Kam MicroGlide
Multicolour sweeping beam effects
MANUAL VERSION 1.0
Date: 20-05-16
For the latest instruction manual updates and information on the entire Kam range visit: www.kam.co.uk
Manufactured by: Lamba plc, Unit 1, Southfields Road, Dunstable, Bedfordshire, United Kingdom LU6 3EJ
Telephone: (+44) (0)1582 690600 | Fax: (+44) (0)1582 690400 | Email: mail@lambaplc.com | Web: www.lambaplc.com
Copyright Lamba plc. E&OE.
Introduction
Thank you for purchasing this Kam product. To optimise its performance, please read these instructions carefully to familiarise yourself with the basic operations of the unit. Please retain them for future reference.
Important Safety Information
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire hazard, do not expose the unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time.
When installing the unit, ensure sufficient space around the unit for ventilation. Slots and openings are provided for reliable operation and to protect from overheating. Never block or cover these openings.
The unit is powered by the mains. Always handle the power cable by the plug, never by the cable itself. Never touch the power cable with wet hands. Do not tie knots in the cable. Ensure the power cable is placed where it is unlikely to be stepped on. A damaged power cable can cause a fire or electrical shock. Check the power cord periodically and replace if damaged. Contact your retailer for a replacement.
Be sure that the power supply voltage of the area where this unit is to be used meets the unit's requirements.
The lightning flash symbol inside a triangle [high-voltage warning] alerts the user to the presence of high voltage within the unit's enclosure that may constitute a risk of electrical shock. Caution: do not attempt to open the unit. No user-serviceable parts inside. Refer all servicing to qualified personnel.
The exclamation mark inside a triangle [important instructions] alerts the user to the presence of important operating and maintenance instructions in the accompanying literature.
Select the installation location carefully. Avoid direct sunlight, locations subject to vibration, and excessive dust. Do not use the unit in extreme temperatures (below 41°F / 5°C or exceeding 95°F / 35°C).
Unpacking and safety: Please unpack your product carefully and check for any damage during transit. If damage is found, do not operate the unit and contact the retailer immediately. If the mains cable is damaged, do not use the device. Always disconnect the unit from the mains supply when cleaning.
Manufacturer Declarations
In compliance with the following requirements: RoHS Directive (2002/95/EU) and WEEE Directive (2002/96/EU).
If this product is no longer functional, please take it to a recycling plant for environmentally friendly disposal.
CE declaration of conformity: R&TTE Directive (1999/5/EU), EMC Directive (2004/108/EU), Low Voltage Directive (2006/95/EU).
Declarations are available on application from certification@lambaplc.com. Before operation, observe respective country-specific regulations.
Overhead Rigging
Important: Installation must be carried out by qualified service personnel only. Improper installation can result in serious injuries and/or damage to property. Overhead rigging requires extensive experience. Respect working load limits, use certified installation materials, and inspect the installed unit regularly for safety.
- Ensure the area below the installation place is free from persons during rigging, de-rigging, and servicing.
 - Locate the unit in a well-ventilated spot, far from flammable materials and/or liquids. The fixture must be fixed at least 50cm from surrounding walls.
 - Install the device out of reach of people and outside of areas where persons may walk by or be seated.
 - Before rigging, ensure the installation area can hold a minimum point load of 10 times the device's weight.
 - The device must be well fixed; a free-swinging mounting is dangerous.
 - Do not cover any ventilation opening, as this may result in overheating.
 - Before first use, the unit should be inspected for safety. Inspect the unit regularly every year.
 
