User Guide for Honeywell models including: AQ3CO SENSOR, Carbon Monoxide CO Gas Sensor
Sensor Part Number (without board): ABQ045-H00 Module Part Number (with board): QAB045-H00 PCBA Part Number: AQ3-BP01 FEATURES AND BENEFITS High resolution Low detection limit Custom-built low noise
The data provided in this document is based on the assumption that the sensor is used at 20°C, 50% rH, and 1013 mBar for three months from the date of ...
File Info : application/pdf, 4 Pages, 738.21KB
DocumentDocumentAQ3CO SENSOR Carbon Monoxide (CO) Gas Sensor The purpose of this document is to present the performance specification of the AQ3 Series AQ3CO Carbon Monoxide Gas Sensor. DOCUMENT PURPOSE This document should be used in conjunction with the AQ3CO Characterization Note and the Product Safety Datasheet (PSDS 15). The data provided in this document is based on the assumption that the sensor is used at 20°C, 50% rH, and 1013 mBar for three months from the date of sensor manufacture. For guidance on sensor performance outside of these limits, please refer to the AQ3CO Characterization Note. Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Characterization Note. Sensor Part Number (without board): ABQ045-H00 Module Part Number (with board): QAB045-H00 PCBA Part Number: AQ3-BP01 FEATURES AND BENEFITS High resolution Low detection limit Custom-built low noise board achieves high accuracy under ppb level Individual compensation for temperature and cross sensitivity High correlation with control station AQ3CO Carbon Monoxide Gas Sensor Technical Specifications TECHNICAL SPECIFICATIONS MEASUREMENT Technology 4-electrode electrochemical Measurement Range 0 ppm CO to 10 ppm CO Maximum Overload without board: 50 ppm CO with board: 30 ppm CO Onboard Filter Sensitivity* to remove SOx/NOx and H2S without board: 240 nA/ppm ±80 nA/ppm with board: 90 mV/ppm ±35 mV/ppm Response Time (T90) Resolution* < 70 seconds 20 ppb when used with recommended circuitry Baseline Offset* without board: -200 nA ~ 360 nA with board: -80 mV ~ 140 mV Repeatability* < ±3% of signal Linearity** linear Low Detection Limit* 40 ppb ELECTRICAL Recommended Load Resistor 68 Sensor Bias Voltage no bias (without board) Power Supply Required 5 Vdc (with board) Power Consumption 370 mA @ 5 Vdc (with board) MECHANICAL Weight without board: < 22 g with board: < 30 g Outer Plastic Body Material polycarbonate Sealing Gasket Material TPU Contact Material mild steel with gold flash-over nickel plate Orientation Sensitivity none ENVIRONMENTAL Operating Temperature Range -30°C to 50°C Recommended Storage Temperature 0°C to 20°C in original sealed container Operating Humidity Range 15% rH to 90% rH non-condensing Operating Pressure Range atmospheric ±10% Typical Applications ambient environmental monitoring LIFETIME Product Dimensions Dimensions mm. All tolerances ±0,15 mm unless otherwise stated Sensor without board Ø 41,2 mm 17,8 mm Counter Ø 3,0 mm Ø 1 mm on 34.2 PCD 3,0 mm pin projection Sensing Reference Ø 42,5 mm 3 mounting holes equi-spaced on 34.4 PCD Auxiliary Sensor with board Ø 41,2 mm Non-connected pin A SEE DETAIL Ø 41 mm Ø 42,5 mm 0,6 mm 17,8 mm 25,3 mm 5,72 mm 13,8 mm 1,27 mm 60° 1 2 3 4 5 DETAIL A 1,27 mm Storage Life 6 months in original sealed container Long-Term Sensitivity Drift* < 10% signal loss per annum Expected Oper. Life two years in air Warranty one year *Specifications are valid at 20°C, 50% RH, and 1013 mbar using AQ3 low noise board. Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time. Please be aware that sensors' performance also reflected by circuit board design. ** Linear through the concentration range across the whole operational environment range. 15,4 mm 17,2 mm B SEE DETAIL 4,8 mm SAME PINS WITH DETAIL B 1,91 mm 3 Ø 3 mm DETAIL B: 2 COUPLE OF LOCATION PINS Pin Definition 15,4 mm 1 Vin (4.8 V ~ 5.5 V) 2 GND 3 Aux 4 GND 5 Sensing AQ3CO Carbon Monoxide Gas Sensor Datasheet | sps.honeywell.com/ast | 2 AQ3CO Carbon Monoxide Gas Sensor Technical Specifications Filter Information Removes acid gases such as SOx/NOx and H2S Poisoning Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided, during storage, fitting into instruments, and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the sensor as the solvent may cause crazing of the plastic. Cross Sensitivity Table Whilst AQ3 Series gas sensors are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various other gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react. IMPORTANT NOTE: The cross sensitivity data shown below does not form part of the product specification and is supplied for guidance only. Values quoted are based on tests conducted on a small number of sensors and any batch may show significant variation. For the most accurate measurements, an instrument should be calibrated using the gas under investigation. Gas Sulfur Dioxide (SO2) Nitrogen Dioxide (NO2) Ozone (O3) Isobutylene (C4H8) Gas Concentration 5 ppm 5 ppm 1 ppm 1 ppm Cross Interference 0%<x%<7% -3%<x%<5% -7%<x%<4% ~None AQ3CO Carbon Monoxide Gas Sensor Datasheet | sps.honeywell.com/ast | 3 WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer's sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. m WARNING MISUSE OF DOCUMENTATION · The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. · Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. , SAFETY NOTE This sensor is designed to be used in environmental applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the sensor and/or instrument. Failure to carry out such tests may jeopardize the safety of people and property. FOR MORE INFORMATION Honeywell Advanced Sensing Technologies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit our website or call: USA/Canada Latin America Europe Japan Singapore Greater China +1 302 613 4491 +1 305 805 8188 +44 1344 238258 +81 (0) 3-6730-7152 +65 6355 2828 +86 4006396841 Honeywell Advanced Sensing Technologies 830 East Arapaho Road Richardson, TX 75081 sps.honeywell.com/ast AQ3CO Datasheet ECN 5062 | 002722-1-EN | 1 | 05/21 © 2021 Honeywell International Inc.