Instruction Manual for Blue White models including: F-451-006, F-451-001, F-451-002, F-451-003, F-451-004, F-451 Flow Meter, F-451, Flow Meter, Meter
F-451 Bedienungsanleitung - 80000-247 - Blue-White Branchen
F-451 - Blue-White Branchen
File Info : application/pdf, 16 Pages, 1.46MB
DocumentDocumentOperating Manual F-451 Flow Meter ® READ THE ENTIRE OPERATING MANUAL PRIOR TO INSTALLATION AND USE. +1 (714) 893 - 8529 sales@blue-white.com customerservice@blue-white.com 5300 Business Drive Huntington Beach, CA 92649 2 Table of Contents 1.0 Introduction 1.1 What's in the box 1.2 Features 1.3 Application Notes 1.4 Ordering Information / Product Matrix 2.0 Engineering Specifications 2.1 Flow Meter Specifications 2.2 Materials of Construction 2.3 Flow vs. Pressure Graph 2.4 Flow Specifications 2.5 Dimensions 3.0 Installation 3.1 Installation Requirements 3.2 Tools Required 3.3 Installation Instructions 3.4 Installing Polycarbonate Shield 4.0 Reading your Flow Meter 5.0 Maintenance and Troubleshooting 6.0 Spare Parts 7.0 Warranty 5 5 5 5 6 6 6 7 7 7 8 8 8 8 9 10 11 12 12 15 3 SAFETY INFORMATION Please read this manual completely before unpacking, installing, and operating this equipment. In particular, pay attention to all dangers, warnings, and precautions, otherwise, it may cause serious injury to the operator or damage to the equipment. Note: When in doubt regarding your electrical installation, contact a licensed electrician. 4 F-451 1.0 Introduction Congratulations on purchasing the F-451 Flow Meter! Your Flow Meter is calibrated and ready for use. The unit is designed to give many years of service. For more information or questions on this product or any of our Industrial products, please visit us at www.blue-white.com 1.1 What's in the box · Flow meter (1) (Flow meter may contain plastic tubing for protection during shipping. Remove before installation.) · Quick Start Guide Check all packaging for completeness and inspect for damage before installation. 1.2 System Features · Dual Scale (GPM / LPM), screen printed for easy reading · Tested and calibrated for clean water applications · Durable Polysulfone body · In-line or Panel Mount options · Optional Polycarbonate Shield available · Unionized threaded adapters for simple installation and service · Not for use in direct sunlight · Upward flow, vertical installation only 1.3 Application Notes Although meters may be suitable for other chemicals, Blue-White cannot guarantee their suitability. It is the responsibility of the user to determine the suitability of the flow meter in their application. Flow meters are tested and calibrated for water only. 5 F-451 1.4 Ordering Information / Model Number Matrix F Flow Meter Series 451 F-451 Polysulfone body Scale 006 0.5 - 6 gpm (2 - 22 lpm) Teflon Float 001 1 - 10 gpm (4 - 40 lpm) 316ss Float 002 2 - 20 gpm (6 - 76 lpm) 316ss Float 003 3 - 30 gpm (12 - 115 lpm) 316ss Float 004 4 - 40 gpm (15 - 155 lpm) 316ss Float Guide-Wire Material LHN 316 Stainless steel rod Special (Blank) Standard meter Adapter (Blank) 1.0" Female NPT, Polysulfone -24 1.5" Female NPT, PVC E 90° Elbow 1.0" Male NPT , Polysulfone O-Ring (Blank) Viton -22R EP F - 451 006 LHN Sample Model Number 2.0 Engineering Specifications 2.1 Flow Meter Specifications Maximum Working Pressure 150 PSI (10.3 bar) @ 70 °F (21 °C) Maximum Fluid Temperature Standard units - 1" pipe: 212 °F (100 °C) @ 0 PSI Standard units - 1-1/2" pipe: 120 °F (49 °C) @ 0 PSI Full Scale Accuracy +/- 3% P.N. #C83a00li0b-0r3a9 tiFo-4n51FRluEVid7 20231211 Water, specific gravity 1.0 5300 Business Drive, Huntington Beach, CA 92649 TEL S71c4-a8l9e3-8L5e2n9 g| FtAhX 714-894-9492 | www.blue-wh6it"e.