Owner's Manual for MEAN WELL models including: NDR-120-12 Series 120W Single Output Industrial DIN RAIL, NDR-120-12 Series, 120W Single Output Industrial DIN RAIL, Single Output Industrial DIN RAIL, Output Industrial DIN RAIL, Industrial DIN RAIL

NDR-120-24 ab 35.65 EUR - Radiomag GmbH Hersteller: Mean-Well USA, Inc. AC/DC Power Supply Single-OUT 24V 5A 120W 7-Pin

NDR-120-24 Mean Well від 1240 грн - РАДИОМАГ РКС КОМПОНЕНТЫ


File Info : application/pdf, 4 Pages, 668.06KB

PDF preview unavailable. Download the PDF instead.

ndr-120-spec
120W Single Output Industrial DIN RAIL

NDR-120 series
User's Manual

   

     

Bauar t gepruft Sicherheit
egelma ge od o s be wac g www.tuv.com ID 2000000000
TPTC004 BS EN/EN62368-1 IEC62368-1
     
 
 

 
                                                               

     

  

File Name:NDR-120-SPEC 2022-09-20

Downloaded from Arrow.com.

120W Single Output Industrial DIN RAIL

NDR-120 series

SPECIFICATION

MODEL

NDR-120-12

NDR-120-24

NDR-120-48

DC VOLTAGE

12V

24V

48V

RATED CURRENT

10A

5A

2.5A

CURRENT RANGE

0 ~ 10A

0 ~ 5A

0 ~ 2.5A

RATED POWER

120W

120W

120W

RIPPLE & NOISE (max.) Note.2 100mVp-p

120mVp-p

150mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

12 ~ 14V

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±1.0%

24 ~ 28V ±1.0% ±0.5% ±1.0%

48 ~ 55V ±1.0% ±0.5% ±1.0%

SETUP, RISE TIME

1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC 10ms/115VAC at full load

VOLTAGE RANGE Note.6 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

85.5%

88%

89%

INPUT AC CURRENT (Typ.)

2.25A/115VAC 1.3A/230VAC

INRUSH CURRENT (Typ.) 20A/115VAC 35A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

OVERLOAD

105 ~ 130% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE

14 ~ 17V

29 ~ 33V

Protection type : Shut down o/p voltage, re-power on to recover

56 ~ 65V

OVER TEMPERATURE

Shut down o/p voltage, re-power on to recover

WORKING TEMP.

-20 ~ +70 (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 95% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

SAFETY STANDARDS

UL508, TUV BS EN/EN62368-1, EAC TP TC 004 approved;(meet BS EN/EN60204-1)

SAFETY & WITHSTAND VOLTAGE

EMC

ISOLATION RESISTANCE

(Note 4) EMC EMISSION

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020

MTBF

2636.8K hrs min. Telcordia SR-332 (Bellcore) ; 453.3K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

40*125.2*113.5mm (W*H*D)

PACKING

0.6Kg; 20pcs/13Kg/1.16CUFT

NOTE





 













https://www.meanwell.com/serviceDisclaimer.aspx

File Name:NDR-120-SPEC 2022-09-20

Downloaded from Arrow.com.

120W Single Output Industrial DIN RAIL

NDR-120 series

Block Diagram

EMI FILTER

I/P

&

RECTIFIERS

FG

O.L.P. O.T.P.

POWER SWITCHING
PWM CONTROL

RECTIFIERS &
FILTER

O.C.P.
DETECTION CIRCUIT
O.V.P.

fosc : 70KHz
+V -V

Derating Curve

Static Characteristics

230VAC 100
80 115VAC
60 50 40
20

12V,24V,48V
12V (115VAC only)

-20 -10 0

10

20

30

40 45 50

60 70 (VERTICAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40
90 100 125 135 145 155 165 175 180 200 230 264
INPUT VOLTAGE (V) 60Hz

LOAD (%) LOAD (%)

Downloaded from Arrow.com.

File Name:NDR-120-SPEC 2022-09-20

120W Single Output Industrial DIN RAIL
Mechanical Specification

NDR-120 series
Case No.992D Unit:mm

35 125.2

113.5 Side View
Installation Instruction

Top View 40
1234
TB2 +V ADJ. +
DC OK
TB1 123 Front View
Bottom View

Side View
Terminal Pin No. Assignment (TB1) Pin No. Assignment 1 FG 2 AC/N or DC 3 AC/L or DC +
Terminal Pin No. Assignment (TB2) Pin No. Assignment 1,2 DC OUTPUT -V 3,4 DC OUTPUT+V

35

This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual.
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
(For reference only. Not included with unit.)

Back View
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Downloaded from Arrow.com.

File Name:NDR-120-SPEC 2022-09-20



References

iText 5.5.6 ©2000-2015 iText Group NV (AGPL-version)