Product Information
Manufacturer: Zhejiang Micade Industry and Trade Co., Ltd.
Address: Jinheng 2nd Road, Jinyan Mountain Industrial Zone, Wuyi County, Zhejiang, China
After-sales Email: support@hychika.com
British Representative: CET Product Service Ltd.
European Representative: EUREP GmbH.
Certifications: CE, RoHS, IPX4
Website: www.hychika.com
Tech-data
Parameter | Specification |
---|---|
Model | MWD192-1000W-12L |
Voltage | 220V-240V |
Frequency | 50/60Hz |
Power | 1000W |
Max Capacity | 12L |
Vacuum degree | ≥17Kpa |
Airflow | 1.6m³/min |
1. Product Characteristics
- Vacuum cleaner for wet and dry use.
- Features jacks on the base for easy accessory storage.
- Includes a blowing function to satisfy different requirements.
2. Structure and Parts Name
The vacuum cleaner consists of the following parts:
- 1. Waterproof switch
- 2. Handle
- 3. Top cover
- 4. Barrel cap
- 5. Plastic clip
- 6. Plastic barrel
- 7. Bases with wheels
- 8. Suction mouth
- 9. Plastic hose
- 10. Plastic tubes
- 11. Wet&Dry floor brush
- 12. 2 in 1 crevice nozzle
- 13. Sponge filter
- 14. HEPA filter
- 15. Paper bag
- 16. Floor nozzle
Diagram Description: An illustration shows the main body of the vacuum cleaner with various attachments, numbered according to the list above.
3. Safety Instruction
General Safety Precautions:
- Check before operation that the local power supply matches the specification on the rating label.
- Do not use the machine in combustible and explosive places, as motor sparks may cause fire.
- Do not block the air inlet to prevent motor damage due to overheating.
- Do not collect combustible and explosive objects such as burning cigarettes or gasoline.
- Do not collect sharp objects.
- Avoid collecting objects that can easily stick to the filter, such as calcareousness powder, gesso, and graphite powder, as they can block ventilation and damage the motor.
- Do not overturn the machine to prevent water from entering the motor and causing damage.
- Warning: If water enters the motor, it can cause damage. Do not use this machine as a pump if the motor overheats.
- Turn off the machine and remove the plug after each use or before repair.
- Keep the machine away from strong sunlight and high temperatures to prevent plastic distortion.
- Do not twist, tread on, or drag the hose if it is damaged.
- Do not immerse the barrel cap in water or wash it with water if water might enter the electrical parts and cause injury. The correct cleaning method is to first dampen a cloth, then dry it, and finally wipe the dirty part gently.
- The power cord must be replaced by a designated repair center or qualified professionals.
Diagram Description: Illustrations show warnings against using the vacuum with flammable liquids like alcohol or gasoline, and against blocking the air inlet or collecting sharp/sticky objects. Another diagram shows a warning about not overturning the machine.
4. Operation Method
(1) Connection
- Insert the hose connector into the air inlet mouth; ensure the connector is tightly fastened.
- To detach the hose connector, press the connector button as shown in the picture and pull the connector out.
Diagram Description: Two images illustrate connecting and disconnecting the hose to the vacuum's air inlet.
(2) Accessories
- Connect the appropriate accessories for wet or dry cleaning as shown in the picture.
Diagram Description: An image shows the vacuum cleaner with various attachments connected, ready for use.
(3) Base Assembly
- Ensure the 4 bases with wheels are securely and correctly assembled to the bottom of the machine for stable movement.
- Fit the screws for each base piece into the holes on the bottom of the plastic tank and press them in.
Diagram Description: Illustrations show the process of attaching the wheeled base components to the vacuum cleaner's main body.
(4) Filter Installation
- For cleaning liquids: Install the sponge filter on the water valve (located below the motor base).
- For cleaning dust: Install the HEPA filter on the water valve (located below the motor base).
- After installing the correct filter, lock the head onto the plastic tank.
Diagram Description: Images illustrate the installation of sponge and HEPA filters onto the motor base assembly, followed by attaching the main body.
(5) Blowing Function
- To use the blower function, insert the hose connector into the blowing mouth as shown in the picture.
Diagram Description: An image shows the vacuum cleaner set up for blowing, with the hose connected to a different port.
(6) Operation
- Insert the plug into the power socket.
- Press the switch; the machine will start working.
- Adjust the airflow by sliding the block up and down. The switch has 'I' for ON and '0' for OFF.
Diagram Description: Two images illustrate the power switch ('I' for ON, '0' for OFF) and an airflow adjustment slider.
5. Protective Device (Safety Valve)
Special Instructions:
- When the barrel is full of water, the safety device activates, and suction power will cease. The motor may produce noise indicating high speed. In this situation, disconnect power, empty the water, reassemble, and restart the machine.
- If the machine is overturned, the safety device will activate. Disconnect power, return the machine to an upright position, and then restart.
- If the device is working and the machine is used, the motor may be damaged or burn. Stop use and empty the water immediately.
6. Maintenance
(1) Barrel Cleaning
- After use, or when the barrel is full of dust causing reduced suction, disconnect power and clean the barrel.
- Unfasten the locking knobs and lift the top cover.
- Remove the filters and clean the dirt from the barrel.
- Reinstall the filters and place the top cover back on.
(2) Filter Cleaning
- Filters should be washed with clean, warm water when dirty. A mild detergent or scour can be used if necessary.
- Remove the filters.
- Wash the filters.
- Dry the filters completely.
- Install the filters correctly.
Diagram Description: Illustrations show the process of cleaning the barrel and washing/drying filters (Sponge Filter, HEPA Filter, Cloth Filter), indicating water temperature up to 40°C and a 24-hour drying period.
Declaration of Conformity
This declaration is issued under the sole responsibility of the manufacturer.
Product: Wet&Dry Vacuum
Mode/Type: MWD192-1000W-12L
The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:
- 2006/42/EC (The Machinery Directive)
- 2014/30/EU (The Electromagnetic Compatibility Directive)
- 2011/65/EU (The Restriction of Hazardous Substances Directive)
Conformity is shown by compliance with the applicable requirements of the following documents:
- EN 55014-1:2017
- EN 55014-2:2015
- EN 61000-3-2:2014
- EN 61000-3-3:2013
- EN 60335-2-2:2010+A11:2012+A1:2013
- EN 60335-1:2012+A11:2014+A13:2017
- EN 62233:2008
Signed for and on behalf of:
Date of issue: 4th June 2021
Name: Spencer Tang
Position: QA Director
The technical documentation for the machinery is available from the addresses listed above.