User Manual for hoymiles models including: HRSD-2C, HT10, HT10-Kit, HRSD-2C Rapid Shutdown Solution, HRSD-2C, Rapid Shutdown Solution, Shutdown Solution, Solution

USER MANUAL

USER MANUAL - Hoymiles

31 ott 2022 — This manual contains important instructions for installation and maintenance of the Hoymiles product models HRSD-2C and the Transmitter.


File Info : application/pdf, 21 Pages, 3.47MB

PDF preview unavailable. Download the PDF instead.

User-Manual HRSD-2C Global EN V202210
Open Energy for All

Region: Global V202210

Rapid Shutdown
USER MANUAL
HRSD-2C HT10
HT10-Kit
hoymiles.com

Rapid Shutdown User Manual
CONTENTS

1. Products

01

1.1 HRSD-2C

01

1.2 HT10

02

1.3 HT10-Kit

03

2. System Overview

04

3. Installation Notes

05

4. Installation

06

4.1 HRSD-2C Installation

06

4.2 HT10 Installation

09

4.3 HT10-Kit Installation

12

4.4 Conduit Drilling Guide

15

5. Technical Specifiications

16

5.1 HRSD-2C

16

5.2 HT10

17

5.3 HT10-Kit

18

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

Rapid Shutdown User Manual
SAVE THESE INSTRUCTIONS
· This manual contains important instructions for installation and maintenance of the Hoymiles product models HRSD-2C and the Transmitter.
· Risk of electric shock, do not remove the cover, disassemble, or repair, no user-serviceable parts inside. If it fails, contact Hoymiles Customer Support. Damaging or opening the product will void the warranty.
· Before installing or using the Hoymiles HRSD-2C System, please read all instructions and warning markings on the Hoymiles products, relevant sections of your inverter manual, photovoltaic (PV) module installation manual, and other available safety guides.
· Failure to adhere to these instructions may result in injury or death, damage to the system or invalidating the factory warranty.
· Perform all electrical installations in accordance with local codes. · Do NOT disconnect the PV module from the HRSD-2C without first disconnecting the AC power. · Installation must be performed by trained professionals only. Hoymiles does not assume liability for loss or damage resulting from improper handling, installation, or misuse of products · Do not attempt to install in inclement weather. · Be aware that the body of the running HRSD-2C is the heat sink and can reach high temperatures.
To reduce the risk of burns, do not touch the body of the HRSD-2C. · Do not operate the HRSD-2C if they have been physically damaged. Check existing cables and
connectors and ensure they are in good condition and appropriate in rating. Do not operate HRSD2C with damaged or substandard wiring or connectors. · Do not connect or disconnect under load. Turning off the Inverter and/or the HRSD-2C products may not reduce this risk. Internal capacitors within the inverter can remain charged for several minutes after disconnecting all power sources. Verify capacitors have discharged by measuring a voltage across inverter terminals before disconnecting wiring if service is required. Wait 30 seconds after rapid shutdown activation before disconnecting DC cables or turning off DC disconnect. · The Transmitter control power supply MUST be on the same AC branch circuit as the inverter to meet rapid shutdown requirements.
© 2022 Hoymiles Power Electronics Inc. All rights reserved.

Rapid Shutdown User Manual
1. Product
1.1 HRSD-2C

Features

· Meets NEC 2017 & NEC 2020 690.12 requirements and SunSpec RSD requirements · Two inputs, an cost-effective option · PLC communication, realize rapid shutdown with Transmitter
· Plug & play, no configuration required · Lower power consumption and wider operating voltage range · Much lower than arc noise. No risk of triggering AFCI

As part of Hoymiles rapid shutdown solution for PV system, HRSD-2C can be connected with two modules. It meets NEC 2017, NEC 2020, UL 1741 and SunSpec Rapid Shutdown requirements, guaranteeing PV system safety.
When installed with and receiving a "permission to operate" signal from Hoymiles Transmitter, HRSD starts proper operation of PV system. In case of emergency, PV system would enter module-level rapid shutdown mode by simply disconnecting the AC power of Transmitter or using an external initiator.

