" 4.06" 5.757.7"7" WP3100 148 3.02" 1.533".021" .49" 1.53" 1.49" 3-5/8" 2-3/4" 3-5/8" 2-3/4" DDiaia. .00.5."5" 2..7755"" INNSSIIDDEE DEEPPTTHH WP1100C, WP1110C 5-3/8" 5-3/8" 3-1/2" 3-1/2" Weatherproof Covers Plastic In-Use Weatherproof Covers, Single-Gang, 8 Configurations SINGLE-GANG COVERS Plastic In-Use Weatherproof Covers are easy to install and include adhered gasket, mounting screws, base, cover assembly and inserts to meet the needs of a variety of applications. APPLICATIONS · Receptacle Protection FEATURES · Complies with 2020 NEC Article (406.9 (B)(1) for damp and wet locations · UL Certified for Type 3R outdoor enclosures · Meets requirements for cold impact testing: -60° F (-51° C) · Heavy-duty UV stabilized polycarbonate cover, mounting base and inserts · 1/8" (3 mm) thick, pre-adhered neoprene gasket with slits for mounting screws ·Three inserts provided with all models that allow each model to meet multiple installations (up to 8 configurations) · Max cord size: (2) #14 AWG or (1) #12 AWG · Warranty: 1-year limited Weatherproof Covers Plastic In-Use Covers WP1000C DIMENSIONS WP1000HC SINGLE-GANG - VERTICAL HINGE Model # Color WP1000C Clear WP1000GC Gray WP1010C Clear For accessories see page 152 Depth 2 1/4" (57 mm) 2 1/4" (57 mm) 3 1/8" (79 mm) Flexi-Guard Inserts WP17 WP17 WP17 SINGLE-GANG - HORIZONTAL HINGE Model # Color WP1000HC Clear WP1000HGC Gray WP1010HC Clear WP1150C Clear For accessories see page 152 Depth 2 1/4" (57 mm) 2 1/4" (57 mm) 3 1/8" (79 mm) 4 3/4" (121 mm) Flexi-Guard Inserts WP17 WP17 WP17 WP17 4-3/4" WP1150C 5-3/8" 3-1/2" 149 Weatherproof Covers Weatherproof Covers Plastic In-Use Covers Plastic In-Use Weatherproof Covers, Double-Gang DOUBLE-GANG COVERS Plastic In-Use Weatherproof Covers are easy to install and include a gasket, mounting screws, base, cover assembly and inserts to meet the needs of a variety of applications. APPLICATIONS · Receptacle Protection FEATURES · Complies with 2020 NEC Article (406.9 (B)(1) for damp and wet locations · UL Certified for Type 3R outdoor enclosures · Meets requirements for cold impact testing: -60° F (-51° C) · Heavy-duty UV stabilized polycarbonate cover, mounting base and inserts · 1/8" (3 mm) thick neoprene gasket with slits for mounting screws · Two inserts provided with all models for multiple installations · Max cord size: (2) #14 AWG or (1) #12 AWG, WP1050 (2) #14 AWG or (1) #10 AWG · Warranty: 1-year limited WP1020C DIMENSIONS 8" WP1030C WP1020C 3-1/8" WP1030C 2-1/4" WP1020C 5 -1/2" 4 - 3/4" WP1050 5 -1/2" 5" DOUBLE-GANG - VERTICAL HINGE Model # Color WP1020C Clear WP1030C Clear WP1050 Clear For accessories see page 152 Depth 2 1/4" (57 mm) 3 1/8" (79 mm) 4 3/4" (121 mm) Flexi-Guard Inserts WP101, WP102 WP101, WP102 WP102, WP107 5" 6" 5" 150 Weatherproof Covers Plastic In-Use Weatherproof Covers, Double-Gang, 70 Configurations DOUBLE-GANG COVERS Plastic In-Use Weatherproof Covers are easy to install and include a gasket, mounting screws, base, cover assembly, and inserts to meet the needs of a variety of applications. APPLICATIONS · Receptacle Protection FEATURES · Complies with 2020 NEC Article (406.9 (B)(1) for damp and wet locations · UL Certified for Type 3R outdoor enclosures · Meets requirements for cold impact testing: -60° F (-51° C) · Heavy-duty UV stabilized polycarbonate cover, mounting base and inserts · 1/8" (3 mm) thick neoprene gasket with slits for mounting screws ·Six inserts provided with all models that allow each model to meet multiple installations (up to 70 configurations) · Max cord size: (2) #14 AWG or (1) #12 AWG, WP1250 (2) #14 AWG or (1) #10 AWG · Warranty: 1-year limited Weatherproof Covers Plastic In-Use Covers DOUBLE-GANG - VERTICAL HINGE Model # Color WP1220C Clear WP1230C Clear WP1250C Clear For accessories see page 152 Depth 2 1/4" (57 mm) 3 1/8" (79 mm) 4 3/4" (121 mm) Flexi-Guard Inserts WP217 WP217 WP217 DIMENSIONS WP1250 151 Weatherproof Covers Weatherproof Covers Accessories Flexi-Guard Inserts All original series weatherproof covers include Flexi-guard inserts and mounting screws. Simply place the insert into the cover, rotate as needed, then snap it into place. ACCESSORIES Model # WP17 WP217 WP101 WP102 WP107 WP213 Description Single-Gang Inserts (3) Double-Gang Inserts (6) Double-Gang Duplex Insert Double-Gang GFCI Insert Double-Gang Round Insert, 1 3/8", 1 5/8", 1 3/4" Double-Gang Round Insert, 2 1/8", 2 5/8" 152 Weatherproof Covers Code Compliance Weatherproof Covers Rugged Design, Code-Compliant Protection Our durable die-cast, low-profile, and plastic in-use weatherproof covers offer rugged protection in all types of applications. STAY COMPLIANT 2020 NEC CODE, ARTICLE 406.9 (B)(1) Intermatic Weatherproof Covers meet or exceed the latest NEC requirements for extra-duty applications and wet locations. ·For the 2020 NEC, all 15 and 20 ampere, 125 and 250 volt receptacles installed in a wet location still must have an enclosure and covers that are weatherproof whether an attachment plug cap is inserted or not. ·A revision now requires all enclosures and covers installed in wet locations for 15 and 20 ampere, 125 and 250 volt receptacles to be listed, and of the "extra-duty" type, not just boxes supported from grade. ·This requirement is now also required for dwelling units as well. The requirement for weather-resistant type receptacles in wet locations is still applicable in the 2020 NEC. This change also provoked changes to Article 590.4(D)(2) for extra-duty covers for all 15 and 20 ampere, 125 and 250 volt receptacles installed at temporary installations in a wet location. · CEC Section 26-708 compliant. · Standard weatherproof cover compliance guidelines apply only to 2020 Article 314.15. WATCH AND LEARN Our durable line-up of Die-cast and Plastic Weatherproof Covers offers long-lasting protection in all types of rugged applications: industrial, commercial, manufacturing, residential, and more! Tired of fussing with bulky outdoor weatherproof covers? Upgrade to new WP6000 and WP7000 Series Low-Profile Expandable In-Use Weatherproof Covers from Intermatic. 153 Pool and Spa Solutions Control and Protect your valuable pool equipment and landscape lighting with our affordable, time-saving pool and spa solutions. From timer controls and enclosures to safety transformers and surge protective devices, our products provide lasting value to pool owners while simplifying installation and setup. Power Management and Protection Lay a solid foundation with our versatile control panels and robust surge protection solutions. Designed to streamline installation, our load centers offer a variety of options and can be paired with SPDs to provide a lasting defense against harmful power quality issues. Underwater Lighting Expand the functionality of underwater luminaires by installing our safe, reliable transformer solutions. Hybrid solutions like our COMBOCONNECTTM Junction Box Transformer reduce clutter on the pool pad while maximizing performance. Valve Control Find the perfect flow for pool and spa equipment, fountains, pumps and more with our easy-to-operate valve actuators. These solution reduce the steps needed for cam adjustment and can be used in a variety of water applications. Landscape Design Elevate backyard décor with a selection of Intermatic timer controls. These solutions can be used to control ON/OFF schedules of garden and patio lights, as well as schedules for water features and outdoor decorations. 154 Contents Mechanical Controls...............156 Mechanical Control Centers...158 Load Center............................164 Transformers...........................166 Junction Boxes.......................167 Electronic Controls..................168 Electronic Control Centers .....170 Wireless Electronic Controls....173 Wireless Add-On Components ..174 Valve Actuators.......................175 Freeze Protection....................176 Remote Controls.....................177 Air Switch................................178 Panel Mount Timers................179 Surge Protection.....................180 Specialty Controls...................181 Electronic Panel Mount Timers...182 Portable Timers & Enclosures...184 Accessories ............................185 Additional Solutions and Resources Ready to get started? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Pool & Spa Pool & Spa Mechanical Controls T101M 24-Hour Mechanical Time Switch Only T100 SERIES Heavy-duty mechanical time switches control a single load. Highest HP ratings in the industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Applications · Timing/Scheduling ON/OFF · Pump control Features · Highest motor load ratings in the industry · Minimum ON/OFF times of 1 hour · Up to 12 ON/OFF operations per day · One ON and one OFF tripper included · Can be installed in most Intermatic enclosures · Available with pool heater protection · Teeter-type terminals for multiple load connections · Can be installed in most Intermatic enclosures Model # Switch Type Input Voltage Without Pool Heater Protection T101M SPST T103M DPST 120 VAC, 60 Hz T104M T106M DPST 208-277 VAC, 60 Hz 1 NO/1 NC, SPDT With Pool Heater Protection T104M201 DPST 208-277 VAC, 60 Hz Electronic Ballast Inductive Restive (Heater) Tungsten (Incandescent) Pilot Duty 16 A, 120 VAC 16 A, 120-277 VAC 16 A, 120-277 VAC 16 A, 208-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz WIRING DIAGRAMS Ratings Motor Heater Control Circuit Resistive Inductive Electronic Ballast Tungsten Pilot Duty Max Power Consumption Operating Temperature Warranty 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz 10 A, 250 VAC MAX, 60 Hz See Model Chart See Model Chart See Model Chart See Model Chart See Model Chart 3 W -40°F - 130°F (-40°C - 54°C) 1-Year limited NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details. 2. Diagrams above are only two of the many variations this Panel can accommodate. 156 ACCESSORIES For accessories and replacement parts please see page 184-185. Pool & Spa Pool & Spa Mechanical Controls 24-Hour Mechanical Time Switch in Enclosure T100 SERIES Heavy-duty mechanical time switches control a single load. Highest HP ratings in the industry for loads up to 40 amps, providing direct 24 hr. control of most loads. Applications · Heater Thermostat Control · Motor Control · Pump Control Features · Highest motor load ratings in the industry · Minimum ON/OFF times of 1 hour · Up to 12 ON/OFF operations per day · One ON and one OFF tripper included · Available with pool heater protection · Teeter-type terminals for multiple load connections T104P3 T104R3 Model # Switch Type Input Voltage Electronic Ballast Inductive Restive (Heater) Tungsten (Incandescent) Pilot Duty Enclosure Without Pool Heater Protection T101P3 T104P3 T106P3 SPST DPST 1 NO/1 NC 120 VAC, 60 Hz 208-277 VAC, 60 Hz 208-277 VAC, 60 Hz 16 A, 120 VAC 16 A, 120-277 VAC 16 A, 208-277 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz Outdoor type 3R plastic T101R3 SPST T104R3 DPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz Outdoor type 208-277 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 3R metal With Pool Heater Protection T101P201 SPST T104P201 DPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-480 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 1000 VA, 120-480 VAC, 60 Hz Outdoor type 208-277 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 3R plastic T101R201 SPST T104R201 DPST 120 VAC, 60 Hz 16 A, 120 VAC 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz Outdoor type 208-277 VAC, 60 Hz 16 A, 120-277 VAC 40 A, 120-277 VAC, 60 Hz 40 A, 120-480 VAC, 60 Hz 40 A, 120-277 VAC, 60 Hz 1000 VA, 120-277 VAC, 60 Hz 3R metal Note: The heater protection switch (fireman switch) is closed when the time switch contacts are open to allow remote operation of the heater. A flow or pressure switch therefore must always be part of the heater control circuit. Ratings Motor Heater Control Circuit Resistive Inductive Ballast Electronic Ballast Tungsten Pilot Duty Max Power Consumption Operating Temperature Enclosure Dims (H x W x D) Plastic Outdoor Metal Indoor Knockout Dimensions Bottom Left Right Back Warranty 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz 10 A, 250 VAC MAX, 60 Hz See Model Chart See Model Chart See Model Chart See Model Chart See Model Chart 3 W -40°F - 130°F (-40°C - 54°C) 10" x 6.5" x 4" (254 mm x 165.1 mm x 101.6 mm) 10.125" x 6.5" x3.625" (257.2 mm x 165.1 mm x 92.1 mm) (2) 1/2" and 3/4" (1) combination 1/2" and 3/4" (1) combination 1/2" and 3/4" (1) combination 1/2" and 3/4" 1-Year limited ACCESSORIES For accessories and replacement parts please see page 184-185. 