User Guide for ring models including: ring, Motion Detector, 2nd Generation, Z-Wave
Manufacturer Manual
Ring Alarm Motion Detector (2nd gen) Z-Wave Technical Manual – Ring Help
File Info : application/pdf, 11 Pages, 115.88KB
DocumentDocumentMotion Detector 2nd Generation Z-WaveTM Technical Manual 1 Ring Motion Detector Introduction Ring Alarm Motion Detector is a wireless sensor for the Ring Alarm system which provides users the ability to know when there is movement of a person or similar object within an area. After installing the sensor and setting up the sensor in the Ring app, monitor and receive notifications motion is detected. The Ring Alarm Base Station is required to enable Motion Detector features and functions within the Ring app. Notes: 1. This product can be operated in any Z-WaveTM network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. 2. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. 2 Installation & Set Up Ring Alarm Motion Detector Basic Setup & Installation In-app Setup 1. Ensure your Ring Alarm system is disarmed. 2. In the Ring app, tap Set Up a Device and find the Motion Detector in the Security Devices menu. 3. Follow the in-app instructions to complete setup. a. Pull the battery tab (or reinsert the batteries) to trigger setup mode. b. Tap the button on the front to retry setup mode. Installation 1. Choose a location for installing your Motion Detector. a. For best coverage, install the Motion Detector at a height of between 7-8 feet b. It is recommended to install the Motion Detector on a wall or in a corner looking out onto an area to monitor. c. Ensure no large objects block the field of view (FOV) of the Motion Detector. 2. Ensure the surface where you plan to install your Motion Detector is clean and free from dust or dirt. 3. Using the provided double-sided tape, peel the backing and attach the Motion Detector to the mounting location. Note Leave ~ ½ in. of space free on the top side to ensure you can slide open the case when it's time to change the batteries. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. This is a SmartStart enabled product which can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. This product can also be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. Z-Wave Instructions Z-Wave Device Type: Notification Sensor Role Type: Listening Sleeping Slave GENERIC_TYPE_SENSOR_NOTIFICATION (0x07) SPECIFIC_TYPE_NOTIFICATION_SENSOR (0x01) 3 4 Ring Alarm Motion Detector Inclusion Adding Ring Alarm Motion Detector to a Z-Wave Network Ring Alarm Motion Detector can be added via SmartStart or Classic inclusion mode. Note When prompted for the QR Code or PIN, you may find them on the device, on the box, or on a card inside the box. Keep the device nearby. You'll be prompted to pull the battery tab to power on the device and enter setup mode. SmartStart Inclusion Steps: 1. Initiate the add flow for Security Devices in the Ring mobile application Follow the guided add flow instructions provided in the Ring mobile application. 2. When prompted by the mobile application, scan the QR code found on the package of the Motion Detector. The QR code can also be found on the device itself. 3. Pull the pull-tab or insert batteries, and the device will go into SmartStart inclusion mode. While in this mode, Motion Detector can be added to a Z-Wave controller that supports SmartStart. When in SmartStart inclusion mode, SmartStart can be restarted by tapping the button on the front of the device. Classic Inclusion Steps: Classic Inclusion should be used if the controller does not support SmartStart. 1. Initiate add flow for Security Devices in the Ring mobile application Follow the guided add flow instructions provided in the Ring mobile application. 2. Select add manually and enter the 5-digit DSK PIN found on the package of the Ring Alarm Motion Detector or the 5-digit DSK PIN found under the QR code on the device. 