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

01

Rapid Shutdown User Manual
1.2 HT10

Features

· Meets NEC 2017 & NEC 2020 690.12 requirements
· Meets SunSpec RSD requirements
· Equipped with single/dual core · Realize rapid shutdown by simply powering off the Transmitter or using an external initiator

The Transmitter HT10 is part of Hoymiles Rapid Shutdown solution. When paired with Hoymiles rapid shutdown HRSD and powered on, HT10 sends a "permission to operate" signal to HRSD, to make PV modules connected in series and then connect to string inverter, thus producing power.
In case of emergency, PV system would enter module-level rapid shutdown mode by simply disconnecting the AC powerof Transmitter or using an external initiator.

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

02

Rapid Shutdown User Manual
1.3 HT10-Kit

Features

· Meets NEC 2017 & NEC 2020 (690.12) and Sunspec RSD requirements · Module-level rapid shutdown with Hoymiles HRSD · Equipped with single/dual core · Realize rapid shutdown by simply powering off the Transmitter or using an external initiator · Weatherproof outdoor enclosure · Includes power supply

Hoymiles Transmitter HT10-Kit is part of a rapid shutdown solution when paired with Hoymiles rapid shutdown HRSD. While powered on, HT10-Kit sends a "permission to operate" signal to HRSD to keep the PV modules connected in series to the string inverter and producing power.
PV system equipped with HRSD and HT10-Kit enters module-level rapid shutdown by simply disconnecting the AC power of the Transmitterduring emergencies.
Hoymiles Transmitter Outdoor Kit includes one Transmitter, one or two cores, 85~264V power supply and outdoor enclosure.

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

03

Rapid Shutdown User Manual
2. System Overview
~
The HRSD-2C requires a Transmitter or inverter with built-in transmitter for operation. The Transmitter is installed in line with a solar PV inverter. The HRSD-2C starts in the OFF position and measures 1V at the output. When power is supplied to the Transmitter, the HRSD-2C turns ON and allows full PV module voltage. The HRSD-2C constantly receives a "permission to operate" signal from the Transmitter. When power to the Transmitter is cut, this "permission to operate" signal ceases, sending every HRSD-2C into shutdown mode with output reduced to 1V. In this way, PV array enters rapid shutdown in event of AC grid loss.

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

04

Rapid Shutdown User Manual
3. Installation Notes
· Installation MUST comply with local regulations and technical rules.
· Perform all electrical installations in accordance with local codes.
· Be aware that only qualified professionals should install and/or replace the HRSD-2C.
· Before installing or using an HRSD-2C, please read all instructions and warnings in the technical documents and on the inverter system itself as well as on the PV array.
· Be sure to verify the voltage and current specifications of your PV module match with those of the HRSD-2C.
· Never apply an external voltage source to a module or string equipped with HRSD-2C.
· HRSD-2C is shipped in the OFF position and will measure 1V at the output when the "permission to operate" signal is not present.
· Failing to follow the sequence of installation steps may result in HRSD-2C damage not covered under warranty.
· Connect HRSD-2C to its respective modules before connecting its outputs in series.
· Install HRSD-2C before powering on the Transmitter.
· If parallel string connections are needed, first connect the HRSD-2C to the PV modules, then connect all outputs of HRSD-2C in series, and finally pass one side (+ or -) of the string through the Transmitter to turn the system ON.
· Do not touch any live parts in the system, including the PV array, when the system has been connected to the electrical grid.
· Place rapid shutdown system label no more than 1m (3ft) from initiator (AC disconnect) or service panel containing means of disconnection if not at same location.

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

05

Rapid Shutdown User Manual
4. Installation
4.1 HRSD-2C Installation
A ). Buckle HRSD-2C on the PV module frame. HRSD-2C can be installed anywhere on the PV module frame.
Mounting Brackets

Method 1 (Recommended)
Allow a minimum of 1.5 cm of space between the roof and the HRSD-2C enclosure to ensure ventilation and heat dissipation
Method 2

Allow a minimum of 1.5 cm of space between the roof and the HRSD-2C enclosure to ensure ventilation and heat dissipation

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

06

Rapid Shutdown User Manual B ). Connect modules to HRSD-2C inputs. Each HRSD-2C must have a PV module connected to its inputs.