157 Pool & Spa Pool & Spa Mechanical Control Centers T10004R WIRING DIAGRAMS T10604R Control 2 speed pumps Control System with Type 3R Power Center T10000R SERIES The T10000R Series Control Centers feature an all-weather enclosure and can contain control center only, one or two heavy duty timer mechanisms. Applications · Distribution/Control Panel · Motor Control · Pump Control Features · Available with one or two heavy-duty time switch mechanisms · Accepts PF1000M, P1403ME, P1353ME, P4043ME, P4243ME, T100M OR RC2000M Series mechanisms · Load center dead front has two knockouts for switches or GFCIs and one on the side · Wiring devices may be installed in these load centers with the use of Standoffs, sold separately (21T156A and 21T166A) · Control two-speed pumps with the T10604R · Electrostatically applied light beige finish. Model # Mechanism Switch Type Mechanism Supply Voltage T10000R Power Center Only T10004R (1) T104M DPST 208-277 VAC, 60 Hz T10006R (1) T106M 1 NO/1 NC 208-277 VAC, 60 Hz T10101R (2) T101M SPST 120/120 VAC, 60 Hz T10404R (2) T104M DPST 208-277 VAC, 60 Hz T10604R T106M & T104M SPDT/DPST 208-277 VAC, 60 Hz T12404R* T104M201 & T104M DPST 208-277 VAC, 60 Hz * The heater protection switch (fireman switch) is closed when the time switch contacts are open to allow remote operation of the heater. A flow or pressure switch therefore must always be part of the heater control circuit. Ratings Center Rating Resistive Inductive Tungsten Pilot Duty Max Power Consumption Motor Operating Temperature Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Right Back Warranty 92 Amp per leg, 168 Amp Max. 120-240 VAC or 120-208 VAC single phase - 60 Hz 30 A, 120-240 VAC, 60 Hz 30 A, 120-240 VAC, 60 Hz 30 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 3 W 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz -40°F - 130°F (-40°C - 54°C) 12.875" x 10.875" x 4.75" (327 mm x 276.2 mm x 120.7 mm) (5) combination 1/2" - 3/4" and (2) combination 3/4" - 1" (1) combination 1/2" - 3/4" (1) 1 3/4" x 2 3/4" for mounting switches or GFCI (1) combination 1/2" - 3/4" and (1) 3/4" - 1" 1-Year limited NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details. 2. Diagrams above are only two of the many variations this Panel can accommodate. 158 ACCESSORIES For accessories and replacement parts please see page 184-185. Pool & Spa 60 A Control System with Type 3R Load Center T21000R SERIES The T20000R Series load center panels feature an all-weather enclosure and contain a 4 circuit breaker base, an equipment grounding bar and can contain load center only or a heavy duty timer mechanisms. The circuit breaker base accepts interchangeable type breakers made by a number of different manufacturers. Applications · Distribution/Control Panel · Motor Control · Pump Control Features · Four breaker spaces · Accepts PF1000M, P1403ME, P1353ME, P4043ME, P4243ME,T100M or RC2000M Series mechanisms · Accepts many interchangeable type breakers made by a number of different manufacturers · Load center dead front has two knockouts for switches or GFCIs and one on the side · Wiring devices may be installed in these Load Centers with the use of Standoffs, sold separately Model # T21000R T21001R T21004R Mechanism Load Center Only T101M T104M Switch Type SPST DPST Mechanism Supply Voltage 120 VAC, 60 Hz 208-277 VAC, 60 Hz Ratings Load Center Rating Resistive Inductive Tungsten Pilot Duty Motor Operating Temperature Dimensions H x W x D Knockout Dimensions Bottom Left Right Back Warranty 60 A, 120/240 VAC or 120/208 VAC, Single Phase 30 A, 120-240 VAC, 60 Hz 30 A, 120-240 VAC, 60 Hz 30 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz -40°F - 130°F (-40°C - 54°C) 16.875" x 8.875" x 4.75" (428.6 mm x 225.4 mm x 120.7 mm) (5) combination 1/2" - 3/4" and (3) combination 3/4" - 1" (1) combination 1/2" - 3/4" (1) 1 3/4" x 2 3/4" for mounting switches or GFCI (1) combination 1/2" - 3/4" and (1) 3/4" - 1" 1-Year limited WIRING DIAGRAMS Pool & Spa Mechanical Control Centers T21000R T21001R ACCESSORIES For accessories and replacement parts please see page 184-185. NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details. 2. Diagrams above are only two of the many variations this Panel can accommodate. 159 Pool & Spa Pool & Spa Mechanical Control Centers T30004R WIRING DIAGRAMS T30604R Control 2 speed pumps 100 A Control System with Type 3R Load Center T30000R SERIES Can be used as a load center only, or add mechanisms or wiring devices for complete control systems. Applications · Distribution/Control Panel · Motor Control · Pump Control Features · Eight breaker spaces · Reduces installation costs · Eliminates the need for additional service panels · Accepts PF1000M, P1403ME, P1353ME, P4043ME, P4243ME, T100M OR RC2000M Series mechanisms · Control two-speed pumps with the T30604R · Fully compatible with all electrical requirements for pool/spa installations · Load center dead front has two knockouts and one on the side for switches or GFCIs · Wiring devices may be installed in these load centers with the use of Standoffs, sold separately Model # Mechanism Switch Type Mechanism Supply Voltage T30000R5 Load Center Only T30004R (1) T104M DPST 240 VAC, 60 Hz T30404R (2) T104M DPST/DPST 240/240 VAC, 60 Hz T30401R T104M & T101M DPST/SPST 240/120 VAC, 60 Hz T30604R T106M & T104M SPDT/DPST 240/240 VAC, 60 Hz T32404R* T104M201 & T104M DPST/DPST 240/240 VAC, 60 Hz * The heater protection switch is closed when the time switch contacts are open to allow remote operation of heater. A flow or pressure switch must always be part of heater control circuit. Ratings Load Center Rating Resistive Inductive Tungsten Pilot Duty Motor Dimensions H x W x D Operating Temperature Knockouts Bottom Left Right Back Warranty 100 A, 120-240 VAC, Single Phase, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz 16.875" x 10.875" x 4.75" (428.6 mm x 276.2 mm x 120.7 mm) -40°F - 130°F (-40°C - 54° C) (3) 1/2" (4) combination 1/2" - 3/4" and (2) combination 3/4" - 1" (1) combination 3/4" - 1" (1) 1 3/4" x 2 3/4" for mounting switches and GFCI (4) 1/2" and (3) combination 1/2" - 3/4" 1-Year limited NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details. 2. Diagrams above are only two of the many variations this Panel can accommodate. 160 ACCESSORIES For accessories and replacement parts please see page 184-185. Pool & Spa 125 A Control System with Type 3R Load Center T40000R SERIES Can be used as a Load Center only, or add mechanisms or wiring devices for complete control systems. Applications · Distribution/Control Panel Features · Eight breaker spaces · Reduces installation costs · All-in-one electrical load center eliminates the need for additional service panels · Accepts any combination of PF1000M Series, P1403ME, P1353ME, P4043ME, P4243ME, T100M Series or RC2000M Series mechanisms · Fully compatible with all electrical requirements for pool/spa installations · Load center dead front has four knockouts for switches or GFCIs (Note: T40000R4 has one knockout) · Wiring devices may be installed in these Load Centers with the use of Standoffs, sold separately Model # T40004R T40404R T40000R4 Mechanism(s) Switch Type Mechanism Supply Voltage (1) T104M DPST 240 VAC, 60 Hz (2) T104M DPST 240 VAC, 60 Hz Load Center with Compartment for Optional Wiring Devices Ratings Load Center Rating Resistive Inductive Tungsten Pilot Duty Motor Operating Temperature Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Right Back Warranty 125 A MAX, 120-240 VAC, Single Phase, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 40 A, 120-240 VAC, 60 Hz 1000 VA, 120-240 VAC, 60 Hz 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz -40°F - 130°F (-40°C - 54°C) 20.875" x 12.875" x 4.75" (530.2 mm x 327 mm x 120.7 mm) (5) 1/2" - 3/4", (4) 1/2", (2) 3/4" - 1", 1 1/4" (2) 1/2" - 3/4" (1) 1 3/4" x 2 3/4" for mounting switches and GFCI (4) 1/2" - 3/4", (2) 3/4" - 1" 1-Year limited WIRING DIAGRAMS Pool & Spa Mechanical Control Centers T40004R ACCESSORIES For accessories and replacement parts please see page 184-185. NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details. 2. Diagrams above are only two of the many variations this Panel can accommodate. 161 Pool & Spa Mechanical Control Centers Pool & Spa Protect Expensive Pool Equipment with the PS3000 SPD + Load Center Even the best laid plans for pool season can be sunk in an instant when an unexpected power surge occurs. Without the right surge protection device in place, transients and voltage surges can damage expensive pool equipment, keeping homeowners out of the water and holding the bill for costly maintenance. But there's a simple way to prevent disaster in the upcoming pool season. Ideal for Retrofits and New Construction Designed for simple installation in a variety of settings, the PS3000 can be quickly wired into pool and spa breaker/ automation panels or existing home electrical service panels for complete protection of all downstream equipment. PS3000 units can also be paired with an Intermatic Load Center for added convenience and functionality. This is typically done in new pool builds, with the Load Center serving as the protecting central hub for connected pool and spa equipment. Load Center PS3000 SPD* + Common PS3000 Applications: · Pool and spa LED lighting · Gas and electric high-efficiency heaters · Single and variable speed pool pumps · Pool automation systems · Water feature pumps · Chlorinators · Suction cleaners · Stereo and speaker systems · Portable hot tubs * See page 181 for product information 162 Pool & Spa Mechanical Control Centers Pool & Spa Control System with Transformer and Power or Load Center MECHANICAL CONTROLS These mechanical control systems include built-in transformers for ease of installation. Applications · Distribution/Control Panel · Landscape Lighting · Motor Control · Pump Control · Underwater Lighting Features · All-in-one control power for pool/spa installation · Easy to wire · Can house additional Intermatic mechanisms and components · Control two-speed pumps with the T40604RT3 · Heavy-duty Type 3R metal indoor/outdoor power and load center · Wiring devices may be installed in these Load Centers with the use of Standoffs, sold separately · Knockout on the side for additional wiring device Model # Description Power Center T10004RT1 Control Panel with 100 W Transformer and T104M Mechanism T10004RT3 Control Panel with 300 W Transformer and T104M Mechanism Load Center with Eight Breaker Spaces T40000RT3 100 A Load Center Only with 300 W Transformer, 8-Breaker Spaces T40003RT3 100 A Load Center with 300 W Transformer and T103M Mechanism, 8-Breaker Spaces T40004RT1 100 A Load Center with 100 W Transformer and T104M Mechanism, 8-Breaker Spaces T40004RT3 100 A Load Center with 300 W Transformer and T104M Mechanism, 8-Breaker Spaces T40604RT3 100 A Load Center with 300 W Transformer and T104M & T106M Mechanisms, 8-Breaker Spaces Mechanism Supply Voltage 240 VAC, 60 Hz 240 VAC, 60 Hz 120 VAC, 60 Hz 240 VAC, 60 Hz 240 VAC, 60 Hz 240 VAC, 60 Hz Watts 100 300 300 300 100 300 300 Transformer Input Voltage Output Voltage 1 A, 120 VAC, 60 Hz 3 A, 120 VAC, 60 Hz 12, 13, 14 VAC 12, 13, 14 VAC 3 A, 120 VAC, 12, 13, 14 VAC 60 Hz 1 A, 120 VAC, 12, 13, 14 VAC 60 Hz 3 A, 120 VAC, 12, 13, 14 VAC 60 Hz 3 A, 120 VAC, 12, 13, 14 VAC 60 Hz T10004RT1 T40000RT3 WIRING DIAGRAMS Ratings Power Center Rating 120-240 VAC, 60 Hz single-phase Load Center Rating 100 A, 120-240 VAC, Single Phase, 60 Hz Switch Type T40604RT3 DPST 1 NO/1 NC, DPST Resistive 40 A, 120-240 VAC, 60 Hz Inductive Ballast 40 A, 120-240 VAC, 60 Hz Tungsten 40 A, 120-240 VAC, 60 Hz Pilot Duty 1000 VA, 120-240 VAC, 60 Hz Motor 2 HP, 24 FLA @ 120 VAC, 60 Hz, 5 HP, 28 FLA @ 240 VAC, 60 Hz Operating Temperature -40°F - 130°F (-40°C - 54°C) Warranty 1-Year limited Dimensions Power Center H x W x D 12.875" x 12.875" x 4.75" (327 mm x 327 mm x 120.7 mm) Load Center H x W x D 20.875" x 12.875" x 4.75" (530.2 mm x 327 mm x 120.7 mm) Knockouts T10000R Series Bottom Left Right Back (5) 7/8" - 1 7/8", (2) 7/8", (2) 1 1/8" - 1 3/8" (1) 7/8" - 1 1/8" (1) 1 3/4" x 2 3/4" for mounting switches and GFCI (1) 7/8" - 1 1/8", (1) 1 1/8" - 1 3/8" Knockouts T40000R Series Bottom Left Right Back (5) 7/8" - 1 7/8", (4) 7/8", (2) 1 1/8" - 1 3/8" - 1 5/8" (2) 7/8" - 1 1/8" (1) 1 3/4" x 2 3/4" for mounting switches and GFCI (4) 7/8" - 1 1/8", (2) 1 1/8" - 1 3/8" ACCESSORIES NOTES: 1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details. 