Product Series and Components
The following product series and associated components are covered:
- Ecostat 1001 / 2001 / 5001
- Associated part numbers: 94285000, 97528000
- Component part number: 95835000
- Component part number: 97236000
- Component part number: 97220000
- Component part number: 97657000
- Metropol S
- Associated part number: 97927XXX
- Citterio / Starck X
The initial page displays an overview of various components and parts for the Ecostat and Metropol S series, including cartridges, seals, and housings.
Ecostat 1001 / 2001 / 5001 Installation Steps
Follow these steps for installation or service:
Step 1: Use a 10 mm hex key ([tool]) to loosen and remove the handle. Unscrew the retaining nut.
[arrow] indicates removal of a component.
Step 2: Detach the decorative cover. Remove the internal component (e.g., cartridge or seal).
[arrow] indicates removal of a component.
Step 3: Reassemble components. Tighten a specific nut using a 10 mm hex key ([tool]) to a torque of 20 Nm. Insert the final part.
[arrow] indicates insertion of a component.
Citterio / Starck X Installation Steps
Follow these steps for installation:
Step 1: Attach the mounting plate to the faucet body. Secure it using a screw with a 5 mm hex key ([tool]).
[arrow] indicates the direction of attachment.
Step 2: Install the component (part number 97236000) onto the faucet body. Use a 7 mm hex key ([tool]) and tighten to a torque of 18 Nm.
Installation and Service for Component 95835000
Procedure Set 1 (Pages 4-5)
Step 1: Connect the component to the water supply outlets using a 23 mm wrench ([tool]).
Step 2: Attach another component as indicated by the [arrow].
Step 3: Insert a small seal or filter using a 2.5 mm hex key ([tool]).
Step 4: Attach the handle. Use a 6 mm hex key ([tool]) and tighten to a torque of 20 Nm. Discard any old parts into a [trash] bin.
Step 5: Repeat attachment and tightening procedures as shown.
Step 6: Secure a component using a 2.5 mm hex key ([tool]).
Step 7: Insert small seals or filters into the respective openings.
Step 8: A hand is shown turning a component, likely for adjustment or final seating.
Step 9: Tighten a component using a 2.5 mm hex key ([tool]) to a torque of 2 Nm.
Step 10: Secure the main connection using a 23 mm wrench ([tool]) tightened to a torque of 17 Nm.
Procedure Set 2 (Pages 6-7)
Step 1: Connect components to the main body.
Step 2: Install components using a 10 mm hex key ([tool]).
Step 3: Attach a component using a 6 mm hex key ([tool]) and tighten to a torque of 20 Nm.
Step 4: Install components using a 2.5 mm hex key ([tool]).
Step 5: Insert small seals or filters into openings.
Step 6: A hand is shown turning a component for adjustment.
Step 7: Tighten a component using a 2.5 mm hex key ([tool]) to a torque of 2 Nm.
Step 8: Secure the main connection using a 23 mm wrench ([tool]) tightened to a torque of 17 Nm.
Step 9: (Diagram shows a component being tightened with a 2.5mm hex key to 2 Nm, similar to step 7 in Procedure Set 1.)