SEL-FLT and SEL-FLR
Improve distribution reliability with the SEL-FLT and SEL-FLR system, which enables faster fault locating, reduces outage durations, and improves the average restoration time.
Improve distribution reliability with the SEL-FLT and SEL-FLR system, which enables faster fault locating, reduces outage durations, and improves the average restoration time.
Locate momentary and permanent faults in overhead applications. The SEL-AR360 and SEL-AR automatically adjust their trip thresholds to coordinate with the load current in distribution systems up to 69 kV.
Provide maintenance-free fault indication with a battery-free design and automatic voltage reset.
Locate momentary and permanent faults in overhead applications. The SEL-BTRIP provides four field-selectable trip thresholds so you can stock one fault indicator for multiple applications.
Reduce the need to access vaults or open pad-mounted enclosures to retrieve the fault indicator status, decreasing fault-locating time and improving safety.
Optimize outage management and improve underground system reliability.
Use the Dynamic Delayed Trip feature to improve coordination with upstream protection, maximizing reliable performance.
Easily install the SEL-TPR on most brands of 200 A or 600 A elbows with capacitive test points. It is ideal for pad-mounted transformer and switchgear applications.
Monitor underground systems with the SEL-CR, which is powered by the load current present on an energized line.
Apply the SEL-SR to pad-mounted transformers when there is insufficient primary current to power and reset current-powered fault indicators.
Indicate both momentary and permanent faults in underground distribution systems with low load and low voltage.
Use the SEL-MW in place of PTs to detect system voltage loss where exact system voltage measurement reporting is not required. The SEL-MW indicates voltage loss via a contact output.
Apply the SEL-PILC on paper-insulated lead-covered cables. It features a rugged design and can be submerged in up to 15 feet of water.
Apply the SEL-GFD over a three-phase cable bundle at ground potential in switch-gear to identify faults on circuits feeding medical facilities, mining equipment, and other industrial equipment.
Troubleshoot overhead and underground applications up to 38 kV with this portable, fault-powered manual reset fault indicator.
Easily install SEL-VINs on the test point of a 200 A elbow, 600 A T-body, or 600 A basic insulating plug. The line-powered SEL-VIN indicates the presence of voltage at or above 2 kV (phase to ground) by flashing a neon lamp.
Economically add SEL CTs to existing wiring and electrical equipment without interrupting service.
Easily add the SEL-SCT in subsurface vaults where flooding can occur. The separable-core design allows the SEL-SCT to be opened and installed without interrupting the connection.
Easy-to-see displays on SEL fault indicators lead the line crew to the faulted section of the overhead line or underground cable, allowing personnel to visually identify the faulted line section without going through a time-consuming re-fuse and sectionalize process. Applying fault indicators in areas affected by permanent and momentary outages helps resolve disruptions quickly.
Wireless technology further speeds up fault-finding times by reducing the need for patrolling the line to locate the fault. Use SEL fault indicators with distribution protection and automation equipment to improve system reliability indices and reduce operational and maintenance costs.
Improve system planning and operational decision-making by using accurate load data from the SEL-FLT and SEL-FLR Fault and Load Transmitter and Receiver System. These solutions provide underground or overhead load monitoring capability in addition to fault indication.
Diagram description: A power line with a fault indicator showing a fault. Text indicates: 'Reduce fault-locating time by 50 percent or more.'
Improve speed, selectivity, and safety in distribution protection by using the SEL-FT50 and SEL-FR12 Fault Transmitter and Receiver System. Using low-latency communications, the system is fast enough to adapt protection schemes to speed up tripping, block reclosing for underground faults, and improve coordination.
To learn more about the SEL-FT50 and SEL-FR12 system, visit selinc.com/products/FT50.
Diagram description: A system diagram showing a substation with a relay and a fault transmitter connected to an overhead conductor and underground cable. Text indicates: 'Fast communications: <6 ms from the time of fault detection to relay input for enhanced protection and coordination.'
The SEL-FLT and SEL-FLR Fault and Load Transmitter and Receiver System interconnects with existing SCADA, outage management, and distribution management systems to improve situational awareness.
Place SEL-FLT transmitters next to manual- or remote-operated switches to quickly communicate fault and load status to a single SEL-FLR connected to a distribution management system through an IP backhaul. This provides operations personnel with the status confirmation needed to reconfigure the circuit and restore power to as many customers as possible.
Diagram description: A system diagram showing a substation, fault transmitters, and a fault receiver connected to a SCADA system via Ethernet. Text indicates: 'Communicate the fault location to a SCADA system for quick power restoration.'