(c1o5m0| msamles)@blue-white.com Environment Not for direct sunlight exposure Maximum Pressure Drop 1 PSI Approximate Shipping Weight 3 lb. (1.36 kg) 6 2.2 Materials of Construction Wetted Components: Meter Body Polysulfone Adapters 1" pipe: Polysulfone, F/NPT or elbow M/NPT 1.5" pipe: PVC, F/NPT Guide Rod Holder Polysulfone O-ring Seals Viton® (optional EP) Float 316SS or PTFE (varies per model) Guide Rod 316SS Optional Shield Polycarbonate 2.3 Temperature vs. Pressure Graph TEMPERATURE 230°F / 110°C 210°F / 99°C 190°F / 88°C 170°F / 77°C Polysulfone Fittings 150°F / 66°C 130°F / 54°C 110°F / 43°C 90°F / 32°C PVC Fittings 70°F / 21°C 0 / 0 30 / 2.1 60 / 4.1 90 / 6.2 PSIg / BAR 2.4 Flow Specifications 120 / 8.3 150 / 10.3 F-451 Model F-451006L F-451001L F-451002L F-451003L F-451004L GPM 0.56 1.010 2.020 3.030 4.040 Feed Rate LPM 222 440 676 23115 15155 Max Pressure PSI (bar) 150 (10.3) 150 (10.3) 150 (10.3) 150 (10.3) 150 (10.3) Max Temperature °F (°C) 70 (21) 70 (21) 70 (21) 70 (21) 70 (21) Float Material Teflon 316SS 316SS 316SS 316SS 7 F-451 2.5 Dimensions A Dim Inch cm A 14-1/2" 36.83 B 3-5/16" 8.41 Vertical In-line Models Dim Inch cm A 3-5/16" 8.41 B 15" 38.1 C 17" 43.18 CB Panel Mount Elbow Models 3.0 Installation 3.1 Installation Requirements Before beginning installation, review your system flow and pressure to ensure your F-451 is proper for your system parameters. Pipe Requirements: · The flow meter is designed to work best when installed in a perfectly vertical pipe system. · Ensure piping design prevents any stress on the meter fittings, minimizes vibration, and ensures location with direct visibility and minimal possibility of damage from forcible contact. · Pipe should be clean and free of debris. · Connecting pipe should be uniform and not warped. · Pipe must be properly supported even during maximum water flow conditions. · Don not install in direct sunlight. · Use of unionized fittings before and after the flow meter will allow for easier installation and removal for maintenance. · On/Off solenoid valves and pumps installed before the flow meter should be accompanied by flow regulating/throttling valves, or similar device, to prevent sudden and forcible flows through the flow meter which can cause damage to flow meter components. · Choose location where pipe will be full at all times. 3.2 Tools Required · PTFE Tape · Level Note: Keep flow meter away from pipe glue fumes. Ensure all pipe glue is dry before installation flow meter. Pipe glue solvents will damage meter. 8 F-451 Always wear protective clothing, face shield, safety glasses and gloves when working on your equipment. Use caution when lifting and mounting equipment. When in doubt, contact factory for assistance. 3.3 Installation Instructions 1. The flow meter must be installed in a vertical plane to ensure accuracy. Misalignment may damage the flow meter and also may cause the o-ring seals to leak. The meterbody material can be damaged by UV rays. Do not install in direct sunlight. 2. Use only PTFE tape on the threaded adapters. Pipe dope and glue will damage the meter body and fittings. Or install the flow meter after all glued fittings have dried and fumes have been purged from the system. Never hold the meter body with pliers or like tools. Union nuts should be hand tightened only. DO NOT OVER-TIGHTEN! 3. Mounts and supports must be sturdy enough to support the plumbing and prevent vibration. Vibration and heavy loads will damage the meter. 4. Avoid imposing a sudden burst of flow to the meter. Solenoid valves will damage the meter. Such a burst will cause the float to impact the top float stop with destructive force. 5. The Maximum fluid temperature is dependent on the working pressure. High pressure and temperature will damage the meter. (see temperature VS pressure chart) 9 F-451 3.4 Polycarbonate Shield Installation Instructions Use these instructions if you have purchased the optional Polycarbonate Shield Kit, KIT-SHS. 1. Unpack the KIT-SHS. The kit includes shield and two adapter rings. Ensure all components are present and in good shape. The flow meter must be dis-assembled to install the shield. 2. Unscrew top union nut and remove. Place meter on flat surface. 