Fairland Full-Inverter Swimming Pool Heat Pump
Installation and User Manual
Thank you for choosing Fairland Full-inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent use.
For Users
Summary of Contents:
- 1. General Information (Page 3)
- 2. Operations (Page 6)
- 3. Technical Specification (Page 9)
1. General Information
1.1. Contents
After unpacking, please check if you have all the following components:
1.2. Operating Conditions and Range
Items | Air Temp | Range |
---|---|---|
Operating range | -7℃~43℃ | |
Temp. setting | heating | 18°C-40°C |
The heat pump will have ideal performance in the operation range Air 15℃~25℃.
1.3. Advantages of Different Modes
The heat pump has two modes: Smart and Silence. They have different advantages under different conditions.
Mode | Recommendation | Advantages |
---|---|---|
? Smart mode | As standard | Heating capacity: 20% to 100% capacity Intelligent optimization Fast heating |
? Silence mode | Use at night | Heating capacity: 20% to 80% capacity Sound level: 3dB (A) lower than Smart mode. |
1.4. Kind Reminder
⚠️ This heat pump has Power-off memory function. When the power is recovered, the heat pump will restart automatically.
- 1.4.1. The heat pump can only be used to heat pool water. It can NEVER be used to heat other flammable or turbid liquid.
- 1.4.2. Don't lift the water union when moving the heat pump, as the titanium heat exchanger inside the heat pump will be damaged.
Diagram showing lifting the heat pump by the water union, with a warning symbol.
- 1.4.3. Don't put obstacles before the air inlet and outlet of the heat pump.
Diagram showing obstacles blocking the air inlet and outlet of the heat pump.
- 1.4.4. Don't put anything into the inlet or outlet, or the efficiency of the heat pump will be reduced or even stopped.
- 1.4.5. Don't use or store combustible gas or liquid such as thinners, paint, and fuel to avoid fire.
Diagram showing cans of gas and paint near the heat pump, with a fire warning symbol.
- 1.4.6. If any abnormal circumstances occur (e.g., abnormal noises, smells, smokes, and leakage of electricity), switch off the main power immediately and contact your local dealer. Do not try to repair the heat pump by yourselves.
Diagram showing a hand switching off a power breaker, with a warning symbol.
- 1.4.7. The main power switch should be out of the reach of Children.
Diagram showing a power switch on a wall, with a warning symbol indicating it should be out of reach of children.
- 1.4.8. Please cut off the power in lightning storm weather.
Diagram showing a hand disconnecting a power plug during a lightning storm, with a warning symbol.
- 1.4.9. Please note that the following codes are not failures:
Codes | Description |
---|---|
E3 | No water flow |
Ed | Anti-Freezing Reminder |
Eb | Out of the operating range |
E6 | Insufficient water flow or pump blocked |
E5 | Power abnormal |
2. Operations
2.1. Notice Before Using
- 2.1.1. For longer service life, please ensure the water pump is on before the heat pump is on, and the water pump is off after the heat pump is off.
- 2.1.2. Ensure no water leakage on the piping system, then unlock the screen and press the power button ? to power on the heat pump.
2.2. Operation Instructions
Symbol | Designation | Function |
---|---|---|
? | ON/OFF | Power On/Off |
?/? | Lock/Unlock | Press it for 3 seconds to unlock/lock screen |
? | Speed | Select Smart/Silence mode |
▲/▼ | Up / Down | Adjust set temperature |
Note:
- Screen lock:
- If no operation in 30 seconds, the screen will be locked.
- When the heat pump (HP) is off, the screen will be dark and "0%" will be displayed.
- Press ? for 3 seconds to lock the screen, and it will be dark.
- Screen unlock:
- Press ? for 3 seconds to unlock the screen, and it will be lit up.
- Only after the screen is unlocked, any other buttons can be functioned.
Operation Steps:
- Power On: Press ? for 3 seconds to light up the screen, then press ? to power on the heat pump.
- Adjust Set Temperature: When the screen is unlocked, press ▲ or ▼ to display or adjust the set temperature.
- Smart/Silence Mode Selection:
- Smart mode is activated by default when the heat pump is on, and the screen shows ?.
- Press ? to enter Silence mode, and the screen shows ?. (Suggestion: select Smart mode for initial heating.)
4. Defrosting
- a. Auto Defrosting: When the heat pump is defrosting, the ❄️ symbol will be flashing. After defrosting, the ❄️ symbol will stop flashing.