Packing List
- Lighting unit and bracket
 - Power cable
 - Instruction manual
 - Warranty
 
AC Power
The unit is supplied with a power plug appropriate to its voltage. For other connections, use the following configuration:
| Cable (EU) | Cable (US) | Pin | International | 
|---|---|---|---|
| Brown | Black | Live | L | 
| Light blue | White | Neutral | N | 
| Yellow/green | Green | Earth | [earth connection] | 
DMX-512 Connection
To connect units in a DMX chain using a standard DMX controller, connect the controller's DMX output directly to the first unit's DMX input. If using a controller with other XLR outputs, adapter cables may be needed.
DMX output pinout:
- 1 = Shield
 - 2 = Signal (-)
 - 3 = Signal (+)
 
Connect the DMX output of the first unit to the DMX input of the next unit in the chain. Continue this process until all units are connected.
Unit Features and Connections
The unit features DMX input/output, power input/output, and a control panel for operation.
Rear Panel Features:
- 1. DMX IN: 3-pin XLR connector for DMX512 input.
 - 2. DMX OUT: 3-pin XLR connector for DMX512 output.
 - 3. POWER IN: Mains power input IEC socket.
 - 4. POWER OUT: IEC connector socket for connecting multiple units for power.
 - 5. Rotating arm: For mounting the lights.
 
Front Panel Features:
- 6. MicroGlide: Product name.
 - 7. Control Panel: Section for controlling the unit, featuring a display and buttons.
 