2. Diagrams above are only two of the many variations this Panel can accommodate. For accessories and replacement parts please see page 184-185. 163 Pool & Spa Pool & Spa Load Centers Align Equipment to Pool Needs with a Next Generation Load Center Panel It's no surprise that the average pool setup integrates more technology than the backyards of past generations. From filters and heaters to variable speed pumps and nicheless LED lights, there is more equipment than ever connected to the average pool pad. By combining the most versatile busbar design in the business with built-in safety transformer functionality, new Intermatic load center panels allow professionals to connect multiple pieces of pool equipment and an array of low-voltage underwater lights with ease. Unlike our standard panels, our next-gen panels are timer-less, making them an ideal choice for new construction projects. From the outside, these new solutions blend right in. They feature a familiar dead front design and the same powder coat paint and color utilized in previous pool panel offerings. Our next gen panels are designed for pool only applications that do not require a time clock provision which allows for more internal wiring space. These new panels offer reduced audible noise (in transformer versions) and come with device mounting brackets for switch/GFCI provisions. Updated side knockouts also accommodate larger in-use receptacle weatherproof covers for added convenience. 164 Pool & Spa Pool & Spa Load Centers Next Generation Load Centers Simple solutions for simple pools. Need a solution for a basic pool with a variable speed pump? Look no further than the Intermatic next generation load center. Tackle any pool project with the next generation Intermatic load centers. Designed versatility and ease of installation, these panels are built specifically for pool systems. They're the ideal choice for connecting underwater luminaires and essential pool equipment. Wiring Space Built-in Breaker Base Quiet Transformer and Enclosure Newly designed panel with extended transformer cover minimizes audible noise Knock-out Adjustment Increased low and high voltage knock outs Knock-out Adjustment Exterior GFCI knock-out moved to accommodate WP5000/WP7000 covers Built-in Brackets for Wiring Devices Model Number Description P40000R5 P40000RT1 P40000RT3 125 Amp load center only 100 Amp load center only with 100 Watt transformer 100 Amp load center only with 300 Watt transformer Watts 100 300 Transformer Input Voltage Output Voltage 1 A 120 VAC 60Hz 12, 13, 14 VAC 3 A 120 VAC 60Hz 12, 13, 14 VAC LIKE TO KNOW MORE? Scan the QR code to the right for a variety of helpful resources, including sell sheets, product instructions, installation videos and more. Ratings Load Center Rating P40000R5 P40000RT1 & P40000RT3 125 A, 120-240 VAC 100 A, 120-240 VAC Enclosure Type Outdoor Type 3R Metal Operating Temperature -40°F - 130°F (-40°C - 54°C) Knockouts Bottom Left Right Back (1) 1" - 1-1/4", (2) 3/4" - 1", (6) 1/2" - 3/4" (2) 1/2" - 3/4" (1) 1-3/4" x 2 - 3/4" for mounting switches and GFCI (1) ¾" -1", (2) 1/2" - 3/4" Warranty 1-Year limited 165 Pool & Spa Pool & Spa Transformers PX50 PX100S PX300 PX600S Why Choose PX Series Safety Transformers? Though similar products can share the same basic look and functionality, what's under the surface makes all the difference when it comes to reliability and value. For example, installing high-performance safety transformers can help streamline installations and ensure consistency from one season to the next, whereas an inferior solution can cause delays and maintenance headaches. Intermatic safety transformers, such as the PX100, PX300 and COMBOConnect® Junction Box Transformer, are manufactured in an ISO-certified facility that includes more than 40 on-site specialty engineers and offer unique features that help them stand out in a crowded field. Designed for High-Performance, Built to Last Super Quiet Stainless Steel Non-magnetic Stainless steel reduces audible hum in low-voltage lighting applications Automatic Breaker Reset Built-in circuit protection will disconnect power to the transformer in case of defect or overload PX100S Premium Construction Manufactured in an ISO-certified facility that includes more than 40 on-site specialty engineers New Built-in Noise Filter Reduces electronic noise and interference when used in low-voltage lighting applications Wiring Flexibility Extra space within the enclosure simplifies installations Safety Transformers PX SERIES These safety transformers are specifically designed to supply 12-14 VAC and are suitable for direct connection to underwater pool/spa lights. A grounded shield between the primary and secondary winding assures safe operation. Built-in circuit protection will disconnect power to the transformer in case of an overload. Applications · Landscape Lighting · Underwater Lighting Features · Mounting brackets on the top and bottom · Built-in circuit protection disconnects power temporarily in case of overload* · Complies with NEC Code 680.23 requirements for underwater luminaries · Built in Noise filter reduces electronic noise and interference in low-voltage lighting applications · Stainless steel options for quiet audible sound levels. Model # Input Voltage Output Voltages Watts 3R Beige Metal PX50 .5 A, 120 VAC, 60 Hz 50 W PX100 1 A, 120 VAC, 60 Hz 100 W PX300 3 A, 120 VAC, 60 Hz 300 W PX600 6 A, 120 VAC, 60 Hz 600 W 3R Stainless Steel 12 VAC, 13 VAC, 14 VAC PX50S .5 A, 120 VAC, 60 Hz 50 W PX100S 1 A, 120 VAC, 60 Hz 100 W PX300S 3 A, 120 VAC, 60 Hz 300 W PX600S 6 A, 120 VAC, 60 Hz 600 W *Disconnection is not permanent; the transformer is equipped with a thermal protector. The circuit will "re-energize" when the transformer cools. Ratings PX50, 100, 300 Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Right Back Warranty 7.25" x 5.25" x 4.5" (184.2 mm x 133 mm x 114.3 mm) (4) combination 1/2" - 3/4" (2) combination 1/2" - 3/4" (2) combination 1/2" - 3/4" (2) combination 1/2" - 3/4" 1-Year limited Ratings PX600 (PX600S) Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Right Back Warranty 10" x 10" x 5.375" (254 mm x 254 mm x 136.5 mm) (2) combination 1/2" - 3/4", (4) combination 3/4" - 1" (2) combination 1/2" - 3/4" (2) combination 1/2" - 3/4" (2) combination 1/2" - 3/4" 1-Year limited 166 Pool & Spa Junction Boxes Pool & Spa PJBX52100 PJB2175 PJB4175 COMBOConnect® PJBX52100 The COMBOConnect® solution combines the simplicity of a standard connection box with the power of a low-voltage transformer of 100 W. Applications · Landscape Lighting · Underwater Lighting Features · Patented design that combines a standard junction box with a built-in transformer · Two high-voltage openings (one for inlet power, one to daisy chain to other j-boxes), five low-voltage openings (one more than typical larger junction boxes to better accommodate nicheless lights) · Includes built-in 100 W safety transformer;Built-in electronic noise reduction · Unit is 20 percent smaller than standard junction box and transformer components · Connections are designed to be easily accessible · Uses insulated terminals for wiring connections · Mount via wall, post or rod (PA119 mounting bracket sold separately.) · Complies with NEC Code 680.24 requirements for junction boxes and per NEC 411 for low-voltage landscape lighting · 1-year warranty Model Number PJBX52100 Light Connections 5 Mounting Options Bracket, Post, Rod, Wall Dimensions H x W x D 5" x 8" x 6" (127 mm x 203.2 mm x 152.4 mm) WIRING LOCATIONS 120 VAC Input for 13 VAC Output 120 VAC Input for 12 VAC Output 120 V Neutral IN (A) 120 V IN (B) Alt. connections for 13 VAC output Noise Filter Low Voltage Output Transformer Move lter line here for 13 VAC Output Low Voltage Output 12 or 13 VAC Output Pool/Spa Light Junction Boxes PJB SERIES These polymeric junction boxes are code compliant and provide safe, reliable connections for low-voltage lights. Specially designed for pools, pool-spa combinations, and landscape applications. Junction boxes are for outdoor use only. Applications · Landscape Lighting · Underwater Lighting Features · Accommodates flexible cords and non-metallic conduits from ½" to 1" · Watertight, multi-fixture enclosure · Easy access ground bar · PA114 Wall/Post Mounting Bracket (sold separately) · Complies with NEC Code 680.24 requirements for junction boxes · 1-year warranty Model Light Mounting Options Number Connections PJB2175 2 PJB4175 4 Bracket, Post, Rod, Wall Dimensions H x W x D 7.25" x 3" x 4" (184.2 mm x 76.2 mm x 101.6 mm) 8.75" x 5" x 4.625" (222.3 mm x 127 mm x 117.5 mm) INSTALLATION PJB2175 & PJB4175 TOP FACE OF JUNCTION BOX BASE NOT LESS THAN 4FT. JUNCTION BOX NOT LESS THAN 8" NOT LESS THAN 4" DECK PLUGS ACCESSORIES For accessories and replacement parts please see page 184-185. 