300W Single Output with PFC Function

SPV-300 series

 Features :

User's Manual

Universal AC input / Full range

Built-in active PFC function, PF>0.95

Protections: Short circuit / Overload / Over voltage / Over temperature

Forced air cooling by built-in DC Fan

Output voltage programmable from 20~110% by 1~5.5VDC external control signal

Built-in remote ON-OFF control

Built-in fan speed control

Fixed switching frequency at 100KHz

3 years warranty

 GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION

Bauart gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000

MODEL

SPV-300-12

SPV-300-24

SPV-300-48

DC VOLTAGE

12V

24V

48V

RATED CURRENT

25A

12.5A

6.25A

CURRENT RANGE

0 ~ 25A

0 ~ 12.5A

0 ~ 6.25A

OUTPUT

RATED POWER

300W

RIPPLE & NOISE (max.) Note.2 150mVp-p

VOLTAGE ADJ. RANGE

10.8 ~ 13.2V

VOLTAGE TOLERANCE Note.3 ±1.0%

LINE REGULATION

±0.3%

LOAD REGULATION

±0.5%

SETUP, RISE TIME

800ms, 50ms/230VAC

300W 150mVp-p 20 ~ 26.4V ±1.0% ±0.2% ±0.5% 2500ms, 50ms/115VAC at full load

300W 240mVp-p 41 ~ 52.8V ±1.0% ±0.2% ±0.5%

HOLD UP TIME (Typ.)

16ms/230VAC 16ms/115VAC at full load

VOLTAGE RANGE Note.5 88 ~ 264VAC

FREQUENCY RANGE

47 ~ 63Hz

124 ~ 370VDC

INPUT

POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)

PF>0.95/230VAC PF>0.98/115VAC at full load

83.5%

85%

3.6A/115VAC 1.8A/230VAC

20A/115VAC 45A/230VAC

86.5%

LEAKAGE CURRENT

<1mA / 240VAC

OVERLOAD PROTECTION
OVER VOLTAGE

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

13.8 ~ 16.2V

27.6 ~ 32.4V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

REMOTE CONTROL FUNCTION
OUTPUT VOLTAGE TRIM WORKING TEMP.

4 ~ 10VDC power off, <0 ~ 0.8VDC power on

2.4 ~ 13.2V

4.8 ~ 26.4V

-20 ~ +65 (Refer to "Derating Curve")

9.6 ~ 52.8V

ENVIRONMENT

WORKING HUMIDITY STORAGE TEMP., HUMIDITY

20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL60950-1, TUV BS EN/EN60950-1, EAC TP TC 004 approved

SAFETY EMC
(Note 4)

WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020

OTHERS

EMC IMMUNITY MTBF DIMENSION

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 2116.3K hrs min. Telcordia SR-332 (Bellcore) ; 210.6K hrs min. MIL-HDBK-217F (25) 215*115*50mm (L*W*H)

NOTE

PACKING

1.1Kg; 12pcs/14Kg/0.92CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on

a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to

perform these EMC tests, please refer to EMI testing of component power supplies.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

 Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Downloaded from Arrow.com.

File Name:SPV-300-SPEC 2024-02-27

135

300W Single Output with PFC Function

Mechanical Specification

117.5

32.5 27.5 19

150 177.5

SUPSVP--33202005 sseerriieess
Case No. 912G Unit:mm

36.7

95

9.5

115

50

+V ADJ.

9

8

7

6

5

4-M4 L=5mm

48.7

4

3 2 5-M3 L=3mm

1

50.5

8

37.5

32.5

10

5

16

15 32.5 14 max.

Block Diagram

I/P

EMI FILTER

FG

Derating Curve

215 150
ACTIVE INRUSH CURRENT LIMITING

RECTIFIERS
O.L.P. O.T.P.

6-M4 L=5mm
POWER SWITCHING

25

50

Air flow direction

Terminal Pin No. Assignment :

Pin No. Assignment Pin No.

1

AC/L

5

2

AC/N

6~7

3

FG

8~9

4

RC

Assignment PV
DC OUTPUT -V DC OUTPUT+V

FAN SPEED CONTROL
RECTIFIERS &
FILTER

fosc : 100KHz FAN
+V -V

DETECTION

PV

PWM & PFC

CIRCUIT

CONTROL

O.V.P.

RC
Static Characteristics

100 80 60 40 20

-20

0

10

20

30

40

50

60

70 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100

300

90

250

80

200

70

150

60

100

50

50

40

25

88 90 95 100 115 135 155 175 195
INPUT VOLTAGE (VAC) 60Hz

230 264

File Name:SPV-300-SPEC 2024-02-27

LOAD (%) LOAD (%)

Downloaded from Arrow.com.

300W Single Output with PFC Function

SUPSVP--320205 sseerriieess

Function Manual
1.External Voltage Control

Vout

120

+V

100

100

+V

-V

-V LOAD

80

Non-Linear

80

60

60

OUTPUT VOLTAGE (%) OUTPUT CURRENT (%)

PV

40

40

1~5.5V

-V

20

20

V

V

1

2

3

4

5 5.5 6

20 40 60 80 100 110 120

EXTERNAL VOLTAGE (DC)

OUTPUT VOLTAGE (%)

Downloaded from Arrow.com.