Lumie Bodyclock Glow 150
User Manual
Safety Information
If the unit is damaged, contact Lumie before use. Keep away from water and damp. For indoor use only. The unit gets warm when the light is on, so make sure that it is not covered. Use only the mains power adaptor supplied. Keep the mains power adaptor and cable away from heated surfaces. If either are damaged, they should be replaced with an approved Lumie product. This appliance does not have a on/off switch. To power down or reset, remove the mains power adaptor from the wall socket. You should therefore ensure the socket is easily accessible. Only to be used by adults and by children when supervised. Do not attempt to service or modify any part of the unit. If the unit has been stored outside the recommended operating temperature range (5 °C to 35 °C), allow it to stand for at least 1 hour before applying power to avoid condensation or overheating.
Not to be used by or on individuals who are unconscious, anaesthetised or incapacitated e.g. under the influence of alcohol.
Electromagnetic compatibility
This product conforms to the electromagnetic compatibility (EMC) standard for medical devices and is unlikely to cause interference affecting other electrical and electronic products in its vicinity. However, radio transmitting equipment, mobile phones and other electrical/electronic equipment can interfere with this product; if this happens simply move the product away from the source of interference. In rare cases where product function is lost due to EMC effects, disconnect the product from the power source for 5 seconds and then restart. If the problem persists, please contact Lumie.
For further detailed information on the electromagnetic environment in which the device can be operated refer to the website: www.lumie.com/pages/e-m-c.
Disposal
Do not throw out the mains power adaptor or the unit with normal domestic waste. Take them to an official recycling point to be disposed of responsibly.
| Symbol | Meaning |
|---|---|
| [Serial Number] | Serial number |
| CE | European Declaration of Conformity: Medical Device Class I |
| MD | Medical Device |
| [Unique Device Identifier] | Unique Device Identifier |
| [information] | Read instructions for use |
| [keep dry] | Keep dry |
| [for indoor use only] | For indoor use only |
| [caution] | Caution |
| [do not place in household waste] | Do not place in household waste. Dispose of at a recycling centre. |
| [green dot recycling scheme] | Member of the 'Green Dot' recycling scheme |
| [recyclable] | Recyclable |
| [double-insulated (Class II electrical)] | Double-insulated (Class II electrical) |
| [DC (direct current) power supply] | DC (direct current) power supply |
| [storage/transport relative humidity] | Storage/transport relative humidity |
| [storage/transport temperature] | Storage/transport temperature |
| UK CA | UK Conformity Assessed |
Introduction
Lumie Bodyclock wakes you naturally with a sunrise. Waking with light has been shown to improve mood, energy, productivity and the quality of sleep and awakening.1
Wake-up lights can also help sufferers of SAD (Seasonal Affective Disorder) and winter blues cope with dark winter mornings.2
At bedtime, a fading sunset helps you naturally unwind by promoting the production of the sleep hormone, melatonin.3
Use Lumie Bodyclock all year round to encourage a regular sleep-wake pattern.
Research shows that dawn simulation is very safe and without serious side-effects. If you have any concerns, please contact Lumie or speak to your doctor.
1 Acta Psychiatr Scand. 1993 Jul;88(1):67-71. 2 J Affect Disord. 2015 Jul 15;180:87-9. 3 Sleep Biol Rhythms. 2016 Jan;14(1):47-53.
Getting Started
The ideal place for Lumie Bodyclock is on a bedside table near a mains socket.
- Connect the mains power adaptor to the socket in the base of the unit.
- Plug into a mains power supply.
The display will flash until the current time is set:
Program
- The hours will flash.
- Use [minus] or [plus] to set the hours.
- Press [confirm] to confirm and continue.
- The minutes will flash.
- Use [minus] or [plus] to set the minutes.
- Press [confirm] to confirm and exit to the current time.
Bodyclock Glow 150 is preset with a 07:00 alarm time, 30-minute sunrise and 30-minute sunset.
To use it with these settings see Using the sunrise alarm, page 10, and Using the fading sunset, page 11.
To change the alarm time or any other settings read the following sections.
Alarm Time and Sunrise Options
Press and hold [alarm symbol].
A symbol on the display shows which option you're setting. Continue through the following sequence to set the alarm time and sunrise options:
- Alarm time
- Use [minus] or [plus] to set the hours.
- Press [confirm].
- Use [minus] or [plus] to set the minutes.
- Press [confirm] to confirm and continue.
- Sunrise light intensity
- Use [minus] or [plus] to set the final brightness of the sunrise: 0 for no sunrise or a level from 1 to 5.
- Press [confirm] to confirm and continue.
- Sunrise duration
Only available if you have set a sunrise light intensity.
- Use [minus] or [plus] to set the duration of the sunrise: 20, 30, or 45 minutes.
- Press [confirm] to confirm and continue.
- Wake sound
- Use [minus] or [plus] to set a wake sound for the end of the sunrise: No wake sound, Beep, Tropical birds, Blackbird, Cafe, Goats, Steam train, Thunderstorm, Waves, Crickets, White noise.
- If you set the sunrise light intensity to 0 you have to set a wake sound instead.
- Press [confirm] to confirm and continue.
Volume Settings
- Volume
Only available if you have set a wake sound.
- Use [minus] or [plus] to set the volume: 0 for off or a level from 1 to 5.
- Press [confirm] to confirm and exit to the current time.
Sunset Options
Press and hold [sunset symbol].
A symbol on the display shows which option you're setting. Continue through the following sequence to set the sunset options:
- Sunset duration
- Use [minus] or [plus] to set the duration of the sunset: 20, 30 or 45 minutes.
- Press [confirm] to confirm and continue.