167 Pool & Spa Pool & Spa Electronic Controls PE103 P1403ME 2-SPEED PUMP WIRING DIAGRAMS Electronic Pump Motor Controller with Seasonal Adjustment PE103 Control 1 or 2 speed pumps and 1 auxiliary load with this 3-circuit programmable device. The seasonal adjustment feature can be programmed to automatically adjust filter pump ON/OFF schedules according to the season. Application · Motor Control · Pump Control Features · Saves up to 40% in monthly utility bills compared to standard timers · Meets most rebate incentives · Enables separate daily schedules · Easy-to-follow on-screen setup for programming · DST adjustment included · Auto-voltage adjust · Efficient low-speed operation for all seasons · User programmable high and low-speed events · 100+ hour supercapacitor memory retention · Available with Type 3R indoor/outdoor lockable metal enclosure Model # PE103 P1403ME Description Electronic Pump Motor Controller with Seasonal Adjustment, 4-Circuit, Type 3R Metal Enclosure Electronic Pump Motor Controller with Seasonal Adjustment, 4-Circuit, Mechanism Only 20 TITLE COMPLIANT Ratings Input Voltage Max ON/OFF Operations Number Of Circuits Max Power Consumption Switch Type Resistive Inductive Tungsten Motor Warranty 120-277 VAC, 50/60 Hz 3 3 7 W 4-SPST 30 A @ 24 VAC, 120-277 VAC, 50/60 Hz; 20 A @ 28 VDC 30 A @ 24 VAC, 120-277 VAC, 50/60 Hz 5 A @ 120-277 VAC, 50/60 Hz 16 FLA, 96 LRA @ 120 VAC, 50/60 Hz; 17 FLA, 80 LRA @ 240 VAC, 50/60 Hz 1-Year limited SINGLE SPEED PUMP WIRING DIAGRAMS 168 Digital 3-Circuit Time Switch P153 SERIES This multipurpose 24-hour control is capable of automatically switching loads according to a preset daily schedule. Controls single- and two-speed pumps and cleaner/booster pumps. Three ON/OFF events per circuit per day. Applications · Motor Control · Pump Control Protection Features · Controls single- and two-speed pumps and cleaner/booster pumps · Three ON/OFF events per circuit per day · Seven preprogrammed modes, see chart below for details · Freeze and heater protection · LCD readout · Multivoltage input and output · Countdown and override features enable programs to be overridden and automatically resumed without requiring the user to reprogram the system Model # Description P1353ME 24-Hour Time Control, 3-Circuit, Mechanism Only PE153 24-Hour Electronic Time Control, 3-Circuit, Type 3R Metal Enclosure PE153F 24-Hour Electronic Time Control, 3-Circuit, Freeze Protection Probe,Type 3R Metal Enclosure PE153P 24-Hour Electronic Time Control, 3-Circuit, Type 3R Plastic Enclosure PE153PF 24-Hour Electronic Time Control, 3-Circuit, Freeze Protection Probe,Type 3R Plastic Enclosure Ratings Input Voltage Switch Type Resistive Tungsten Motor Warranty 120/240 VAC, 50/60 Hz 3-SPST 17 A, 120/240 VAC, 50/60 Hz 5 A, 120/240 VAC, 50/60 Hz 80 LRA @ 120/240 VAC, 50/60 Hz; 17 FLA @ 120/240 VAC, 50/60 Hz 1-Year limited 7 PREPROGRAMMED MODES Mode # Switches Control Additional Comments 1 Aux 1, Aux 2, Aux 3 -- 2 Pump High, Pump Low, 2-speed pump timing and protection Aux 3 3 Pump, Aux 2, Filter/cleaner pump timing and protection Booster/Cleaner Pump 4 Pump High, Pump Low, 2-speed and filter/cleaner pump timing and Booster/Cleaner Pump protection 5 Pump L1, Pump L2, Aux 3 1st and 2nd switch controls a 240 VAC pump, where L1 and L2 are disconnected when the pump is OFF 6 Aux 1, Aux 2, Aux 3 Identical to Mode 1, with capability to run a heater Heater green mode when the filter pump is manually turned ON only This mode is ideal for connecting Circuit 1 to a circulation pump in a spa * 7 Pump High, Pump Low, Identical to Mode 2, with the capability to break Common Hot Leg both hot lines of a 240 VAC two-speed pump connection * When spa is not in use, the clock does not turn the heater ON. When spa is in use, the heater can be activated by manually switching Circuit 1 ON Pool & Spa Electronic Controls PE153 PE153PF P1353ME ACCESSORIES For accessories and replacement parts please see page 184-185. 169 Pool & Spa Pool & Spa Electronic Control Centers Pool & Spa PE20000 PE25300F 60 A Pool/Spa Control System with Type 3R Load Center PE20000 SERIES This system can be used as a load center only, or add mechanisms or wiring devices for complete control systems. Applications · Distribution/Control Panel Features · Four breaker spaces · 3-SPST mechanism (P1353ME) controls single- and two-speed filter pumps, cleaner/ booster pumps and pool/spa landscape lighting · Includes low voltage wiring compartment. · Load center dead front has two knockouts for switches or GFCIs · Wiring devices may be installed in these load centers with the use of Standoffs, sold separately · Also compatible with T100 Series Model Number PE20000 PE25300F PE25300 Description 60 A Load Center 60 A Load Center with P1353ME Mechanism and Freeze Protection Probe 60 A Load Center with P1353ME Mechanism PE30000 PE35300 80 A Pool/Spa Control System with Type 3R Load Center PE30000 SERIES This system can be used as a load center only, or add mechanisms or wiring devices for complete control systems. Applications · Distribution/Control Panel Features · Eight breaker spaces · 3-SPST mechanism (P1353ME) controls single and two-speed filter pumps, cleaner/ booster pumps and pool/spa landscape lighting · Includes low voltage wiring compartment. · Load center dead front has four knockouts for switches or GFCIs · Transformer option provides low-voltage for LED lights · Wiring devices may be installed in these load centers with the use of Standoffs, sold separately · Also compatible with T100 Series Model Number PE30000 PE30000T3 PE35300 Description 80 A Load Center 80 A Load Center with 300 W Transformer 80 A Load Center with P1353ME Mechanism Ratings Input Voltage Switch Type Resistive Tungsten Motor Auxiliary Switch Enclosure Dimensions H x W x D Knockout Dimensions Warranty 120/240 VAC, 50/60 Hz 3-SPST 17 A, 120/240 VAC, 50/60 Hz 5 A, 120/240 VAC, 50/60 Hz 80 LRA @ 120/240 VAC, 50/60 Hz; 17 FLA @ 120/240 VAC, 50/60 Hz 2 A, 24 VAC 16.875" x 10.875" x 4.75" (428.6 mm x 276.2 mm x 120.7 mm) See PE3000 Series Ratings 1-Year limited Ratings Input Voltage Switch Type Resistive Tungsten Motor Auxiliary Switch Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Right Back Warranty 120/240 VAC, 50/60 Hz 3-SPST 17 A, 120/240 VAC, 50/60 Hz 5 A, 120/240 VAC, 50/60 Hz 80 LRA, 17 FLA @ 120/240 VAC, 50/60 Hz 2 A, 24 VAC 22.875" x 14.875" x 4.75" (581 mm x 377.8 mm x 120.7 mm) (1) 1 1/8" diameter hole, (6) 1/2" - 3/4", (3) 3/4" - 1" (2) 1/2" - 3/4" (1) 1 3/4" x 2 3/4" (1) 3/4" - 1" 1-Year limited ACCESSORIES For accessories and replacement parts please see page 184-185. 170 Pool & Spa Electronic Control Centers Pool & Spa Remotely Operated Control System RC2163BFE POOL/SPA COMBINATION CONTROL PANEL This system controls Pool / Spa valve rotation, heater, single speed pump, and 120V blowers. Applications · Heater Thermostat Control · Motor Control · Pump Control Features · Eight breaker spaces · Use spring wound timer, toggle switch, wireless receiver/transmitter to operate equipment · 3-Wire heater control · (2) PE24VA 24-V valve actuators included · Heavy-duty Type 3R metal indoor/outdoor load center Model Number Description RC2163BFE Pool/Spa Remotely Operated Combination Control System Note: Remote switch not included. MEMORY HOLD-UP BATTERY TIMER NEUT. LINE 120 VOLT PC BOARD RC2163BFE 120 VOLT SENSOR CONTROL SUPPLY BLK WHT ORG SW24ITVCH* NEUT. WHITE Ratings Load Center Rating Input Voltage Motor Load Ratings Single Speed 100 A, 120/240 VAC or 120/208 VAC, Single Phase, 60 Hz 120/240 VAC, 60 Hz 1 1/2 HP @ 120 VAC, 3 HP @ 240 VAC, 60 Hz SW1 24 VOLT PC BOARD TRA12N0S/2F4OVR. MER 24 V SENSOR SENSOR RELAY BRN BRN 120 SUP TRANS No. of Actuator Connections Dimensions H x W x D Warranty WIRING DIAGRAM TIMER MEMORY HOLD-UP BATTERY MEMORY HOLD-UP BATTERY NEUT. TILMIENRE NEUT. LINE 3 (simultaneous rotation) 16.875" x 10.875" x 4.75" (428.6 mm x 276.2 mm x 120.7 mm) 1-Year limited TIMER MEMORY HOLD-UP BATTERY NEUT. LINE HEATER SELECTOR SW1I2T0CVHOLT PC BOARD BLK WHT ORG CONTROL SUPPLY 120 VOLT SENSOR 120 VOLT PC BOARD24 VOLT 120 VOLT PC BOARD PC BOARD S W 11S2E0NVSOOLRT CONTROL SUPPLY BLK * WHT ORG TRA12N0S/RL1D2F242OOEEV04RMCV.VMIAOVCESTTERWEE*DITCHING SWITCH SW24ITVCH* 24 V SENSOR 24 V A C LINE 2 LOAD 2 LOAD 1 LINE 1 120 VOLT SENSOR CONTROL SUPPLY BLK WHT ORG REMOTE LOCATED 1D2E0VVICSEPW*UITMCPHRINEGLAY STEP 120V Pump - Connect NEUTRAL to WHITE lead and pump NEUTRAL. Connect 120V. line to BLACK lead and BLUE lead to pump LOAD terminal. Cap RED and YELLOW lSeaW2d4sIT. VCH* 240V. SUPPLY/LOAD CONNECTIONS NEUT. WHITE LINE BLACK REMOTE LOCATED 1D2E0VVICSEW*ITCHING SENSOR RELAY Single Thermostat Heater BRN BRN 120V. SUPPLY 120 SUP *Use eith sensor c other line Dual T NEUT. WHITE LINE BLACK 24 V SENSONREUT. WHITE LINE BLACK TRANS 24 VOLT PCP2CB4BOVOOAALRRTDD HEATER HEASSTEWELITRECCHTOR SELECTOR SWITCH STEP TRANS STEP TRANS SW1 SW1 TRA12N0S/2F4TOVRR. MA1E2NR0S/2F4OVR. MER HEATER SELECTOR 24 V A C SENSOR RELAY BRN SENSOR RELAY BRN BRN 120V. BRN SUPPLY 120V. SUPPLY 24 V SENSOR STEP PUMP RELAY 120V Pump - Connect NEUTRAL to WHITE lead and pump NEUTRAL. 1. Connect two 18 gauge wires in SSEwRitIEchSews.itBWhRLEHHKDeTater's Selector 2. CttBeeEorrTnmmWnSii1UnneE2caaPEt0llNPV""oLCLT.nY""Ee. RaINonMfSdItTNRLRRhtAhAOeEAELeLLMCCwDSoAEiIOJrtOUehITTVsMeEEErtPDotREoR LINE 2 LOAD 2 LOAD 1 LINE 1 SWITCH Connect 120V. line to BLACK lead and BLUE lead to pump LOAD terminal. Cap RED and YELLOW leads. 24 V A C 24 V A C BLK WHT RED BLK WHT LINE 2 LOAD 2 LOAD 1 LINE 1 LINE 2 LOAD 2 LOAD 1 LINE 1 Single Thermostat Heater Dual Thermostat Heater * 1CC2oanp01CCnVRe2oaEPcnp0tDun1VmRa2enpE0PcdVtD-uY.C1mlEiaon2LnnpeL0ndOtVeo-WcY.BtClENLlioenLAEaneCULdnsKTOte.oRWlceABtaLSdNLletaoAEiannWCUddgsKTHB.RILlTleUeAEEaLleTdleatadhaodnaeWtdnordHpBmupILmuTUmoEpEpsLlPeONlteaAEUaadUDMtdTatRePtHnrAomdLRepi.nEupaamluL.tmAeppYrLPCSONUOAEUPNUDP2MNTL4EtY0ReCP/VrLAT.mOILORAi.NnDEaSlL. A*soeYtUhnsesSerSoU1eUlriinP2tPche0P2Po(eVsLn4Lr).YnY.0the/VecL.t1Oio2nA0RLRR.VDIOEAEnosrMCCDutlAEhIOaOetITeTVs2EE(4eEUcVDnaRspsreeS)omt1eUrhoie2tPtche0PoeVnLr.nYtRheecEt1iDo2n0RLRR.VIOEAEnosrMCCDutlAEhIOaOetITeTV2EE(4EcVDaRpre) mthoete 240V. SUPPLY/LOAD CONNECTIONS 3. "L*sLeeU"nassAveoeNerihDtcheoe"anHrtnte"herec.st1iwo2n0it.VcInhosruintlhOaetNe2(4pcVoapsre)itmtihooente. other line(s). DuCaOl NTNhEeCrTmIOoNSstatoHtheeraltineer(s). Single Thermostat Heater 1. Conne PARAL Switch 2. Conne (Comm termin Low to 3. Leave h Dual Thermostat Heater 1. Connect two 18 gauge wires in SERIES with Heater's Selector Switches. 1. Connect two 18 gauge wires in 2. Connect one of the wires to SERIES with Heater's Selector Switches. 2. Connect one of the wires to terminal "C" and the other to 1. Connect three 18 gauge wirteesrimn inal "C" and the other to PARALLEL Switches. with Heater's Selteectromr inal "L". INSTALL JUMPER 2. Connect the wire from centBraEl TpoWstEEN TERMINALS terminal "L". INSTALL JUMPER (Common) of heater switch"tLo" AND "H" . BETWEE1N. TCEoRMnnINeAcLtStwo 18 gauge wires in "L" AND "HS"E.RIES with Heater's Selector terminal "C", Low to "L". High to1"H. "3Ca.onLdnenaevcet thheraeteer18swgiatcuhgeinOwNirepsoisnition. 3. Leave heatSewr siwtcithcheisn.ON position. 3. Leave heater switch inOFFPpAoRsiAtioLnL.EL with Heater's Selector 2. Connect one of the wires to Switches. terminal "C" and the other to 2. Connect the wire from central post terminal "L". INSTALL JUMPER (Common) of heater switch to BETWEEN TERMINALS terminal "C", High to "H" and "L" AND "H" . Low to "L". 3. Leave heater switch inON position. 3. Leave heater switch inOFF position. 1. Connect three 18 gauge wires in PARALLEL with Heater's Selector Switches. 2. Connect the wire from central post (Common) of heater switch to terminal "C", High to "H" and Low to "L". 3. Leave heater switch inOFF position. 