Starting prices:
The SEL-FLT and SEL-FLR system improves the overall reliability of your distribution system through accurate fault indication and load monitoring. The SEL-FLT Fault and Load Transmitter and the SEL-FLR Fault and Load Receiver work together over unlicensed 900 MHz wireless communications to locate faults faster and make informed switching decisions. Restoring power quickly is essential to ensuring satisfied customers and better Customer Average Interruption Duration Index (CAIDI) reliability metrics.
Locating momentary faults also allows you to address system issues and improve Momentary Average Interruption Frequency Index (MAIFI) metrics. Highly accurate (1% typical) load data enable phase balancing and system planning. Line powering, with as little as 3.5 A of continuous current, reduces ongoing maintenance and allows you to use the SEL-FLT throughout your distribution system. SEL-FLR receivers are easy to integrate in existing systems with DNP3/IP output and comprehensive security.
Diagram description: A system diagram showing a transformer connected to multiple fault transmitters via a distribution line, with a fault receiver communicating wirelessly to a SCADA/Operations system. The diagram indicates support for 'Up to 168 Devices' and communication 'Up to 10 Miles'.
The SEL-FLR integrates easily into existing networks and centralized SCADA systems with standard Ethernet ports and DNP3/IP output. The SEL-FLR can pair with a cellular modem/router or Ethernet radio or can plug directly into a wired Ethernet network. Once connected, data from the SEL-FLT transmitters can flow into a SCADA system, outage management system (OMS), or distribution management system (DMS). You can perform configuration and troubleshooting of the SEL-FLT and SEL-FLR system over the network.
With fault information from the SEL-FLT and SEL-FLR system, utility operations teams can dispatch crews to fault locations faster, speeding up restoration. Flashing LEDs on the SEL-FLT transmitters help line crews confirm the fault location reported through a SCADA system or OMS.
The SEL-FLT and SEL-FLR system can also help locate momentary faults. Addressing the causes of these faults, such as overgrown tree limbs or aging insulators, reduces future faults and momentary interruptions.
Highly accurate and frequent load data from SEL-FLT transmitters on taps and laterals enables better decision-making in emergency switching situations. Load data are also essential for phase balancing, system planning, and identifying power theft.
Diagram description: A diagram illustrating system integration, showing fault transmitters communicating wirelessly to a fault receiver, which connects via Ethernet to a cellular router or a wired network. The network then connects to SCADA, OMS, and DMS systems.
Starting prices:
The SEL-AR360 and SEL-AR are self-adjusting fault indicators for distribution systems. The advanced algorithms in the microprocessor-based technology continually measure the load current and automatically step up or down the trip threshold to coordinate with the load. After an event, the fault indicators analyze system conditions to determine a display notification of either a momentary or permanent fault. They also use inrush restraint technology that activates on the loss of current or voltage to prevent tripping on reclosing attempts.
The SEL-AR360 works on systems up to 34.5 kV and offers 1,800 flashing hours and a 360-degree ultrabright flashing LED display.
The SEL-AR works on systems up to 69 kV and offers 2,500 flashing hours and a forward-facing LED display.
Image description: Image of SEL-AR360 showing 'Momentary fault indication' (yellow/red lights) and 'Permanent fault indication' (red light). Image of SEL-AR showing 'Momentary fault indication' (yellow light) and 'Permanent fault indication' (red light).
Starting Price: $100 USD
The line-powered SEL-ER displays a permanent fault condition by showing a large reflective red target. The red target remains visible until after the line is re-energized. The hermetically sealed UV-stabilized housing and stainless-steel clamp make the SEL-ER tough enough to handle harsh outdoor environments.
Starting Price: $160 USD
Powered by load current, the SEL-CRD reduces fault-finding time on overhead power distribution systems. It indicates a faulted line condition by showing a large red reflective target display. The SEL-CRD automatically resets upon restoration of load current.
Starting Price: $200 USD
The SEL-BTRIP locates momentary or permanent faults in 4,160 V to 69 kV overhead system applications. It is quick and easy to apply using a single hot stick. The field-selectable trip threshold provides control of settings while allowing you to stock only one model. A super-bright flashing LED display provides clear indication of an overcurrent event. The SEL-BTRIP is completely powered by a 3.6 V high-capacity 8.5 Ah lithium battery with a 20-year shelf life.
Starting Price: $130 USD
The battery-powered overhead SEL-BTRI provides automatic reset at the end of a fixed reset period to allow time for crews to locate permanent and momentary faults. It is ideal for locations where false resets from backfeed are a concern, such as applications with single-phase sectionalizing on a three-phase circuit. The loss-of-voltage-activated inrush restraint feature prevents the SEL-BTRI from responding to automatic reclosing events.