5

6

1 Input1 + 2 Input1 3 Input2 + 4 Input2 5 Output + 6 Output -

12

34

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

07

Rapid Shutdown User Manual C ). Connect the outputs of HRSD-2C in series.
Note: When installing HRSD-2C, connect the input cables to the PV module before connecting the HRSD-2C output cables in series. If disconnecting HRSD-2C, disconnect the HRSD-2C output cables from the string before disconnecting the input cables from the PV module. If connecting HRSD-2C to a single PV module, first Connect PV module to Input 1, and Connect Input 2 cables together. Connectors from different manufacturers cannot be mated with each other. Transmitter must be powered off during HRSD-2C installation. HRSD-2C output Voltage is 0.9V to 1.1V when Transmitter "permit to operate" signal is not present. Max. string length: 30 modules Max. cable length from inverter (+) to inverter (-): 1000 ft (300 m)

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

08

+ +

Rapid Shutdown User Manual
4.2 HT10 Installation
A ). - Mount Transmitter HT10 and power supply on DIN rail. - Connect DC leads from power supply to Transmitter. - Connect Core to Transmitter HT10. - If there is only one core that needs to be connected, please connect Core 1 first.

GND +12 V
N L

12V GND INITIATORINITIATOR+ LED 2 LED 1
CORE 1 LED 2
CORE 2

Transmitter Din Rail PSU Core 1

GND +12 V
N L
© 2022 Hoymiles Power Electronics Inc. All rights reserved.

12V GND INITIATORINITIATOR+ LED 2 LED 1
CORE 1 LED 2
CORE 2

Transmitter Din Rail PSU Core 1
4 Core 2

4
09

Rapid Shutdown User Manual B ). - Pass either positive homerun or negative homerun through cores. - Connect wires to AC side of power supply.
*Only positive homerun or negative homerun through core
*Only positive homerun or negative homerun through core
*Only positive homerun or negative homerun through core

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

10

Rapid Shutdown User Manual C ). - Connect the serially connected outputs of HRSD-2C to the inverter with a DC cable. - Turn on AC power to Transmitter HT10 power supply to activate the "permission to operate" signal.
GRI D
Note: Install HRSD-2C before powering on Transmitter HT10-Kit. Transmitter HT10-Kit power supply must be on the same AC branch circuit as the inverter to meet rapid shutdown requirements. When the PV system is operating, the Power LED1 should be lit and the Signal LED2 should be blinking. Place rapid shutdown system label no more than 1m (3ft) from Transmitter or AC disconnect if not at the same location. Note: Max .number of strings per Core* : 5 (75A core) or 15 (150 A core) Max. current per Core: 75 A or150 A Max. cable length from inverter (+) to inverter (-): 1000 ft (300 m)
* With  6 mm DC cable diameter (without DC connector)

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

11

+ +

Rapid Shutdown User Manual
4.3 HT10-Kit Installation
A ). - Mount Transmitter HT10-Kit and power supply on DIN rail. - Connect DC leads from power supply to Transmitter HT10-Kit. - Connect Core to Transmitter HT10-Kit. If there is only one core that needs to be connected, please connect Core 1 first.

GND +12 V
*85-264 VAC or 180-550 VAC PSU can be used. 180-550 VAC PSU isolation class I requires grounding. 85-264 VAC PSU isolation class II does not require grounding.
N L

12V GND INITIATORINITIATOR+ LED 2 LED 1
CORE 1 LED 2
CORE 2
Transmitter Din Rail PSU Core 1

GND +12 V
N L
© 2022 Hoymiles Power Electronics Inc. All rights reserved.

12V GND INITIATORINITIATOR+ LED 2 LED 1
CORE 1 LED 2 CORE 2
Transmitter Din Rail PSU Core 1 4 Core 2 4
12

Rapid Shutdown User Manual B ). - Pass either positive homerun or negative homerun through cores. - Connect wires to AC side of power supply.

*The waterproof accessories are not supplied and need to be prepared by the installer.

*Only positive homerun or negative homerun through core

* AC Wires for PSU © 2022 Hoymiles Power Electronics Inc. All rights reserved.