171 Pool & Spa Wireless Electronic Controls Pool & Spa PE653RC MultiWave® Basic Control System PE653RC The MultiWave® Basic Control System is a wireless electronic controller for pool and spa automation. It includes a five-circuit receiver with a built-in 24-hour timer as well as a wireless remote with batteries. The system also offers air and water sensors, an antenna relocation cap and a mounting base for easy installation. Utilize this solution to retrofit existing mechanical timers or as part of a new construction project. Intermatic's wireless pool and spa controls utilize Z-waveTM technology for wireless transmission. APPLICATIONS · Heater Thermostat Control · Motor Control · Pump Control FEATURES · Controls 5 circuits · Single or two speed pumps; Pentair VSP; heater control, blowers, lights, cleaners · 24-hour timing with 3 ON/OFF events per circuit ·Includes receiver, wireless remote, water and air temperature sensors, (3) AA batteries, equipment labels, flathead screwdriver, raintight enclosure, raintight cap and mount for remote mounting antenna · Type 3R metal indoor/outdoor enclosure · See MultiWave ECS and ECS Plus Systems for additional control options Model # PE653RC Description 24-Hour MultiWave® Basic Control , 5-Circuit, Type 3R Metal Enclosure 20TITLE COMPLIANT FLORIDA ENERGY EFFICIENCY CODE Ratings Max Power Consumption Input Voltage Circuit 1 Resistive Motor Tungsten Circuit 2-5 Resistive Motor Tungsten Enclosure Dimensions H x W x D Knockouts Bottom Left Back Right Warranty 5 W 120-240 VAC 50/60 Hz 20 A, 120 VAC, 20 A, 240 VAC 80 LRA @120/240 VAC; 17 FLA @120/240 VAC 5 A 15 A 60 LRA @120/240 VAC; 10 FLA @120/240 VAC 5 A 9.375" x 5.5" x 3.75" (238.1 mm x 139.7 mm x 95.3 mm) (2) combination 1/2" - 3/4" (1) combination 1/2" - 3/4" (1) combination 1/2" - 3/4" (1) combination 1/2" - 3/4" 2-Year limited 172 PE25065RC MultiWave® ECS System PE25065RC This system includes the MultiWave Basic and an Expansion Module to control up to four valve actuators, two heaters, various variable speed pumps and solar heating/cooling. The Remote Switch feature provides simple ON/OFF control of several components (i.e., spa heater, spa blower, spa lights) simultaneously with the flip of a single switch. APPLICATIONS · Heater Thermostat Control · Motor Control · Pump Control FEATURES · Four breaker spaces · Controls 5 circuits ·Controls 4 actuator ports (actuators not included), 2 for pool to spa valve rotation, 1 for water feature valve rotation, and 1 for solar applications · Controls 2 heater circuits · USB port for ease of upgrading firmware ·Load center dead front has two knockouts for switches and GFCIs · Remote switch for simple ON/OFF control of several components at the same time* *Remote switch sold separately Model # PE25065RC Description MultiWave® ECS System with 60 A Load Center, Expansion Module 20TITLE COMPLIANT FLORIDA ENERGY EFFICIENCY CODE Ratings Load Center Rating Input Voltage Circuit 1 Resistive Motor Tungsten Circuit 2-5 Resistive Motor Tungsten Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Back Right Warranty 60 A, 120/240 VAC or 120/208 VAC, Single Phase 120-240 VAC 50/60 Hz 20 A 80 LRA @120/240 VAC; 17 FLA @120/240 VAC 5 A 15 A 60 LRA @120/240 VAC; 10 FLA @120/240 VAC 5 A 16.875" x 10.875" x 4.75" (428.6 mm x 276.2 mm x 120.7 mm) (1) 1 1/8" diameter hole, (6) combination 1/2" - 3/4", (3) combination 3/4" - 1" (2) combination 1/2" - 3/4" (1) combination 3/4" - 1 (1) 1 3/4" x 2 3/4" for mounting switches or GFCI 2-Year limited Pool & Spa Wireless Electronic Controls Pool & Spa PE35065RC MultiWave® ECS Plus System PE35065RC This system includes the MultiWave ECS, two PE24VA Intermatic Valve Actuators and an upgraded 80 A Load Center with 8 breaker base. APPLICATIONS · Heater Thermostat Control · Motor Control · Pump Control FEATURES · Eight breaker spaces · Controls 5 circuits ·C ontrols 4 actuator ports (2 actuators included), 2 for pool to spa valve rotation, 1 for water feature valve rotation and 1 for solar applications · Controls 2 heater circuits · USB port for ease of upgrading firmware · Load center with eight position 80 A breaker base · Load center dead front has four knockouts for switches and GFCIs · Remote switch for simple ON/OFF control of several components at the same time* *Remote switch sold separately Model # PE35065RC Description MultiWave® ECS System with 80 A Load Center, Expansion Module and Two Valve Actuators 20TITLE COMPLIANT FLORIDA ENERGY EFFICIENCY CODE Ratings Load Center Rating 80 A, 120/240 VAC or 120/208 VAC, Single Phase Input Voltage 120-240 VAC 50/60 Hz Circuit 1 Resistive 20 A Motor 80 LRA @120/240 VAC; 17 FLA @120/240 VAC Tungsten 5 A Circuit 2-5 Resistive 15 A Motor 60 LRA @120/240 VAC; 10 FLA @120/240 VAC Tungsten 5 A Enclosure Dimensions 22.875" x 14.875" x 4.75" H x W x D (581 mm x 377.8 mm x 120.7 mm) Knockout Dimensions Bottom Left Back Right Warranty (1) 1 1/8" diameter hole, (6) combination 1/2" - 3/4", (4) 1/2", (2) combination 1 1/8" - 1 3/8" - 1 11/16" (2) combination 1/2" - 3/4" 4) combination 3/4" - 1", (2) combination 3/4" - 1" (1) 1 3/4" x 2 3/4" for mounting switches or GFCI 2-Year limited PE30065RC MultiWave® Basic with 80 A Load Center PE30065RC & PE30065RCT3 A wireless electronic controller for pool or spa automation. Retrofit existing mechanical timers or install with new construction. Has an 80 A load center. APPLICATIONS · Heater Thermostat Control · Motor Control · Pump Control FEATURES · Eight breaker spaces · Controls 5 circuits · Controls pumps, lights, cleaners and heaters · Operates single, two and Pentair® IntelliFlo® and IntelliPro® variable-speed pumps · 24-hour timing with 3 ON/OFF events per circuit ·Includes receiver, wireless remote, water and air temperature sensors, (3) AA batteries, equipment labels, flathead screwdriver, raintight enclosure, raintight cap and mount for remote mounting antenna · See MultiWave ECS and ECS Plus Systems for additional control options · Type 3R indoor/outdoor metal load center · Four knockouts for GFCIs and switches Model # PE30065RC PE30065RCT3 Description 24-Hour MultiWave® Basic Control , 5-Circuit, 80 A Load Center, Type 3R Metal Enclosure 24-Hour MultiWave® Basic Control , 5-Circuit, 80 A Load Center, 300 W Transformer, Type 3R Metal Enclosure 20TITLE COMPLIANT FLORIDA ENERGY EFFICIENCY CODE Ratings Load Center Rating Input Voltage Circuit 1 Resistive Motor Tungsten Circuit 2-5 Resistive Motor Tungsten Transformer Input Voltage Output Voltage Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Back Right Warranty 80 A, 120/240 VAC or 120/208 VAC, Single Phase 120-240 VAC 50/60 Hz 20 A 80 LRA @120/240 VAC; 17 FLA @120/240 VAC 5 A 15 A 60 LRA @120/240 VAC; 10 FLA @120/240 VAC 5 A 120 VAC, 60 Hz 12, 13, 14 VAC 22.875" x 14.875" x 4.75" (581 mm x 377.8 mm x 120.7 mm) (1) 1 1/8" diameter hole, (6) combination 1/2" - 3/4", (4) 1/2", (2) combination 1 1/8" - 1 3/8" - 1 11/16" (2) combination 1/2" - 3/4" (4) 1/2", (2) combination 1 1/8" - 1 3/8" - 1 11/16" (1) 1 3/4" x 2 3/4" for mounting switches or GFCI 2-Year limited 173 Pool & Spa Wireless Add-On Components Pool & Spa PE653 MultiWave® 5-Circuit Wireless Receiver PE653 FEATURES · Ideal addition to an existing enclosure installation · Connects with PA122 water/solar temperature sensor and 178PA28A air sensor · Communicates with pumps, cleaners, heaters and lights · Ideal for upgrading mechanical timers · 2-year warranty 20TITLE COMPLIANT FLORIDA ENERGY EFFICIENCY CODE Model # Description PE653 MultiWave® 5-Circuit Wireless Receiver PE953 MultiWave® Wireless Remote PE953 FEATURES · On-demand control of MultiWave functions and other devices ·Backlit display shows time of day, equipment status, water and air temperatures and ON/OFF schedules · Water-resistant · Includes 3 AA batteries and equipment labels · 2-year warranty Model # PE953 Description Wireless Remote, MultiWave systems PA122 Water/Solar Temperature Sensor PA122 FEATURES · Monitors pool/spa water temperature to control conventional gas or electric heating · Monitors water temperature for solar heating/cooling · 1-year warranty Model # PA122 Description Water/Solar Temperature Sensor, 10k OHM, For MultiWave systems 178PA28A Freeze Probe Kit 178PA28A FEATURES · Monitors outside air temperature · Protects pool/spa equipment and plumbing · Perfect for below-freezing outdoor environments · 1-year warranty Model # 178PA28A Description Freeze Probe Kit, 10k OHM, For MultiWave systems 174 Pool & Spa Valve Actuators Pool & Spa P4043ME PE140 Valve Actuator Controls P4043ME This switching device is most suited for controlling electronic valve actuators which direct the flow of water to water features, fountains, slides, etc. It can also be used with a spring wound timer or simple switch to control fountains or other aquatic features. APPLICATIONS · Valve Control FEATURES ·Easily snaps into most existing Intermatic enclosures with available mechanism support bracket · Controls up to three valve actuators (simultaneous rotation) · Switches heater thermostat HIGH/LOW · Remote control capabilities* *Switch not included Model # P4043ME PE140 Description Valve Actuator Control - Mechanism Only Valve Actuator Control, Type 3R Metal Enclosure PE24VA 24-Volt Valve Actuator PE24VA Designed with quality in mind, Intermatic's 24-Volt valve actuators provide reliable control of 2-way and 3-way diverter valves for pool/spa combinations and water features. The water flow can be altered for specific applications through the adjustable cam, which rotates diverter valves to multiple degree settings. The cam settings can be easily adjusted by simply removing the lid. These valve actuators are compatible with all pool/spa valves currently offered in the industry and will retrofit into all pool/spa control systems. APPLICATIONS · Valve Control FEATURES · Reliable control of 2-way and 3-way diverter valves · Easy-to-adjust cam rotates valves to multiple settings · Compatible with all pool/spa valves and controls Model # PE24VA Description 24-Volt Valve Actuator Ratings Input Voltage Valve Actuator Supply Warranty 120/240 VAC, 50/60 Hz 24 VAC, 40 VA 1-Year limited PE24GVA Ratings Valve Actuator Supply Amp Cord Length Warranty 24 VAC, 60 Hz 0.75 A 25 ft 1-Year limited Ratings Valve Actuator Supply Amp Cord Length Warranty 24 VAC, 60 Hz 0.75 A 25 ft 1-Year limited Next Gen 24-Volt Valve Actuator PE24GVA The Intermatic® PE24GVA valve actuator is designed for today's pool automation systems. It is fully adjustable with a simplified tool-less setup. This valve actuator was designed specifically with the installers and pool owners in mind. The spin and set cams make it a breeze to work with. These valve actuators are compatible with all pool/spa valves currently offered in the industry and will retrofit into all pool/spa control systems. APPLICATIONS · Valve Control FEATURES · Reliable control of 2-way and 3-way diverter valves · Easy-to-adjust cam rotates valves to multiple settings · Compatible with all pool/spa valves and controls Model # PE24GVA Description 24-Volt Valve Actuator 175 Pool & Spa Pool & Spa Freeze Protection PF1112T PF1222TB1 Ratings Power Center Rating Load Center Rating Operating Voltage Switch Type Resistive Motor Thermostat Range Power Center Dimensions H x W x D Load Center Dimensions H x W x D Warranty 120/240 VAC, 60 Hz, Single-Phase 60 A Max, 120-240 VAC, Single Phase 60 Hz 240 VAC, 60 Hz DPST 17 A, 240 VAC, 60 Hz 3 HP, 240 VAC, 60 Hz 33°F - 42°F (0.5°C - 5.6°C) 12" x 12.875" x 4.25" (304.8 mm x 327 mm x 108 mm) 16.875" x 10.875" x 4.75" (428.6 mm x 276.2 mm x 120.7 mm) 1-Year limited PF1102M PF1102T Ratings Operating Voltage PF1102 PF1103 HP PF1102 PF1103 Thermostat Range Enclosure Dimensions H x W x D Knockout Dimensions Bottom Left Back Right Warranty 240 VAC, 60 Hz 120-240 VAC, 60 Hz 3 HP @ 240 VAC, 60 Hz 1 1/2 HP @ 120 VAC, 3 HP @ 240 VAC, 60 Hz 33°F - 42°F (0.5°C - 5.6°C 9.625" x 5.75" x 3.625" (244.5 mm x 146.1 mm x 92.1 mm) (2) 1/2" - 3/4" (1) 1/2" - 3/4" (4) 1/2" - 3/4", (1) 1/2" - 3/4" (1) 1/2" - 3/4" 1-Year limited 176 Control System with Freeze Protection and Power or Load Center PF1100 & PF1200 SERIES MECHANICAL PANELS Protects pool/spa equipment against freeze damage. APPLICATIONS · Protection · Pump Control FEATURES · GFCI and switch mounting capabilities ·Turns pump and heater ON when outdoor temperature drops below user-adjust- able setpoint on thermostat · Heavy-duty Type 3R metal indoor/outdoor enclosure Model # Description Heater Protection PF1112T Freeze Protection Control Center with Timer No and Thermostat for 240V Applications, Type 3R Metal Enclosure PF1202T Freeze Protection Control Center with 2 Timers No and Thermostat for 240V Cleaner Applications, Type 