Tank Truck Service & Sales, Inc. Warren, MI 800-482-2678 www.tanktruckservice.com

LectroCount LCR-II™ Electronic Register

Pump and Print Electronic Registration

[Liquid Controls Logo] LectroCount LCR-II Electronic Register

The LectroCount LCR-II is a microprocessor-based electronic meter register from Liquid Controls. It is designed for configuring meter systems, interfacing with electronic components such as pumps and injectors, and performing Weights & Measures approved custody transfer actions.

Product Visual Description

The LectroCount LCR-II unit is depicted as a compact, robust electronic register. It features a blue and grey casing with a clear liquid crystal display (LCD) showing "6317.08 Gallons". Prominent control buttons are labeled "RUN", "STOP", "PRINT", "SHIFT PRINT", "SELECT", and "INCREASE". A rotary selector switch is also visible. The unit displays the "L" logo associated with Liquid Controls.

Benefits

Features

General Information

Liquid Controls' LectroCount LCR-II is a microprocessor-based electronic meter register. Its primary functions include configuring the meter system to the properties of the metered liquid, interfacing with the electronic components of the meter system (and external components such as pumps, injectors, and shutdown devices), and performing Weights & Measures approved custody transfer actions.

The LCR-II performs well in both mobile and fixed installations. It can control a meter system as a standalone unit, or it can be used as a slave to a host controller such as a process controller or an in-cab data management system.

Operation, setup, and configuration functions can be performed using the red rotary selector switch and the 'SELECT' and 'INCREASE' buttons. An external lap pad and EZCommand, a software program for personal computers, are also available for LCR-II setup and configuration.

Specifications

Specification Details
Materials of Construction Aluminum Alloy ADC12, Corro-Coat PE 74-141 Polyester Powder Coat
Weight 8.4 lbs (3.8 kg)
Display Elements Liquid crystal display (LCD)
Cable Entry 1/2" NPT (5 ports), 3/4" NPT (2 ports)
Temperature Rating -40 to 158 °F (-40 to 70 °C)
Input Voltage 9 to 28 VDC, 4.5 A maximum (including solenoid valves)
Pulse Output 5 to 28 V peak to peak, 7500 Hz maximum
Scale Pulse Output 150 mA sinking capability
Electrical Protection 5 A Fuse
Communications RS-232: EIA-232E standard, RS-485: SAE J1708 standard
Auxiliary 1 Output 1 A sinking capability
Auxiliary 2 Output 150 mA sinking capability
Solenoid 1 Output 10.2 to 27.2 VDC, 1 A maximum
Solenoid 2 Output 10.2 to 27.2 VDC, 1 A maximum
Solenoid 3 Output 10.2 to 27.2 VDC, 1 A maximum
Optical Sensor +10 to +28 VDC, 0.5 A maximum
RTD Temperature Probe 4 wire platinum sensor, 100 Ω resistance at 0 °C, 138.5 Ω resistance at 100 °C
Remote Electronic Display 1 A sinking capability

Dimensions

Front View

Dimensions: 15 inches (height) x 9.94 inches (width) x 5.19 inches (depth). The front panel displays the LectroCount LCR-II model name, a liquid crystal display (LCD) showing volume, and control buttons (RUN, STOP, PRINT, SHIFT PRINT, SELECT, INCREASE).

Top View

Dimensions: 13 inches (width) x Ø 7.5 inches (depth). The top view shows the overall shape and width of the unit.

Rear View

The rear panel features a tapped point for a ground screw, five 1/2-inch NPT ports, and two 3/4-inch NPT ports for cable entry and connections. It also includes designated holes for Weights & Measures seals.

Side View

Dimensions: 10.5 inches (height) x 8.04 inches (depth), with an approximate 70° angle. This view illustrates the profile and depth of the unit.

Note: Consult the factory when certified engineering drawings are required. Dimensions shown are not suitable for construction or modifications.

PDF preview unavailable. Download the PDF instead.

LC LCRII Brochure Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Windows)

Related Documents

Preview Liquid Controls LectroCount LCR Installation and Parts Manual
This manual provides detailed instructions for the installation and parts of the Liquid Controls LectroCount LCR electronic meter register. It covers system overview, specifications, regulatory compliance, mounting procedures, wiring diagrams, environmental sealing guidelines, system startup, and illustrated parts breakdown.
Preview Liquid Controls Electronic Registers and Data Management Systems Product Overview
Explore Liquid Controls' advanced electronic registers and data management systems, including LectroCount LCR-II, LCR 600, and DMS. Learn about applications in fuel delivery, aviation fueling, and fleet management, along with key features and accessories.
Preview LectroCount LCR-II Installation & Parts Manual for E3650/E3651 Series
This manual provides detailed installation and parts information for the Liquid Controls LectroCount LCR-II meter register, covering the E3650 and E3651 series. It guides users through the setup, wiring, and operation of this electronic meter register, a key component in Liquid Controls' flow measurement systems.
Preview Liquid Controls LectroCount Electronic Registers: Product Overview and Specifications
Comprehensive product overview of Liquid Controls' LectroCount family of electronic registers, including the LCR-II, LCR³ POS, and DMS Data Management System. Details features, benefits, applications, and accessories for custody transfer and metering systems.
Preview LectroCount LCR-II Setup and Operation Manual
Comprehensive guide to setting up, calibrating, and operating the Liquid Controls LectroCount LCR-II electronic meter register for custody transfer applications.
Preview LectroCount LCR-II Installation Guide for E3657/E3658 Series
This installation manual provides detailed instructions for setting up and installing the Liquid Controls LectroCount LCR-II electronic register, models E3657 and E3658 series. It covers safety precautions, electrical connections, mounting, and system integration for fuel and energy applications.
Preview LectroCount LCR-II E3655/E3656 Series Installation Manual
Comprehensive installation guide for the Liquid Controls LectroCount LCR-II E3655 and E3656 Series electronic meter registers, covering setup, wiring, and system integration.
Preview Liquid Controls LCR.iQ and MASTERLOAD.iQ Installation Guide
Comprehensive installation guide for the Liquid Controls LCR.iQ and MASTERLOAD.iQ electronic meter registers and controllers, covering setup, wiring, specifications, and safety procedures for industrial fluid transfer applications.