User Manual for zencontrol models including: ZC-SS, Smart Switch, ZC-SS Smart Switch, Switch
Smart switch with six buttons | zencontrol
26 set 2022 — This product must only be installed by a licensed electrician. □ Before commencing installation turn off and isolate the electrical supply.
File Info : application/pdf, 2 Pages, 885.91KB
DocumentDocumentSmart switch zc-ss Dimensions Fixing centres 84 mm Dimensions W75 / H117 / D34 mm 116 84 Product range Order code zc-ss-1sw-blk zc-ss-1sw-wht zc-ss-2sw-blk zc-ss-2sw-wht zc-ss-3sw-blk zc-ss-3sw-wht zc-ss-6sw-blk zc-ss-6sw-wht Description Smart switch with 1 button to suit 84 mm wall mount, black Smart switch with 1 button to suit 84 mm wall mount, white Smart switch with 2 buttons to suit 84 mm wall mount, black Smart switch with 2 buttons to suit 84 mm wall mount, white Smart switch with 3 buttons to suit 84 mm wall mount, black Smart switch with 3 buttons to suit 84 mm wall mount, white Smart switch with 6 buttons to suit 84 mm wall mount, black Smart switch with 6 buttons to suit 84 mm wall mount, white Specifications Supply Supply current Control system Radio support Frequency band Max radio tx power DALI line current Wiring Operating temperature Material Ingress protection 220 - 240 V ~ 50Hz 4 mA Wired DALI-2Wireless IEC62386-104 over Thread IEEE 802.15.4 2.4 GHz +8 dBm 2 mA 1 - 4 mm2 Strip 8 - 10 mm 0 to 55°C PC UV stabilised, toughened glass, aluminium IP20 Safety information This product must only be installed by a licensed electrician. Before commencing installation turn off and isolate the electrical supply. There are no user serviceable parts, attempting to service any part of the product will void the warranty DALI is not SELV and as such should be treated as LV. As the installer, it is your responsibility to ensure you comply to all relevant building and safety codes. Refer to applicable standards for the relevant rules. Isolate electrical supply before removing faceplate. Circuit-board is NOT isolated. 75 9.5 18.5 6 c-clip System overview: modes 1 104 mode is enabled after the device has been added to a 104 application controller such as zc-iot-fc. Wirezlce-ssss-sswwitch IIEECC6622338866--330011 zc-iot-fc IEC 62386-103 IEC 62386-104 over Thread 2 104 + 101 Bridge mode is enabled after the device has been added to a 104 controller and a 101 power supply has been connected to the DALI terminals. PIR sensor IEC 62386-303 zc-psu-70 IEC 62386-101 Wirezlce-ssss-sswwitch IIEECC6622338866--330011 IEC 62386-101 IEC 62386-104 over Thread zc-iot-fc IEC 62386-103 DALI luminaire IEC 62386-102 3 101 mode is enabled after a 101 power supply has been connected to the DALI terminal and the device has not been added to a 104 application controller. Wirezlecs-ssss-swwitch IEIECC6622338866-3-30011 Power supply IEC 62386-101 Application controller IEC 62386-103 LN DA DA IEC 62386-101 Ethernet 0553501_V 1.0 Last updated 23 / 09 / 22 Information is subject to change without notice, E&OE Installation Remove the product from the box and inspect it for any damage. If you believe the product to be damaged or otherwise unsound, do not install the product. Please pack it back into its box and return it to the place of purchase for replacement. If the product is satisfactory, proceed with the installation: 1 Ensure safety warnings are adhered to. 2 Optional: Connect the two DALI terminals to the DALI line ensuring wiring regulations are followed. DALI is not polarised. DALI is not SELV and as such must be treated as LV. Do not connect DALI to any mains voltages. 3 Remove front plate by inserting a screwdriver (min. 5.5pt) into receptacle at the bottom of the frame. Twist left, twist right, to release cover, do not lever. 4 Cut-out the hole, insert wallbox if applicable. 5 Insert provided screws into frame and attach to pre-mounted wallbox/c-clip (not included). 6 Latch cover on top of frame to clip base back into frame, attached on the wall. 3 Wiring diagram Input configuration L N DA 2 Optional DA Wire preparation L N DADA 4 mm Ensure each terminal is lined up with correct marking on the product label Configuration By default the device is configured with 1/2/3 control device instances with LED indicator. Actual function is dependant on the configuration of a DALI-2 application controllers connected to the DALI line, or the Wireless application controller. By default the device will configure its mode of operation depending on what has been commissioned. C-Clip (not included) 5 6 Clip in at top ECD operating mode 128 (0x80) Bridge mode (default): Device acts as a bridge between Thread 104 interface and DALI devices connected via 101 interface 129 (0x81) Beacon mode: Device broadcasts Bluetooth beacons and communicates via 104 interface if Thread network is commissioned otherwise via 101 interface. For more information on how to configure Beacons visit support. zencontrol.com 130 (0x82) Bridge disabled: Device communicates via both 104+101 interface, however, bridge mode is disabled (i.e. Devices connected on the 101 interface will not be available on the Thread 104 system) 4 Cut-out 56 x 75 mm Frame Tab must face down Base Notice For more information on compliant software see our website zencontrol.com zencontrol.com © zencontrol