User Guide for LINOVISION models including: POE-SWR608G Web Management, POE-SWR608G, Web Management, Management

SF05 空

WEB Management Manual

Industrial 8 Ports Full Gigabit PoE Switch Support Remote PoE Ports Management | Linovision Europe Store

Industrial 8 Ports Full Gigabit PoE Switch with Remote PoE Ports Manag

PDF preview unavailable. Download the PDF instead.

POE-SWR608G WEB Management Manual-v1.6 ?v=1713411332
WEB Management Manual
Web Smart Series Switch Document Version : v1.6

Copyright notice
Disclaimers
Preface Reader object
This document is suitable for the following people  Network Engineer  Technical Promotion Personnel  Network Administrator
Agreement in this book 1. Command line format Convention The meaning of the command line format is as follows: Bold: the command line keywords (the parts that must be input as they remain unchanged in the command) are expressed in bold font. Italics: command line parameters (parts of the command that must be replaced by actual values) are expressed in italics. []: indicates the part enclosed by [], which is optional during command configuration. { x | y | ... } Indicates that one of two or more options is selected. [ x | y | ... ] Indicates to select one or none of two or more options. //: a line starting with a double slash is represented as a comment line.
2. Description  Some port types illustrated in this manual may be inconsistent with the actual situation.
In actual operation, it is necessary to configure according to the port types supported by each product.  The display information illustrated in this manual may contain the contents of other product series (such as product model, description, etc.), and the specific display information shall be subject to the actual equipment information.

Web Smart Function Configuration
1. Overview
Web Smart refers to the device web management system, that is, the web management system that manages or configures the device, and manages the device by accessing Web Smart using a browser (such as Chrome). Web management includes two parts: Web server and Web client. The Web server is integrated on the device to receive and process the requests sent by the client and return the processing results to the client. The Web client usually refers to the browser, such as Chrome, IE and FF.
2. Configuration Guide
This section provides an introduction to the web-based configuration utility, and covers the following topics: · Powering on the device · Connecting to the network · Starting the web-based configuration utility
2.1. Power
Connecting to Power
Power down and disconnect the power cord before servicing or wiring a switch.
Do not disconnect modules or cabling unless the power is first switched off. The device only supports the voltage outlined in the type plate. Do not use any other power components except those specifically designated for the switch. Disconnect the power cord before installation or cable wiring.
Connect the AC power connector on the back panel of the switch to the external power source with the included power cord, and check the power LED is on.

2.2. Connecting to the Network
To connect the switch to the network: 1. Connect an Ethernet cable to the Ethernet port of a computer 2. Connect the other end of the Ethernet cable to one of the numbered Ethernet ports of the switch. The LED of the port lights if the device connected is active. 3. Repeat Step 1 and Step 2 for each device to connect to the switch.
We strongly recommend using CAT-5E or better cable to connect network devices. When connecting network devices, do not exceed the maximum cabling distance of 100 meters (328 feet). It can take up to one minute for attached devices or the LAN to be operational after it is connected. This is normal behavior.
Connect the switch to end nodes using a standard Cat 5/5e Ethernet cable (UTP/STP) to connect the switch to end nodes as shown in the illustration below. Switch ports will automatically adjust to the characteristics (MDI/MDI-X, speed, duplex) of the device to which the switch is connected.
2.3. Starting the Web-based Configuration Utility
This section describes how to navigate the web-based switch configuration utility. Be sure to disable any pop-up blocker.
Launching the Configuration Utility To open the web-based configuration utility: 1. Open a Web browser. 2. Enter the IP address of the device you are configuring in the address bar on the browser (factory default IP address is 192.168.2.1) and then press Enter.
After a successful connection, the login window displays.