3R Metal Enclosure PF1222TB1* Freeze Protection 4/8 Breaker Base Panel with Yes 2 Timers and Thermostat for 240V Cleaner Applications, Heater Protection, Type 3R Metal Enclosure *Four breaker spaces and heater protection Note: Wiring devices may be installed in these Load Centers with the use of Standoffs. Single-Circuit Freeze Protection Controls PF1100 MECHANICAL SERIES Protects pool/spa equipment against freeze damage. Turns pump and heater on when the outdoor temperature drops. Integrated adjustable thermostat. APPLICATIONS · Protection · Pump Control FEATURES · T urn pump and heater ON when outdoor temperature drops below user-adjustable setpoint on thermostat · Models with or without mechanical timer mechanism · Heavy-duty metallic rainproof enclosure · For use with pool and spa, pond, fountain or marina type applications Model # Description PF1102M* Freeze Protection Thermostat only for 240V Applications, Mechanism PF1102 Freeze Protection Thermostat only for 240V Applications, Type 3R Metal Enclosure PF1103 Freeze Protection Thermostat only for 120/240V Applications, Type 3R Metal Enclosure PF1102MT Freeze Protection Timer with Thermostat for 240V Applications, Mechanism PF1103MT* Freeze Protection Timer with Thermostat for 120/240V Applications, Mechanism PF1102T Freeze Protection Timer with Thermostat for 240V Applications, Type 3R Metal Enclosure PF1103T Freeze Protection Timer with Thermostat for 120/240V Applications, Type 3R Metal Enclosure *Neutral must be installed Pool & Spa Pool & Spa Remote Controls Outdoor Radio Receivers RC600 SERIES Control loads with the receiver mounted ON/OFF button or wirelessly via a remote transmitter. For indoor/outdoor use. Turn your pool lights on from any spot around your house. APPLICATIONS · Motor Control · Pump Control · Lighting FEATURES · Respond to handheld transmitter (provided separately below) · For indoor/outdoor use · Handle a variety of switching applications · Enable connected loads to be turned ON/OFF remotely · Maximum range 100 ft · Beige outdoor grade plastic enclosure Model # RC613 RC613L RC613R Description Radio Receiver with manual ON/OFF button Radio Receiver with manual ON/OFF button -- (3) 36" Long Leads Heavy-Duty Receiver Module with Manual ON/OFF button RC613R RC613 Ratings RC613/RC613L Switch Type Resistive Tungsten Motor RC613R Switch Type Resistive Tungsten Motor Enclosure H x W x D RC613/RC613L RC613R Warranty SPST 20 A, 120 VAC, 60 Hz 10 A, 1200 W, 60 Hz 1 HP, 120 VAC, 60 Hz DPST 30 A, 120/240 VAC, 60 Hz 12.5 A, 1500 W, 60 Hz 1 1/2 HP @ 120 VAC, 3 HP @ 240 VAC, 60 Hz 4.5" x 3" x 1.75" (114.3 mm x 76.2 mm x 44.5 mm) 8" x 4.25" x 3.375" (203.2 mm x 108 mm x 85.7 mm) 1-Year limited Handheld 3-Channel Radio Transmitter RC939 Transmit signals to the RC family of radio receivers for remote ON/OFF control. Controls shared pool/spa equipment including booster pump. Operates up to three RC600 series receivers. APPLICATIONS · Motor Control · Pump Control · Lighting FEATURES · Operates up to three RC600 Series receivers · Range 100 ft. · Replaceable battery RC939 Model # Description Range Battery RC939 Handheld 3-Channel Radio 100 ft* Transmitter CR2032 *Range depends on many factors including age of battery, proximity of large metal objects, location of receiver, and environmental conditions at the time of transmission. Ratings Dimensions H x W x D Warranty 2.5" x 1.25" x 1/2" (63.5 mm x 31.8 mm x 12.7 mm) 1-Year limited ACCESSORIES For accessories and replacement parts please see pages 184-185. 177 Pool & Spa Pool & Spa Air Switch RC2343PT Ratings Input Voltage 120-240 VAC, 60 Hz Switch Type 4-Function Switch Ratings (Each Circuit) Resistive 20 A, 120/240 VAC, 60 Hz Motor 1 HP, 120 VAC, 60 Hz, 2 HP, 240 VAC, 60 Hz Enclosure H x W x D 9 5/8" x 5 3/4" x 3 5/8" (244.5 mm x 146.1 mm x 92.1 mm) Warranty 1-Year limited Multifunction Air Switches with 24-Hour Timer RC2000 SERIES Control ON/OFF timing safely, without electricity, near the water. APPLICATIONS ·Pump Control · Motor Control FEATURES · Remote control for one or two separate loads · Multiple ON/OFF settings per day · Flexible air hose (RC117 sold separately) enables operation up to 100 feet · Type 3R plastic indoor/outdoor enclosure · Requires a neutral Model # RC2343PT Description One or Two Speed Pump and Blower OM/OFF with Timer RC4G RC117 RC127B RC510 Air Switches and Accessories RC SERIES Used for air controlled equipment APPLICATIONS · Motor Control · Pump Control FEATURES · Replaces existing buttons and accessories Model # RC4G RC6F RC117 RC127B RC150 RC510 Description 1" Gunite Air Button - 100 ft Range 1 1/2" Fiberglass Air Button - 100 ft Range Air Tubing - 75 ft Length Air Tubing and Air Button (RC4G) - 75 ft Length Air Tubing - 500 ft Length Air Tubing Coupler (pack of 10) ACCESSORIES For additional accessories and replacement parts please see page 184-185. 178 Pool & Spa Panel Mount Timers Pool & Spa PB873MKZ Panel Mount Timers PB SERIES PB913N/PB914N PB913N66/PB914N66 PB913N84/ PB914N84 These timers provide automatic control for pumps, cleaners and other types of loads. Timers have three-way mounting; flush in round opening, raised in rectangular opening or on base. Quick connect terminals for easy installation. APPLICATIONS · Motor Control · Pump Control FEATURES · Automated control for pumps, cleaners and other types of loads · 3 different mounting methods · Quick connect terminals for easy installation · 24-hour timing cycle - MIN ON time 1-hr, MAX ON time 23-hr, 30-min intervals · 7-day timing cycle - 6 to 162-hr ON time, 3-hr intervals Model # Description Input Voltage No. of Trippers Without Manual Override PB873MKZ 7-Day 120V Mechanical Panel 120 VAC, 60 Hz 56 Mount Timer, 56 Trippers PB913N 24-Hour 120V Mechanical 120 VAC, 60 Hz 48 Panel Mount Timer, 48 Trippers PB914N 24-Hour 208-277 V 208-277 VAC, 60 Hz 48 Mechanical Panel Mount Timer, 48 Trippers With Manual Override PB913N66 24-Hour 120V Mechanical 120 VAC, 60 Hz 48 Panel Mount Timer with Manual Override, 48 Trippers PB914N66 24-Hour 208-277 V 208-277 VAC, 60 Hz 48 Mechanical Panel Mount Timer with Manual Override, 48 Trippers PB913N84 24-Hour 120V Mechanical 120 VAC, 60 Hz 4 Panel Mount Timer with Manual Override, 4 Trippers PB914N84 24-Hour 208-277V Mechanical Panel Mount Timer with Manual Override, 4 Trippers 208-277 VAC, 60 Hz 4 Manual Override No No No Yes Yes Yes Yes Ratings Switch Type Resistive Tungsten Pilot Duty Motor Quick Connect Terminals Dimensions H x W x D Warranty *(16A) CSA SPST 20 A (16 A*), 120-277 VAC, 60 Hz 1250 W, 125 VAC, 60 Hz 360 VA, 120-240 VAC, 60 Hz 1 HP, 16 FLA @ 120 VAC, 60 Hz, 2 HP, 12 FLA @ 240 VAC, 60 Hz (4) 1/4" male (2) for load (2) for independent clock motor, Terminals 3.333" x 2.813" x 1.953" (84.6 mm x 71.4 mm x 49.6 mm) 1-Year limited ACCESSORIES For accessories and replacement parts please see page 184-185. 179 Pool & Spa Pool & Spa Surge Protection Protect it all with the PS3000 Surge Protective Device Did you know most power surges are caused by the on-and-off cycling of typical home appliances, not by adverse weather conditions? Homeowners rely on surge strips to protect expensive home electronics, such as computers, high definition TV's and surround sound systems, but what about expensive pool equipment? The easy-to-install PS3000 Surge Protective Device is perfect for pool and spa equipment. It is typically installed at the pool electrical panel and uses state-of-the-art TPMOV® surge technology to protect all equipment downstream of the connection point. SCAN TO LEARN MORE Don't let your pool season plans fall into the deep end because of an unexpected power surge event invest in the PS3000 Surge Protective Device from Intermatic. 180 Pool & Spa Pool and Spa Surge Protective Device Type 1 or Type 2 PS3000 Mount the PS3000 to your pool electrical panel to protect all your expensive pool and spa equipment against power surges. Designed with trusted, state-of-the-art TPMOV® (Thermally Protected Metal Oxide Varistor) surge protection technology to eliminate the potentially hazardous failure modes that are commonly associated with standard MOV technology. APPLICATIONS · Distribution Panel · Surge Protection FEATURES · TPMOV® Surge Protection Technology · UL Listed to ANSI/UL 1449, 4th edition · 120/240 VAC single-phase SPD for use on a variety of pool equipment · Green LED protection indicator · Type 4X watertight and UV resistant plastic enclosure · Three modes of protection · Includes (3) 18", #10 AWG tinned copper leads · 3-year warranty · $7,500 connected equipment warranty Model # PS3000 Wiring Configuration L1, L2, L/N-G WIRING DIAGRAMS 120/240 VAC L1 (black) Neutral (white) L2 (black) Pool & Spa Surge Protection PS3000 Ratings Service Voltage SPD Type Nominal Discharge Current (ln) SCCR* Max Surge Current Voltage Protection Rating (VPR) L-N/G L-L MCOV** L-N L-L Dimensions H x W x D Warranty 120/240 VAC Single-Phase 1, 2 20 kA 100 kA 50 kA 700 1200 150 300 3.875" x 1.625" x 4.1875" (98 mm x 41 mm x 106.4 mm) 3-Year limited Typical distribution panel installation Service Transformer Secondary Service Equipment Overcurrent device PS3000 181 Pool & Spa Pool & Spa Specialty Controls Ratings Operating Voltage Resistive Inductive Motor Dimensions H x W x D Warranty DT200LT 2x 120 VAC, 60 Hz 15 A, 120 VAC, 60 Hz 12 A, 120 VAC, 60 Hz 1/2 HP @ 120 VAC, 60 Hz 3 3/16" x 3 5/16" x 2 1/4" (81 mm x 84 mm x 57 m) 1-Year limited Digital Landscape Timer DT200LT SERIES Digital 24-hour landscape timer with DST, rated for use in low voltage transformers up to 1200W featuring ON programming at Dusk or predetermined time and OFF at Dawn or predetermined time. APPLICATIONS · Indoor Lighting Control · Outdoor Lighting Control· Landscape Water Control FEATURES · Factory set AUTO DST option takes the hassle out of Daylight Saving Time adjustments · One push, programming override for homeowner convenience · Rated for use in low voltage transformers up to 1200 W ·An operating temperature range of -40° F to 122° F (-40° C to 50° C) for steady perfor- mance in all types of climates ·Two included LR44 batteries retain the correct time and settings for up to three months without power · Use with UL Certified Type 3R enclosure (sold separately) · Intermatic Linesync technology provides accurate timing for years Model # DT200LT Amp/Supply Voltage 15 A, 120 VAC, 60 Hz Rcpt/Plug 5-15 Outdoor Mechanical Plug-In Timers With Built-In Enclosure P1100 SERIES P1101 P1121 P1131 These plug-in timers are grounded and utilize a flip-open enclosure rated for outdoor use. These heavy-duty timers are great for providing timer function to pumps, landscaping or holiday lighting. 