Dacor Microwave In-A-Drawer™ Flush Mount Installation Instructions
Important Safety Instructions
WARNING: If the information in this manual is not followed exactly, a fire or electrical shock may result that could cause property damage, personal injury or death.
- To reduce the risk of tipping, the Microwave In-A-Drawer™ must be secured by a properly installed anti-tip block.
- This drawer must be electrically grounded in accordance with local codes.
- Make sure the wall coverings and the cabinets around the drawer can withstand the heat generated by the microwave.
- Never leave children alone or unattended in the area where a microwave is in use. Never leave the drawer open when the microwave is unattended.
- Stepping, leaning or sitting on the drawer may result in serious injuries and can also cause damage to the Microwave In-A-Drawer™.
- Do not use the drawer as a storage space. Doing so creates a potentially hazardous situation.
- Check that the time-of-day is on the display. If not, touch STOP/CLEAR to prevent unintended use.
What You Need to Know About Safety Instructions
Warnings and Important Safety Instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur. Always use common sense, caution and care when installing, maintaining or operating this appliance. Always contact Dacor® about problems or conditions you do not understand.
Safety Symbols and Labels
- DANGER: Immediate hazards that WILL result in severe personal injury or death.
- WARNING: Hazards or unsafe practices that COULD result in severe personal injury or death.
- CAUTION: Hazards or unsafe practices that COULD result in minor personal injury or property damage.
Installer: Leave these instructions with the appliance.
Customer: Please read and keep these installation instructions for future reference. This guide provides proper installation information.
If you have any questions, call: Dacor Customer Service 1-800-793-0093 (U.S.A. and Canada) Monday - Friday 6:00 AM to 5:00 PM Pacific Time. Web site: www.Dacor.com
Have the complete model and serial number identification of your appliance ready. These numbers are found on a rating label, located on the faceplate behind the drawer front. See page 6.
Installation Requirements
The importance of the proper installation of your new appliance cannot be overemphasized. Installation should be done by a qualified installer.
Before you begin the installation process, read this entire installation instruction manual. It contains information necessary for proper, safe installation.
Any questions or problems with the installation should be directed to your Dacor dealer or the Dacor Customer Service Department at 800.793.0093. You can also visit our web site at www.Dacor.com.
Important Notes To The Installer
- Read all of the installation instructions before installing the Microwave In-A-Drawer™.
- Remove all packing material before connecting the electrical supply.
- Observe all governing codes and ordinances.
- Be sure to leave these instructions with the consumer.
Important Notes To The Consumer
Keep these instructions with your use & care manual for future reference.
- When using any microwave oven generating heat, there are certain safety precautions you should follow, that are listed in the use & care manual. Read the use and care manual and follow all safety precautions carefully.
- Be sure your Microwave In-A-Drawer™ is installed and grounded properly by a qualified installer or service technician.
For SAFETY CONSIDERATIONS do not install the drawer in any combustible cabinetry, which is not in accord with the stated clearances and dimensions on pages 3, 4 and 5. See Figure 2 (for 24") or Figures 4 and 5 (for 30").
Grounding Instructions
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
This appliance is equipped with a three-prong grounding plug for your protection against possible electric shock hazards. It must be plugged into a grounded wall receptacle. If only a two-prong wall receptacle is available, it is the responsibility of the customer to have it replaced with a properly grounded three-prong wall receptacle. Do not under any circumstances, cut or remove the third (ground) prong from the power cord. Do not use an adapter plug. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician or serviceman install an outlet near the appliance. Do not use a Ground Fault Circuit Interrupter.
Diagram Description: A power supply cord with a three-prong grounding plug is shown connecting to a grounding type wall receptacle (ground fault circuit not allowed).
24" Flush Mount Installation Instructions
Parts include:
Qty. | Part | DMR24M977WM/S |
---|---|---|
1 | Flush Mount Deflector Vent Stainless Steel | PREF-B019MRP0 |
2 | Mounting screws | LX-CZB055MRE0 |
1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.
Figure 1 Diagram Description: Shows a diagram of the cabinet opening with various dimensions labeled A through O. The note indicates the shelf face must sit 1 3/4" (44.45 mm) back from the cabinet face.
- A. 6" (152.40 mm)
- B. Suggested electrical outlet location
- C. Anti-Tip block
- D. 5" (127 mm)
- E. 3 1/2" (88.90 mm)
- F. 4" (101.60 mm)
- G. 24 3/16" (614.35 mm) minimum / 24 1/2" (622.3 mm) maximum
- H. 14 13/16" (376.24 mm) to bottom of Anti-Tip block
- I. 1 1/16" (26.97 mm)
- J. 23 1/2" (596.90 mm) minimum depth
- K. 22 1/8" (561.97 mm)
- L. 1 3/4" (44.45 mm)
- M. 16 7/8" (428.62 mm) opening
- N. Floor must support 100 lb (45.4 kg)
- O. 1 3/4" (44.45 mm)
Figure 2A Diagram Description: Shows a top view of the mounting cleat and anti-tip block placement relative to the drawer and cabinet face, with dimensions A through C. The note indicates the mounting surface of the finished cleat must sit 1 1/16" (26.97 mm) back from the face of the cabinet, pushing the face of the drawer out 1/4" (6.35 mm).