2.4. Logging In
The default username is admin and the default password is admin. To log in to the device configuration utility: 1. Enter the default user ID (admin) and the default password (admin). 2. If this is the first time that you logged on with the default user ID (admin) and the default password (admin) it is recommended that you change your password immediately. When the login attempt is successful, the System Information window displays.
If you entered an incorrect username or password, an error message appears and the Login page remains displayed on the window. By default, the application logs out after five minutes of inactivity. To logout, click Logout in the top right corner of any page. The system logs out of the device. When a timeout occurs or you intentionally log out of the system, a message appears and the Login page appears, with a message indicating the logged-out state. After you log in, the application returns to the initial page.
2.5. Web-based Switch Configuration
The WebSmart switch software provides Layer 2 functionality for switches in your networks. This chapter describes how to use the web-based management interface (Web UI) to configure the switch's features. For the purposes of this manual, the user interface is separated into three sections, as shown in the following figure:

As you can see, the page is divided into two parts: The left part is the menu bar, which displays the links of all configuration functions of the equipment, such as monitoring management and switch configuration module. The right part is the content area, which is divided into upper and lower parts. The upper side is the port status bar, Chinese and English display switching and Logout button, and the lower side is the page content presentation and configuration area.
Port Status Bar: Move the mouse to the port to display the basic status of the port (including port connection status, rate duplex and flow control status). Click Collapseto hide the port status bar and display more content areas to view other configuration information.

When a loop appears on the port, the port icon displays yellow
When the port works normally, the port icon displays green
The content area sometimes presents orange text (indicating the description of the function block)
3. Web Smart Configuration
3.1. Homepage
The homepage interface displays the basic information of the device.

3.2. System Settings
3.2.1. Device Info Configure the information of the device, including Device Name, Device Contact and Device Location.
3.2.2. IP Settings Configure device management IP (default static IP: 192.168.2.1)
When "Auto Obtain IP" is displayed as follows:
Tips: 1. When configuring IP, the device will be disconnected briefly. If automatic IP acquisition is enabled, you need to obtain the configuration IP from the uplink device or web management through device management IP: 10.XX.XX.XX(XX.XX.XX is the last two digits of the MAC address of the current device).
3.2.3. WEB Settings Configure web page timeout, default is 5 minutes.

Tips: 1. The timeout can be configured for 1-60 minutes
3.2.4. Telnet Settings Configure Telnet timeout, default is 10 minutes.
Tips: 1. The timeout can be configured for 1-60 minutes
3.2.5. User Management Configure the account and password for web page login (The password must contain 6-16 characters and contain only letters, numbers and the following special characters: <=>[]!@#$*().)
3.2.6. Upgrade System upgrade can be divided into Local upgrade and Online upgrade: 1. Local upgrade ClickSelect Fileand select the software package you want to upgrade in the pop-up file selection box (the software upgrade package is a file in xxx.bin format).
2. Online upgrade If there is an uploaded version at the remote sever, enter the firmware name and the domain name or IP address of the server address, click theUpgradebutton and confirm. The device will download the firmware version from the remote sever and upgrade to this version (The online upgrade time depends on the current network fluency, please wait patiently).

3.2.7. Device Management ClickRebootto restart the equipment. ClickRestoreto restore the factory configuration and restart the equipment. ClickSave Configureto save current device configure.
3.3. Monitoring
3.3.1. Port Statistics The Port Statistics page displays the data statistics and status of the device port, such as the port sending and receiving rate, sending and receiving packets, etc.
3.3.2. Cable Diagnostics

You can roughly understand the cable condition of the corresponding port through cable detection (such as whether the cable is short circuited, disconnected, etc.). Click Start All and wait for the test results to return.
3.3.3. Loop Guard

Configure enable loop guard
Tips: The port causing the loop will be shut down. After the loop is removed, the port will be up automatically.Default is disable.
3.3.4. IGMP Snooping Configure IGMP Snooping
Unknown multicast Handel Action can configure FLOOD or DROP, Select the VLAN you want to enable and click Apply to save. Tips: IGMP Snooping only supports DIP mode, the maximum multicast entry is 10, Unknown multicast Handel Action default is flood.
3.4. Switch Settings
3.4.1. Port Settings Port configuration can batch configure the status, speed, duplex, flow control and EEE properties of ports. The page is divided into two parts: Configuration part: Select the port to be configured, then select each attribute to be configured, and click Apply to distribute the configuration.

