Kam MicroGlide

Multicolour sweeping beam effects

MANUAL VERSION 1.0

Date: 20-05-16

For the latest instruction manual updates and information on the entire Kam range visit: www.kam.co.uk

Manufactured by: Lamba plc, Unit 1, Southfields Road, Dunstable, Bedfordshire, United Kingdom LU6 3EJ

Telephone: (+44) (0)1582 690600 | Fax: (+44) (0)1582 690400 | Email: mail@lambaplc.com | Web: www.lambaplc.com

Copyright Lamba plc. E&OE.

Introduction

Thank you for purchasing this Kam product. To optimise its performance, please read these instructions carefully to familiarise yourself with the basic operations of the unit. Please retain them for future reference.

Important Safety Information

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire hazard, do not expose the unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time.

When installing the unit, ensure sufficient space around the unit for ventilation. Slots and openings are provided for reliable operation and to protect from overheating. Never block or cover these openings.

The unit is powered by the mains. Always handle the power cable by the plug, never by the cable itself. Never touch the power cable with wet hands. Do not tie knots in the cable. Ensure the power cable is placed where it is unlikely to be stepped on. A damaged power cable can cause a fire or electrical shock. Check the power cord periodically and replace if damaged. Contact your retailer for a replacement.

Be sure that the power supply voltage of the area where this unit is to be used meets the unit's requirements.

The lightning flash symbol inside a triangle [high-voltage warning] alerts the user to the presence of high voltage within the unit's enclosure that may constitute a risk of electrical shock. Caution: do not attempt to open the unit. No user-serviceable parts inside. Refer all servicing to qualified personnel.

The exclamation mark inside a triangle [important instructions] alerts the user to the presence of important operating and maintenance instructions in the accompanying literature.

Select the installation location carefully. Avoid direct sunlight, locations subject to vibration, and excessive dust. Do not use the unit in extreme temperatures (below 41°F / 5°C or exceeding 95°F / 35°C).

Unpacking and safety: Please unpack your product carefully and check for any damage during transit. If damage is found, do not operate the unit and contact the retailer immediately. If the mains cable is damaged, do not use the device. Always disconnect the unit from the mains supply when cleaning.

Manufacturer Declarations

In compliance with the following requirements: RoHS Directive (2002/95/EU) and WEEE Directive (2002/96/EU).

If this product is no longer functional, please take it to a recycling plant for environmentally friendly disposal.

CE declaration of conformity: R&TTE Directive (1999/5/EU), EMC Directive (2004/108/EU), Low Voltage Directive (2006/95/EU).

Declarations are available on application from certification@lambaplc.com. Before operation, observe respective country-specific regulations.

Overhead Rigging

Important: Installation must be carried out by qualified service personnel only. Improper installation can result in serious injuries and/or damage to property. Overhead rigging requires extensive experience. Respect working load limits, use certified installation materials, and inspect the installed unit regularly for safety.

Packing List

AC Power

The unit is supplied with a power plug appropriate to its voltage. For other connections, use the following configuration:

Cable (EU) Cable (US) Pin International
Brown Black Live L
Light blue White Neutral N
Yellow/green Green Earth [earth connection]

DMX-512 Connection

To connect units in a DMX chain using a standard DMX controller, connect the controller's DMX output directly to the first unit's DMX input. If using a controller with other XLR outputs, adapter cables may be needed.

DMX output pinout:

Connect the DMX output of the first unit to the DMX input of the next unit in the chain. Continue this process until all units are connected.

Unit Features and Connections

The unit features DMX input/output, power input/output, and a control panel for operation.

Rear Panel Features:

Front Panel Features:

Key to Rear Panel Features

Number Feature Function
1DMX input3 pin XLR connector for DMX512 input communication
2DMX output3 pin XLR connector for DMX512 output communication
3Power inputMains power input IEC socket
4Power outputIEC connector socket for connecting multiple units for power
5Rotating armLights are mounted on these arms for projection
6Microphone sensorSensor for Sound-to-Light operation
7Control panelSection for controlling unit
8Menu buttonCycles through the different functions
9Menu UP buttonIncreases parameter values
10Menu DOWN buttonDecreases parameter values
11ENTER buttonSelects the desired function
12DMX LEDIllumination confirms as DMX
13Slave mode LEDIllumination confirms unit is in Slave mode
14Master mode LEDIllumination confirms unit is in Master mode
15Sound mode LEDIllumination confirms unit is in sound to light mode
16LED setting displayShows the various menus and selected functions

Function Setting

Use the four function buttons on the rear of the unit to set the operating mode. Press the Menu button to display functions, then use the Up or Down arrow buttons to make your selection. Press Enter to confirm.