Starting price: Interface, Reader, and 3 FCIs: $943 USD
The RadioRANGER system reduces the need to access vaults to retrieve the status of faulted circuit indicators (FCIs), decreasing fault-locating times and improving utility personnel safety. Utility personnel can quickly and safely retrieve the subsurface FCI status at street level through communication between the SEL-8300 RadioRANGER Wireless Interface and the handheld SEL-8310 RadioRANGER Remote Fault Reader. A two-way communications link transmits both faulted (tripped) and normal (reset) status information, preventing any uncertainty in determining if FCIs are plugged into the interface and functioning.
The IP68-rated SEL-8300 and waterproof interconnection system (rated to 4.5 m [15 ft] of submersion in water) ensure environmental integrity for vault applications. Up to 12 SEL FCIs equipped with magnetic RadioRANGER Interface Probes inductively communicate their status to an SEL-8300. The rugged SEL-8310 provides the ID of nearby SEL-8300 Wireless Interfaces as well as the phase and direction of the fault path. To maximize application efficiency, the modular and scalable system works in a variety of vault configurations and offers an estimated 15 years of product life.
The Wireless Interface communicates fault indicator information to the Remote Fault Reader.
The Remote Fault Reader identifies the phase and location of underground faults.
Symbol description: [Radio Ranger Symbol] Look for this symbol to identify RadioRANGER-compatible fault indicators and sensors.
Starting price: Three-Phase System: $2,190 USD
The SEL-8301 optimizes outage management and improves power system reliability. Using a wireless RPMA network, the SEL-8301 sends fault, load current, and water depth information to your control center so you can efficiently dispatch repair crews and reduce outage durations. With a line current measurement accuracy of 1.5 percent, it enables effective switching decisions, letting you restore power to more customers. The flexible design makes the SEL-8301 ideal for underground vaults, pad-mounted switchgear and transformers, and high-rise distribution feeders and transformer rooms.
Compatible With RadioRANGER®
Starting price: $120 USD
The SEL-ARU is a reliable, settings-free fault indicator that automatically selects a minimum trip threshold based on the sampled load current. This feature simplifies ordering and inventory, reduces maintenance, and simplifies applications. The Dynamic Delayed Trip feature automatically adjusts the trip response time to better coordinate with upstream protection, maximize performance, and increase the reliability of underground distribution systems.
Display options provide flexibility for pad-mounted or vault installations. The power options (line-powered or battery) and restoration reset features ensure reliable performance for any application.
Image description: Image of SEL-ARU with integrated display. Image of SEL-ARU with fiber-optic display. Other display options are available.
Compatible With RadioRANGER®
Starting price: $72 USD
The SEL-TPR is an underground fault indicator that attaches to capacitive test points in single- or three-phase systems. It replaces the protective cap on capacitive test points, with the benefit of providing fault indication. The SEL-TPR eliminates the need to account for the position of the concentric neutral, as is common with cable-mounted fault indicators. It automatically resets upon system voltage restoration. The SEL-TPR is easy to install with a hot stick attached to its molded rubber hook eye. Powered by line voltage, the SEL-TPR does not have a minimum current requirement, making it great for lightly loaded circuits.
You can choose from a variety of display options, including a built-in, battery-free mechanical flag display or a remote bright BEACON® LED display. Remote display options reduce fault-finding times by eliminating the need for crews to open medium-voltage enclosures during patrols.
Compatible With RadioRANGER®
Starting Price: $110 USD
The SEL-CR uses continuous load current to automatically reset so it is ready to respond to faults. Powered by the load current on an energized underground distribution cable, the SEL-CR responds to a fault and remains in the faulted-display condition until the line is energized with normal line load.
Starting Price: $88 USD
Apply the SEL-SR in single- and three-phase pad-mounted transformer applications where there is insufficient load current or no capacitive test points to power fault indicators. The SEL-SR's reset cable feeds off the transformer secondary voltage to operate, eliminating the need for a battery.
Starting Price: $120 USD
The SEL-TR holds its tripped status indication for a set time, regardless of the presence of current or voltage on the distribution circuit, making it ideal for underground systems. You can use this functionality for applications where backfeed voltage or current can falsely reset restoration-reset faulted circuit indicators in the fault path. The SEL-TR is available with a long-lasting nonreplaceable battery for installations that require zero maintenance.
Starting Price: $350 USD
More economical than a PT or analog sensor, the SEL-MW detects system voltage loss where exact system voltage measurement reporting is not required. You can easily install the SEL-MW on capacitive test points of distribution elbows. It learns and adapts to the unique voltage output level of the capacitive test points to simplify product calibration.