3. Snap shield adapter rings onto union nuts. One adapter ring will need to slide over the meter body and onto bottom union nut. 4. Keep top meter adapter, O-ring, wire holder, guide rod in place if using in-line flow meter. It using elbow adapters, it will be necessary to remove top adapter when placing shield. 3 3 10 5. Place shield over the meter body and onto the adapter ring. 6. With the top adapter in place, put other union nut / adapter ring onto top of meter body and shield. (Be sure shield fits into adapter rings properly without bending) 7. Hand tighten union nuts. The flow meter is ready for service. F-451 5 6, 7 11 F-451 4.0 Reading your F-451 Flow Meter Avoid imposing a sudden burst of flow to the meter. Solenoid valves may cause the float to impact the top float stop with destructive force. Always read float at top. 5.0 Maintenance and Troubleshooting · The F-451 Flow Meter requires very little maintenance. However, the flow meter may become clogged due to excess debris in the water. If this happens, simply shut of the process pump or valve and remove any pressure from the piping. If isolation valves are installed, shut these to minimize the amount of water that may leak. Locate nearest unions on piping to allow for removal of flow meter. The F-451 Flow Meter may also be removed by unscrewing the flow meter union nuts. Remove the flow meter and clean any debris in the flow meter. Use mild soap and a soft bristle brush. · Reinstall the flow meter and test. If the float was removed during the cleaning process, ensure the float was reinstalled properly. The float is wider at the top. · If flow meter requires NIST Calibration Certification, please contact the factory for this service. 12 Page 2 F-451 F-451 F-451 INSTA6LL.0ATSIOpNaGrUeIDPE arts 1 The flowmeter must be installed in a vertical plane to ensure accuracy. MisalignmenIttemm ayModdaelmNaog. e thPerodfuloctwNmameteer and also may cause the o-ring seals to leak. 3 Qty. Req. 1 F-45038N Union Nut 2 2 Use only PTFE tape on the threaded adapters. Pip2e doFp-4e50a3n0dN glueAdwaiplltedr,avmeratigcael, 1" F/NPT (PSF) 2 itnhsetaplol ltyhseulffloonwemmeFtee-t4re5r0a3bft6oedr yalal nAMgdd/lNuafpePittTdteinr(,PfgvitVsetiCr.nti)Ocgasrl, 1-1/2" 2 have dried an3d fuF-m45e0s25have Wbeirehnoldpeurr1g-e10d, 2-20 (PSF) from the system. F-45025-2 2 LG Wireholder 3-30, 4-40 (PSF) 2 2 1 3 Mounts and4 su2p-1p36oVrts musOt-Rbineg 2s-t1u3r6d(yViton) 2 enough to support the plumbing and prevent vibratio2n-1. 36VEibBrationO-aRnindg 2h-1e3a6v(EyP) loads will dama5ge 2th-0e0m6Aeter. Float Stop .5-6, 1-10, 2-20 (Aflas) 2 3 4 Avoid imposin2g-0a06sEudden bFluoartsSt toopf f.5lo-6w, 1-10, 2-20 (EP) 2 tthoetmheetmere. Steurc. hSaolb2e-un0ro0s8itdVwvilal lcvaeusL(sAawefrlgaitlehsl )edFlafolmaotaaStgttooep, 3-30, 4-40 2 4 impact force. the top float stop 2-008E withLardgee sFtlrouact tSivtoep, 3-30, 4-40 (EP) 6 - Float (SS) (contact factory) 2 1 5 The Maximum fluid temperature is dependant on7 the wor-king prMeestseurbroed.yH(PigShF) (contact factory) mpreetsesru. (rseeaentdem8tepmeprFa-e4tru5ar0te2u8VreSwpirtehGsdusiaudmereWacgihreea, rt.t5h)-e6, 1-10, 2-20, (SS) 1 1 5 F-45028-2 Guide Wire, 3-30, 4-40 (SS) 1 EXPLODED VIEW, PARTS LIST AND S EXPLODED VIEW 1 2 3 4 5 6 7 8 5 9 Item Catalog 1 F-45038N 2 F-45030N F-45036 A 3 F-45025 F-45025-2 4 2-136V 5 2-006A 2-008V 6 - 7 - 8 F-45028 F-450028-2 9 F-45046 F-45054 Shading in *Hastelloy C-276 Option A **EP Option Available M Scale Max Pressure Max Temperature Height Width Accuracy 9 F-45046 Wireholder Bottom (PSF) 1 TEMPERAT10URFE-45v0s31PRES1P"oSMlyUsauleRlfoNEnPeT 90° Elbow, 2 Temperature 11 F-45032 Panel Mount Lock Nut, PVC 2 230°F / 110°C 210°F / 98.9°C 190°F / 87.7°C 170°F / 76.6°C 150°F / 65.6°C 130°F / 54.4°C 110°F / 43.3°C 90°F / 32.2°C 70°F / 21.1°C MMMOOODDDEEELLLSSMSWWOWDIITITTEHHHLPSPPOVWOLCLIYTYASHSUDUBLALRFPFAOOTSNENSEREAASADDDAAAPPTPTETERERSRSS 0 / 0 30 / 2.1 60 / 4.1 90 / 6.2 120 / 8.3 PSIg / BAR 11 APPL1ICATION NOTES 10 Although meters may be suitable for other guarantee their suitability. It is the responsibi suitability of the flowmeter in their applicatio calibrated for water only. Panel Mount Elbow Option MAINTENANCE 150 / 10.3 The "Exploded View" drawing illustrates a meter. If your flowmeter needs to be clean reassembling the unit. The tapered tube ma brush. Use a MILD soap and water solution f float's "up" position. 