24-hour timers come with 2 On and 2 Off settings. APPLICATIONS · Outdoor Lighting Control · Landscape Water Control · Pool Pump · Outdoor Water Fountains FEATURES ·2 ON/2 OFF settings per day with removable trippers, more ON/OFF events with addition of extra trippers · Minimum 30-min ON/OFF time · Built into outdoor rated enclosure with clear or black flip cover · Grounded standard or locking type style NEMA plug and receptacle · Plugs directly into wall outlet Ratings Resistive Tungsten/ Incandescent FLA/LRA Dimensions H x W x D Warranty P1101 P1121 P1131 15 A, 120 VAC, 60 Hz 15 A, 120 VAC, 60 Hz 20 A, 120 VAC, 60 Hz 1800 W, 120 VAC, 1800 W, 120 VAC, 60 Hz 60 Hz 1 HP, 15 FLA, 90 LRA 1 HP, 15 FLA, 90 LRA 1 HP, 16 FLA, 96 LRA @ 120 VAC @ 120 VAC @ 120 VAC 5 3/8" x 5 1/8" x 2 1/2" (137 mm x 130 mm x 64 mm) 5 5/8" x 3 5/8" x 3 1/4" (143 mm x 92 mm x 83 mm) 5 3/8" x 5 1/8" x 2 1/2" (137 mm x 130 mm x 64 mm) 1-Year limited 1-Year limited 1-Year limited Model # P1101 P1121 P1131 Rcpt/Plug 5-15 5-15 L5-20 WANT MORE TIMERS? For additional Plug-In Timers check out pages 74-79. Cord Length 22" 13" 22" Cover Black Black Black 182 Electronic Panel Mount Timers PB300 SERIES These compact Electronic Timers are specially suited for applications where equipment needs to be cycled ON and OFF up to 8 times per day, and where automatic operation of the equipment requires occasional override by someone other than a qualified service professional. They offer rugged construction, resistance to surges and humidity, operate between wide temperature extremes and come with a 5 year service life replaceable lithium battery. A light indicator illuminates when the timer is in the ON position. Select feature allows timers to be continuously ON, OFF or in AUTO mode. APPLICATIONS · Motor Control · Pump Control FEATURES · 24-hour and 7-day models · Turn equipment ON/OFF up to 8 times per day · Select feature enables timers to be continuously in ON/OFF/AUTO mode · Rugged construction · Beige, plastic enclosure · 3-year service life replaceable lithium battery Model # Resistive/Supply Voltage HP/FLA 24 hour PB313E 16 A, 120 VAC, 50/60 Hz 1/2 HP, 8 FLA @ 120 VAC, 50/60 Hz PB313EK* 16 A, 120 VAC, 50/60 Hz 1/2 HP, 8 FLA @ 120 VAC, 50/60 Hz PB314E 16 A, 240 VAC, 50/60 Hz 1/2 HP, 8 FLA @ 240 VAC, 50/60 Hz PB314EK* 16 A, 240 VAC, 50/60 Hz 1/2 HP, 8 FLA @ 240 VAC, 50/60 Hz 7 day PB373E** 20 A, 120 VAC, 50/60 Hz 1 HP, 16 FLA @ 120 VAC, 50/60 Hz PB374E** 20 A, 240 VAC, 50/60 Hz 2 HP, 12 FLA @ 240 VAC, 50/60 Hz *EK models are replacement kits for PB Series timers. **Output voltage is same as supply. Electronic Time Switch Mechanisms P7103ME These digital time switches allow multiple ON/OFF cycles within a 24-hour time period for up to seven days. APPLICATIONS · Motor Control · Pump Control FEATURES · Turn equipment ON/OFF up to 8 times per day · To-the-minute programming accuracy · Dual-voltage input (3-wire) · Timer override · Select feature enables timers to be continuously in ON/OFF/AUTO mode · 3-year service life, replaceable lithium battery Model # Description P7103ME 7-Day Electronic Time Switch Mechanism - Mechanism Only *Standard mechanism fits in all standard Intermatic enclosures and power and load centers. Pool & Spa Electronic Panel Mount Timers PB313E PB373E Ratings Switch Type 24-Hour Model 7-Day Models Dimensions H x W x D Warranty SPDT SPST 2.375" x 2.375" x 1.0625" (60.3 mm x 60.3 mm x 27 mm) 1-Year limited P7103ME Ratings Input Voltage 120 VAC, 50/60 Hz Switch Type DPST Resistive 20 A, 120/240 VAC, 50/60 Hz Tungsten 12.5 A (1500 W), 120 VAC, 50/60 Hz Motor 1 1/2 HP @ 120 VAC, 50/60 Hz; 3 HP @ 240 VAC, 50/60 Hz Dimensions 9.4375" x 6.5" x 3.6875" H x W x D (239.7 mm x 165.1 mm x 93.7 mm) Warranty 1-Year limited 183 Pool & Spa Pool & Spa Pool & Spa Portable Outdoor Timers & Enclosures P1251P Two-Circuit Portable Outdoor Timers P1200 SERIES Use these convenient plug-in timers instead of hard-wired controls. They offer plug-in receptacles for convenience and ease of use. They have built-in GFCI protected circuits. APPLICATIONS · Landscape Lighting · Motor Control · Pump Control FEATURES · 24-hour with 23 ½-hour MAX ON time · Timed circuit controlled by timer · Timed and photocontrol circuit controlled by photocell and timer (P1251P only) · Built-in GFCI protected circuits and three-prong grounded plug for time switch supply · Type 3R plastic indoor/outdoor enclosure · 2 ON/OFF trippers standard · Accepts up to 12 sets of trippers Ratings Resistive Tungsten Motor Dimensions H x W x D Cord Warranty 15 A, 1800 W, 60 Hz 15 A, 1800 W, 60 Hz 1 HP, 15 FLA, 90 LRA @ 120 VAC 9.375" x 5.5" x 4" (238.1 mm x 139.7 mm x 101.6 mm) 3 wire, outdoor grade, 24" with grounded plug 1-Year limited Model # P1251P P1261P ENCLOSURES Model # 2T2483GR 2T2485GA 2T2502GA 2T2503A 2T2485GA 2T2502GA Photocontrol Yes No Rect/Plug 5-15 5-15 Description Flush Mount Metal, Type 1 Case-Outdoor, Type 3R Metal, Beige Case-Outdoor, Type 3R Plastic, Beige Case-Outdoor, Type 3R Plastic, Beige 2T2485GA Dimensions 10 1/8" 5/16" 3X 8 1/16" 2X 8 5/8" 3/16" 3/8" 1 7/16" 6 1/2" (2) KNOCKOUT 1/2" & 3/4" (1 THIS SIDE & 1 OPP. SIDE) 2X 1 5/8" 1 1/16" 2 1/8" 1 7/16" 1/4" 3 5/8" 2X 1/4" MOUNTING HOLES 1 5/8" 3 1/4" KNOCKOUT 1/2" & 3/4" (2) KNOCKOUT 1/2" & 3/4", 2T2502GA Dimensions 6 1/2" R1/8" 4" 2 3/4" 8 1/16" 10" 8 1/16" 8" 2X 8 1/2" 1 1/2" (2) KNOCKOUT 1/2", 3/4" (1 THIS SIDE & 1 OPP. SIDE) 1 1/2" (2) KNOCKOUT 1/2", 3/4" 1 5/8" 3 1/4" 2X 1/4" MOUNTING HOLES KNOCKOUT 1/2", 3/4" 1 1/16" 1 5/8" 2 1/16" 184 Model # 119--00085 124--00066 124--00139A 124-00140A 107HB254 107HB255 124T1952 124T2411A 133RC1144 143RC140 143RC151 143T145A 119T267 119T340 143T135 143T136 156PB10398A 156T1978A 156T4042A 156T6738A 178PA28A 178T24 178T26A 21T156A 21T166A 22T904A 6LV1352 PA102 PA114 PA115 PA117 PA119 PA122 PE953 WG1570-10 WG1573-10D WP1000C WP5100C ACCESSORIES Description Transformer - 100 W, 120 V, 60 Hz Insulator for 3-Circuit Timers Insulator breaker base 4 pole Insulator breaker base 8-pole Green (ON) tripper for HB11, HB1113RC, HB1116R, HB3116R8, P1121 (Outdoor) Red (OFF) tripper for HB11, HB1113RC, HB1116R, HB3116R8, P1121 (Outdoor) Insulator (Black) for Double-Pole Time Switch (T103, T104, T105, T173, T174, T175, T176, T185, WH40) Insulator for Mechanical Time Switches - 10 Pack Pressure Sensing Momentary Air Switch - 3 A Relay - 4-Function Stepper Relay - DPST, 3 HP, 24 VAC Relay - DPST, 3 HP, 24 VDC Transformer - 100 W, 120 V, 60 Hz Transformer - 300 W, 120 V, 60 Hz Relay - DPST, 3 HP, 240 VAC Relay - DPST, 3 HP, 120 VAC Trippers - Clip, ON/OFF, 24-Hr for PB and PF1100 Series Extra/replacement trippers 1 ON and 1 OFF Fireman Switch Orange Vinyl Cushion/Insulator for Time Switch Manual Lever, 10 pack Freeze Probe Kit, 10k OHM, For MultiWave systems Freeze Protection Thermostat TSTAT ASY-FREEZE PROTECT (contains 178T24) For PF1xxx Freeze Protection units Spacer-Standoff, 3" long - 4 pack Spacer-Standoff, 3" long - 2 pack Breaker Hold-Down Kit (If breaker is used as a backfed device) Light Shield Accessory for EK4036S, EK4436SM, K4000 Series Button Photocontrols Switch Assembly with Thermostat and Relay Mounting Bracket for Pool/Spa Light Junction Boxes Trippers - OFF - 25 pack Replacement Latch Kit Mounting Bracket for PJBX52100 COMBOConnect® Water/Solar Temperature Sensor, 10k OHM, For MultiWave systems Wireless Remote, MultiWave systems WG1570-10 208-277 VAC, 60 Hz Motor for T102, T104, T106, T172, T174, WH40 Plastic In-Use Weatherproof Cover, Single-Gang, Vrt, 2.25" Clear Extra-Duty Plastic In-Use Weatherproof Cover, Single-Gang, Vrt/Hrz, 2.75" Clear PA119 143T135 PA115 178T24 Pool & Spa Accessories 22T904A 143RC140 156PB10398A 119--00085 185 Pool & Spa Enclosure Solutions Protect timer controls and various styles of receptacles from the elements with code-compliant outdoor enclosures. Our die-cast, low-profile and plastic weatherproof covers offer rugged protection in all types of applications, including industrial, commercial and residential. Type 1 Enclosures Install Type 1 enclosures in indoor applications for a secure, finished look. These heavy-duty steel solutions provide a tidy access point for essential timer controls and can be locked to prevent unauthorized access. Type 3R Enclosures Choose Type 3 enclosures in outdoor applications for lasting protection against the elements all year round. These solutions can be used with mechanical and electronic timers to support a variety of scheduling needs. Built-in Knockouts Save time during installation by using one of the built-in knockouts found throughout our enclosures. These thoughtfully placed spaces can be quickly punched out to run wiring and tailor the enclosure to meet project requirements. Specialty Mounting Ensure a perfect fit with a selection of mounting brackets. These solutions help panel mount standardized electronic or mechanical timers. Contents Metal Enclosures188 Plastic Enclosures189 Specialty Mounting Options190 NOM 191 Timer Selection Guide192 Enclosures and Reference Enclosures and Reference Metal Enclosures ENCLOSURE DIMENSIONS 7 7/8" 7 7/8" 2 1/2" 3/8" R1/16" R1/8" 5X 5 11/16" (3 KNOCKOUTS) Indo2o1/r2"Metal Enclosure 3/8T" YPE 1 - METRA1/LR116/"8" (3 5X 5 11/16" KNOCKOUTS) These drawn steel, p3ow7/d1e6r"coated enclosures offer a spring style hasp to ensure the enclosure remains closed a4n1d/1a6llo"ws6fo1r1/a1l6o"ck to be used to prevent unauthorized access 7 1/4" to the controls. 3 7/16" (2) KNOCKOUT 1/2" & 3/4" (1 THIS SIDE & 1 OPP. (S2I)DKEN)OCKOUT 1(1/2T"H&1IS33S//41ID"6E" & 1 OPP. SIDE) 3" 3 7/16" 1 3/16" 3 7/16" 2T2040GA FEATURES 4 1/16" 6 11/16" 7 1/4" · Drawn steel with gray powder coat paint finish ·Combination ½" and 3/4" no1m/8in"al knockouts with one on back and each side of 33"7/16" 5 1/8" 5 1/8" 1 3/16" 1 1/4"enclosure, and two on bo3tt/o1m6" 1/8" (12/)2K" N&1O33C//41K"6O"UT 1 3/8··1"CL1oo/c4nk"v2aebn1li/ee2n"htamspouhnotldinsgdhooo(1l1re/)s2cK"3lo/N&s1Oe63d"C/4K"OUT (2) KNOCKO2U1T1/116"3/8" (13) K/1N6O" CKOUT 1/2" & 3/4" 2 1/2" 1/2" & 3/4" 3 7/16" 15/16" 1 3/16" 2 11M/1o6d"el # Color 3/16" Dimensions H x W x D 15/16" 1 7/8" 1 3/16" 2T2040GA Gray 7 7/8" x 5 1/8" x 3 7/16" 1 7/8" (200 mm x 130.2 mm x 87.3 mm) 2 1/2" 3/8" R1/16" R1/8" 5X 5 11/16" (3 KNOCKOUTS) Accepts a wide range of Intermatic Time Switches, including most T100, T170, T1900, T2000, C8800, EH, ET1100, ET1700, ET2000, ET8000, ET90115, and ET902152S1e/r2ie"s units. R1/16" 3/8" R1/8" 5X 5 11/16" (3 KNOCKOUTS) 7 7/8" 7 1/4" 3 7/16" 4 1/16" 6 11/16" 7 7/8" 7 1/4" 3 7/16" 4 1/16" 6 11/16" 1 3/16" 1 1/4" (2) KNOCKOUT 1 3/8" 1/2" & 3/4" 2 11/16" 2 1/2" 1 3/16" 1 7/8" 2T511GA 1 7/16" 6 1/2" (2) KNOCKOUT 1/2" & 3/4" (1 THIS SIDE & 1 OPP. SIDE) 188 2X 1 5/8" 1 1/16" 2 1/8" 2T2485GA 1/8" 3/16" (1) KNOCKOUT 1/2" & 3/4" 3/16" (2) KNOCKOUT 1/2" & 3/4" (1 THIS SIDE & 1 OPP. SIDE) 1 3/16" 3 7/16" 3" 3 7/16" 5 1/8" 1 3/16" 1 1/4" (2) KNOCKOUT 1 3/8" 1/2" & 3/4" 2 11/16" 2 1/2" 1/8" 3/16" (1) KNOCKOUT 1/2" & 3/4" 3/16" 10 1/8" ENCLOSURE DIMENSIONS 1 7/16" 6 1/2" (2) KNOCKOUT 1/2" & 3/4" (1 THIS SIDE & 1 OPP. SIDE) 5/16" 3/16" 2X 1 5/8" 1 1/16" 3X 8 1/16" 2 1/8" 2X 8 5/8" 10 1/8" 1O5/u16t"door Metal 5/16" E1n3c/1l36o/"16s"ures TYPE 3R RAIN1P7R/8O" OF - MET3A/8L" These drawn steel, powder coated enclosures keep controls protected from rain, sleet, snow, and ice. They have a swinging hasp that allows for a lock to be used to prevent unauthorized 3aXcc8e1s/1s6t"o the controls. FEATURES 10 1/8" 2X 8 5/8" · Drawn steel with gray or beige powder coat paint finish ·Combination ½" and 3/4" nominal knockouts with one on back and each side of enclosure, and two on bottom · Separate g2rXoun1d/4in"g terminal 1 7/16"· · ConveMnOieUnNtTmINoGuHnOtinLgESholes Lockable hasp hold1s5/d8o" or clo3s1e/4d" 1/4" Model # Color KNOCKOUT 1/2" & 3/4" Dimensions H x W x D 3/8" 3 5/8" For 5/16" Most Mec3h/1a6n" ical and Electronic Controls 2T511GA* Gr3a/y8" 10 1/8" x 6 1/2" x 3 5/8" (2) KNOCKOUT 1/2" & 3/4", (257.2 mm x 165.1 mm x 92.1 mm) 2T2485GA* 3X 8 1/16" Beige 10 1/8" x 6 1/2" x 3 5/8" (257.2 mm x 165.1 mm x 92.1 mm) 2X 8 5/8" For Carry-Over Models 1 7/16" 117//41"6" 3 5/8" 2X 1/4" MOUNTING HOLES 1 5/8" 6 1/2" (2) KNOCKOUT 1/2" & 3/4" (1 THIS SIDE & 1 OPP. SIDE) 3 1/4" 1 7/16" 1/4" 2T2331GA** Gray 10 1/8" x 6 1/2" x 3 11/16" KNOCKOUT 1/2" & 3/4" (257.2 mm x 165.1 mm x 93.7 mm) 2X *A1v/4a"ilable for T100, T170, MOUNTINGETH9O02L1E5SSeries units. T1K9N0O0,CTK2O00U0T 1/2" & 3/4" ,C8800, EH, ET1100, ET1700, ET2000, ET8000, ET90115, and **Avai1la5b/le8"for T100CR, T170CR, T1400, and T1800 Series units. 