Display part: Displays the configuration attributes and actual effective attributes of each port of the device.
3.4.2. Port Mirroring The input / output messages of one or more source image ports are forwarded to the destination image port to monitor the network.
Tips: 1. Source port and destination port cannot be the same 2. Another mirror group is using the destination port 3. Supports 4 Session IDs 3.4.3. Port Isolation

Configure isolation port group
3.4.4. Jumbo frame Configure the size of Jumbo Frames that can be forwarded.
Tips 1. Jumbo Frames can be configured with 1522, 1536, 1552, 9216 and 10000; 2. The default value of Jumbo Frames is 1522. 3.4.5. Green Enable
3.4.6. Static MAC The static MAC configuration is divided into two parts. Static MAC add: Enter the legitimate MAC address, VLAN ID, and select the configured port number. Click Add to add static MAC.
Static MAC deletion and display: After adding a legal static Mac, the corresponding data will be displayed; Check the static Mac and clickDelete. After the configuration is successful, the MAC address, VLAN and corresponding port will be unbound.

Tips: 1. Static MAC addresses maximum can be configured 16. 3.4.7. Filter MAC Configure filtered MAC address
Tips: 1. Filter MAC addresses maximum can be configured 16.
3.4.8. Search MAC Search the MAC table learned by the device (support fuzzy search?)
Tips: 1. The inquiry waiting process will interrupt the communication with the equipment
3.4.9. MAC List Displays the list of MAC learned by the device

ClickClear Dynamic MACand the device will get the learning MAC list again.
Tips: 1. The display waiting process will interrupt communication with the device
3.4.10. DHCP Snooping Configure DHCP Snooping function, which is disabled by default.
When DHCP Snooping is enabled, you can choose to trust ports or not. As shown in the following figure, the device sets the selected ports as trusted ports, and if it is not selected, all ports are untrusted ports; ClickApplyto set the selected port as a trusted port and complete the configuration of DHCP snooping.
Tips: 1. Enable DHCP snooping to filter DHCP messages. For the request message from DHCP client, only forward it to the trust port; for the response message from DHCP server, only forward the response message from the trust port. 2. Generally, the DHCP server port (upper connection port) is set as the trust port.

3.5. VLAN Settings
Add or delete device VLAN members and port VLAN configuration 3.5.1. VLAN Member Configuration part: Enter a valid VLAN ID and click Applyto configure a new VLAN member;
Display part: Displays the VLAN members newly added by the device, Select VLAN members in the VLAN member list and clickDeleteto delete VLAN members in batch
Tips: 1. Configure up to 16 VLAN members; 2. When VLAN ID is bound by port, it cannot be deleted. 3.5.2. VLAN Settings Port VLAN configuration is divided into two parts: Part I: Port VLAN configuration, select port, VLAN type (access and trunk, allow VLAN can be configured under trunk), allow VLAN and native VLAN, and clickApplyto configure and save port VLAN (Permit VLAN and Native VLAN are selected from the VLAN members configured above);
Part II: Port VLAN list, which displays the VLAN configuration of the device port. Tips: the message under Native VLAN does not have VLAN tag.

3.6. QoS Settings
Including port rate limit and storm control functions.
3.6.1. Port Rate Configure the port ingress and egress rate, which is divided into two parts: Configuration part: Select one or more ports, select the configuration type and whether to enable the port speed limit (enter the value of the port speed limit when it is enabled), and clickApply to configure the port rate.
Display part: displays the ingress rate and egress rate of the device port configuration.