Menu display Function
AddrDMX address setting (A001-A512), changed using Up/Down buttons.
ChNdSwitches between 7 Channel and 13 Channel DMX operation.
SLNdNASt - denotes Master mode; SLAu - denotes Slave mode.
ShNdAuto – Automatic mode scrolling through built-in light shows.
SoUnSound to light mode with unit moving in time with the music.
SoUn (on/off)'on' – Sound to light mode is switched on; 'oFF' – Sound to light mode is switched off.
SenSSound sensitivity in sound to light mode (0 = least sensitive, 100 = most sensitive).
Led'on' – LED display remains on; 'OFF' – LED display goes blank.
dISp'no' – standard orientation; 'yes' – display rotated 180 degrees for inverted mounting.
1tiL'no' – tilts front arm towards you; 'yes' – tilts front arm away from you.
2tiL'no' – tilts rear arm towards you; 'yes' – tilts rear arm away from you.
testUnit runs through test cycle.
hoUrShows how many hours operation the unit has completed.
uErShows the version number of the unit.
rSetResets the unit.

DMX Control

DMX Address Setting

When controlling units with a DMX controller, each unit must have a specific DMX address. Units can be set with the same address for synchronized operation or with individual addresses for independent control.

If setting individual addresses, the address must be determined by the number of channels. For example, in 7Ch mode, the first unit is A001, the second A008 (1+7), the third A015 (8+7), and so on.

7 Channel DMX Control Table

DMX channel Value Function
CH10-255Tilt Motor 1 Movement 0°-135°
CH20-255Tilt Motor 2 Movement 0°-135°
CH30-255Dimmer 0-100%
CH4 0-9 Off
10-255 Strobe speed Slow-Fast
CH5 0-7 Off
8-17Show 1
18-27Show 2
28-37Show 3
38-47Show 4
48-57Show 5
58-67Show 6
68-77Show 7
78-87Show 8
88-97Show 9
98-107Show 10
108-117Show 11
118-127Show 12
128-136Show 13
137-146Show 14
147-156Show 15
157-166Show 16
167-176Show 17
177-186Show 18
187-196Show 19
197-206Show 20
207-216Show 21
217-226Show 22
227-236Show 23
237-246Show 24
247-255Show 25
CH60-255Show Speed Fast - Slow
CH7 0-199 Nothing
200-249Resets All (after 3 second valid)
250-255Random sound activated mode

13 Channel DMX Control Table

DMX channel Value Function
CH10-255Tilt Motor 1 Movement 0°-135°
CH20-255Tilt Motor 2 Movement 0°-135°
CH30-255Dimmer 0-100%
CH4 0-9 Off
10-255 Strobe speed Slow-Fast
CH50-255LED 1 Dimmer 0-100%
CH60-255LED 2 Dimmer 0-100%
CH70-255LED 3 Dimmer 0-100%
CH80-255LED 4 Dimmer 0-100%
CH90-255LED 5 Dimmer 0-100%
CH100-255LED 6 Dimmer 0-100%
CH110-255LED 7 Dimmer 0-100%
CH120-255LED 8 Dimmer 0-100%
CH13 0-199 Nothing
200-249Resets all after 3 seconds
250-255Random sound activated mode

Master/Slave Operation

Connect units in a Master/Slave chain using 3-pin DMX cables:

  1. Connect the DMX output of the Master unit to the DMX input of the first Slave unit.
  2. Connect another DMX cable from the first Slave unit's DMX output to the second Slave unit's DMX input.
  3. Continue this process until all units are connected.
  4. Set the Master unit to 'NASt' and the first Slave unit to 'SLAu'.
  5. Slave units will now follow the operation of the Master unit.

Product Specification

Mains power / rated power AC220~240V, 50/60Hz / 46w
Control modes 7 or 13 channel DMX512 / Auto / Sound-to-Light / Master/Slave
Beam angle 75°
Light source 8 x 3w high power LED's (2 x red, 2 x green, 2 x blue, 2 x white)
Operating temperature 0°C to 40°C
DMX512 connections 3 pins XLR male/female
Dimensions (WxDxH) 283 x 151 x 147mm (not including bracket)
Nett weight 2.5kg

Due to continuous product development, specifications and appearance are subject to change.

1465387988 6805 Mac OS X 10.10.5 Quartz PDFContext Word

Related Documents

Preview KAM DMX1500 STROBE Instruction Manual - Professional DMX Strobe Light
Detailed instruction manual for the KAM DMX1500 STROBE, a professional DMX 512 controlled strobe light. Learn about its features, specifications, setup, dip switch operation, warnings, and usage for stage and event lighting.
Preview KAM KML501 Terra Fog Machine User Manual
Comprehensive user guide for the KAM KML501 Terra Fog Machine, covering setup, operation, DMX control, wireless remote functions, and maintenance.
Preview Meble Kuchenne KAM: Nowoczesne Rozwiązania i Wysoka Jakość
Odkryj meble kuchenne KAM – polskiego producenta z tradycją od 1991 roku. Poznaj systemy KAMPLUS, PREMIUM Kammoduł i PRO-LINE Kammoduł, oferujące funkcjonalność i styl.