3. After powering on the device, press and hold the button on the front of the device for ~3 seconds. Release the button and the device will enter Classic inclusion mode which implements both classic inclusion with a Node Information Frame, and Network Wide Inclusion. During Classic Inclusion mode, the green LED will blink three times followed by a brief pause, repeatedly. When Classic inclusion times-out, the device will blink alternating red and green a few times. LED Behabior for Inclusion SmartStart Started Blink Pattern Green LED three times, repeated after a brief pause Classic Inclusion Started Green LED three times, repeated after a brief pause Classic Inclusion Timed-Out Alternate red and green a few times Inclusion Successful (Authenticated S2) Green LED on solid Inclusion Not Successful (Self-Destruct) Red LED on solid 5 Ring Alarm Motion Detector Exclusion Removing Ring Alarm Motion Detector from a Z-Wave Network Exclusion Instructions: 1. Initiate remove "Ring Alarm Motion Detector" flow in the Ring Alarm mobile application Select the settings icon from device details page and choose "Remove Device" to remove the device. This will place the controller into Remove or "Z-Wave Exclusion" mode. 2. Locate the pinhole reset button on the back of the device in the battery compartment. 3. With the controller in Remove (Z-Wave Exclusion) mode, use a paper clip or similar object and tap the pinhole button. The device's red LED turns on solid to indicate the device was removed from the network. Ring Alarm Motion Detector Factory Reset Factory Default Instructions 1. To restore Ring Alarm Motion Detector to factory default settings, locate the pinhole reset button on the device. This is found inside the battery compartment on the back of the device after removing the back bracket. 2. Using a paperclip or similar object, insert it into the pinhole, press and hold the button down for 10 seconds. 3. The device will rapidly blink green continuously for 10 seconds. After about 10 seconds, when the green blinking stops, release the button. The red LED will turn on solid to indicate the device was removed from the network. Note Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. Wake-Up Notification Not applicable. Ring Alarm Motion Detector is a Frequently Listening Receiver Slave (FLiRS) device and does not support Wake Up Command Class. 6 Z-Wave Command Classes Command Class Association Association Group Information Device Reset Locally Firmware Update Meta Data Indicator Manufacturer Specific Multi-Channel Association Powerlevel Security 2 Supervision Transport Service Version Z-Wave PlusTM Info Notification Wake Up Configuration Battery Version Required Security Class 2 Highest granted 3 Highest granted 1 Highest granted 5 Highest granted 3 Highest granted 2 Highest granted 3 Highest granted 1 Highest granted 1 none 1 none 2 none 3 Highest granted 2 none 8 Highest granted 2 Highest granted 4 Highest granted 2 Highest granted Association Command Class Group Identifier 1 (Lifeline) Max Nodes 0x05 Description 1. Notification Report a. See notification CC section for notifications that are sent 2. Battery Report 3. Device Reset Locally Notification 7 Configuration Command Class The sensor has the following supported configuration parameters. Parameter Number 1 2 3 4 5 Description Number of Bytes Heartbeats: This parameter is the number minutes between heartbeats. Heart- 1 beats are automatic battery reports on a timer after the last event. Number of application level retries attempted for messages either not ACKed or messages encapsulated 1 via supervision get that did not receive a report. Application Level Retry Base Wait Time Period: The number base seconds used in the calculation for 1 sleeping between retry messages. This parameter allows a user, via software, to configure the various LED indications on the device. 0 == Don't show green 1 == Show green after Supervision 1 Report Intrusion (Fault) 2 == Show green after Supervision Report both Intrusion and Intrusion clear The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get 2 encapsulated command from the sensor before attempting a retry. Default 70 (0x46) 1 (0x01) 5 (0x05) 1 (0x01) 1500 (0x5DC) 6 Occupancy Clear Delay (seconds) 2 0x00 7 Intrusion Clear Delay (seconds) 1 0x05 8 Standard Clear Delay (seconds) 1 0x0A 9 Motion Detection Mode 1 0x03 10 Any motion Threshold 1 0x80 11 Lighting Enabled 1 0x00 12 Lighting Delay 1 0x02 Min Max 1 (0x01) 70 (0x46) 0 (0x00) 5 (0x05) 1 (0x01) 60 (0x3C) 0 (0x00) 2 (0x01) 500 (0x1F4) 5000 (0x1388) 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xFF 0x04 0xFF 0x01 0x3C Format 0x01 Unsigned 0x01 Unsigned 0x01 Unsigned enum 0x01 Unsigned 0x01 Unsigned 0x01 Unsigned 0x01 Unsigned 0x01 Unsigned 0x01 Unsigned 0x01 Unsigned 0x01 Unsigned 8 Notification Command