3 1/4" (2) KNOC2XKO1 U5/T8" 1/2" & 3/4", 1 1/16" 2 1/8" 3 5/8" (2) KNOCKOUT 1/2" & 3/4", Enclosures and Reference Outdoor Plastic Enclosures TYPE 3R RAINPROOF - PLASTIC These heavy-duty industrial grade plastic enclosures include molded mounting brackets for easy installation and have a lockable hasp to prevent unauthorized access to the controls. These plastic enclosures are non-corroding, and are great for applications in high moisture or dusty locations. FEATURES · Heavy-duty industrial grade plastic · Perfect for high humidity and dusty environments · Combination 1/2" and 3/4" nominal knockouts with one on back and each side of enclosure, and two on bottom · Lockable hasp holds door closed Model # Color Dimensions H x W x D 2T2500GA Gray 10" x 6 1/2" x 4" (254 mm x 165.1 mm x 101.6 mm) 2T2502GA Beige 10" x 6 1/2" x 4" (254 mm x 165.1 mm x 101.6 mm) 2T2926A Gray 10" x 6 1/2" x 4" (254 mm x 165.1 mm x 101.6 mm) Accepts a wide range of Intermatic Time Switches, including most T100, T170, T1900, T2000, C8800, EEHN, CETL1O10S0U, ERTE170D0I,METE2N00S0I,OENT8S000, ET90115, and ET90215 Series units. 6 1/2" 4" R1/8" Enclosures and Reference Plastic Enclosures 2T2500GA 2 3/4" 2T2926A 8 1/16" 10" 8 1/16" 8" 2X 8 1/2" 1 1/2" (2) KNOCKOUT 1/2", 3/4" (1 THIS SIDE & 1 OPP. SIDE) 1 1/2" (2) KNOCKOUT 1/2", 3/4" 1 5/8" 3 1/4" 2X 1/4" MOUNTING HOLES KNOCKOUT 1/2", 3/4" 1 1/16" 1 5/8" 2 1/16" Case-Outdoor, Type 3R Plastic, Gray E200 FEATURES · Type 3R Outdoor enclosure · High impact all-plastic enclosure eliminates rust and corrosion · Rugged heavy duty construction · Provision for a padlock seal · Five combinations of 1/2" and 3/4" knockouts Model # E200 Color Gray Dimensions H x W x D 8 41/64" x 6 1/2" x 3 3/4" (219.45 mm x 165 mm x 95 mm) ENCLOSURE DIMENSIONS 6,5" [16,5 cm] 5,54" [14,1cm] 10" [25,4 cm] 8,64" [21,9 cm] 3,74" [9,5 cm] E200 189 Enclosures and Reference Enclosures and Reference Specialty Mounting Options 2T308A Enclosure Dimensions 8" 8" Flush Mount Metal Enclosures TYPE 1 RATED These enclosures are great for concealing the controls in the wall to provide a finished, flush appearance. Enclosures are made of heavy-duty steel and also include a locking mechanism to prevent unauthorized access to the controls. FEATURES 8" · Heavy-duty construction with hinged door 14" · Lockable door with key · Various mounting holes Model # Color Dimensions H x W x D Riveted Mounting Bracket 2T2365GA* Gray 9 1/8" x 6" x 4 1/8" 11" (231.8 mm x 152.4 mm x 104.8 mm) Adjustable Bracket Mount Locations 2T308A** Gray 9 1/8" x 6" x 4 1/8" 231.8 mm x 152.4 mm x 104.8 mm *Available for ET1100, ET1700, ET2000, ET8000, EH, ET90115, and ET90215 series units. **Available for T100, T170, T1900, T2000, and C8800 series units. 14" 14" 4" 4" 114" 114" (2) KNOCKOUT 1/2" & 3/4" 238" 11" 11" 918" 918" 114"114" 114"114"(2)1K/2(N2"O)1&K/C23NK"/OO4&"CU3TK/O4"UT 238" 238" 115161" 1516" 2" 2" 1516" 1516" 3" 6" 114" 1" 3" 3" 6" 6" 114" 114" 1" 1" 22T338GR Mounting Bracket for Intermatic Standardized Timer Mechanisms 22T338GR This bracket has been designed to be used when mounting the controls into areas where an enclosure will not be needed or when mounting the control into another form of enclosure. The bracket also accepts a wide range of Intermatic controls FEATURES · Ideal for panel mounting mechanical or electronic time switch controls Model # Description Dimensions H x W x D 22T338GR Mounting Bracket for Intermatic 6" x 5" x 2" Standardized Timer Mechanisms (152.4 mm x 127 mm x 50.8 mm) Accepts a wide range of Intermatic Time Switches, including most T100, T170, T1900, T2000, C8800, ET1100, ET1700, ET2000, ET8000, ET90115, and ET90215 series units. 190 Enclosures and Reference Enclosures and Reference NOM ELECTRICAL DISTRIBUTION PRODUCT OFFERING FOR MEXICO OFERTA DE PRODUCTOS PARA DISTRIBUDORES MEXICANOS Para satisfacer el mercado Mexicano, Intermatic ofrece los siguientes productos a distribuidores eléctricos industriales. Los productos cumplen con los requisitos de seguridad y calidad exigida por el mercado Mexicano y están respaldados por certificación NOM. Para información detallada del producto, por favor referirse a la sección y pagina indicada. Intermatic continua expandiendo su oferta de productos para el mercado Mexicano, por favor contactar a nuestros representantes de ventas para productos no listados. Model # No Pagina Controladores Electronicos Basico ET1105CMX 26 ET1125CMX 26 ET1705CMX 26 ET1725CMX 26 ET8015CMX 26 ET8115CMX 26 ET8115CPD82MX 26 ET8215CMX 26 ET8415CRMX 26 Controladores Electronicos Avanzado ET90115CMX 22 ET90115CRMX 22 ET90215CMX 22 ET90215CRMX 22 Controladores Electronicos para Paneles de Control FM1D20-120UMX 31 FM1D20A-120MX 31 FM1D20A-240MX 31 Temporizadores Mecanicos 24-Hr T101MX 40 T101PMX 40 T101RMX 40 T102MX 40 T102PMX 40 T103MX 40 T103PMX 40 T104MX 40 T104PMX 40 T104RMX 40 156T1978AMX 40 T171MX 41 T173MX 41 T174MX 41 T1471BRMX 41 T1472BRMX 41 T1905MX 42 T1905EMX 42 T1906MX 42 T1975MX 42 T1976MX 42 Temporizadores Mecanicos 7-Dias T7401BMX 44 T7402BMX 44 T7801BMX 44 T2005MX 45 Temporizadores Especializados Electromecanico Mutivoltage GM40AVMX 50 Temporizadores Mecanicos para Paneles de Control FM1STUZ-120UMX 47 FM1STUZ-240UMX 47 FM1SWUZ-120UMX 47 Temporizadores Especializados de Ciclo CT2000MX 56 Temporizadores Especializados Calentador de Agua EH10MX 59 EH40MX 59 Model # No Pagina Temporizador de pared Mecanico - 24hrs KM2ST-1GMX 67 E1020MX 66 Temporizador de pared Electronico - 7dias ST01MX 64 Temporizador de pared Cronometraje Mecanico FD5MMX 70 FD15MCMX 70 FD30MCMX 70 FD60MCMX 70 FD2HMX 70 FD4HMX 70 FD6HMX 70 FD12HCMX 70 FD430MMX 70 FD460MMX 70 FF5MMX 71 FF5MHMX 71 FF15MCMX 71 FF30MCMX 71 FF60MCMX 71 FF6HMX 71 FF12HCMX 71 FF60MHCMX 71 Temporizador de pared Cronometraje Electronicoo EI200MX 69 EI200WMX 69 EI200LAMX 69 EI210MX 69 EI210WMX 69 EI210LAMX 69 EI220MX 69 EI230MX 69 EI400CMX 68 EI500CMX 65 Temporizador enchufable Mecanico - 24hrs TN311MX 77 TN111RM40MX 78 Temporizador enchufable Electronico - 7-Dias DT620MX 79 HB880RMX 79 Sensores de Ocupación de pared IOS-DDR-WHMX 86 IOS-DSR-IVMX 85 IOS-DSR-WHMX 85 IOS-DOV-WHMX 86 IOS-DPBIF-WHMX 87 IOS-DSIF-IVMX 87 IOS-DSIF-WHMX 87 IOS-DSIMF-IVMX 87 IOS-DSIMF-WHMX 87 IOS-DPBIMF-WHMX 87 Sensores de Ocupación de techo IOS-CMP-ULCMX 84 IOS-CMP-UMX 84 IOS-HB-UMX 84 Model # No Pagina Fotoceldas Fijos - Iterruptor Termico K4021CMX 96 K4023CMX 96 K4321CMX 96 K4121CMX 95 K4123CMX 95 K4221CMX 95 K4223CMX 95 K4236CMX 95 K4251MX 95 K4141CMX 95 Fotoceldas Enchufable - Interruptor Termico LC4513MX 94 LC4521MX 94 LC4523MX 94 LC4536CMX 94 LC4536LACMX 94 LC2100MX 94 Fotoceldas Enchufable -Electronico LED4536SCMX 92 EK4536MX 92 ELC4536MX 92 Fotoceldas - Accesorio K121MX 97 K121-30MX 97 K122MX 97 K171H 97 Supresores de Corriente 50KA para Residencias y Edificios Commerciales IG1200RC3MX 129 IG1240RC3MX 129 Supresores de corriente 50KA Installable a la Interperie AG2401C3MX 128 Supresores de Corriente para Equipos HVAC AG3000MX 136 Cubiertas para Intemperie Plasticas WP3100CMX 148 WP1000CMX 149 WP1020CMX 150 WP1220CMX 151 Visit Intermatic.com for more information. 191 Enclosures and Reference Enclosures and Reference Timer Selection Guide Mechanical/Electronic Time Switch Type 24-Hour, 7-Day or 365-Day Electromechanical Auto-Voltage or Multivoltage 24-Hour or 7-Day # of Circuits A Rating Switch Rating 1 40 SPDT, DPDT Total ON/OFF Events 96-Events for 24-Hours/ 48-Events for Weekly with Captive Trippers Mechanical Panel Mount 24-Hour or 7-Day 1 21 SPDT 96-Events for 24-Hours/ 48-Events for Weekly with Captive Trippers Mechanical Flush, Surface or DIN Rail Mount 24-Hour or 7-Day 1 21 SPDT 96-Events for 24-Hours/ 48-Events for Weekly with Captive Trippers Mechanical Mechanical General Purpose 24-Hour with Skipper 24-Hour 24-Hour 1 40 SPST, SPDT, DPDT 12 1 40 SPST, SPDT, DPDT, 4PST 10 Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Electromechanical Mechanical Mechanical Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic 24 Hour with Skipper 24-Hour 1 Percentage Cycle Timer 1, 3, 5, 10, 30-Minutes; 1, 4-Hours 1 (CT1000 does not have a 4-Hour Increment) Irrigation/Sprinkler 24-Hour with Skip-a-day Selection 1 Compact 7-Day 7-Day 1 7-Day Dial with/without 7-Day 1 Carry-over Water Heater 24-Hour 1 20 20 15-25 20 40 40 Defrost Timer In-Wall Spring Wound 24-Hour Decorator and Commercial Style In-Wall Mechanical 24-Hour Auto-Voltage 120-277 VAC Panel Mount Flush, Surface or DIN Rail Mount 24-Hour, Multivoltage 24-Hour with Holiday, Multivoltage 7-Day, Multivoltage 7-Day with Holiday, Multivoltage 7-Day Astronomic, Multivoltage 7-Day Astronomic with Holiday, Multivoltage 365-Day Advanced Control Water Heater In-Wall In-Wall In-Wall In-Wall 24-Hour or 7-Day 24-Hour and/or 7-Day 24-Hour and/or 7-Day 24-Hour 24-Hour with Exceptions 7-Day with Exceptions 7-Day with Exceptions Astronomic 7-Day Astronomic 7-Day with Exceptions 365-Day 7-Day with Exceptions Count Down Timers in Various Increments Programmable Countdown Timer 24-Hour Programmable 7-Day Programmable 7-Day with Astro 1 40 1 15 1 20 1 40 1 & 2 16 1 & 2 16 1 & 2 30 1, 2 & 4 30 1 & 2 30 1, 2 & 4 30 1 & 2 30 1, 2 & 4 30 1, 2, 4, 8 & 16 30 1 30 1 15 1 20 1 15 1 15/20 SPDT 96 SPST 3% to 97% Cycle Duration SPDT SPDT 4PST DPST SPDT, SPST Varies SPST SPDT, DPDT SPDT SPDT SPST, DPST SPST, SPDT, DPST SPST, SPDT, DPST 60 84 Different ON/OFF Program for Each Day of the Week T104-20 (2 ON/OFF per Day) WH (1 ON/OFF per Day) 1 to 24/24-Hour Period Various increments with/without "HOLD" 36 (72 Captive Trippers in 20-Minute Increments) 96 Various Various 28 96+ 28 96+ 28 96+ SPST, SPDT, DPST, DPDT 2000+ SPST, DPST 42 SPST N/A Single Pole/Three Way 1 Single Pole Single Pole/Three Way 7 40/Week 192 Enclosures and Reference Enclosures and Reference Timer Selection Guide Minimum ON/OFF Time 15-Minutes for 24-Hours/ 48-Events for Weekly with Captive Trippers Temperature Input Skip-A-Day Carry-over Astro Daylight Saving Time Product Series No Yes Optional No No GM40AV 15 Minutes for 24 Hours/48 Events for No Weekly with Captive Trippers No Optional No No FM1 - SERIES Page(s) 50 47 15 Minutes for 24 Hours/48 Events for No Weekly with Captive Trippers No Optional No No MIL72 SERIES 48-49 1 Hour 1 Hour 15 Minutes 1 Second No No No No T100 40 Yes Optional No No T170 41 Yes Optional No No T1900 42 No No No No CT2000 56 12 Minute 2 Hours 3.5 Hours 1 Hour Yes No No No No No No No No Optional No No No Yes No No R8800/T8800 Series 57 T2000 45 T7000 Series 44 T104-20/WH40 59 15-Minutes Minimum ON/OFF Time; Yes 23-Hours 45-Minutes Max Off Time Varies 20 Minute 1 Minute 1 Minute No 1 Minute No 1 Minute 1 Minute 1 Minute 1 Minute 1 Minute 1 Minute 1 Second 1 Minute Varies 1 Second 1 Minute 1 Minute No Optional No No N/A N/A N/A N/A N/A N/A N/A N/A Yes Yes No No Yes Yes No Yes Yes Yes No Yes Yes Yes No Yes Yes Yes No Yes Yes Yes No Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No N/A N/A N/A N/A N/A N/A No No N/A N/A No No N/A N/A Yes Yes DTAV40 FD Series & FF Series KM2 Series GM40AVE-RD89 FMD - SERIES FMD - A&E SERIES ET1100 ET2100 ET1700 ET2700 ET8000 ET2800 ET90000 EH Series EI200 EI400 EI500 STO1/EI600 108 70-71 67 34 30-33 30-33 26 24 26 24 26 24 22 59 69 68 65 64 193 Enclosures and Reference Enclosures and Reference Notes NOTES Table of Contents · ADVANCED LIGHTING CONTROLS (PAGES 10-19) · ELECTRONIC CONTROLS (PAGES 20-37) · MECHANICAL TIME SWITCH (PAGES 38-53) · SPECIALTY TIMERS (PAGES 54-59) · IN-WALL TIMERS (PAGES 60-73) · PLUG-IN TIMERS (PAGES 74-79) · OCCUPANCY SENSORS (PAGES 80-87) · PHOTOCONTROLS (PAGES 88-99) · HOUR METERS (PAGES 100-105) · R EFRIGERATION TEMPERATURE CONTROLS (PAGES 106-117) · SURGE PROTECTION (PAGES 118-133) · HVAC SURGE & POWER PROTECTION (PAGES 134-139) · WEATHERPROOF COVERS (PAGES 140-153) · POOL & SPA (PAGES 154-185) · ENCLOSURES & REFERENCE (186-193) 194Adobe InDesign 16.4 (Macintosh) Acrobat Pro DC 21.7.20099