Instruction Manual for MOLLET models including: Vibro Level Indicators, Vibro Indicators, Level Indicators, Indicators
MOLOSvibro VF63 senzor podaljška palice MOLLLET - ELPRO
MOLOSvibro VF65 senzor za vzmetni kabel MOLLET - ELPRO
VF65 MOLOSvibro senzor za vzmetni kabel MOLLET
File Info : application/pdf, 6 Pages, 260.92KB
DocumentDocumentM LLET Füllstandtechnik Vibro level indicators Level limit switches for bulk goods GmbH VF6. Dust Explosion protection information and supplement to the operating instructions Prior to the use of the device in potentially explosive atmospheres please, read and obey the special conditions and instructions for safe application on page VF6-EID-05. Please observe rules for maximum allowed ambient temperatures shown on page VF6-EID-04. Type plate details with option B1 Dust Model designation Unique device serial number Order number Manufacturer and address CE sign with the number of the "Notified Body" which is involved in the production control phase EU-type examination certificate number GmbH 0044 M LLET Füllstandtechnik Industriepark RIO 103 D-74706 Osterburken Tel. +49 62 91 64 400 IBExU19ATEX1052 IP66/IP67 Typ VF6...B1... W II 1/2D Ex ta/tb IIIC T95°C Da/Db Supply 20...250 V AC/DC S# 1234567890 A.- Nr. 1234567890 03/19 -20°CTa+80/+60°C Consumption 3 VA p (Process) -0,95bar...+10,0bar Contact 5 A / 250 V AC~ Type of protection Details to supply voltage and current consumption Month and year of delivery DustEx identification Details to loadability of the signal contact Ambient temperature (process temperature) Design of the devices suitable for pressures in the vessel indicated here. M LLET Competence in explosion protection MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 www.mollet.de Explosion protection information 06/21 © by MOLLET VF6-EID-01 01 M LLET Füllstandtechnik GmbH Vibro level indicator VF6. Marking in accordance with ATEX and DIN EN IEC 60079-0 Vibro level indicator for use at the boundary from zone 20 to zone 21. W II 1/2 D Ex ta/tb IIIC T95°C Da/Db Equivalent to valid ATEX-Product-Directive Equipment group II = everything except mining Equipment category Category 1 for zone 20, 21 and 22 Category 2 for zone 21 and 22 / = Level indicators, which are installed on the boundary between different zones Type of explosive atmosphere D = Dust the Ex symbol according to DIN EN IEC 60079-0 t = Protection by enclosure a = Device with ,,very high" protection standard . . . . for zone 20, 21 and 22 b = Device with ,,high" protection standard . . . . . . . . for zone 21,and 22 IIIC for flammable conductive dust, flammable non-conductive dust and flammable fibres and flyings T..°C maximum surface temperature Type of explosive atmosphere D = Dust a = Device with "very high level of protection" for use in potentially explosive atmospheres where in normal operation, foreseeable or infrequent faults/malfunctions no ignition hazard is given. b = Device with "high level of protection" for use in potentially explosive atmospheres where in normal operation or foreseeable faults/malfunctions no ignition hazard is given. Order code VF62A1B1... and VF63A1B1... Marking: II 1 / 2 D Dust Equipment category appropriation by zones Vibro level indicator for use at the boundary from zone 20 to zone 21. T 95°C VF63 Ambient temperatures Ta The ambient temperature Ta defines the maximum operating temperature of the indicators. Inside the vessel this is process temperature (the air or the bulk goods temperature) nearby the device. The maximum authorised ambient temperature / ... °C at the electronic housing is dependent from the process temperature ... °C/. (Please notice diagram at page VF6-EID-04) Maximum surface temperature T The maximum surface temperature T means the hottest point at the equipment. Pressure, vacuum Design of the devices is suitable for indicated pressures in the vessel. These pressures are outside of the range for atomospheric conditions defined in the guidance to the ATEX-Product-Directive. M LLET Füllstandtechnik Typ VF6.A1 B1 ... GmbH 0044 Industriepark RIO 103 D-74706 Osterburken Tel. +49 62 91 64 400 IBExU19ATEX1052 IP66/IP67 W II 1/2D Ex ta/tb IIIC T95°C Da/Db Supply 20...250 V AC/DC S# 1234567890 A.