Compatible With RadioRANGER®
Starting price: $620 USD
SEL-PILCs support a wide range of paper-insulated lead-covered cable (PILC) configurations and applications, including triplexed, single-phase, and three-phase sector (or round) cables from 5.58 to 11.78 cm (2.2 to 4.64 in.) in diameter. A split-core design lets you quickly and easily install the SEL-PILC without disconnecting the cable. Its rugged construction can withstand submersion in up to 4.5 m (15 ft) of water. The SEL-PILC is compatible with the RadioRANGER Underground Wireless Fault Indication System. Together, they make it easier and faster to find faults on urban systems.
Starting price: $220 USD
The SEL-GFD detects ground faults by sensing the vector sum of the current flowing through a three-conductor cable. You can install the split-core sensor on three-phase cables or a bundle of three single-phase cables without opening the primary. Three reset options are available: secondary voltage, load current, or time.
Choose from a variety of display options, including nonbattery mechanical flag displays and bright BEACON® LED displays. Remote displays eliminate the need for crews to open high-voltage enclosures or enter subsurface vaults, improving fault-finding times and reducing arc-flash risks.
Image description: Images of various remote display options including Standard "V" Display, Large "L" Display, BEACON Bolt® Display, Tamperproof Bolt Display, and BEACON Fiber-Optic Display. Also shows the SEL-8310 RadioRANGER® Remote Fault Reader.
Starting price: $150 USD
SEL-CTs are designed for applications where it is difficult or uneconomical to open the primary conductor to install a solid-core-type current transformer. The flexible split-core design uses M-6 silicon steel formed into a hexagonal or rectangular shape. This allows you to open the core to install it over cables. The SEL-CT is encapsulated in a flexible vinyl plastic with 600 V-class insulation. The secondary terminals and hardware are nickel-plated brass.
Starting price: $220 USD
SEL-SCTs are designed for applications where it is difficult or uneconomical to open the primary conductor to install a solid-core-type CT. The separable-core design allows you to open the SEL-SCT to the nominal window diameter and install it over bushings or cables without interrupting the connection. SEL-SCTs are held in place with cable ties. The submersible design provides reliable use in subsurface vaults where flooding can occur.
The SEL-SCT is encapsulated in flexible vinyl plastic with 600 V-class insulation and consists of a separable two-part assembly. The SEL-SCT base and body can be pulled apart, placed around a cable, and reconnected. Two included stainless-steel worm gear clamps secure the base and body of the CT while also preventing water intrusion into the CT core.
![]() |
2022 Product and Solution Guide | Schweitzer Engineering Laboratories Explore Schweitzer Engineering Laboratories' (SEL) comprehensive range of products and solutions for electric power systems, including protection, automation, control, and metering for generation, transmission, distribution, and industrial applications. Discover advanced technologies and services to enhance grid reliability and safety. |
![]() |
SEL-2440 Discrete Programmable Automation Controller Data Sheet This document provides detailed specifications and features of the SEL-2440 Discrete Programmable Automation Controller (DPAC), including its I/O capabilities, communication protocols, automation features, and compliance standards. |
![]() |
SEL Automation and Computing Platform Accessories This document details a range of accessories for SEL automation and computing platforms, including rack-mount keyboards, touchscreen monitors, memory modules (RAM), solid-state drives (SSDs), power supplies, expansion cards, and cables and adapters. It provides specifications, part numbers, and ordering information for each product. |
![]() |
SEL Digital Secondary System Solutions: TiDL and SV Technologies for Substation Automation Discover how Schweitzer Engineering Laboratories (SEL) enhances substation safety, reduces costs, and improves reliability with digital secondary system solutions like TiDL and SV technologies. Learn about their benefits, architecture, and product offerings for modernizing substations. |
![]() |
SEL Automation Controller Platform Accessories Explore Schweitzer Engineering Laboratories' comprehensive range of accessories designed to enhance automation controller platforms. This catalog details peripherals, components, power supplies, expansion cards, enclosures, and cables, providing essential solutions for industrial automation projects. |
![]() |
SELect I/O Cards: Part Numbers and Compatibility Guide | Schweitzer Engineering Laboratories Explore the comprehensive range of SELect I/O Cards from Schweitzer Engineering Laboratories. This guide details part numbers, product compatibility, and ordering information for various digital and analog I/O modules compatible with SEL substation automation devices. |
![]() |
SEL-300G Generator Relay: Protect, Monitor, and Control Your Generator The SEL-300G Generator Relay by Schweitzer Engineering Laboratories offers comprehensive protection, monitoring, and control for small, medium, and large generators. It features advanced fault detection, event analysis, remote communication, and system backup capabilities, enhancing generator availability and operational safety. |
![]() |
SEL-751 Feeder Protection Relay: Features, Specifications, and Applications Comprehensive overview of the SEL-751 Feeder Protection Relay, detailing its key features, advanced protection capabilities, sensor inputs, communication protocols, and applications in electrical power systems. Learn about its arc-flash detection, cold-load pickup, and automation features. |