- b. Compulsory Defrosting: When the heat pump is heating after 10 minutes, press ? and ▲ together for 5 seconds to start compulsory defrosting, and the ❄️ symbol will be flashing. After defrosting, the ❄️ symbol will stop flashing. (Note: Compulsory defrosting intervals should be more than 30 minutes, and the compressor should run for more than 10 minutes.)
5. Wifi Setting
Please kindly check the last page for Wi-Fi settings.
2.3. Daily Maintenance and Winterizing
2.3.1. Daily Maintenance
⚠️ Please don't forget to cut off power supply of the heat pump.
- Please clean the evaporator with household detergents or clean water. NEVER use gasoline, thinners, or any similar fuel.
- Check bolts, cables, and connections regularly.
2.3.2. Winterizing
In winter season when you don't swim, please cut off power supply and drain water out of the heat pump. When using the heat pump under 2℃, make sure there is always water flow.
❗Important: Unscrew the water union of the inlet pipe to let the water flow out. When the water in the machine freezes in winter season, the titanium heat exchanger may be damaged.
3. Troubleshooting for Common Faults
Failure | Reason | Solution |
---|---|---|
Heat pump doesn't run | No power | Wait until the power recovers |
Power switch is off | Switch on the power | |
Fuse burned | Check and change the fuse | |
The breaker is off | Check and turn on the breaker | |
Fan running but with insufficient heating | Evaporator blocked | Remove the obstacles |
Air outlet blocked | Remove the obstacles | |
Display normal, but no heating | 3 minutes start delay | Wait patiently |
Set temp. too low | Set proper heating temp. |
ATTENTION! Please don't try to repair the heat pump by yourself to avoid any risk.
4. Failure Codes
Non-Failure Codes:
NO. | Display | Not failure description |
---|---|---|
1 | E3 | No water protection |
2 | E5 | Power supply excesses operation range |
3 | E6 | Excessive temp difference between inlet and outlet water (Insufficient water flow protection) |
4 | Eb | Ambient temperature too high or too low protection |
5 | Ed | Anti-freezing reminder |
Failure Codes:
NO. | Display | Failure description |
---|---|---|
1 | E1 | High pressure protection |
2 | E2 | Low pressure protection |
3 | E4 | 3 phase sequence protection (three phase only) |
4 | E7 | Water outlet temp too high or too low protection |
5 | E8 | High exhaust temp protection |
6 | EA | Evaporator overheat protection (only at cooling mode) |
7 | P0 | Controller communication failure |
8 | P1 | Water inlet temp sensor failure |
9 | P2 | Water outlet temp sensor failure |
10 | P3 | Gas exhaust temp sensor failure |
11 | P4 | Evaporator coil pipe temp sensor failure |
12 | P5 | Gas return temp sensor failure |
13 | P6 | Cooling coil pipe temp sensor failure |
14 | P7 | Ambient temp sensor failure |
15 | P8 | Cooling plate sensor failure |
16 | P9 | Current sensor failure |
17 | PA | Restart memory failure |
18 | F1 | Compressor drive module failure |
19 | F2 | PFC module failure |
20 | F3 | Compressor start failure |
21 | F4 | Compressor running failure |
22 | F5 | Inverter board over current protection |
23 | F6 | Inverter board overheat protection |
24 | F7 | Current protection |
25 | F8 | Cooling plate overheat protection |
26 | F9 | Fan motor failure |
27 | Fb | Power filter plate No-power protection |
28 | FA | PFC module over current protection |
Appendix 1: Wiring Diagram for External Control (Optional)
5. Wifi Setting
1) APP Download
Android mobile please download from Google Play.
iPhone please download from App Store.
2) Account Registration
a) Registration by Cell phone number/Email
b) Cell phone number registration
3) Create Family
Please set family name and choose the room of the device.
4) APP Binding
Please make sure your cell phone has connected the Wifi.
a) Wifi connection:
Press ? for 3 seconds after screen unlock; the ? symbol will be flashing to enter the Wifi binding program.
b) Click "Add device", follow indication to finish binding. ? display on the screen once Wifi connection success.
c) If connect fails, please make sure your network name and password is correct. And your router, mobile phone, and device are as close as possible.
d) Wifi rebinding (When Wifi password changes or network configuration changes):
Press ? for 10 seconds; the ? will be flashing slowly for 60 seconds. Then the ? will be off. The original binding will be removed. Follow the step above for rebinding. Remarks: Please make sure the router is configured at 2.4G.
5) Operation
a) For heat pump with Heating function only
6) Share Devices to Your Family Members
After binding, if your family members also want to control the device, please let your family members register the APP first, and then the administrator can operate as below:
Notice: 1. The weather forecast is just for reference. 2. APP is subject to updating without notice.