Instruction Manual for BRISTAN models including: COB SHCDIV Cobalt Recessed Thermostatic Dual Control Shower, COB SHCDIV, Cobalt Recessed Thermostatic Dual Control Shower, Thermostatic Dual Control Shower, Dual Control Shower
Installation Instructions. & User Guide. Prior to Installation. Please leave these instructions with the end user. All products manufactured and supplied by ...
prieš 2 dienas — Installation Instructions. & User Guide. Prior to Installation. Please leave these instructions with the end user. All products manufactured and supplied by ...
File Info : application/pdf, 2 Pages, 3.46MB
DocumentDocumentInstallation Instructions & User Guide Please leave these instructions with the end user Specifications Dynamic Water Pressure Min: 0.2 bar Max: 5.0 bar 2.0 3.0 1.0 4.0 0. 5.0 Pressure BAR 2.0 3.0 1.0 4.0 0. 5.0 Pressure BAR Maximum Static Pressure: 10.0 bar Tools You'll Need Product Code: COB SHCDIV BLK (D1) Inlet Water Temperature Cold Water Supply Hot Water Supply Inlet Dimensions 150mm Centres 25°C 5°C 65°C Inlet Connections Min: 5°C Max: 25°C IMPORTANT 65°C Recommended The inlet hot water must be at least 10°C above the required blend temperature. 15mm Compression Socket Spanner Flat head Screwdriver Drill Adjustable Spanner Prior to Installation All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions. This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory. Pipe Cutter Silicon Sealant Hexagonal Keys Cavity Dimensions (mm) Minimum Fitting Depth: 60mm Maximum Fitting Depth: 75mm Concealing Plate Adjustment Range: 15mm Pipe & Wire Detector 15 60 Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance. Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc. Full access must be made available for future maintenance/ servicing purposes. Pack Contents x1 Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector. x1 If power tools are used do not forget to: - Wear eye protection - Unplug equipment after use This product must not be modified in any way as this will invalidate the guarantee. x1 x2 If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:- The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB, Tel: 01708 472791 x1 x2 x2 x1 x2 Valve Configuration 1 cocrbInmofejoImguiMuninulessbPclttraiOtantbfiloaolRleoetnrTwidsoAwninNitTh fitted. Yellow Flow Limiter (Hot) Green Flow Limiter (Cold) Remove the inlet elbows and filters. Remove the plastic inserts from the valve inlets and insert the flow regulators. Replace the elbows, ensuring the filters are fitted. 2 Screw the shrouds onto the valve. Installation 2 1 IMPORTANT Rear access to the shower is required for maintenance and servicing Prepare the pipework. Create the rear access point in the back of the wall cavity. 75mm 60mm Cavity Space Install suitable batons (if required) into the cavity. Take the finished wall surface into consideration when fitting the valve Baton into Mark the the cavity. position of the valve; drill Rear and plug holes Access to suit. Point 3 Secure the valve using the screws supplied (solid walls only) or a suitable alternative. 4 beEolpbroodiwnotwsendcaunp Hot Cold Connect the inlet pipes ensuring the olives are fitted. 7 hocRotElodMnEotnMheBthEleeRft, right 5 6 Plumb your chosen outlets into the valve. Turn on the water supply and check the valve for any leaks. Draw around the concealing plate as a template, measuring in by 10mm to give clearance. Finish the wall surface. Using a silicon sealant, push on the concealing plate and hold firmly until set. Temperature Adjustment 1 Turn the handle to the maximum temperature setting, then remove it. Fit the handles. RTEoMsEerMvBicEeR your 2.5 product! 2.5 mm mm 2 Increase Temperature Turn the spindle to increase or 3 decrease the temperature. Fit the Check the temperature temperature and handle back in Pre-set 42°C to Decrease adjust until you achieve the the maximum hot position. Temperature desired result. 2.5 mm General Cleaning Operation Bristan products are made from premium materials, with hand polished, PVD, EPD or electroplated finishes. Your shower should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use. Left Outlet On/ Increased Flow Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar. Increased Temperature Off Right Outlet On/ Increased Flow Decreased Temperature Maintenance - Cartridge Cleaning 3 1 Remove the handles. 2 23 mm 4 IMPORTANT Isolate the water supply before starting! Gently remove the concealing plate from 2.5 mm the wall. 5 123 Unscrew the shrouds. Remove the cartridges and piston. 6 Follow the Temperature Adjustment steps if required. Increase Temperature Remove any O-rings and soak all components in de-scaler and wash off in clean water. Examine all seals and replace if needed. Use WRAS approved silicon based grease on all seals. Notes Reverse the installation steps, ensuring the temperature stop is aligned correctly. Decrease Temperature Troubleshooting Symptom No flow or low flow rate Maximum Water Temperature too Hot/Cold Outlet Water Temperature too Hot/Cold Cause Partially closed isolation valve. Instantaneous water heater cycles on and off as flow rate or pressure is too low. Head of water is below the minimum distance required. Are the water supply pressures balanced? Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes. Airlock or partial blockage in the supply pipework. Hot/Cold water supply has failed Maximum Water Temperature needs adjusting. Filter/pipe blockage Installtion conditions outside operating parameters. Hot water temperature is less than 10°C above the required blend temperature Instantaneous water not igniting because the water flow rate is too low. Remedy Open isolation valve. Increase water flow rate or pressure through system. Refer to the specification for the minimum distance required. If pressures are unbalanced, a pressure reducing valve should be used for optimum performance. Do not use other water outlets when using the shower. Flush through pipework and filters to ensure removal of debris and any airlocks. Check the hot and cold feeds. The shower will not work if either fails. Refer to the Temperature Setting section to set your desired maximum temperature. Flush through pipework and filters to ensure removal of debris and any airlocks. Refer to the specification for the minimum distance required. Adjust hot water temperature or wait for water to reheat if a stored water system is used. Increase water flow rate through the system. Refer to the Maintenance section to clean/check the cartridge and filters for any damage. Contact your boiler manufacturer. Instantaneous water not igniting because the water pressure is too low. Refer to the specification for system requirements. Increase water pressure through the system. Contact your boiler manufacturer. Only hot/ cold water from Shower Valve Water dripping from shower Inlet water supplies are reversed. Filter/pipe blockage This is normal for a short time after using the shower. If water continues to drip, possibly due to the cartridge Check the water inlet connections are the correct way around: Hot on the left, Cold on the right when viewed from the front. Rework pipework as necessary. Flush through pipework and filters to ensure removal of debris and any airlocks. This is caused by residual water tension, the build up of water in the shower. Remove cartridge and clean, refer to 'Maintenance' section before starting any maintenance. Shower does not turn on Closed isolation valve. Mains water supply turned off. Open isolation valve. Turn on mains water supply. Our Guarantee At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register. For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice. For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees. Bristan Group Ltd. UK: Bristan Group, B78 1SG. EU: Masco Europe S.à.r.l., 14 Rue Strachen 6933 Mensdorf, Luxembourg. Customer Service: +44330 026 6273 Web: www.bristan.com Email: enquire@bristan.com A Masco Company