- Nr. 1234567890 03/19 -20°CTa+80°C/(+50°C)+60°C Consumption 3 VA p (Process) -0,95bar...+10,0bar Contact 5 A / 250 V AC~ T 80°C T 80°C T 95°C VF62 Process temperature Ta = -20°C ... +80°C Ambient Ta = temperature -20°C ... (+50°C)+60°C zone 20 zone 21 p (Process) -0,95bar...+10,0bar 004-0301.CDR 02 VF6-EID-02 06/21 © by MOLLET Explosion protection information MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 www.mollet.de M LLET Füllstandtechnik GmbH Vibro level indicator VF6. Order code VF65A1B1 ... Marking: II 1 / 2 D Dust Equipment category appropriation by zones Vibro level indicator for use at the boundary from zone 20 to zone 21. Ambient temperatures Ta The ambient temperature Ta defines the maximum operating temperature of the indicators. Inside the vessel this is process temperature (the air or the bulk goods temperature) nearby the device. The maximum authorised ambient temperature / ... °C at the electronic housing is dependent from the process temperature ... °C/. (Please notice diagram at page VF6-EID-04) Maximum surface temperature T The maximum surface temperature T means the hottest point at the equipment. Pressure, vacuum Design of the devices is suitable for indicated pressures in the vessel. These pressures are outside of the range for atomospheric conditions defined in the guidance to the ATEX-Product-Directive. M LLET Füllstandtechnik Typ VF65A1 B1 ... GmbH 0044 Industriepark RIO 103 D-74706 Osterburken Tel. +49 62 91 64 400 IBExU19ATEX1052 IP66/IP67 W II 1/2D Ex ta/tb IIIC T95°C Da/Db Supply 20...250 V AC/DC S# 1234567890 A.- Nr. 1234567890 03/19 -20°CTa+70°C/(+55°C)+60°C Consumption 3 VA p (Process) -0,95bar...+10,0bar Contact 5 A / 250 V AC~ T 95°C VF65 T 70°C Process temperature Ta = -20°C ... +70°C Ambient Ta = temperature -20°C ... (+55°C)+60°C zone 20 zone 21 p (Process) -0,95bar...+10,0bar 004-0302.CDR Inside high process temperature, outside ambient temperature Order code VF62A1B1...E1... and VF63A1B1...E1... Marking: II 1 / 2 D Dust Maximum surface temperature T Probe and vibration rod produce no increase of temperature, but they are able to take high temperatures from inside of the vessel and forward it. Due to this, the surface temperature has to be determined according to the process temperature (temperature of bulk solids or ambient) inside of the vessel. The maximum authorised ambient temperature / ... °C at the electronic housing is dependent from the process temperature ... °C/. (Please notice diagram at page VF6-EID-04) T 95°C VF63...E1 T 150°C T 150°C T 150°C T 150°C T 95°C VF62...E1 Process temperature Ambient Ta = Ta = temperature -20°C ... +150°C -20°C ... (+50°C)+60°C zone 20 zone 21 M LLET Füllstandtechnik Typ VF6.A1 B1 ... E1 ... GmbH 0044 Industriepark RIO 103 D-74706 Osterburken Tel. +49 62 91 64 400 IBExU19ATEX1052 IP66/IP67 W II 1/2D Ex ta/tb IIIC T95°C Da/Db Supply 20...250 V AC/DC S# 1234567890 A.- Nr. 1234567890 03/19 -20°CTa+150°C/(+50°C)+60°C Consumption 3 VA p (Process) -0,95bar...+10,0bar Contact 5 A / 250 V AC~ 004-0303.CDR MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 www.mollet.de Explosion protection information 06/21 © by MOLLET VF6-EID-03 03 GmbH M LLET Füllstandtechnik Separate electronic housing Order code VF62A22B3... and VF63A22B3... Marking: II 1 / 3 D Vibro level indicator VF6. Dust Equipment category appropriation by zones Vibro level indicator for use at the boundary from zone 20 to zone 22. Ambient temperatures Ta The ambient temperature Ta defines the maximum operating temperature of the indicators. Inside the vessel this is process temperature (the air or the bulk goods temperature) nearby the device. Maximum surface temperature T The maximum surface temperature T means the hottest point at the equipment. Pressure, vacuum Design of the devices is suitable for indicated pressures in the vessel. These pressures are outside of the range for atomospheric conditions defined in the guidance to the ATEX-Product-Directive. T 80°C VF62A22 or VF63A22 T8905°C T 985°C Ambient temperature Ambient temperature Process temperature Ta = -20°C ... +80°C Ta = -20°C ... +60°C zone 20 zone 22 GmbH 0044 M LLET Füllstandtechnik Industriepark RIO 103 D-74706 Osterburken Tel. +49 62 91 64 400 IBExU19ATEX1052 IP65 Typ VF6. A22 B3 ... W II 1/3D Ex ta/tc IIIC T95°C Da/Dc Supply 20...250 V AC/DC S# 1234567890 A.