- A. 22" (558.8 mm) mounting cleat opening width
- B. 1/4" (6.35 mm)
- C. 1 1/16" (26.97 mm)
2. Install deflector as shown in Figure 3A.
Figure 3A & 3B Diagram Description: Illustrates the installation of the deflector vent onto the shelf, showing positioning, marking holes, pre-drilling, and the final installed state.
3. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet.
4. Carefully guide the drawer into the prepared opening. Avoid contact with the sides of the cutout opening and also pinching the cord between the oven and the wall.
5. Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening.
6. Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1/16" (1.57 mm) bit. See Figure 4.
Figure 4 Diagram Description: Shows the drawer open, with holes indicated for pre-drilling and the mounting flange.
7. Secure the drawer with the 4 screws supplied.
Figure 2B Diagram Description: Shows a front view of the cabinet opening with suggested electrical outlet location and anti-tip block, including dimensions A through C for the opening width and shelf height.
- A. 22 1/8" (561.97 mm) mounting cleat opening width
- B. 24 3/16" (614.35 mm) minimum / 24 1/2" (622.3 mm) maximum flush opening width
- C. 3/4" (19.05 mm) shelf
Figure 2C Diagram Description: Shows a side view illustrating the placement of the shelf, anti-tip block, and the relationship between the cabinet face and the shelf front face, including dimensions.
30" Flush Mount Installation Instructions
Parts include:
Qty. | Part | DMR30M977WM/S |
---|---|---|
1 | Flush Mount Deflector Vent Stainless Steel | PREF-B020MRP0 |
2 | Mounting screws | LX-CZB055MRE0 |
1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.
Figure 1 Diagram Description: Shows a diagram of the cabinet opening with various dimensions labeled A through O. The note indicates the shelf face must sit 1 3/4" (44.45 mm) back from the cabinet face.
- A. 6" (152.40 mm)
- B. Suggested electrical outlet location
- C. Anti-Tip block
- D. 5" (127 mm)
- E. 3 1/2" (88.90 mm)
- F. 4" (101.60 mm)
- G. 30 5/16" (769.92 mm) minimum / 30 5/8" (777.87 mm) maximum
- H. 14 13/16" (376.24 mm) to bottom of Anti-Tip block
- I. 1 1/16" (26.97 mm)
- J. 23 1/2" (596.90 mm) minimum depth
- K. 28 7/16" (722.3 mm)
- L. 1 3/4" (44.45 mm)
- M. 16 7/8" (428.62 mm) opening
- N. Floor must support 100 lb (45.4 kg)
- O. 1 3/4" (44.45 mm)
Figure 2A Diagram Description: Shows a top view of the mounting cleat and anti-tip block placement relative to the drawer and cabinet face, with dimensions A through C. The note indicates the mounting surface of the finished cleat must sit 1 1/16" (26.97 mm) back from the face of the cabinet, pushing the face of the drawer out 1/4" (6.35 mm).
- A. 28 1/2" (723.9 mm) mounting cleat opening width
- B. 1/4" (6.35 mm)
- C. 1 1/16" (26.97 mm)
2. Install deflector as shown in Figure 3A.
Figure 3A & 3B Diagram Description: Illustrates the installation of the deflector vent onto the shelf, showing positioning, marking holes, pre-drilling, and the final installed state.
3. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet.
4. Carefully guide the drawer into the prepared opening. Avoid contact with the sides of the cutout opening and also pinching the cord between the oven and the wall.
5. Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening.
6. Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1/16" (1.57 mm) bit. See Figure 4.
Figure 4 Diagram Description: Shows the drawer open, with holes indicated for pre-drilling and the mounting flange.
7. Secure the drawer with the 4 screws supplied.
Figure 2B Diagram Description: Shows a front view of the cabinet opening with suggested electrical outlet location and anti-tip block, including dimensions A through C for the opening width and shelf height.
- A. 28 7/16" (722.3 mm) mounting cleat opening width
- B. 30 5/16" (769.92 mm) minimum / 30 5/8" (777.87 mm) maximum flush opening width
- C. 3/4" (19.05 mm) shelf
Figure 2C Diagram Description: Shows a side view illustrating the placement of the shelf, anti-tip block, and the relationship between the cabinet face and the shelf front face, including dimensions.
Information You Need To Know
Model and Serial Number Location
The rating label includes the model and serial number. Open the microwave drawer fully. The label is located slightly beyond the back wall of the microwave cavity facing up from the flat surface.
Diagram Description: Illustrates the location of the rating label inside the microwave cavity.
Care, Cleaning and Maintenance
Refer to the use & care manual for cleaning instructions.
Before You Call for Service
Read the BEFORE YOU CALL and operating instruction sections in your use & care manual. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this microwave.
Refer to the warranty in your use & care manual for Dacor's toll-free service number and address. Please call or write if you have inquiries about your microwave product and/or need to order parts.