Tips: 1. Rate limit range: 1-1000M
3.6.2. Storm Control Including port storm control configuration and display: Configuration part: Select the configured storm control type, one or more ports and whether to enable storm control (when enabled, enter the rate of storm control configuration), and clickApply to configure storm control.
Display part: Display the storm control type and corresponding rate configured by the device port (display the corresponding control rate when it is turned on).

Tips: 1. Rate limit range: 1-1000M
3.6.3. QoS Property Including QoS Property configuration and display Configuration part Select the configured Enable State, Queue Scheduling Mode, Priority Type and Weightand clickApplyconfigure QoS Property.
Display part Display the Enable State, Queue Scheduling Mode, Weighting of COS and DSCP
Tips 1. The QoS function is disabled by default; 2. The Queue Scheduling mode supports SP and WRR; 3. The priority type supports COS and DSCP; 4. Priority types with higher weights have higher priorities. When the weights are the same, COS have higher priority.

3.6.4. COS Priority Mapping Including configuration and display Configuration part Select the configured COS Priority and Inner Priorityand clickApplyconfigure.
Display part Display the COS Priority and Inner Priority.
Tips 1. The default COS priority corresponds to the internal priority 0-7 in turn. 3.6.5. DSCP Priority Mapping Including configuration and display Configuration part Select the configured DSCP Priority Mapping and Inner Priorityand clickApplyconfigure.
Display part Display the DSCP Priority Mapping and Inner Priority.
Tips

1. Default DSCP priority 0-7 corresponds to internal priority 0, 8-15 corresponds to internal priority 1, and so on. 3.6.6. Inner Priority Mapping Including configuration and display Configuration part Select the configured Inner Priority and Queue ID, and clickApplyconfigure.
Display part Display the Inner Priority and Queue ID.
Tips 1. Default internal priority 0-7 corresponds to queue ID 0-7.
3.6.7. Queue Scheduling Including configuration and display Configuration part Select the configured Queue ID and Weight, and clickApplyconfigure.
Display part Display the Queue ID and Weight
When the queue scheduling mode is SP, the weight cannot be set. The default weight of the

eight queues is 1.
Tips 1. When the queue scheduling mode is WRR, 0-7 of the queue ID corresponds to 1-8 of the weight by default.
3.7. PoE Settings
Tips: Some models support Poe function 3.7.1. PoE Global Info Displays the global information of the device Poe function
3.7.2. PoE Basic settings

Includes port PoE configuration and display: Configuration part: Select the PoE power supply status, priority and limited power of the configured port, and click Apply to configure PoE.
Display part: Display the power of port PoE and the current power supply status;
Tips: 1. Disable port Poe. Port Poe will not be powered. 3.7.3. PD Alive Includes PD Alive configuration and display: Configuration part: Configure the detection time of PD Alive (60-86400s. When no communication is detected on the port, PoE will be restarted automatically). ClickApplyto configure PD alive.

Display part: Displays the number of restarts of device PD Alive.
3.8. Onvif
Support Onvif protocol function to discover devices ClickDetectto find the device.
4. Frequently Asked Questions
Question 1: unable to log in to the device manager web management interface. What

should I do? Refer to the following steps:
1) Confirm that the PC network cable is normally connected to the device port, and the corresponding indicator flashes.
2) Before accessing the setting interface, it is recommended to set the computer to "static IP mode" and configure it to 10.224.0.XX (e.g. 10.224.0.121, which cannot be consistent with the device configuration IP 10.XX.XX.XX (XX.XX.XX is the last two digits of the MAC address of the current device)), subnet mask: 255.0.0.0.
3) Use the ping command to detect the connectivity between the computer and the device.
Question 2: what if you forget your device user name and password? How to restore the factory configuration? If you forget the login password, long press the reset key on the panel for 5 seconds when the device is powered on, and the device will be restored to the factory setting after restarting


WPS 文字