- Nightlight
- Use [minus] or [plus] to set a nightlight: 0 for no nightlight (sunset fades to off) or a level from 1 to 5 (sunset fades to nightlight).
- Press [confirm] to confirm and continue.
- Sleep sound
- Use [minus] or [plus] to set a sleep sound during the sunset: No sleep sound, Tropical birds, Blackbird, Cafe, Goats, Steam train, Thunderstorm, Waves, Crickets, White noise.
- Press [confirm] to confirm and continue.
- Volume
Only available if you have set a sleep sound.
- Use [minus] or [plus] to set the volume: a level from 1 to 5.
- Press [confirm] to confirm and exit to the current time.
Display Brightness
The display automatically adjusts to match the light level in your room when the room is dark and drops to low brightness when you're ready to sleep.
You can change this setting if you prefer the display to turn off completely when the room is dark.
- Use the switch in the base of the unit to set OFF or LOW:
Description of switch: The switch is located on the base of the unit. It has two positions: 'LOW' and 'OFF'. The 'LOW' setting dims the display in the dark, while the 'OFF' setting turns it off completely.
To check the time when the display is off
- Tap the top of the lamp cover. The display will change to low brightness for a few seconds.
Changing the Current Time
Bodyclock Glow 150 will keep time for 30 minutes without power. All other settings are permanently saved.
- Press and hold [confirm symbol] until [alarm symbol] appears.
Continue through the following sequence to set the time:
Program
- The hours will flash.
- Use [minus] or [plus] to set the hours.
- Press [confirm] to confirm and continue.
- The minutes will flash.
- Use [minus] or [plus] to set the minutes.
- Press [confirm] to confirm and exit to the current time.
Bedside Light
Lumie Bodyclock can be used as a fully dimmable bedside light.
- Use [minus] or [plus] to set the light level.
- Press and hold [minus symbol] to turn off the light.
Timeout: If the bedside light is not turned off manually, the light will turn off automatically after 12 hours.
Using the Sunrise Alarm
You must activate the alarm before you go to sleep each time.
To wake with a sunrise alarm
- Press [alarm symbol].
The display confirms the alarm time and shows [alarm symbol] to confirm the alarm is activated; for example: [07:30] [alarm symbol]
You'll wake with a gradual sunrise and any other sunrise options you have set. See also Alarm time and sunrise options, page 5.
To deactivate the sunrise alarm
- Press [alarm symbol]. [alarm symbol] disappears from the display.
To snooze
- Tap the top of the lamp cover. The sunrise, and alarm sound if set, will repeat after 9 minutes.
Turning Off Sunrise and Alarm
- Press any button. [alarm symbol] disappears from the display.
- Press and hold [minus symbol] to turn off the light.
Timeout: If the light and alarm sound are not turned off manually, they will turn off automatically after 90 minutes.
Using the Fading Sunset
When you're ready to sleep, a fading sunset can help you to relax and unwind. See also Sunset options, page 7.
To activate the sunset
- Use [minus] or [plus] to set the light level.
- Press [sunset symbol].
The display shows [sunset symbol] to confirm the sunset is activated: [22:59] [sunset symbol]
The light will start to fade and any other sunset options you have set will be activated.
To deactivate the sunset
- Press [sunset symbol]. [sunset symbol] disappears from the display.
Maintenance
Clean only with a dry or lightly moistened cloth. Always unplug the unit first and let it cool if necessary.
Replacement mains power adaptors are available from Lumie.
To restore the default factory settings
- Turn off the power at the mains.
- Press and hold [confirm symbol] and turn the power back on.
- Release the button when the software version number shows.
LED Lifetime
The LEDs in this product will typically last for many years, even with several hours use each day. Although it's unlikely, it's possible for individual LEDs to fail. If this happens, contact Lumie; do not attempt to replace them.
Warranty
This unit is covered under warranty against any manufacturing defect for 3 years from the date of purchase. This is in addition to your statutory rights. If you need to return the product for servicing, use the original packaging (including internal packing) if possible. Make sure the mains power adaptor is prevented from moving in transit and damaging the unit. If the unit is received damaged, through misuse or accidental damage, then Lumie may have to charge to repair it; they will contact you first. Please contact Lumie for further advice.
Note: Any serious incident relating to the unit should be reported to Lumie and to the competent authority in the country where you live.
Technical Description
Subject to change without notice.
Bodyclock Glow 150
Detachable accessory: Mains power adaptor (supplied): Input: 100–240 Vac, 50/60 Hz, 1 A max.; Output: 15 V ⎓ 1 A (15 W)
Operating conditions:
- Temperature: 5 °C to 35 °C
- Relative humidity: 15% to 93% (non-condensing)
- Atmospheric pressure: 70 kPa to 106 kPa
Storage/transport conditions:
- Temperature: -25 °C to +70 °C
- Relative humidity: 15% to 93% (non-condensing)
- Atmospheric pressure: 25 kPa to 106 kPa
Certifications:
- CE European Declaration of Conformity: Medical Device Class I
- UK Conformity Assessed
- MD Medical Device
Contact Us
If you have any questions or problems regarding this product, or have suggestions that you feel could help Lumie improve its products or service, please email info@lumie.com.
Lumie Address: Outside In (Cambridge) Limited, 3 The Links, Trafalgar Way, Bar Hill, Cambridge, CB23 8UD, UK.
Lumie is a registered trademark of: Outside In (Cambridge) Limited, incorporated in England and Wales. Registered Number: 2647359.
VAT No: GB 880 9837 71 (UK), NL 826301381B01 (EU)
EC Representative: Advena Ltd, Tower Business Centre, 2nd Floor, Tower Street, Swatar, BKR 4013 Malta.