*Only positive homerun or negative homerun through core
*Only positive homerun or negative homerun through core
13

Rapid Shutdown User Manual C ). - Connect ground wires. - Ground all conduit connections. - The nonmetallic enclosure does not provide bonding between conduit connections. - Use grounding-type bushings and jumper wires. D ). - Connect the serially connected outputs of HRSD-2C to the inverter with a DC cable. - Turn on AC power to Transmitter HT10-Kit power supply to activate the "permission to operate" signal.
GRI D

Note: Install HRSD-2C before powering on Transmitter HT10-Kit. Transmitter HT10-Kit power supply must be on the same AC branch circuit as the inverter to meet rapid shutdown requirements. When the PV system is operating, the Power LED1 should be lit and the Signal LED2 should be blinking. Place rapid shutdown system label no more than 1m (3 ft) from Transmitter or AC disconnect if not at the same location.
Note: Max. number of strings per Core* : 5 (75 A core) or 15 (150 A core) Max. current per Core: 75 A or150 A Max. cable length from inverter (+) to inverter (-): 1000 ft (300 m)
* With  6 mm DC cable diameter (without DC connector)

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

14

Rapid Shutdown User Manual
4.4 Conduit Drilling Guide
Enclosure Drilling Guide for .75" Conduit
Enclosure Drilling Guide for 1" Conduit

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

15

Rapid Shutdown User Manual

5. Technical Specifiications
5.1 HRSD-2C

Electrical

Input Voltage Range

8-80 V

Output Voltage Range

16-160 V (8-80 V per input)

Maximum Current

15 A (20 A or 25 A optional)

Maximum System Voltage

1000 V (1500 V optional)

Communication Type

SunSpec PLC

Shutdown Output Voltage

1 V

Power Consumption

200 mW

Mechanical

Input Connectors

MC4 (standard)

Input Cable Length

0.45 m

Output Connectors Output Cable Length

MC4 (standard) 2.4 m1

Dimensions

133 x 58 x 16 mm

Environmental

Operating Temperature Range

-40°C to +85°C (-40°F to +185°F)

Outdoor Rating

IP68/NEMA6P

Compliance

Safety

UL1741, CSA C22.2 No. 330-17, IEC/EN 62109-1

EMC

FCC Part15 Class B, ICES-003, IEC/EN 61000-6-1/-2/-3/-4

*1 Fits PV module in landscape and portrait installation.

113333

2400

25

2400

16

450 58

Unit : mm

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

16

Rapid Shutdown User Manual
5.2 HT10
Electrical Transmitter Input Voltage Transmitter Input Current Communication Type Core Max. Number of Cores Connected Max. Current per Core Max. String Voltage Max. Number of Strings per Core1 Mechanical Dimensions Mounting Type Environmental Operating Temperature Range Outdoor Rating Compliance Safety EMC
*1:  6 mm DC cable diameter

12 VDC (+/-2%) 1 A
Sunspec PLC

75 A 5

2 1500 VDC

150 A 15

93 x 36.5 x 53 mm DIN35 Rail

-40°C to +85°C (-40°F to +185°F) IP30/NEMA1

UL1741, CSA C22.2 No. 330-17 FCC Part15 Class B, ICES-003

93 64
200 47
200

Unit : mm 36.5

Transmitter
© 2022 Hoymiles Power Electronics Inc. All rights reserved.

28 Core-150A

17
Core-75A
17

Rapid Shutdown User Manual

5.3 HT10-Kit

Electrical

Power Supply Input Voltage

85-264 VAC

Transmitter Input Voltage

12 VDC (+/-2%)

Transmitter Input Current

1 A

Communication Type

SunSpec PLC

Core

Max. Number of Configure Core

2

Max. Current per Core

75 A

150 A

Max. String Voltage Max. Number of Strings per Core1

1500 VDC

5

15

Mechanical

Dimensions

198.5 x 298 x 179 mm

Mounting Type

Wall mounted

Environmental

Operating Temperature Range

-40°C to +85°C (-40°F to +185°F)

Outdoor Rating

IP65/NEMA4

Compliance

Safety

UL1741, CSA C22.2 No. 330-17

EMC

FCC Part15 Class B, ICES-003

*1 According to the cable diameter  6 mm, if cable diameter is more than  6 mm, Strings Per Core will be reduced. Care should also be taken not to exceed the allowable current.

179

198.5

18

36.5

298 90 93 64
200 47
200

Unit : mm

Power Supply (optional)

© 2022 Hoymiles Power Electronics Inc. All rights reserved.

Transmitter

28 Core-150A

17 Core-75A
18



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.4 (Windows)