CANARMNA INSTALLATION INSTRUCTIONS

Model Numbers: DL-11C-15FC, DL-11C-22FC, DL-15A-30FC, DL-15C-30FC

Components

The package includes:

Important Safety Information

Please read these instructions carefully before attempting to install this product. Keep these instructions in a safe place for future reference.

Warnings and Cautions

Electrical Connections

⚠️ WARNING: All electrical connections must comply with local and National Electrical Code (N.E.C.) standards. If you are unfamiliar with electrical wiring, consult a qualified electrician.

Risk of Electric Shock

⚠️ WARNING: RISK OF SHOCK. Electric current can cause painful shock or serious injury unless safety precautions are followed:

  1. Turn off the power supply at the fuse or circuit breaker box before installing the fixture. [power-off symbol]
  2. Ground the fixture to avoid potential electric shocks and ensure reliable starting. [ground symbol]
  3. Double-check all connections to ensure they are tight and correct. [check mark symbol]
  4. Wear rubber-soled shoes and work on a sturdy wooden ladder. [ladder symbol]

Fire Risk and Circuit Compatibility

⚠️ WARNING: Risk of fire. Use only on 120-volt, 60Hz circuits. Suitable for wet locations. Thoroughly review enclosed installation manual before installation.

❗ CAUTION: TURN OFF THE MAIN POWER AT THE CIRCUIT BREAKER BEFORE INSTALLING THE FIXTURE TO PREVENT POSSIBLE SHOCK.

This fixture is designed for use in a circuit protected by a fuse or circuit breaker and must be installed according to local electrical codes. Consult a qualified electrician or local electrical inspector if unsure.

Risk of Cuts

⚠️ WARNING: RISK OF CUTS. Some metal parts may have sharp edges. Wear gloves when handling parts to prevent cuts and scrapes. [gloves symbol]

Wet Location Installation

❗ CAUTION: FOR WET LOCATION INSTALLATION ON UNEVEN SURFACES, APPLY GASKET OR CAULKING COMPOUND TO THE BACK OF THE FIXTURE FOR A SEAL AGAINST THE MOUNTING SURFACE.

Maintenance & Care

  1. Ensure power is disconnected before cleaning. [power-off symbol]
  2. To preserve the product's finish, wipe periodically with a soft cloth. [cloth symbol]
  3. Do not use harsh chemical solvents, as they may discolor or damage the finish. [no-chemicals symbol]

Preparation for Installation

  1. Read these instructions carefully before attempting installation.
  2. Disconnect electrical power before installing or servicing any part of this fixture. [power-off symbol]
  3. Place the fixture on a clean, flat surface. [flat-surface symbol]

Installation Steps

Step 1: Mount the Bracket

Description: Attach the mounting bracket to the electrical box in the ceiling using the provided electrical box screws. If mounting to drywall without a junction box, use plastic wall anchors and wood screws. Ensure the bracket is securely fastened.

Diagram Description: Diagram illustrates the mounting bracket being secured to a ceiling electrical box. It shows a plastic wall anchor, a wood screw, and an electrical box screw as fasteners.

Step 2: Align Fixture Plate

Description: Place the fixture plate against the ceiling, aligning it with the mounting bracket. Use the labels and arrows on the plate and ceiling as guides for proper alignment. Ensure the labels line up with the ends of the installation plate.

Diagram Description: Diagram shows the fixture plate being positioned on the ceiling. It highlights alignment using labels and arrows, indicating that these should line up with the ends of the installation plate.

Step 3: Connect Wires

Description: Connect the fixture wires to the supply wires using the provided wire nuts. Connect white (neutral) supply wire to white fixture wire. Connect black (hot) supply wire to black fixture wire. Connect green/yellow ground wire from supply to fixture ground wire. Ensure all connections are secure.

Diagram Description: Diagram details electrical wiring connections. It shows supply wires (WHITE (NEUTRAL), BLACK (HOT), GREEN/YELLOW (GROUND)) being connected to corresponding fixture wires (WHITE, BLACK, FIXTURE GROUND) using WIRE NUTS.

Step 4: Attach Fixture

Description: Align the red arrow on the fixture with the arrow on the ceiling plate. Ensure they are properly lined up. Then, install the fixture onto the plate. ❗ CAUTION: Ensure no wires are pinched between the mounting plate and the fixture.

Diagram Description: Diagram illustrates aligning the fixture with the mounted plate. A red arrow on the fixture and an arrow on the ceiling plate must be aligned before installing the fixture. A caution states: 'Ensure no wire is pinched between the installation plate and the fixture'.

Step 5: Complete Installation

Description: Once the fixture is securely attached, the installation is complete. Tear off any temporary labels.

Diagram Description: Diagram indicates the final stage of installation, with the text 'Installation completed and tear the labels'.

Compatibility and Specifications

Operating Temperature: 0°F - 120°F

Dimming: Dimmable with LED compatible dimmers. If flickering occurs at low dimming levels, increase the light level. Compatible with most dimmers.

Compatible Dimmers: LEVITON# 742-6672-HLW, LEVITON# 722-6674-PDW, LUTRON# SCL-153PH-WH

Maximum Lamps per 150W Dimmer:

Models: DL-11C-15FC, DL-11C-22FC, DL-15A-30FC, DL-15C-30FC, Flush Mount Ceiling Light

PDF preview unavailable. Download the PDF instead.

11&15in Instruction Round EN&FR 2020-5-26 Microsoft Excel 2016

Related Documents

Preview CANARM XFS Light Commercial Wall Exhaust Fans Instruction Manual
Comprehensive instruction manual for CANARM XFS series light commercial wall exhaust fans, covering installation, operation, maintenance, specifications, and warranty information.
Preview Canarm DC Industrial Ceiling Fan - Features, Specifications, and Controls
Explore the features, specifications, and control options for Canarm's DC Industrial Ceiling Fans. Learn about their energy efficiency, performance, and installation requirements, including the necessary RREM-DCQ014-W wall control.
Preview Canarm Commercial Circulating Fans - PBKD, WMKD, CCU Series
Explore Canarm/LFI's high-velocity commercial circulating fans, including PBKD, WMKD, and CCU series. Features include 3-speed motors, durable construction, and various mounting options for efficient air movement.
Preview Canarm EC Motors Speed Control Operation Manual and Wiring Guide
Comprehensive guide to Canarm's EC (Electronically Controlled) Motor Speed Control, including operation, wiring diagrams, troubleshooting messages, and remote potentiometer control options for 120V and 208-230V systems.
Preview CANARM DSQ-B Series Centrifugal Fan Performance and Sound Data
Detailed performance and sound data for CANARM's DSQ-B series centrifugal fans, including fan curves, specifications, and sound ratings for models DSQ-B-10 through DSQ-B-27.