Class, V8 Sensor Condition Command Class and Value Association Group Motion Detected Motion Cleared Sensor Case Removed Sensor Case Fastened Comm Test Button Pressed Watchdog Notification Software Fault (Ring) Software Fault (SDK) Pin Reset (soft reset) Software Reset (Not triggered by failure) Power On Brownout Dropped Frame Co-Processor Watchdog Failed to retrieve FW version of Co-Processor Notification Report Type: Home Security 0x07 State: Intrusion 0x08 Notification Report Type: Home Security 0x07 State: Previous Events Cleared 0x00 Event parameter: 0x08 Notification Report Type: Home Security 0x07 State: Tampering Product Covering Removed 0x03 Notification Report Type: Home Security 0x07 State: Previous Events Cleared 0x00 Event Parameter: 0x03 Notification Report Type: System 0x09 Event: Heartbeat 0x05 Notification Report Type: System 0x09 State Value: 0x04 System Software Failure State Parameter Value = 0x55 Notification Report Type: System 0x09 State Value: 0x04 System Software Failure State Parameter Value = 0xAA (Ring Value for Soft Fault) Notification Report Type: System 0x09 State Value: 0x04 System Software Failure State Parameter Value = 0xA9 (SDK Value for Soft Fault) Notification Report Type: System 0x09 State Value: 0x04 System Software Failure State Parameter Value = 0xAB Notification Report Type: System 0x09 State Value: 0x04 System Software Failure State Parameter Value = 0xAC Notification Report Type: 0x08 Power Management Event Parameter: 0x01 Power has been applied Notification Report Type: 0x08 Power Management Event: 0x05 Voltage Drop/Drift Notification Report Type: 0x08 Power Management Event Parameter: 0x01 Power has been applied Notification Report Type: System 0x09 State Value: 0x04 System Software Failure State Parameter Value = 0xAE Notification Report Type: System 0x09 State Value: 0x04 System Software Failure State Parameter Value = 0xAF 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 1 (Lifeline) 9 Supplier's Declaration of Conformity Compliance Information Statement Unique Identifier: Ring Contact Sensor Responsible Party and Party issuing Supplier's Declaration of Conformity Ring LLC dba Ring 1523 26th Street Santa Monica, CA 90404 U.S.A. www.ring.com / Legal@ring.com FCC Compliance Statement (for products subject to Part 15) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Innovation, Science and Economic Development Canada (ISED) Compliance This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Conformité Innovation Sciences et Développement Économique Canada (ISDE) L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: 1. L'appareil ne doit pas produire de brouillage. 10 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. CAN ICES-3 (B)/NMB-3(B) In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 cm is maintained from the general population. Conformément aux exigences d'Industrie Canada en matière d'exposition humaine aux champs de radiofréquences, l'élément rayonnant doit être installé de telle sorte qu'une distance minimale de 20 cm soit maintenue par rapport à la population générale. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. AVERTISSEMENT : Tout changement ou modification à cet appareil qui n'a pas fait l'objet d'une autorisation expresse par la partie responsable de sa conformité pourrait annuler le droit pour l'utilisateur d'opérer l'équipement. CAUTION: To reduce the risk of electrical shock, DO NOT open the unit. There are no user serviceable parts inside the unit. Refer to customer support for any repairs. ATTENTION : Pour réduire le risque d'électrocution, NE PAS ouvrir l'appareil. Aucune pièce interne n'est réparable par l'utilisateur. Veuillez vous référer au service à la clientèle pour toute réparation. CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of the used batteries according to the manufacturer's instructions. ATTENTION : Danger d'explosion si la pile n'est pas remplacée correctement. Remplacez la pile uniquement par une pile identique ou par une pile du même type que celle recommandée par le fabricant. Suivez les instructions du fabricant pour jeter les piles usées. To review your warranty coverage, please visit www.ring.com/warranty. © 2020 Ring LLC or its affiliates. Ring, Always Home, and all related logos are trademarks of Ring LLC or its affiliates. 11Adobe PDF Library 15.0 Adobe InDesign 15.0 (Macintosh)