TROUBLESHOOTING GUIDE

Service Run Time Indicator
Solid red light means service is required When the unit has reached approximately 9,000 hours of runtime, a solid RED service light should appear and remain on until service has been performed. · Service light appears at 9,000 hours · Service light will not stop ozone production · Service light must be manually reset by user
NOTE: Service will be required at 9,000 hours of runtime
Power Light Does Not Illuminate
If power indicator light does not illuminate on right side of unit, try these steps: · Verify the unit has power · Press the Mode Select button to see if the unit will cycle through different modes · Unplug the unit, remove cover and confirm that the main power wires at the
control board are seated securely. If the connection is loose, disconnect the wires fully and reseat the connection.
NOTE: Confirm power if no lights are present
No Bubbles from Diffuser
If bubbles do not come out of diffuser, try these steps: · Make sure that the indicator LED is blinking. If the light is "ON," but not blinking, the
unit is in standby. Wait for 10 minutes for another ozone cycle to occur. · Clean the diffuser (see servicing for details) · Confirm compressor is energized during an ozone cycle · Check all tubing and fitting connections for possible leaks · Confirm wired connection between compressor and control board is seated correctly
NOTE: If no bubbles, wait 10 minutes for next ozone cycle

Ozone Smell Around Ice Machine
If there is a strong ozone smell present around the ice machine, try this step:
· Adjust the run time setting down by pressing the Mode Select button repeatedly, cycling through each of the modes.

Biofilm Buildup in Ice Machine
If biofilm builds up quickly in the ice machine, try this step:
· Adjust the run time setting up by pressing the Mode Select button repeatedly, cycling through each of the modes.

LIGHT COLOR
OFF YELLOW GREEN
BLUE PURPLE
RED

NUMBER OF BLINKS
1 2 3 4

24 HOUR ICE YIELD, NORMAL ENVIRONMENT
< 400 lbs 182 KG kgs 400-600 lbs 182-273 kgs 600-1000 lbs 273-455 kgs < 1000+ lbs 455+ kgs

24 HOUR ICE YIELD, EXTREME ENVIRONMENT*

AIR FLOW (SCFH)

OFF

NA

0.5 14 L/h

< 400 lbs < 182 kgs

1.0 28.3 L/h

400-600 lbs 182-273 kgs

1.5 42 L/h

< 260+ lbs < 273+ kgs

2.0 56.6 L/h

SERVICE REQUIRED

NOTE: Adjust to lower run time if ozone is present around ice machine Adjust to higher run time if biofilm is building up in ice machine

REPEATING RUN TIME (MINUTES)
1 On / 9 Off 2 On / 8 Off 4 On / 6 Off 7 On / 3 Off

Abnormal Noises from Compressor
If the compressor sounds abnormal or becomes louder than normal, try these steps:
· Remove the cover and confirm the compressor's mounting hardware is tight and secure
· Ensure nothing is resting again the compressor that increases the noise
· Make sure the diaphragms on both sides of the compressor are not worn or torn
NOTE: Confirm power if no lights are present

Consider These Products with Oxidice

Nickel-Safe Ice Machine Cleaner

Liquid Ice Machine Cleaner

IMS-III Sanitizing Concentrate
2611 Schuetz Rd. · St. Louis, MO 63043 · 800-554-5499 · www.nucalgon.com · Calgon is a licensed trade name. (0323) 3-171