Key to Rear Panel Features
| Number | Feature | Function | 
|---|---|---|
| 1 | DMX input | 3 pin XLR connector for DMX512 input communication | 
| 2 | DMX output | 3 pin XLR connector for DMX512 output communication | 
| 3 | Power input | Mains power input IEC socket | 
| 4 | Power output | IEC connector socket for connecting multiple units for power | 
| 5 | Rotating arm | Lights are mounted on these arms for projection | 
| 6 | Microphone sensor | Sensor for Sound-to-Light operation | 
| 7 | Control panel | Section for controlling unit | 
| 8 | Menu button | Cycles through the different functions | 
| 9 | Menu UP button | Increases parameter values | 
| 10 | Menu DOWN button | Decreases parameter values | 
| 11 | ENTER button | Selects the desired function | 
| 12 | DMX LED | Illumination confirms as DMX | 
| 13 | Slave mode LED | Illumination confirms unit is in Slave mode | 
| 14 | Master mode LED | Illumination confirms unit is in Master mode | 
| 15 | Sound mode LED | Illumination confirms unit is in sound to light mode | 
| 16 | LED setting display | Shows the various menus and selected functions | 
Function Setting
Use the four function buttons on the rear of the unit to set the operating mode. Press the Menu button to display functions, then use the Up or Down arrow buttons to make your selection. Press Enter to confirm.
| Menu display | Function | 
|---|---|
| Addr | DMX address setting (A001-A512), changed using Up/Down buttons. | 
| ChNd | Switches between 7 Channel and 13 Channel DMX operation. | 
| SLNd | NASt - denotes Master mode; SLAu - denotes Slave mode. | 
| ShNd | Auto – Automatic mode scrolling through built-in light shows. | 
| SoUn | Sound to light mode with unit moving in time with the music. | 
| SoUn (on/off) | 'on' – Sound to light mode is switched on; 'oFF' – Sound to light mode is switched off. | 
| SenS | Sound sensitivity in sound to light mode (0 = least sensitive, 100 = most sensitive). | 
| Led | 'on' – LED display remains on; 'OFF' – LED display goes blank. | 
| dISp | 'no' – standard orientation; 'yes' – display rotated 180 degrees for inverted mounting. | 
| 1tiL | 'no' – tilts front arm towards you; 'yes' – tilts front arm away from you. | 
| 2tiL | 'no' – tilts rear arm towards you; 'yes' – tilts rear arm away from you. | 
| test | Unit runs through test cycle. | 
| hoUr | Shows how many hours operation the unit has completed. | 
| uEr | Shows the version number of the unit. | 
| rSet | Resets the unit. | 
DMX Control
DMX Address Setting
When controlling units with a DMX controller, each unit must have a specific DMX address. Units can be set with the same address for synchronized operation or with individual addresses for independent control.
If setting individual addresses, the address must be determined by the number of channels. For example, in 7Ch mode, the first unit is A001, the second A008 (1+7), the third A015 (8+7), and so on.
7 Channel DMX Control Table
| DMX channel | Value | Function | 
|---|---|---|
| CH1 | 0-255 | Tilt Motor 1 Movement 0°-135° | 
| CH2 | 0-255 | Tilt Motor 2 Movement 0°-135° | 
| CH3 | 0-255 | Dimmer 0-100% | 
| CH4 | 0-9 | Off | 
| 10-255 | Strobe speed Slow-Fast | |
| CH5 | 0-7 | Off | 
| 8-17 | Show 1 | |
| 18-27 | Show 2 | |
| 28-37 | Show 3 | |
| 38-47 | Show 4 | |
| 48-57 | Show 5 | |
| 58-67 | Show 6 | |
| 68-77 | Show 7 | |
| 78-87 | Show 8 | |
| 88-97 | Show 9 | |
| 98-107 | Show 10 | |
| 108-117 | Show 11 | |
| 118-127 | Show 12 | |
| 128-136 | Show 13 | |
| 137-146 | Show 14 | |
| 147-156 | Show 15 | |
| 157-166 | Show 16 | |
| 167-176 | Show 17 | |
| 177-186 | Show 18 | |
| 187-196 | Show 19 | |
| 197-206 | Show 20 | |
| 207-216 | Show 21 | |
| 217-226 | Show 22 | |
| 227-236 | Show 23 | |
| 237-246 | Show 24 | |
| 247-255 | Show 25 | |
| CH6 | 0-255 | Show Speed Fast - Slow | 
| CH7 | 0-199 | Nothing | 
| 200-249 | Resets All (after 3 second valid) | |
| 250-255 | Random sound activated mode | 
13 Channel DMX Control Table
| DMX channel | Value | Function | 
|---|---|---|
| CH1 | 0-255 | Tilt Motor 1 Movement 0°-135° | 
| CH2 | 0-255 | Tilt Motor 2 Movement 0°-135° | 
| CH3 | 0-255 | Dimmer 0-100% | 
| CH4 | 0-9 | Off | 
| 10-255 | Strobe speed Slow-Fast | |
| CH5 | 0-255 | LED 1 Dimmer 0-100% | 
| CH6 | 0-255 | LED 2 Dimmer 0-100% | 
| CH7 | 0-255 | LED 3 Dimmer 0-100% | 
| CH8 | 0-255 | LED 4 Dimmer 0-100% | 
| CH9 | 0-255 | LED 5 Dimmer 0-100% | 
| CH10 | 0-255 | LED 6 Dimmer 0-100% | 
| CH11 | 0-255 | LED 7 Dimmer 0-100% | 
| CH12 | 0-255 | LED 8 Dimmer 0-100% | 
| CH13 | 0-199 | Nothing | 
| 200-249 | Resets all after 3 seconds | |
| 250-255 | Random sound activated mode | 
Master/Slave Operation
Connect units in a Master/Slave chain using 3-pin DMX cables:
- Connect the DMX output of the Master unit to the DMX input of the first Slave unit.
 - Connect another DMX cable from the first Slave unit's DMX output to the second Slave unit's DMX input.
 - Continue this process until all units are connected.
 - Set the Master unit to 'NASt' and the first Slave unit to 'SLAu'.
 - Slave units will now follow the operation of the Master unit.
 
Product Specification
| Mains power / rated power | AC220~240V, 50/60Hz / 46w | 
|---|---|
| Control modes | 7 or 13 channel DMX512 / Auto / Sound-to-Light / Master/Slave | 
| Beam angle | 75° | 
| Light source | 8 x 3w high power LED's (2 x red, 2 x green, 2 x blue, 2 x white) | 
| Operating temperature | 0°C to 40°C | 
| DMX512 connections | 3 pins XLR male/female | 
| Dimensions (WxDxH) | 283 x 151 x 147mm (not including bracket) | 
| Nett weight | 2.5kg | 
Due to continuous product development, specifications and appearance are subject to change.