13 F-451 Notes: 14 7.0 WARRANTY F-451 7.1 LIMITED WARRANTY Your new Flow Meter is a quality product and is warrantied for 12 months from date of purchase (proof of purchase is required). The unit will be repaired or replaced at our discretion. Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in the manual. Warranty status is determined by the serial label and the sales invoice or receipt. The serial label must be on the unit and legible. The warranty status of the unit will be verified by Blue-White or a factory authorized service center. 7.2 WHAT IS NOT COVERED · Wear items. · Unit removal, or re-installation, and any related labor charge. · Freight to the factory, or service center. · Units that have been tampered with, or in pieces. · Damage to the unit that results from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of maintenance, or alteration which is out of our control. · Units damaged by faulty wiring, power surges or acts of nature. 7.3 PROCEDURE FOR IN WARRANTY REPAIR Contact the factory to obtain a RMA (Return Material Authorization) number. Carefully pack the unit to be repaired. Please enclose a brief description of the problem as well as the original invoice or sales receipt, or copy showing the date of purchase. Prepay all shipping costs. COD shipments will not be accepted. Warranty service must be performed by the factory or an authorized service center. Damage caused by improper packaging is the responsibility of the sender. When In-Warranty repair or replacement is completed, the factory pays for return shipping to the dealer or customer. 7.4 PRODUCT USE WARNING Blue-White products are manufactured to meet the highest quality standards in the industry. Each product instruction manual includes a description of the associated product warranty and provides the user with important safety information. Purchasers, installers, and operators of Blue-White products should take the time to inform themselves about the safe operation of these products. In addition, Customers are expected to do their own due diligence regarding which products and materials are best suited for their intended applications. Blue-White is pleased to assist in this effort but does not guarantee the suitability of any particular product for any specific application as Blue-White does not have the same degree of familiarity with the application that the customer/end user has. While Blue-White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties. BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION. 7.5 CHEMICAL RESISTANCE WARNING Blue-White offers a wide variety of wetted parts. Purchasers, installers, and operators of Blue-White products must be well informed and aware of the precautions to be taken when injecting or measuring various chemicals, especially those considered to be irritants, contaminants or hazardous. Customers are expected to do their own due diligence regarding which products and materials are best suited for their applications, particularly as it may relate to the potential effects of certain chemicals on Blue-White products and the potential for adverse chemical interactions. Blue-White tests its products with water only. The chemical resistance information included in this instruction manual was supplied to Blue-White by reputable sources, but Blue-White is not able to vouch for the accuracy or completeness thereof. While Blue-White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties. BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE USE OF CHEMICALS IN CONNECTION WITH ANY BLUE-WHITE PRODUCTS. 15 P.N. 80000-247 F-451 Flow Meter REV 9 20240506 5300 Business Drive, Huntington Beach, CA 92649 TEL 714-893-8529 | FAX 714-894-9492 | www.blue-white.com | sales@blue-white.com