- Nr. 1234567890 03/19 -20°CTa+80/+60°C p (Process) -0,95bar...+10,0bar Consumption 3 VA Contact 5 A / 250 V AC~ p (Process) -0,95bar...+10,0bar 004-0304.CDR Ambient temperature / ... °C VF65 VF62 VF63 VF62...E1 VF63...E1 Maximum ambient temperatures The maximum authorised ambient temperature / ... °C at the electronic housing is dependent from the process temperature ... °C/. (please notice diagram) 70 60 50 40 30 50 60 70 80 90 100 110 120 130 140 150 Process temperature ... °C/ Example Ta - marking maximum authorised process temperature maximum authorised ambient temperature at the electronic housing / -20 °C Ta +150 °C (+50 °C) +60 °C Due to high process temperature reduced maximum authorised ambient temperature at the electronic housing maximum authorised process temperature / -20 °C Ta +80 °C +60 °C maximum authorised ambient temperature at the electronic housing 04 VF6-EID-04 06/21 © by MOLLET Explosion protection information MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 www.mollet.de M LLET Füllstandtechnik GmbH Vibro level indicator VF6. Special conditions and instructions for safe application 1. The installation, maintenance, initial operation, removal and repair have to be controlled resp. checked by an "authorized person" for explosion protection. 2. For the electrical connection you have to take notice of the local and statutory requirements and/or the VDE 0100. 3. Take notice of the specifications on the data plate. 4. A fuse (with max. 4A) has to be connected in series to the voltage supply. 5. Protect the signal contact from voltage peaks when inductive loads are connected. 6. As soon as the device will be brought into the explosion hazardous area it has to be mounted immediately at the intended place and a cable has to be brought into the cable gland. 7. Please check if the cable gland have loosened during mounting process or transport. When it is loosened, it has to be fixed again with a torque of 3.75 Nm. 8. To secure the type of protection, the screw nut of the cable gland has to be fixed at the installation with a minimum torque of 2.7 Nm. ATTENTION! If it will be fastened too strong, the IP-protection can be affected. 9. The device has to be grounded and the ground connection of the device has to be installed in such a way that mechanical damage will be excluded. 10. The device may put into operation with built-in cap-sealing and when it is closed, only. 11. Remove the dust from the housing before you open it and make sure that no dust turbulences exist. 12. Switch off the power supply, before opening the device. (touchdangerous voltage) 13. Please check position and intactness of all gaskets before you close the device. 14. Tightening torque of distance nut M6x40: 3 ... 4 Nm and of the lid screw M6x16: 3 Nm. 15. The maximum authorised temperatures for process (bulk solids) and ambience have to be observed. 16. Take notice of the requirements of DIN EN 60079-14, DIN EN 60079-17 and DIN EN 1127-1, especially regarding the dust deposits and temperatures and follow the pertinent rules and regulations._ _ MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 www.mollet.de Explosion protection information 06/21 © by MOLLET VF6-EID-05 05 M LLET Füllstandtechnik GmbH Vibro level indicator VF6. 06 VF6-EID-06 06/21 © by MOLLET Explosion protection information MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 www.mollet.de