Owner's Manual for MEAN WELL models including: SPV-300 300W Single Output With PFC Function, SPV-300, 300W Single Output With PFC Function, Output With PFC Function, With PFC Function, PFC Function, Function
MEAN-WELL USA, INC. - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 3 Pages, 107.72KB
DocumentDocument300W Single Output with PFC Function SPV-300 series Features : User's Manual Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC Fan Output voltage programmable from 20~110% by 1~5.5VDC external control signal Built-in remote ON-OFF control Built-in fan speed control Fixed switching frequency at 100KHz 3 years warranty GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 MODEL SPV-300-12 SPV-300-24 SPV-300-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 25A 12.5A 6.25A CURRENT RANGE 0 ~ 25A 0 ~ 12.5A 0 ~ 6.25A OUTPUT RATED POWER 300W RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE ADJ. RANGE 10.8 ~ 13.2V VOLTAGE TOLERANCE Note.3 ±1.0% LINE REGULATION ±0.3% LOAD REGULATION ±0.5% SETUP, RISE TIME 800ms, 50ms/230VAC 300W 150mVp-p 20 ~ 26.4V ±1.0% ±0.2% ±0.5% 2500ms, 50ms/115VAC at full load 300W 240mVp-p 41 ~ 52.8V ±1.0% ±0.2% ±0.5% HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 124 ~ 370VDC INPUT POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load 83.5% 85% 3.6A/115VAC 1.8A/230VAC 20A/115VAC 45A/230VAC 86.5% LEAKAGE CURRENT <1mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 13.8 ~ 16.2V 27.6 ~ 32.4V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down REMOTE CONTROL FUNCTION OUTPUT VOLTAGE TRIM WORKING TEMP. 4 ~ 10VDC power off, <0 ~ 0.8VDC power on 2.4 ~ 13.2V 4.8 ~ 26.4V -20 ~ +65 (Refer to "Derating Curve") 9.6 ~ 52.8V ENVIRONMENT WORKING HUMIDITY STORAGE TEMP., HUMIDITY 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV BS EN/EN60950-1, EAC TP TC 004 approved SAFETY EMC (Note 4) WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 OTHERS EMC IMMUNITY MTBF DIMENSION Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 2116.3K hrs min. Telcordia SR-332 (Bellcore) ; 210.6K hrs min. MIL-HDBK-217F (25) 215*115*50mm (L*W*H) NOTE PACKING 1.1Kg; 12pcs/14Kg/0.92CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:SPV-300-SPEC 2024-02-27 135 300W Single Output with PFC Function Mechanical Specification 117.5 32.5 27.5 19 150 177.5 SUPSVP--33202005 sseerriieess Case No. 912G Unit:mm 36.7 95 9.5 115 50 +V ADJ. 9 8 7 6 5 4-M4 L=5mm 48.7 4 3 2 5-M3 L=3mm 1 50.5 8 37.5 32.5 10 5 16 15 32.5 14 max. Block Diagram I/P EMI FILTER FG Derating Curve 215 150 ACTIVE INRUSH CURRENT LIMITING RECTIFIERS O.L.P. O.T.P. 6-M4 L=5mm POWER SWITCHING 25 50 Air flow direction Terminal Pin No. Assignment : Pin No. Assignment Pin No. 1 AC/L 5 2 AC/N 6~7 3 FG 8~9 4 RC Assignment PV DC OUTPUT -V DC OUTPUT+V FAN SPEED CONTROL RECTIFIERS & FILTER fosc : 100KHz FAN +V -V DETECTION PV PWM & PFC CIRCUIT CONTROL O.V.P. RC Static Characteristics 100 80 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 100 300 90 250 80 200 70 150 60 100 50 50 40 25 88 90 95 100 115 135 155 175 195 INPUT VOLTAGE (VAC) 60Hz 230 264 File Name:SPV-300-SPEC 2024-02-27 LOAD (%) LOAD (%) Downloaded from Arrow.com. 300W Single Output with PFC Function SUPSVP--320205 sseerriieess Function Manual 1.External Voltage Control Vout 120 +V 100 100 +V -V -V LOAD 80 Non-Linear 80 60 60 OUTPUT VOLTAGE (%) OUTPUT CURRENT (%) PV 40 40 1~5.5V -V 20 20 V V 1 2 3 4 5 5.5 6 20 40 60 80 100 110 120 EXTERNAL VOLTAGE (DC) OUTPUT VOLTAGE (%) Downloaded from Arrow.com. File Name:SPV-300-SPEC 2024-02-27