Televes Rack PDU with Schuko Outlets
Models: Ref. 533001 (USDL8), Ref. 533007 (USDL410)
Introduction
These power distribution units provide power supply to rack-mounted equipment. They feature an aluminum enclosure that provides excellent thermal conductivity.
Main Features
- Ref. 533001 for 19" Rack: Features an On-Off switch to control the PDU power supply.
- Ref. 533007 for 10" Rack: Equipped with a green LED that indicates the PDU is supplied with power.
- Includes 4 screws and 4 cage nuts for installation.
Technical Specifications
Feature | Technical Specifications | 533001 (USDL8) | 533007 (USDL410) |
---|---|---|---|
Sockets | Quantity / Type | 8 | 4 |
Chassis | Material | Aluminum | Aluminum |
Power cord | Connector | Schuko (DIN49440) | Schuko (DIN49441) |
Color | Cable / Cord | 3 x 1.5mm² x 2m | 3 x 1.5mm² x 2m |
Occupation in rack | Color | Black (RAL 9005) | Black (RAL 9005) |
On-Off switch | Type | Double pole switch | - |
Voltage | Voltage | 100~240V / 50-60Hz | 100~240V / 50-60Hz |
Maximum current | Maximum current | 16 A | 16 A |
Maximum power | Maximum power | 3840 W | 3840 W |
Protection index | IP | IP20 | IP20 |
Weight | Weight | 543.5 ± 5% g | 254.5 ± 5% g |
Dimensions | Dimensions (mm) | 482 x 45 x 45 | 254.5 x 45 x 45 |
Important Safety Instructions
Safe Installation
- Read these instructions before handling or connecting the equipment. Keep these instructions. Heed all warnings. Follow all instructions.
- Clean only with dry cloth.
- Do not use this apparatus near water. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as glasses, shall be placed on the apparatus.
- Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. Please allow air circulation around the equipment.
- Do not place the equipment in a highly humid environment.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not place naked flames, such as lighted candles on or near the product.
- Do not place the equipment in a place where it can suffer vibrations or shocks.
- Only use attachments/accessories specified by the manufacturer.
Safe operation of equipment connected to the mains supply
- Ambient temperature should not be higher than 45°C.
- Power requirements for this product are: 100-240V~50/60Hz.
- It is strongly recommended not to connect the equipment to the mains supply until all connections have been done.
- The socket outlet shall be installed near the equipment and shall be easily accessible.
- To disconnect the equipment from the mains supply pull the plug never the cable.
- Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
- Unplug this apparatus during lightning storms or when unused for long periods of time.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Warning
Reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
Simbology
Caution, risk of electrical shock. [!]
The equipment meets the safety requirements specified for Class II equipment. [II]
CE The equipment meets the CE marking requirements. [CE]
The equipment is designed for indoor use. [indoor-icon]
Declaration of Conformity
Televés S.A.U. Rúa B. de Conxo, 17 - 15706 Santiago de Compostela, A Coruña, Spain. www.televes.com
For more information, visit: https://doc.televes.com
Related Documents
![]() |
Televes 533007: 1RU 10" Rack Power Distribution Unit with 4 Schuko Outlets Product sheet for the Televes 533007, a 1RU 10-inch rack-mountable power distribution unit (PDU) featuring 4 Schuko-type 16A outlets, a 2m power cord, and a green LED indicator switch. Includes detailed physical and technical specifications. |
![]() |
Televes 1U 8-Outlet Schuko Power Strip for 19" Racks A 1U high power strip from Televes with 8 Schuko-type, 16A outlets, designed for 19" rack installations. Features an illuminated power switch with a protective cover, high strength aluminum construction, and easy installation. |
![]() |
Televes 524701 Multimedia Outlet: TV, FM, and Data Detailed specifications and features of the Televes 524701 multimedia outlet, a series outlet with three outputs for TV (IEC male), FM (IEC female), and DATA (F connector), compatible with DOCSIS 3.1. Includes technical data, packaging information, and unique characteristics. |
![]() |
Televes 524201 TV+FM+SAT Series Outlet: 11 dB DC Pass Detailed information on the Televes 524201, a series outlet for TV, FM, and SAT with 11 dB DC pass. Features include Zamak construction for high shielding, screwless connection, and compatibility with coaxial cables. |
![]() |
Televes 524801 FM-TV-DATA Pass-Through Multimedia Outlet Detailed specifications and features of the Televes 524801, a 3-connector pass-through multimedia outlet for FM, TV, and DATA. Includes technical data, packaging information, and key features for installation. |
![]() |
Televes 5229 FM/TV-SAT Terminal Outlet: Features and Specifications Detailed information on the Televes 5229 terminal outlet, featuring two CEI connectors for FM/TV terrestrial and TV satellite, with screwless fixing and Class A shielding. Includes technical specifications and product highlights. |
![]() |
Televes 10"-Rack Cabinet 7RU 300x265 mm: Data and Coaxial Distribution Detailed specifications and features of the Televes 10"-Rack Cabinet 7RU 300x265 mm, a robust steel cabinet designed for data, fiber, and coaxial cable distribution with 24-connection panels. |
![]() |
Televes TV/SAT Terminal Outlet, 0dB - Product Sheet Product sheet for the Televes TV/SAT terminal outlet, 0dB. This outlet is designed for receiving terrestrial and satellite signals and features a single connector. It includes technical specifications, physical data, and key features like improved shielding and DC pass-through for satellite input. |